• 제목/요약/키워드: Heat-up time

검색결과 574건 처리시간 0.033초

서울 수도권 지역의 토지 피복 변화가 여름철 도시열섬 강도와 체감온도에 미치는 영향 (Effects of Land Cover Change on Summer Urban Heat Island Intensity and Heat Index in Seoul Metropolitan Area, Korea)

  • 홍선옥;변재영;김도형;이상삼;김연희
    • 대기
    • /
    • 제31권2호
    • /
    • pp.143-156
    • /
    • 2021
  • This study investigates the impacts of land cover change due to urbanization on the Urban Heat Island Intensity (UHII) and the Heat Index (HI) over the Seoul metropolitan area using the Unified Model (UM) with the Met Office Reading Urban Surface Exchange Scheme (MORUSES) during the heat wave from 16, July to 5, August 2018. Two simulations are performed with the late 1980s land-use (EXP1980) and the late 2000s land-use (EXP2000). EXP2000 is verified using Automatic Weather Station (AWS) data from 85 points in the study area, and observation sites are classified into two categories according to the urban fraction change over 20 years; Category A is 0.2 or less increase, and Category B is 0.2 or more increase. The 1.5-m temperature and relative humidity in Category B increase by up to 1.1℃ and decreased by 7% at 1900 LST and 2000 LST, respectively. This means that the effect of the urban fraction changes is higher at night. UHII increases by up to 0.3℃ in Category A and 1.3℃ in Category B at 1900 LST. Analysis of the surface energy balance shows that the heat store for a short time during the daytime and release at nighttime with upward sensible heat flux. As a result of the HI, there is no significant difference between the two experiments during the daytime, but it increases 1.6℃ in category B during the nighttime (2200 LST). The results indicate that the urbanization increase both UHII, and HI, but the times of maximum difference between EXP1980 and EXP2000 are different.

히스테리시스 손실에 의한 괘도부품의 온도 추정에 관한 연구 (A Study on the Estimation of Temperature in Track Components due to Hystresis Loss.)

  • 김형제;김병탁;백운경
    • 동력기계공학회지
    • /
    • 제5권3호
    • /
    • pp.48-55
    • /
    • 2001
  • In many applications. rubber components undergo dynamic stresses or deformations of fairly large magnitude. Since rubbers are not fully elastic, a part of the mechanical energy is converted into heat due to the hysteresis loss. Heat generation without adequate heat dissipation leads to heat build up. i. e. internal temperature rise. The purpose of this paper is to predict temperature rise caused by the hysteresis loss, in a rubber pad subjected to complex dynamic deformation. In this unsteady thermal analysis, the temperature distributions of track components are displayed in contour shapes and the temperature variations of some important nodes are represented graphically with respect to the running time of the tank.

  • PDF

플로어링보드의 흡수성 및 단열성 평가 (Evaluation of water absorption and thermal insulation properties of flooring board)

  • 박철우;임남기;이동건;조영빈
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2021년도 가을 학술논문 발표대회
    • /
    • pp.178-179
    • /
    • 2021
  • Comparing the absorption volume of test pieces immersed over time in room temperature moisture with weight, WF absorbed about 40% more than PLAIN, and PLAIN stopped absorbing after 10 minutes, but WF continued to absorb. It is thought that the woven fabric layer of the core material continued to absorb moisture. In the heat transfer test, the test piece to which only WF was applied had a temperature difference of about 2℃ compared to PLAIN, and when the insulating liquid was sprayed, there was a difference in heat transfer properties of up to 5℃. This is judged to have low heat transfer properties of the basic woven fabric, but the heat insulating liquid also further reduces heat transfer properties.

  • PDF

Analysis and hazard evaluation of heat-transfer fluids for the direct contact cooling system

  • Hong, Joo Hi;Lee, Yeonhee;Shin, Youhwan;Karng, Sarngwoo;Kim, Youngil;Kim, Seoyoung
    • 분석과학
    • /
    • 제19권4호
    • /
    • pp.323-332
    • /
    • 2006
  • This paper discusses several low-temperature heat-tranfer fluids, including water-based inorganic salt, organic salt, alcohol/glycol mixtures, silicones, and halogenated hydrocarbons in order to choose the best heat-transfer fluid for the newly designed direct contact refrigeration system. So, it contains a survey on commercial products such as propylene glycol and potassium formate as newly used in super market and food processing refrigeration. The stability of commercial fluids at the working temperature of $-20^{\circ}C$ was monitored as a function of time up to two months. And organic and inorganic compositions of candidate fluids were obtained by analytical instruments such as ES, XRF, AAS, ICP-AES, GC, and GC-MS. Analysis results indicate that commercial propylene glycol is very efficient and safe heat transfer fluids for the direct cooling system with liquid phase.

Spin-coating에 의한 $Ge_{20}As_{20}Se_{60}$ 비정질 chalcogenide 박막의 제조 및 광특성 분석 (Preparation and Characterization of $Ge_{20}As_{20}Se_{60}$ Amorphous Chalcogenide Thin Film by Spin Coating)

  • 이강구;최세영
    • 한국세라믹학회지
    • /
    • 제37권3호
    • /
    • pp.219-226
    • /
    • 2000
  • Amorphous Ge20As20Se60 chalcogenide thin films were prepared by spin coating technique from mixed solutions of As40Se60 and Ge40Se60 dissolved in ethylenediamine. Films were prepared at a roating speed of 3500 rpm and spinning time was 10 second and heat-treateed at 27$0^{\circ}C$ for 1 hour. The resulting film thickness and RMS roughness were approximately 340 nm and 15$\AA$. Photostructure changes were investigated with 514.5nm Ar+ laser irradiation and heat-treatment. After Ar+ laser irradiation, transmittance and transmission efficiency decreased respectively up to 24.9% at 2.43 eV and 67.5% at 3.27 eV, and absorption edge shifted toward long wavelength. Optical bandgap changed from 2.03 to 1.83 eV, and absoprtion coefficient and absorption efficiency increased up to 0.33$\times$105cm-1 at 3.37eV and 88.3% at 1.31 eV, respectively. These photodarkening state were recovered reversibly by heat-treatment at 27$0^{\circ}C$ for 1 hour. Photodarkening and thermal bleaching effects by laser irradiation and heat-treatment revealed reversible amorphous-to-amorphous transition varying only coordination number.

  • PDF

응축폐열을 이용한 건조 및 온수장치에 관한 연구 (A Study on The Drying and Hot Water System Using Condensation Waste Heat)

  • 박노현;고하영;정진웅;강통삼
    • 대한설비공학회지:설비저널
    • /
    • 제15권4호
    • /
    • pp.362-371
    • /
    • 1986
  • In the normal Refrigeration process, the condensation heat of refrigerant s not been used because of its low-temperature waste heat. To recover the condensation waste heat of R-12 refrigerator, a drying and hot water system was designed and experimented. The results obtained were summarized as follows: 1. As the temperature a temosphere was increased, the temperature of discharge gas of compressor was increased. And the temperature was $80-84^{\circ}C$ for air condensing type and was $68-71^{\circ}C$ for water condensing type during summer. 2. The condensation waste heat could be obtained up to $50-55^{\circ}C$ of drying heat-source and Hot water in summer. In this case, recovered rate was about $73\%$. And the more temperature of drying Heat-source and Hot water were increased, the more a recovered rate were decreased. 3. When comparing drying characteristics of Agro-products in dryer of waste heat utilization and Hot air, there was no quality difference in products. But drying time of the former was 3 Hours longer than the latter. 4. The condensation waste heat of compressor could be applied into the drying of marine products, the predrying of agro-products and making hot water. And showed high possibility of the waste heat using in low-temperature storage.

  • PDF

점탄성유체의 저항 및 열전달 감소현상과 퇴화의 영향에 관한 연구 (A Study on the Drag and Heat Transfer Reduction Phenomena and Degradation Effects of the Viscoelastic Fluids)

  • 엄정섭;전찬열;유상신
    • 설비공학논문집
    • /
    • 제2권1호
    • /
    • pp.37-48
    • /
    • 1990
  • The drag and heat transfer reduction phenomena and degradation effects of drag reducing polymer solutions which are known as the viscoelastic fluids are investigated experimentally for the turbulent circular tube flows. Two stainless steel tubes are used for the experimental flow loops. Aqueous solutions of Polyacrylamide Separan AP-273 with concentrations from 300 to 1000 wppm are used as working fluids. Flow loops are set up to measure the friction factors and heat transfer coefficients of test tubes in the once-through system and the recirculating flow system. Test tubes are heated by power supply directly to apply constant heat flux boundary conditions on the wall. Capillary tube viscometer and falling ball viscometer are used to measure the viscous characteristics of fluids and the characteristic relaxation time of a fluid is determined by the Powell-Eyring model. The order of magnidude of the thermal entrance length of a drag reducing polymer solution is close to the order of magnitude of the laminar entrance length of Newtonian fluids. Dimensionless heat transfer coefficients of the viscoelastic non-Newtonian fluids may be represented as a function of flow behavior index n and newly defined viscoelastic Graetz number. As degradation continues viscosity and the characteristic relaxation time of the testing fluids decrease and heat transfer coefficients increase. The characteristic relaxation time is used to define the Weissenberg number and variations of friction factors and heat transfer coefficients due to degradation are presented in terms of the Weissenberg number.

  • PDF

판형 열교환기 Full-scale 해석을 위한 1차원 유동 네트워크 모델 및 ε-NTU 모델의 수치적 연구 (NUMERICAL STUDY FOR THE FULL-SCALE ANALYSIS OF PLATE-TYPE HEAT EXCHANGER USING ONE-DIMENSIONAL FLOW NETWORK MODEL and ε-NTU METHOD)

  • 김민성;민준기;하만영
    • 한국전산유체공학회지
    • /
    • 제19권1호
    • /
    • pp.47-56
    • /
    • 2014
  • Since a typical plate heat exchanger is made up of a huge number of unitary cells, it may be impossible to predict the aero-thermal performance of the full scale heat exchanger through three-dimensional numerical simulation due to the enormous amount of computing resources and time required. In the present study, a simple flow-network model using the friction factor correlation and a thermal-network model based on the effectiveness-number of transfer units (${\varepsilon}$-NTU) method has been developed. The complicated flow pattern inside the cross-corrugated heat exchanger has been modeled into flow and thermal networks. Using this model, the heat transfer between neighboring streams can be considered, and the pressure drop and the heat transfer rate of full-scale heat exchanger matrix are calculated. In the calculation, the aero-thermal performance of each unitary cell of the heat exchanger matrix was evaluated using correlations of the Fanning friction factor f and the Nusselt number Nu, which were calculated by unitary-cell CFD model.

초임계 유체에서 L-Lactide의 Scale-up 중합 (Scale-up Polymerization of L -Lactide in Supercritical Fluid)

  • ;김세윤;최동훈;김수현
    • 폴리머
    • /
    • 제35권4호
    • /
    • pp.284-288
    • /
    • 2011
  • 초임계 유체에서 poly(L-Lactide) (PLLA)의 산업화 생산 공정 개발을 위한 예비 연구로 1-dodecano/stannous 2-ethyl-hexanoate(DoOH/Sn(Oct)$_2$)를 개시제로 하여 chlorodifluoromethane 초임계 용매 하에서 락티드의 개환 중합을 실시하였다. 중합은 3 L 반응기를 사용하였으며 중합시간, 온도, 압력 및 단량체와 초임계 용액 농도에 따른 중합거동을 관찰하였다. 중합시간이 5시간 경과할 경우 얻어진 중합체의 반응 수율 및 분자량은 각각 72%, 68000 g/mol이었다. 단량체의 농도가 증가할수록 중합체의 수율 및 분자량은 증가하였으며 최대 각각 97%, 144000 g/mol이 얻어졌다. 반응기의 압력이 130에서 240 bar로 증가할 경우 PLLA의 수율 및 분자량이 증가하였다. 얻어진 중합체의 열안정성을 향상시키기 위해 메탄올 처리 및 진공 처리를 실시하였다. 그 결과 두 가지 방법 모두 PLLA의 열안정성을 향상시켰다.

Numerical study of the flow and heat transfer characteristics in a scale model of the vessel cooling system for the HTTR

  • Tomasz Kwiatkowski;Michal Jedrzejczyk;Afaque Shams
    • Nuclear Engineering and Technology
    • /
    • 제56권4호
    • /
    • pp.1310-1319
    • /
    • 2024
  • The reactor cavity cooling system (RCCS) is a passive reactor safety system commonly present in the designs of High-Temperature Gas-cooled Reactors (HTGR) that removes heat from the reactor pressure vessel by means of natural convection and radiation. It is one of the factors responsible for ensuring that the reactor does not melt down under any plausible accident scenario. For the simulation of accident scenarios, which are transient phenomena unfolding over a span of up to several days, intermediate fidelity methods and system codes must be employed to limit the models' execution time. These models can quantify radiation heat transfer well, but heat transfer caused by natural convection must be quantified with the use of correlations for the heat transfer coefficient. It is difficult to obtain reliable correlations for HTGR RCCS heat transfer coefficients experimentally due to such a system's size. They could, however, be obtained from high-fidelity steady-state simulations of RCCSs. The Rayleigh number in RCCSs is too high for using a Direct Numerical Simulation (DNS) technique; thus, a Reynolds-Averaged Navier-Stokes (RANS) approach must be employed. There are many RANS models, each performing best under different geometry and fluid flow conditions. To find the most suitable one for simulating an RCCS, the RANS models need to be validated. This work benchmarks various RANS models against three experiments performed on the HTTR RCCS Mockup by the Japanese Atomic Energy Agency (JAEA) in 1993. This facility is a 1/6 scale model of a vessel cooling system (VCS) for the High Temperature Engineering Test Reactor (HTTR), which is operated by JAEA. Multiple RANS models were evaluated on a simplified 2d-axisymmetric geometry. They were found to reproduce the experimental temperature profiles with errors of up to 22% for the lowest temperature benchmark and 15% for the higher temperature benchmarks. The results highlight that the pragmatic turbulence models need to be validated for high Rayleigh natural convection-driven flows and improved accordingly, more publicly available experimental data of RCCS resembling experiments is needed and indicate that a 2d-axisymmetric geometry approximation is likely insufficient to capture all the relevant phenomena in RCCS simulations.