• 제목/요약/키워드: Heated glass

검색결과 125건 처리시간 0.037초

광섬유 고속인출공정용 유리섬유 냉각장치 내 공기유입에 의한 내부헬륨농도 저하현상 연구 (HELIUM CONCENTRATION DECREASE DUE TO AIR ENTRAINMENT INTO GLASS FIBER COOLING UNIT IN A HIGH SPEED OPTICAL FIBER DRAWING PROCESS)

  • 김경진;김동주;곽호상;박상희;송시호
    • 한국전산유체공학회지
    • /
    • 제15권4호
    • /
    • pp.92-98
    • /
    • 2010
  • In a modern high speed drawing process of optical fibers, it is necessary to use helium as a cooling gas in a glass fiber cooling unit in order to sufficiently cool down the fast moving glass fiber freshly drawn from the heated silica preform in the furnace. Since the air is entrained unavoidably when the glass fiber passes through the cooling unit, the helium is needed to be injected constantly into the cooling unit. The present numerical study investigates and analyzes the air entrainment using an axisymmetric geometry of glass fiber cooling unit. The effects of helium injection rate and direction on the air entrainment rate are discussed in terms of helium purity of cooling gas inside the cooling unit. For a given rate of helium injection, it is found that there exists a certain drawing speed that results in sudden increase in the air entrainment rate, which leads to the decreasing helium purity and therefore the cooling performance of the glass fiber cooling unit. Also, the helium injection in aiding direction is found to be more advantageous than the injection in opposing direction.

피코초 레이저를 이용한 Eagle Glass 절단 시 가공성 평가 (Processing Evaluations of the Eagle Glass Cutting Using Pico-second Laser)

  • 이상균;이영곤;김재도
    • 한국정밀공학회지
    • /
    • 제30권4호
    • /
    • pp.403-408
    • /
    • 2013
  • In this paper, the characteristics of ablation processing of the eagle glass by pico-second laser are investigated. The laser ablation is used to process micro forms on materials. The ablation causes little thermal effect and little burr on the surface of eagle glass. In order to examine the characteristics of panic cracks, experiments are conducted under various cutting conditions such as a frequency of 600 kHz, laser powers, scan speeds and number of scan(NS). To minimize the panic cracks, the specimens are heated at $30^{\circ}C$, $45^{\circ}C$, and $60^{\circ}C$ for ten minutes respectively and then they are broken by hands. Laser powers, NS and scan speeds have an effect on glass cutting results. The ablation depths increase with an increase in the laser power and NS whereas the panic cracks decrease with an increase in scan speed. The high temperature on processed specimens reduces the panic cracks and makes good results of laser cutting. The optimal condition for eagle glass laser cutting is found to be at 30 W of laser power, 3 mm/s of scan speed and 500 of NS, respectively.

Properties of Glass-Ceramics in the System CaO-TiO2-SiO2 with the Additives of Al2O3, ZrO2 and B2O3 for Use in the Solid Oxide Fuel Cells.

  • Lee, Jun-Suk;Park, Min-Jin;Shin, Hyun-Ick;Lee, Jae-Chun
    • The Korean Journal of Ceramics
    • /
    • 제5권4호
    • /
    • pp.336-340
    • /
    • 1999
  • Glasses in the system $CaO-TiO_2-SiO_2-Al_2O_3-ZrO_2-B_2O_3$ were investigated to find the glass seal compositions suitable for use in the planar solid oxide fuel cell (SOFC). Glass-ceramics prepared from the glasses by one-stage heat treatment at $1,000^{\circ}C$ showed various thermal expansion coefficients (i,e., $8.6\times10^{-6^{\circ}}C^{-1}$ to $42.7\times10^{-6^{\circ}}C^{-1}$ in the range 25-$1,000^{\circ}C$) due to the viscoelastic response of glass phase. The average values of contact angles between the zirconia substrate and the glass particles heated at 1,000-$1,200^{\circ}C$ were in the range of $131^{\circ}\pm4^{\circ}$~$137^{\circ}\pm9^{\circ}$, indicating that the glass-ceramic was in partial non-wetting condition with the zirconia substrate. With increasing heat treatment time of glass samples from 0.5 to 24 h at $1,100^{\circ}C$, the DC electrical conductivity of the resultant glass-ceramics decreased from at $800^{\circ}C$. Isothermal hold of the glass sample at $1100^{\circ}C$ for 48h resulted in diffusion of Ca, Si, and Al ions from glass phase into the zirconia substrate through the glass/zirconia bonding interface. Glass phase and diffusion of the moving ion such as $Ca^{2+}$ in glass phase is responsible for the electrical conduction in the glass-ceramics.

  • PDF

PDP 제조 공정시 유리의 열충격 파손 예측 (Prediction of thermal shock failure of glass during PDP manufacturing process)

  • 김재현;최병익;이학주
    • 한국정밀공학회지
    • /
    • 제21권2호
    • /
    • pp.122-129
    • /
    • 2004
  • There is an increasing need for large flat panel display devices. PDP (Plasma Display Panel) is one of the most promising candidates for this need. Thermal shock failure of PDP glass during manufacturing process is a critical issue in PDP industry since it is closely related to the product yield and the production speed. In this study, thermal shock resistance of PDP glass is measured by water quenching test and an analysis scheme is described for estimating transient temperature and stress distributions during thermal shock. Based on the experimental data and the analysis results, a simple procedure for predicting the thermal shock failure of PDP glass is proposed. The fast cooling process for heated glass plates can accelerate the speed of PDP production, but often leads to thermal shock failure of the glass plates. Therefore, a design guideline for preventing the failure is presented from a viewpoint of high speed PDP manufacturing process. This design guideline can be used for PDP process design and thermal -shock failure prevention.

상부가열인 다공물질내의 열파이프 현상에 관한 실험적 연구 (Experimental study of the heat pipe phenomenon in porous media heated from above)

  • 이진호;김홍제;함윤영;남궁규완
    • 대한기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.825-832
    • /
    • 1988
  • 본 연구에서는 1차원 열흐름하에서 상부가 가열된 다공물질내의 열파이프 현 상과 관련하여 2상영역의 존재와 그 길이에 영향을 미치는 인자들을 실험적으로 관찰, 조사하였다.

다공성 세라믹의 발포에 관한 연구 (A Study on Bloating of Porous Ceramic)

  • 김귀식;김현관;정지현
    • 동력기계공학회지
    • /
    • 제17권2호
    • /
    • pp.108-113
    • /
    • 2013
  • In this study, lightweight aggregate was made from basalt stone powder sludge. Clay and glass powder were respectively added from 0 to 20 wt% and from 0 to 100 wt%. The glass powder helped to form glassy phase which trapped generating gas in the materials. $CaCO_3$ helping bloating process was added from 0 to 10 wt%. It was possible to produce lightweight aggregate at range from $1150^{\circ}C$ to $1200^{\circ}C$. The specimen was heated in furnace at 1100, 1150 and $1200^{\circ}C$ for 15 min, respectively, to sinter aggregates. Chemical composition of materials were determined, and characteristics were analyzed, including specific gravity, water absorption. Lightweight aggregate which was heated at $1200^{\circ}C$ had specific gravity of $0.53g/cm^3$, water absorption of 3.08%, and this value satisfied KS L 8551 standard.

등축 유로 장착 이중 태양열 진공관의 열적 특성에 관한 수치해석적 연구 (A Numerical Study on the Thermal Characteristics of Double Skin Vacuum Tubes with Coaxial Fluid Conduit)

  • 현준호;박윤철;천원기;이상진
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 춘계학술대회
    • /
    • pp.567-570
    • /
    • 2006
  • A numerical study has been carried out for a solar water heater which consists of double skin solar vacuum tubes. Water is heated as it flows through the coaxial fluid conduit inserted in each tube. The space between the exterior of the fluid conduit and the glass tube is tilled with antifreeze solution. This is to facilitate heat transfer from the solar heated absorber surface to water and to prevent the functional problems due to freezing in frigid weather conditions. A one-dimensional steady state model is fully described which will be used to develop three-dimensional model using STAR-CD. These models could be used efficiently in designing double skin solar collector tubes with different geometrical parameters other than those considered in the present analysis. Results show a good agreement when compared with other experimental data demonstrating the reliability of the one-dimensional model employed.

  • PDF

구치부용 복합 레진 가열시 물리적 성질의 변화에 관한 실험적 연구 (THE EFFECT OF TEMPERATURE CHANGES ON THE PHYSICAL PROPERTIES OF POSTERIOR COMPOSITE RESINS)

  • 박연홍;민병순;최호영;박상진
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.41-56
    • /
    • 1989
  • The purpose of this study was to examine the effect of temperature dependence of the behavior on the physical properties of posterior composite resins. Three light cure posterior composite resins (Heliomolar, Litefil-P, and P-50) and one chemical cure posterior composite resin (Bisfil-II) were used as experimental materials. Composite resin was placed in a cylindrical brass mold (2.5 mm high and 6.5 mm inside diameter) that was rested on a glass plate. Another flat glass was placed on top of the mold, and the plate was tightly clamped together. After the mold had been filled with the light cure composite material, the top surface was cured for 30 seconds with a light source. Chemical cure resin specimens were made in the same manner as above. Three hundreds and twenty composite resin specimens were constructed from the four composite materials. One hundred and sixty specimens of them were placed in a heater at $50^{\circ}C$, $75^{\circ}C$, $100^{\circ}C$, $125^{\circ}C$, $150^{\circ}C$, $175^{\circ}C$ and $200^{\circ}C$ for 5 minutes or 10 minutes respectively before compressive strengths were measured. Another one hundred and sixty specimens were tested for the diametral tensile strengths in the same way as above. They were randomly divided into eight groups according to the mode of heating methods as follows and stored in distilled water at $37^{\circ}C$ for 24 hours. Group $37^{\circ}C$ - specimens were stored at $37^{\circ}C$ in distilled water for 24 hours. Group $50^{\circ}C$ - specimens were heated at $50^{\circ}C$ after curing. Group $75^{\circ}C$ - specimens were heated at $75^{\circ}C$ after curing. Group $100^{\circ}C$ - specimens were heated at $100^{\circ}C$ after curing. Group $125^{\circ}C$ - specimens were heated at $125^{\circ}C$ after curing. Group $150^{\circ}C$ - specimens were heated at $150^{\circ}C$ after curing. Group $175^{\circ}C$ - specimens were heated at $175^{\circ}C$ after curing. Group $200^{\circ}C$ - specimens were heated at $200^{\circ}C$ after curing. Twenty specimens of each of four composite resins were respectively made by insertion of materials into same mold for examining the dimensional changes between before and after heating. The final eighty specimens were stored in distilled water at $37^{\circ}C$ for 24 hours before testing the dimensional changes. Compressive and diametral tensile strengths were measured crosshead speed 1mm/minute and 500Kg in full scale with a mechanical testing machine (DLC 500 Type, Shimadzu Co., Japan). Dimensional changes were determined by measuring the diametral changes of eighty specimens with micrometer (Mitutoyo Co., Japan). Results were as follows: 1. Diametral tensile strengths of specimens in all groups were increased with time heated compared with control group except for that in group $50^{\circ}C$ and the maximum diametral tensile strength was appeared in the specimen of Litefil-P heated for 10 minutes at $100^{\circ}C$. In heliomolar and P-50, it could be seen in the specimen heated for 10 minutes at $150^{\circ}C$, but in Bisfil-II, it could be found in the specimen heated for 5 minutes at $150^{\circ}C$. 2. Compressive strengths of specimens in all groups was tended to be also increased with time heated but that in group $50^{\circ}C$ and the maximum compressive strengths were showed in the same specimens conditioned as the diametral tensile strengths of four composite materials tested. 3. In Heliomolar, Litefil-P, and Bisfil-II, it was decreased in diameters of resin specimens between before heating and increased in diameters of resin specimens after storing in distilled water, but it was not in P-50. 4. There is little difference in diametral tensile strengths, compressive strengths, and dimensional changes followed by heating the resin specimens for 5 minutes and 10 minutes, but there is no statistical significances.

  • PDF

수중 발열을 위한 Glass/Mo/ZnO/Glass 구조의 박막형 발열체 연구 (A Study on Glass/Mo/ZnO/Glass Thin-film-heaters for Water Heating)

  • 김지우;최두호
    • 마이크로전자및패키징학회지
    • /
    • 제29권1호
    • /
    • pp.43-47
    • /
    • 2022
  • 본 연구에서는 보일러 등에 적용을 하기 위하여 물속에 담군 채 가열할 수 있는 친환경 박막형 히터에 대한 결과를 보고한다. 장수명을 확보하기 위하여 소재 안정성이 높은 Mo 박막(40 nm)을 마그네트론 스퍼터법을 이용하여 Glass 기판상에 증착하였으며 후속 공정 진행 시 Mo 박막의 부식을 방지하기 위하여 상부에 ZnO 박막 (60 nm)을 형성하였다. 이후 투명 접착성을 가지는 PVB (Polyvinyl Butyral)를 이용하여 ZnO 박막 상부에 또 다른 Glass기판을 올려두고 열풍건조기 내에서 150℃의 온도에서 2시간동안 PVB를 경화시키며 접착시켜 Glass/Mo/ZnO/Glass 구조의 수중 히터를 완성하였다. 이렇게 제작한 발열체를 수중에 담근 후 발열 시 물의 온도가 2분 내 50℃까지 상승되는 것을 확인하였으며 미미한 수준의 저항증가가 발생하며 구조적 안정성 또한 확보되었다. 인가 전압의 세기에 따라 발열체의 온도가 제어되기 때문에 보일러에 적용할 때 사용자가 설정하는 온도를 용이하게 제어할 수 있을 것이라 기대된다. 마지막으로, 본 연구에서 제작한 박막형 히터는 반투명의 특성을 가져 심미성을 부여할 수 있어 제품의 부가가치를 더욱 높일 수 있을 것으로 기대된다.