• 제목/요약/키워드: Heat-transfer coefficient

검색결과 1,586건 처리시간 0.056초

보론강 핫 프레스 포밍 공정에 대한 가상생산 응용 및 검증 (Application and Verification of Virtual Manufacturing to Hot Press Forming Process with Boron Steel)

  • 서영성;지민욱;이경훈;김영석
    • 한국자동차공학회논문집
    • /
    • 제18권2호
    • /
    • pp.61-66
    • /
    • 2010
  • A virtual manufacturing system that is composed of JMatPro, a material modeler and $DEFORM^{TM}$-HT, a finite element package is applied to the hot press forming process: high temperature material properties for each phase such as flow stress, elastic modulus, Poisson's ratio, thermal expansion coefficient, in addition to TTT curve are predicted by JMatPro and taken into $DEFORM^{TM}$-HT to predict the material behavior considering phase transformation and heat transfer simultaneously. In order to verify the accuracy of computation, the residual stress and the springback were compared with the experimental measurements. Both the predicted and measured principal residual stresses and amount of springback were in good agreement. It was also found that the residual stresses generated from hot press forming are not negligible as it has been generally assumed, although the springback deformation is quite small.

가스아토마이징된 $Al_{87.3}misch$ $metal_{8.3}Ni_{4.4}$ 분말의 냉각속도와 수지상 가지 가격에 관한 고찰 (A Study on Cooling Rate and Dendrite Arm Spacing of Gas Atomized $Al_{87.3}misch$ $metal_{8.3}Ni_{4.4}$ Powder)

  • 김지훈;예병준;김영환
    • 한국주조공학회지
    • /
    • 제19권1호
    • /
    • pp.54-65
    • /
    • 1999
  • The present work is an attempt to evaluate the relationship between dendrite arm spacing and average cooling rate in gasatomized $Al_{87.3}misch$ $metal_{8.3}Ni_{4.4}$ powder by means of the following methods. One is calculation of heat transfer coefficient and average cooling rate, which are derived from estimated particle velocity during gas-atomization. The other is measurement of secondary dendrite arm spacing, which are observed on the particle surface. Then, we make experimental equation for this relationship in case of permanent mold casting and compare it with similar equation in case of rapidly solidified powder. Both average cooling rates and solidification rates are considered to represent the variance of dendrite arm spacings in two types soidification route. Even though there is a considerable difference in each average cooling rate, the dendrite arm spacing values are similar in two cases; particle diameter, $100\;{\mu}m$, and casting width, 2.05 mm. It is because that each solidification route has similar solidification rate.

  • PDF

90° 곡관에서의 비축대칭 끝벽면을 이용한 열유동 환경 개선 (Improvement of the Aerothermal Environment for a 90° Turning Duct by the Nonaxisymmetric Endwall)

  • 조종재;김귀순
    • 한국추진공학회지
    • /
    • 제15권4호
    • /
    • pp.1-10
    • /
    • 2011
  • 본 논문에서는 가스터빈 유로의 열유동 환경을 개선하기 위해 끝벽면의 형상에 대한 최적화를 수행하였으며, 비축대칭 끝벽면을 이용한 방법을 적용하였다. 터빈 유로를 모사하기 위해 $90^{\circ}$ 곡관을 이용하였다. 터빈 유로에서의 전압력 손실과 유로 끝벽면에서의 열전달 계수를 최소화하는 비축대칭 끝벽면형상 도출을 연구의 목적으로 하였으며, 최적화 과정의 효율성을 위해 근사 최적화 기법을 적용하였다. 연구결과를 통해, 최적화된 비축대칭 끝벽면에 의한 상당한 공력열환경 개선을 확인할 수 있었다.

건축물 설계변수의 상관관계 분석을 통한 CO2 배출저감 방안 (A CO2 Emission Reduction Method through Correlation Analysis of Design Parameters in Buildings)

  • 이현우;채민수
    • 한국태양에너지학회 논문집
    • /
    • 제31권1호
    • /
    • pp.100-106
    • /
    • 2011
  • This study proposes a $CO_2$ emission reduction method through correlation analysis of a sample building. First, energy saving factors of heating, cooling, lighting were determined for the correlation analysis and $CO_2$ emission contribution rate of the design parameters have been analyzed. Then optimal combination of each design parameter has been drawn. Heat transfer coefficient of walls and windows, air permeability, windows area ratio, and shading devices were selected as applicable energy saving factors of the sample building. Also computer simulation was conducted using experimental design by Orthogonal Arrays of the statistical method. And the contribution rate was estimated by Analysis of Variance-ANOVA. As a result, the $CO_2$ emission in heating was reduced to 51.9%; in cooling to 16.8%; and in lighting to 2% compared to the existing building. The majority of the reduction was presented by heating energy.

제빙관의 형태변화에 따른 제빙특성 (Ice Making Characteristics According to Changing Shape of Ice Making Tube)

  • 정은호;박기원
    • 설비공학논문집
    • /
    • 제21권5호
    • /
    • pp.291-296
    • /
    • 2009
  • Ice accumulating system patterned ice-an-coil is the way of refrigerating regenerative materials on the surface of copper-tube inserted into the inside of ice-storage. The study experimented to understand ice-an-coil type ice making characteristics according to changing shape of ice making tube. The experiment were carried out under various conditions, that used brine temperature($-l0^{\circ}C$, $-6^{\circ}C$) brine flow rate(l.0m/s, 1.8m/s) and inlet water temperature($6^{\circ}C$, $12^{\circ}C$) etc. Mass of ice per making area increased according to the decrease of the brine temperature and inlet water temperature, but that was increased according to the increase of the brine flow rate. And I set up two hypotheses and compared the capacity of ice-making of the two cases; each had the same thermal area and one had an round-shaped copper tube but the other had an oval-shaped copper tube.

태양열 온실 난방에 대한 최척 집열 면적과 경제성 평가 (Optimum Collector Area and Economic Evaluation for the Greenhouse Heating)

  • 박이동;김규인
    • 태양에너지
    • /
    • 제2권1호
    • /
    • pp.49-58
    • /
    • 1982
  • Aim of this study was to obtain the heating performance and the economic evaluation on solar heating system for greenhouse which area of floor was $90m^2$. For heating performance effective solar energy for the greenhouse was compared with overall heating loads including coefficient of heat transfer and conduction. And the economic evaluation solar heating system was evaluated by comparison its initial investiment costing with oil saving cost. Initial investiment costing included collector cost, storage cost, piping cost, control system cost and miscellaneous costs which included pumps, motors etc. The contents of this study included the survey of climate conditions for solar heating, long-term collector performance and optimum collector area of solar heating system in existing greenhouse. The results are follows: 1. Average horizontal radiation during winter was $2,434Kcal/m^2$ day which was the highest value in this country, so the climate conditions of Suwon was suitable for solar heating. 2. Resulting calculation of the optimum collector area was $30m^2$ and the solar energy accounted for 30% of the overall heating load. 3. The capacity of storage tank required 60 liter per unit area ($m^2$) of solar collector.

  • PDF

PCB 재질 및 Via hole 구성에 따른 LED 패키지의 특성 분석 (Analysis of LED Package Properties by PCB Material and Via-hole Construction)

  • 이세일;양종경;김성현;이승민;박대희
    • 전기학회논문지
    • /
    • 제59권11호
    • /
    • pp.2038-2042
    • /
    • 2010
  • In this paper, we confirmed the thermal & optical properties for improving the heat transfer coefficient by changing the via hole size and in FR4 PCB with the same area. Osram 1W power LED Package (Golden Dragon) was used and the K-factor which is relative constant between LED junction temperature and forward bias was measured with power source meter(KEITHLEY 2430) to measure the thermal resistance from PCB configuration. As results, thermal resistance in metal PCB came out to the lowest as $26 [^{\circ}C/W]$ and thermal resistance in FR4 PCB without via-holes emerged as the highest as $69 [^{\circ}C/W]$. However thermal resistance of FR4 PCB could have decreased until $32[^{\circ}C/W]$ in 0.6 mm by using the via hole. Also, the luminous flux could have improved, too.

2성분 혼합물질의 층류 막비등에서 복사열전달의 효과 (Effect of Radiation on Laminar Film Boiling of Binary Mixtures)

  • 성현찬;김경훈
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.942-951
    • /
    • 2004
  • This paper presents the results of a theoretical study of the effect of radiation during free convective laminar film boiling for methanol/water binary mixtures on an isothermal vertical wall at atmospheric pressure. With the well-known boundary layer theory as a basis, a theoretical model has been formulated into consideration for mass diffusion at liquid phase. The equations are numerically solved by a similarity method to investigate the effects of radiation emissivity on the surface with various parameters such as wall superheat and composition of more volatile component at liquid phase far from the wall. From the results, the distributions of the physical quantifies are investigated in both phases. New correlations are proposed to predict the heat transfer coefficient of binary mixtures. It is shown that the proposed correlations are in good agreement with numerical results and with Bromley's correlation within maximum $11\%$ errors. It is also found that as the wall superheat is increased, radiation effect becomes more important.

Analyses of Precooling Parameters for a Bottom Flooding ECCS Rewetting Velocity Model

  • Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.12-21
    • /
    • 1981
  • 지난번 이미 다른곳에 발표한 재침수속도공식(rewetting velocity model)에 관한 논문을 더 확충하였다. 앞서 발표한 재침수속도 공식을 사용하려면 ø의 값을 미리 알고 있어야한다. ø값을 모를 때에는 film boiling 열전달계수 ( $h_{df}$ )와 fog-film길이 (ι)의 자료가 있어야 한다. 이러한 자료를 제공하기 위해서, 먼저 브롬리(Bromley)의 공식을 수정하여 보다 높은 압력조건하에서의 $h_{df}$ 값을 구하였다. 그리고, 지난번 사용한 자료보다 훨씬 더 충실한 PWR-FLECHT 자료를 사용하여 ø와 ι과 같은 precooling 계수들의 합을 더 확충하여 놓았다. 이리하여, 재침수속도공식의 응용 가능한 영역을 더 확대하였다.

  • PDF

Assessment of thermal fatigue induced by dryout front oscillation in printed circuit steam generator

  • Kwon, Jin Su;Kim, Doh Hyeon;Shin, Sung Gil;Lee, Jeong Ik;Kim, Sang Ji
    • Nuclear Engineering and Technology
    • /
    • 제54권3호
    • /
    • pp.1085-1097
    • /
    • 2022
  • A printed circuit steam generator (PCSG) is being considered as the component for pressurized water reactor (PWR) type small modular reactor (SMR) that can further reduce the physical size of the system. Since a steam generator in many PWR-type SMR generates superheated steam, it is expected that dryout front oscillation can potentially cause thermal fatigue failure due to cyclic thermal stresses induced by the transition in boiling regimes between convective evaporation and film boiling. To investigate the fatigue issue of a PCSG, a reference PCSG is designed in this study first using an in-house PCSG design tool. For the stress analysis, a finite element method analysis model is developed to obtain the temperature and stress fields of the designed PCSG. Fatigue estimation is performed based on ASME Boiler and pressure vessel code to identify the major parameters influencing the fatigue life time originating from the dryout front oscillation. As a result of this study, the limit on the temperature difference between the hot side and cold side fluids is obtained. Moreover, it is found that the heat transfer coefficient of convective evaporation and film boiling regimes play an essential role in the fatigue life cycle as well as the temperature difference.