• 제목/요약/키워드: Heat recovery

검색결과 997건 처리시간 0.075초

루프형 2상 유동 열사이폰 열교환기에 관한 연구 (Study on Two-Phase Loop Thermosyphon Heat Exchanger)

  • 이기우;박기호;이석호
    • 설비공학논문집
    • /
    • 제14권9호
    • /
    • pp.717-724
    • /
    • 2002
  • A heat exchanger (100,000 W) using two-phase loop thermosyphons (TLT) was developed as a waste heat recovery system. An experimental and simulation study was carried out on the heat transfer characteristics of TLT heat exchanger, and the results from the experiments were used to see the possibility which the TLT heat exchanger could be an alternate solution for waste heat recovery system. The experimental results showed the provisional results as a waste heat recovery system. Also computer simulation code can predict the TLT system about the effects of various variables for the operation. Computer simulation results based on the thermal resistance networks were compared with the experimental results. The study clearly shows that the computer simulation for the TLT heat exchanger can Predict the most cases of the affecting parameters involved, provided that correct empirical correlations are used.

폐용제 회수용 이중관형 열교환기 특성 해석 (Analysis of a Double Pipe Heat Exchanger for Waste Solvent Recovery)

  • 구재현;이재근
    • 자원리싸이클링
    • /
    • 제9권3호
    • /
    • pp.13-21
    • /
    • 2000
  • 본 연구는 폐용제를 가열, 증발 및 음축과정을 거쳐 용제를 회수하는 시스템의 열교환기 해석에 관한 것으로, 고온 열매체유로 가열되는 이중관형 열교환기를 사용하여 용제 증발과정의 열전달 특성을 분석하고 용제유량과 가열온도에 따라 물, 벤젠 및 알칼벤젠의 증발을 위해 요구되는 전열면적을 분석하였다. 폐용제 회수장치는 용제 공급펌프 이중관형 열교환기, 진공 스프레이 챕버 및 응축기동으로 구성되며, 이중관형 열교환기는 용제액을 열적 포화온도를 가열시키는 구간과 포화된 용제액을 증발시키는 구간으로 구성된다. 관 내 용제의 증발을 위한 전열면적을 열평형 모델링에 의해 예측하였고, 이중관형 열교화기의 관 내 온도분포 측정을 통해 이론값과 비교 분석하였다. 용제유량 0.1~0.51l/mm 및 가열온도 130~$260^{\circ}C$의 범위에서 용제유향 증가 및 가열온도 감속에 따라 단위전열면적당 열전달양이 감소하기 때문에 용제 증발을 위한 전열면적은 증가하였다. 관 내 용제 증발을 위한 전열면적의 이론적 분석결과는 측정값과 일치하였으며, 이중관형 열교환기를 사용한 폐용제의 증발과정을 통해 용제를 회수하는 기술에 적용이 가능하다.

  • PDF

아스펜 플러스를 이용한 폭발성 가스 건식 연소 처리공정의 열회수 모델링 및 엑서지 분석 (Heat Recovery Modeling and Exergy Analysis of Dry Combustion Process for Explosive Gas Treatment Using Aspen Plus)

  • 최용만;최창식;홍범의;조성수;김용진;김학준
    • 한국대기환경학회지
    • /
    • 제33권5호
    • /
    • pp.521-528
    • /
    • 2017
  • In the combustion treatment of explosive gases with a high heating value such as $H_2$ and $NH_3$ used in semiconductor and chemical processes, the heat recovery modeling and exergy analysis of the process using the Aspen Plus simulator and its thermodynamic data were performed to examine the recovery of high temperature thermal energy. The heat recovery process was analyzed through this process modeling while the exergy results clearly confirmed that the rigorous reaction mainly occurs in the condenser and the chamber. In addition, the process modeling demonstrated that approximately 95% of the exergy is destructed on the basis of the exergies injected and the exergy being exhausted. Using the exergy technique, which can quantitatively analyze the energy, we could understand the energy flow in the process and confirm that our heat recovery process was efficiently designed.

자동차 냉각수 폐열회수 열전발전 시스템의 성능에 관한 연구 (An Experimental Study on Thermoelectric Generator Performance for Waste Coolant Recovery Systems in Vehicles)

  • 이대웅
    • 설비공학논문집
    • /
    • 제26권7호
    • /
    • pp.329-334
    • /
    • 2014
  • This study indicated the possibility of energy regeneration from waste coolant heat, by using thermoelectric generation integrated with heat pipe. The internal combustion engine rejects more than 60% wasteful energy to the atmosphere by heat. The thermoelectric generator has recently been studied, to convert the energy from engine waste heat into electricity. For coolant waste heat recovery, a thermoelectric generator was investigated, to find out the possibility of vehicular application. Performance characteristics were conducted with various test conditions of coolant temperature, coolant mass flow rate, air temperature, and air velocity, with the thermoelectric generator installed either horizontally or vertically. Experimental results show that the electric power and conversion efficiency increases according to the temperature difference between the hot and cold side of the thermoelectric generator, and the coolant flow rate of the hot side heat exchanger. Performance improvement can be expected by optimizing the heat pipe design.

전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구 (An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger)

  • 장영근
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

핀 형상에 따른 폐열회수용 핀-튜브 열교환기의 성능분석 (Performance Analysis of Fin-Tube Heat Exchangers with Various Fin Shapes for Waste Gas Heat Recovery)

  • 맹재훈;구병수;전용두;이금배
    • 설비공학논문집
    • /
    • 제23권9호
    • /
    • pp.627-632
    • /
    • 2011
  • As an innovative effort to secure economically viable heat recovery system, various fin shapes for industrial fin-tube heat exchangers have been studied for better performance. In this study, the waste gas heat recovery from four different fin shapes was experimentally performed for heat transfer rate and pressure drop. According to the tested results, the twist and wavy shape fins of rectangular type show the superior performance in terms of Goodness factor and jH/f factor ratio, whereas the circular spiral fin shows the inferior values. Experimental results shows good comparison with the numerical results with a slight discrepancy of 5%, which is quite resonable.

30,000CMH급 폐열회수열교환기 겨울철 성능실험 결과 (Experiment Results of 30,000 CMH class Heat Exchangers for Wasted Heat Recovery in Winter)

  • 하병용;임홍석;김동규;금종수;정석권;정용현;김근오;명진필
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.83-86
    • /
    • 2009
  • The field of the large volume heat exchanger for wasted heat recovery ventilation system is being expanded enormously seeing as the fact that the quantity of reducing energies are huge due to the large volume heat exchanger for wasted heat recovery system at large buildings and factories, which consume large amount of energies while it has been arising huge amount of losses in Korea because of the lack of technology.

  • PDF

흡음덕트 부착 열회수형 환기장치의 음향성능 평가에 관한 연구 (A study on the acoustic performance evaluation of heat recovery ventilator with a sound absorbing duct)

  • 배명환;송준영;박희성
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.468-475
    • /
    • 2016
  • 본 연구에서는 기존 열회수형 환기장치의 음향 문제점을 파악하고, 흡음덕트 설치위치별 열회수형 환기장치의 소음저감 방안을 강구하기 위하여 관련된 국내 외 규격을 기준으로 열회수형 환기장치의 크기, 풍량 및 흡음덕트 길이를 파라미터로 한 발생소음을 측정하여 비교하고 고찰하였다. 그 결과, 무향실에서 열회수형 환기장치에 대한 소음은 흡음덕트를 설치하지 않았을 경우에 소형 및 중형 모두 풍량에 관계없이 거의 대부분 소음기준인 50 dB(A) 보다 높게 나타났고, 흡음덕트를 설치하였을 경우에는 소음도가 감소됨을 알았다. 또한, 흡음덕트의 길이에 따른 주파수 대역별 음압수준은 소형과 중형 열회수형 환기장치에서 흡음덕트의 길이가 클수록 대체적으로 감소하였고, 풍량이 클수록 대체적으로 음압수준이 증가하였다.

실증운전을 통한 배가스 열회수 히트펌프 시스템의 성능 분석 (Analysis of Performance of Heat Pump System with Flue Gas Heat Recovery through Field Test)

  • 이승호;이길봉;이영수;박상일;고창복;백영진;이관수
    • 설비공학논문집
    • /
    • 제26권1호
    • /
    • pp.1-7
    • /
    • 2014
  • A field test of a 70 kW heat pump system with flue gas heat recovery was performed by an experiment at the Korea Institute of Energy Research. The flue gas is exhausted from a 320 RT absorption chiller-heater in the heating season. Using this flue gas, source water of the heat pump is heated by a condensed-type heat exchanger in the chimney. The operating characteristics of the heat recovery heat pump system were analyzed. Based on the results of the experiments, operating maps were obtained, and an optimum operating range is suggested, in which the return and heat source water temperature are $51^{\circ}C$ and $31^{\circ}C$, respectively. Additionally, economic analysis of this system was conducted and about 50% energy cost savings can be expected in the heating season.

창호적용 배열회수 환기유닛의 열성능평가 연구 (A Study on Thermal Performance of the Heat Recovery Ventilator used Window)

  • 장철용;조수;성욱주;이진성
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.129-134
    • /
    • 2008
  • Generally the window of the building is an objective of mining and having a distant view and also for a circulation it will can open and shut because becomes the structure insulation, the meat detailed drawing it does a very difficult portion, it is. And, recently the use of heat recovery ventilator has increased rapidly for improvement of air Quality and energy saving in building. But, the high efficient heat exchange will be more increasable than water vapors which were only occurred residential active. Purpose of this study is measurement of thermal performance about heat-recovery system integrated window. The result of the window thermal resistance is 1.80 $W/m^2K$ by KS F 2278. Air tightness is 5.96 m3/m2h at 4 Pa by KS F 2292.

  • PDF