• 제목/요약/키워드: Heat-load test

검색결과 365건 처리시간 0.027초

석영 가열램프의 열 유속 특성 파악을 통한 고온 구조시험의 열 하중 설계에 관한 연구 (A Study on Heat Flux Characteristics of Tubular Quartz Lamp for Thermal Load Design of High Temperature Structural Test)

  • 김준혁
    • 한국군사과학기술학회지
    • /
    • 제25권4호
    • /
    • pp.355-363
    • /
    • 2022
  • Development of supersonic flying vehicle is one of the most latest issue in modern military technology. Specifically, structural integrity of supersonic flying vehicle can be verified by high temperature structural test. High temperature structural test is required to consider thermal load caused by aerodynamic heating while applying structural load simultaneously. Tubular quartz lamps are generally used to generate thermal load by emitting infrared radiation. In this study, modified heat flux model of tubular quartz lamp is proposed based on existing model. Parameters of the proposed model are optimized upon measured heat flux in three dimensions. Finally, thermal load of plate specimen is designed by the heat flux model. In conclusion, it is possible to predict heat flux applied on plate specimen and desired thermal load of high temperature structural test can be obtained.

기기냉각수 폐열회수용 흡수식 히트펌프의 부분부하 성능에 관한 연구 (A Study on Partial Load Performance of Absorption Type Heat Pump for Waste Heat Recovery of Closed Cooling Water)

  • 박병철;김태형;김광수
    • 에너지공학
    • /
    • 제28권2호
    • /
    • pp.47-54
    • /
    • 2019
  • 복합화력발전소 에너지절감 사업으로 폐열회수용 흡수식 히트펌프가 설치됨에 따라 부분부하(Partial Load)에서의 성능 데이터 확인을 위해 성능시험을 실시하였다. 부분 부하에서 히트펌프 가동에 따른 운전 데이터 변화는 다음과 같다. 기기냉각수(CCW) 배열 및 배열회수열교환기(HRSG)로부터 공급되는 저압증기(LP STM)의 일부가 히트펌프의 열원으로 공급되므로 지역난방열 생산이 증대된다. 그러나 증기터빈으로 공급되는 저압증기의 유량감소에 따라 증기터빈 출력이 감소된다. 또한 고압 지역난방열교환기(HP-DH) 및 저압 지역난방열교환기(LP-DH)로 공급되는 고압터빈(HPT) 배기증기의 유량 저하에 따라 HP-DH 및 LP-DH의 열생산량도 감소한다. 부분부하에서는 정격부하 대비 히트펌프에 운전에 따른 터빈 출력 저하가 큰 것으로 나타났으며, 이에 따라 부분 부하에서는 발전소 전체의 열 생산 증가량, 전기출력 감소량을 종합적으로 고려하여 히트펌프 운전 여부를 결정해야 한다.

열방출량 (Heat Rejection Rate)을 이용한 PTC (Powertrain Cooling) 성능 추정 (Estimation of PTC (Powertrain Cooling) Performance with Heat Rejection Rate)

  • 민선기
    • 한국산학기술학회논문지
    • /
    • 제16권5호
    • /
    • pp.3030-3034
    • /
    • 2015
  • 새로운 엔진과 차량을 개발하여 엔진을 차량에 탑재할 때, 중요하게 고려해야 할 사항 중의 하나는 냉각 성능이다. 만약 냉각 성능이 열악하다면 엔진은 과열되어 파손되게 된다. 그러나 자동차회사에서 일반적으로 엔진은 차량보다 훨씬 빠른 시기에 개발이 진행되게 되어 엔진을 차량에 탑재한 조건에서 냉각 성능을 시험할 수 없다. 본 연구에서는 몇 가지 시험과 계산 결과를 이용하여 엔진의 냉각 성능을 추정하였다. 첫 번째로 엔진의 열정산 시험이 진행되었다. 두 번째로 냉각수 유동 시험이 진행되었다. 이 시험에서 라디에이터로 유입되는 유량을 구할 수 있다. 그리고 차량의 냉각 시험 성능 조건으로부터 차량의 부하와 속도를 구하고, 이로부터 엔진의 토크와 rpm이 계산되었다. 그리고 이러한 결과를 비교하여 엔진의 냉각 성능이 추정되었다.

looped wire의 하중변형도와 열처리에 의한 변화 (THE LOAD DEFLECTION RATE OF LOOPED WIRE AND ITS CHANGE BY HEAT TREATMENT)

  • 이용국
    • 대한치과교정학회지
    • /
    • 제16권1호
    • /
    • pp.133-144
    • /
    • 1986
  • This study was conducted to evaluate the effects of loop formation and heat treatment upon the elastic properties of orthodontic wires. The specimens selected were .016', .018', .016x.022', and .018x.022' sized stainless steel (standard) and cobalt-chromium-nickel wires, and were divided into 7 groups as; 1. straight non-heat treated 2. U looped non-heat treated 3. L looped non-heat treated 4. Circle looped non-heat treated 5. U looped heat treated 6. L looped heat treated 7. Circle looped heat treated Heat treatment was performed in Big Jane furnace at 850' F for 3 minutes. The elastic limit and the elastic range of each specimen were determined by bending test, and load deflection rate was computed from those values. The findings were as follows; 1. The formation of loop resulted in increased load-deflection rate for both stainless steel and cobalt-chromium-nickel wires. 2. The heat treated group showed higher load-deflection rate than non-heat treated group, which was more apparent in cobalt-chromiumnickel wire than in stainless steel wire. 3. L loop had the highest load-deflection rate among 3 types of loops, followed by U loop and circle loop. 4. The specimens with greater diameter displayed the more increase in load-deflection rate by looping and heat treatment.

  • PDF

축력비 조건에 따른 철근콘크리트기둥의 내화성능에 관한 연구 (A Study on the Fire Resistance Performance of Reinforced Concrete Columns according to Axial Load Ratio)

  • 황규재;조범연;여인환
    • 한국화재소방학회논문지
    • /
    • 제27권6호
    • /
    • pp.26-31
    • /
    • 2013
  • 본 연구의 목적은 성능적 내화설계를 기반으로 한 철근콘크리트 기둥의 내화성능 평가를 최종 목표로 철근콘크리트 기둥의 열전달 해석을 통한 온도분포와 재하가열실험을 통한 수축량으로 적정 축력비를 도출하여 성능설계를 위한 기초 자료로 활용하고자 하는데 있다. 편심이 전혀 없는 순수축력을 기준으로 축력비 0.30, 0.35, 0.40, 0.47을 재하한 결과, 0.40 이상의 축력비를 확보하여야 내화성능을 만족할 수 있다고 판단하였다.

건축물의 적재가연물 특성에 관한 연구 -우체국 적재가연물의 연소성상 - (Characterization of Live Fire Load in Buildings - Heat Release Characteristics of Typical Live Fire Load in Post Office Building -)

  • 남동군;장곡견웅이;사공성호;정종진
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.7-10
    • /
    • 2008
  • Heat release characteristics of live fire load are an important parameter for performance oriented fire safety design of a building. While investigations have been carried out on the fire load and its burning behavior in office, residential and commercial buildings and so on, little effort has been paid for the rational treatment of fire load in post office buildings in Japan. In this report, burning behavior of typical combustible objects in post office buildings are studied by measuring heat release rates of plastic palettes with and without postal envelopes or packages and special containers loading numbers of palettes. The test results suggest that dynamic heat release rate is highly dependent on the condition of palettes especially if they load appropriate amount of postal envelopes or not.

  • PDF

멀티버너 보일러용 열교환기 모듈 특성 시험 - 부하별 특성 결과 - (Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler - Part Load Test Results -)

  • 김종진;최규성;기호충;강새별
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1025-1030
    • /
    • 2008
  • We develop heat exchanger modules for a multi-burner boiler. The heat exchanger module is kind of a heat recovery steam generator (HRSG). This heat recovery system has 4 heat exchanger modules. The 1st module consists of 27 bare tubes due to high temperature exhaust gas and the others consist of 27 finned tubes. The maximum steam pressure of each module is 10 bar and tested steam pressure is 4 bar. In order to test these heat exchanger modules, we make a 0.5t/h flue tube boiler (LNG, $40\;Nm^3/h$). The test results of 100% boiler load show that heat transfer rate of 1st module is 49.7 Mcal/h which is 34% of total heat transfer rate and that of 2nd module is 82.6 Mcal/h which is 57% of total heat transfer rate. The reason of higher the heat transfer rate of 2nd module than that of 1st module is that the 2nd heat exchanger module has finned tubes instead of bare tube. The boiler load 50% results show that only 2 heat exchanger modules are needed to extract the heat from the flue gas to water. From this result, it is very important of optimum design of the first finned tube among all water tubes.

  • PDF

고온초전도 응용기기용 과냉질소 냉각시스템의 냉각특성 (Characteristics of Sub-cooled Nitrogen Cryogenic System for Applied High-Tc Superconducting Devices)

  • 강형구;김형진;배덕권;안민철;윤용수;장호명;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권1호
    • /
    • pp.38-42
    • /
    • 2004
  • The cryogenic system for 6.6 kV/200 A inductive superconducting fault current limiter (SFCL) was developed at Yonsei university in 2003. The sub-cooled nitrogen cryogenic system could be applied to not only SFCL but also many other applied high-Tc superconducting (HTS) devices like superconducting motor, superconducting generator and superconducting magnetic energy storage (SMES). Generally, the cooling capacity of GM-cryocooler depends on the load temperature. Therefore it is necessary to perform the cooling capacity test at no load condition to calculate the exact cooling power and heat load of cryogenic system. In this research, the cooling capacity test of GM-cryocooler was executed and the heat load of developed cryogenic system was calculated. The long run operation test results of sub-cooled nitrogen cryogenic system were successful in pressure and temperature condition. Moreover, the design and fabrication method of cryogenic system were introduced and the test results were described.

건축물 용도별 내부 발열부하에 따른 수열원, 지열원 및 하이브리드 히트펌프 시스템의 에너지 성능 비교 분석 (Comparative Analysis of Energy Performance of Hydrothermal, Geothermal Source and Hybrid Heat Pump System According to Internal Heat Load for Office, School and Smart Farm)

  • 박시훈;민준기
    • 한국지열·수열에너지학회논문집
    • /
    • 제18권3호
    • /
    • pp.19-30
    • /
    • 2022
  • In this study, comparative analysis of energy performance in Taebaek city, a test area, by applying hydrothermal, geothermal source and hybrid heat pump system to office, school and smart farms with different internal heat loads. The conclusion is as follows. In the load characteristics by use of buildings, it was found that office had a large cooling load compared to heating load, school had a large heating load compared to cooling load, and smart farm had only cooling load year-round. Performance analysis of the heat pump system in office shows that the cooling COP of the hydrothermal source is 5.12% and the heating COP is 3.22% lower based on the geothermal source, the cooling COP of the hybrid is 0.41% higher, and the heating COP is the difference in performance appeared sparsely. The performance analysis of the heat pump system in school showed that the cooling COP of the hydrothermal source was 10.44% and the heating COP 3.22% lower based on the geothermal source, and the performance difference between the hybrid cooling and heating COP was insignificant. Heat pump system performance analysis in smart farm only occurred with cooling load. Based on geothermal sources, the cooling COP of the hydrothermal source was 46% and the cooling COP of the hybrid was 19.65%, respectively.

FRP Confinement of Heat-Damaged Circular RC Columns

  • Al-Nimry, Hanan Suliman;Ghanem, Aseel Mohammad
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권1호
    • /
    • pp.115-133
    • /
    • 2017
  • To investigate the effectiveness of using fiber reinforced polymer (FRP) sheets in confining heat-damaged columns, 15 circular RC column specimens were tested under axial compression. The effects of heating duration, stiffness and thickness of the FRP wrapping sheets were examined. Two specimen groups, six each, were subjected to elevated temperatures of $500^{\circ}C$ for 2 and 3 h, respectively. Eight of the heat-damaged specimens were wrapped with unidirectional carbon and glass FRP sheets. Test results confirmed that elevated temperatures adversely affect the axial load resistance and stiffness of the columns while increasing their ductility and toughness. Full wrapping with FRP sheets increased the axial load capacity and toughness of the damaged columns. A single layer of the carbon sheets managed to restore the original axial resistance of the columns heated for 2 h yet, two layers were needed to restore the axial resistance of columns heated for 3 h. Glass FRP sheets were found to be less effective; using two layers of glass sheets managed to restore the axial load carrying capacity of columns heated for 2 h only. Confining the heat-damaged columns with FRP circumferential wraps failed in recovering the original axial stiffness of the columns. Test results confirmed that FRP-confining models adopted by international design guidelines should address the increased confinement efficiency in heat-damaged circular RC columns.