Analyses of Precooling Parameters for a Bottom Flooding ECCS Rewetting Velocity Model

  • Published : 1981.03.01

Abstract

An extension work of the previous paper on the rewetting velocity model is presented. Application of the rewetting velocity model presented elsewhere requires a priori values of ø. In the absence of ø values, film boiling heat transfer coefficient ( $h_{df}$ ) and fog-film length (ι) data are needed. To provide these informations, a modified Bromley's correlation is first derived and used to obtain $h_{df}$ values at higher pressure conditions. In addition, the analysis of the precooling parameters, such as ø and ι is further extended using much more expansive PWR FLECHT data. Thus, the applicable range of the rewetting velocity model is further expanded in this work.

지난번 이미 다른곳에 발표한 재침수속도공식(rewetting velocity model)에 관한 논문을 더 확충하였다. 앞서 발표한 재침수속도 공식을 사용하려면 ø의 값을 미리 알고 있어야한다. ø값을 모를 때에는 film boiling 열전달계수 ( $h_{df}$ )와 fog-film길이 (ι)의 자료가 있어야 한다. 이러한 자료를 제공하기 위해서, 먼저 브롬리(Bromley)의 공식을 수정하여 보다 높은 압력조건하에서의 $h_{df}$ 값을 구하였다. 그리고, 지난번 사용한 자료보다 훨씬 더 충실한 PWR-FLECHT 자료를 사용하여 ø와 ι과 같은 precooling 계수들의 합을 더 확충하여 놓았다. 이리하여, 재침수속도공식의 응용 가능한 영역을 더 확대하였다.

Keywords