• 제목/요약/키워드: Heater Power

검색결과 473건 처리시간 0.03초

히터트리거를 이용한 고온초전도전원장치의 제작 및 특성 실험에 관한 연구 (The Fabrication and Characteristic Experiment of a Heater-Trigger type High-Tc Superconducting Power Supply)

  • 윤용수;김호민;추용;이창열;고태국;한태수
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제48권9호
    • /
    • pp.484-489
    • /
    • 1999
  • This paper deals with the design and fabrication of a heater-trigger type high-Tc superconducting power supply system, and characteristics have been analyzed through experiments. The high-Tc superconducting power supply consists of two heater trigger and electric magnet, and YBCO superconducting bulk. In this experiment, 0.6T class magnet and dc 2.3A heater current are used, and the current-pumping characteristics have been analyzed with computer aided sequence control system. Hall sensors are installed on the YBCO bulk and in the center of iron core in order to analyze the effect of the flux-pumping on the system with when magnet flux changes its value. In this experiment, maximum pumping-current has been achieved to about 6.6 amps.

  • PDF

Development of Induction Heated Hot Water Producer using Soft Switching PWM High Frequency Inverter

  • Fujita Kentarou;Moisseev Serguei;Gaimage Laknath;Chandhaket Sarawouth;Muraoka Hidekazu;Nakaoka Mutsuo
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2003년도 춘계전력전자학술대회 논문집(2)
    • /
    • pp.491-494
    • /
    • 2003
  • This paper presents a new conceptual electromagnetic induction eddy current-based stainless steel plate spiral type heater for heat exchanger or Dual Packs Heater in hot water producer, boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, all active clamped edge resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle oi zero voltage soft communication with PWM is developed and demonstrated for a high efficient Induction heated hot water producer and boiler in the consumer power applications. This consumer induction heater power appliance using active clamp soft switching PWM high frequency inverter is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF

마이크로 가스센서의 열적 성능에 관한 연구 (A Study of Thermal Performances for Micro Gas Sensor)

  • 주영철;김창교
    • 대한기계학회논문집B
    • /
    • 제30권6호
    • /
    • pp.531-537
    • /
    • 2006
  • A lever type $NO_2$ micro gas sensor was fabricated by MEMS technology. In order to heat up the gas sensing material to a target temperature, a micro heater was built on the gas sensor. The sensing material laid on the heater and electrodes and did not contact with the silicon base to minimize the heat loss to the silicon base. The electric power to heat up the gas sensor to a target temperature was measured. The temperature distribution of micro gas sensor was analyzed by a CFD program. The predicted electric power of micro heater to heat up the sensing material to the target temperature showed a good agreement with the measured data. The design of micro gas sensor could be modified to show more uniform temperature distribution and to consume less electric power by optimizing the layout of micro heater and electrodes.

전기히터의 설계 변수에 따른 순간온수기 열유동 특성 해석 (Analysis of heat and fluid flows in an instant water heater according to design parameters of an electric heat device)

  • 쑨휘;김준현;성재용
    • 한국가시화정보학회지
    • /
    • 제21권3호
    • /
    • pp.23-32
    • /
    • 2023
  • This study aims to explore the heat transfer and flow phenomena inside an instant water heater and the influence of the design parameters of the water heater on the heating performance was investigated by 3-D numerical simulations considering heat convection. The design parameters are the heating ceramic dimension, the power of the heating device, and the water flow rate. The results show that a reasonable space for the heating device is required to optimize the heating performance. It is desirable to design higher heating device as possible for a given electric power. There exists a critical water flow rate that best meets the heating performance. The change in electric power has no impact on the flow phenomena and heating performance.

석유 홴 히터의 난방 능력 고찰 (Investigation of Heating Performance of Kerosene Fan Heater)

  • 김장권;정규조
    • 동력기계공학회지
    • /
    • 제1권1호
    • /
    • pp.51-60
    • /
    • 1997
  • In this paper, we investigated the heating performance and the basic characteristics required for normal combustion of kerosene fan heater. And also the iso-velocity contours and the iso-temperature contours of hot gas discharged from the exit of kerosene fan heater were analyzed. The experiment was carried out with kerosene fan heater attached to the blow-down-type subsonic wind tunnel with a test section of $240mm{\times}240mm{\times}1200mm$. The purpose of this paper was to obtain the basic data for new design from conventional kerosene fan heater. Consequently it was found that (i) the pressure ratio $P_2/P_1$ had a comparatively constant value of 0.844 according to the increase of the revolution of turbo fan, (ii) the primary excess air ratio had a range of $0.84{\sim}1.11$ during normal combustion, and (iii) the heating performance of kerosene fan heater had a range of $1,494{\sim}3,852kcal/hr$.

  • PDF

충돌로 인해 분산된 2상 제트스팀의 재부착 현상과 국부 감육 상관관계 규명 및 설계개선에 관한 연구 (Design Modification and Correlation Verification between Reattachment Flow of Dispersed Jet and Local Thinning of Feedwater Heater)

  • 김형준;김경훈;황경모
    • 설비공학논문집
    • /
    • 제21권9호
    • /
    • pp.483-495
    • /
    • 2009
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damange, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle-installed downstream of the high pressure turbine extraction stream line-inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes operation of experience and numerical analysis composed similar condition with real high pressure feedwater heater. This study applied squared, curved and new type impingement baffle plates to feedwater heater same as previous study. In addition, it shows difference of pressure distribution and value between single phase and two phase based on experience and numerical analysis.

재열기를 사용한 고성능 VI 사이클 열펌프의 난방 성능 특성에 관한 연구 (A Study on the Characteristics of Heating Performance of High-Performance Heat Pump with VI cycle using Re-Heater)

  • 이진국;최광환
    • 동력기계공학회지
    • /
    • 제19권4호
    • /
    • pp.69-75
    • /
    • 2015
  • In this study, the characteristics of heating performance of a high-performance air-cooled heat pump with vapor-injection(VI) cycle using re-heater was investigated experimentally. Devices used in the experiment is consist of a VI compressor, condenser, oil separator, refrigerant (economizer outlet refrigerant) re-heater, economizer, evaporator. And R410A was used as a working fluid. The experiment was conducted with two cycles(cycles A and B) for investigating heating performance. In case of cycle B, heat exchange was conducted by re-heater between outlet refrigerant of compressor and suction refrigerant of the VI system(Fig.1, re-heater). But the re-heater was not used in case of cycle A. As a result of this experiment, discharge temperature of refrigerator in compressor was shown higher value, when the cycle B was conducted, because of the heat exchange between suction refrigerant of VI cycle and outlet refrigerant of compressor in the re-heater than cycle A that was not use re-heater. it means that liquid hammer and the decrement of heating performance can be decreased by using re-heater. Also, Heating coefficient of performance(COPh) was shown about 2.98 in Cycle B which was 4% higher than Cycle A and from these results, It was confirmed that the improvement of the heating performance of heat pump with VI cycle can be achieved by applying re-heater.

적외선 패널히터의 온도분포 측정 (Measurement of Temperature Distribution in the Infrared Panel Heater)

  • 이공훈;하수석;김욱중
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1178-1183
    • /
    • 2004
  • Temperature distribution and heating characteristic of the panel heater for infrared heating have been investigated. The temperature variation with time is firstly measured with the thermocouple to figure out the response time of the heater to the power input. The heater reaches faster to the steady state in comparison to the ceramic heater. The infrared thermal imaging system is utilized to investigate the temperature distribution over the heater surface. The measured thermal images show that the thermal boundary layer induced by the free convection near the heater surface affects the temperature distribution on the surface. The images also show the fairly good uniformity of the temperature distribution in the core region of the surface.

  • PDF

기주의 열음향진동에 관한 연구 (A Study on the Thermoacoustic Oscillation of an Air Column)

  • 권영필;이병호
    • 대한기계학회논문집
    • /
    • 제11권2호
    • /
    • pp.253-261
    • /
    • 1987
  • 본 논문에서는 이러한 점들을 보완하여 Fig.1에 도시한 Rijke 관에서 나선형 가열기에 의한 음향력의 발생량을 계산하고 기주진동을 일으키는데 필요한 가열량을 계산하고 기주진동을 일으키는데 필요한 가열량을 구하였다. 이론을 뒷받침하기 위 하여 실험을 하고 결과를 비교 검토하였다.