• 제목/요약/키워드: Heat of sublimation

검색결과 150건 처리시간 0.021초

곡관부를 가지는 내부 냉각유로에서 회전수 변화에 따른 열전달 및 유동 특성 (II) - 평행한 요철배열 덕트 - (Effects of Rotation Speed on Heat Transfer and Flow in a Coolant Passage with Turning Region (II) - Parallel Ribbed Duct -)

  • 김경민;김윤영;이동현;조형희
    • 대한기계학회논문집B
    • /
    • 제29권8호
    • /
    • pp.911-920
    • /
    • 2005
  • The present study investigates heat/mass transfer and flow characteristics in a ribbed rotating passage with turning region. The duct has an aspect ratio (W/H) of 0.5 and a hydraulic diameter ($D_h$) of 26.67 mm. Rib turbulators are attached in the parallel arrangement on the leading and trailing surfaces of the passage. The ribs have a rectangular cross section of 2 m (e) $\times$ 3 m (w) and an attack angle of $70^{\circ}$. The pitch-to-rib height ratio (p/e) is 7.5, and the rib height-to-hydraulic diameter ratio (e/$D_h$) is 0.075. The rotation number ranges from 0.0 to 0.20 while the Reynolds number is constant at 10,000. To verify the heat/mass transfer augmentation, internal flow structures are calculated for the same conditions using a commercial code FLUENT 6.1. The results show that a pair of vortex cells are generated due to the symmetric geometry of the rib arrangement, and heat/mass transfer is augmented up to $Sh/Sh_0=2.9$ averagely, which is higher than that of the cross-ribbed case presented in the previous study for the stationary case. With the passage rotation, the main flow in the first-pass deflects toward the trailing surface and the heat transfer is enhanced on the trailing surface. In the second-pass, the flow enlarges the vortex cell close to the leading surface, and the small vortex cell on the trailing surface side contracts to disappear as the passage rotates faster. At the highest rotation number ($R_O=0.20$), the turn-induced single vortex cell becomes identical regardless of the rib configuration so that similar local heat/mass transfer distributions are observed in the fuming region for the cross- and parallel-ribbed case.

경사제트에 따른 충돌제트/유출냉각에서 열/물질전달 특성 (Effect of Inclined Jet on Heat/Mass Transfer for Impingement/Effusion Cooling System)

  • 홍성국;이동호;조형희
    • 대한기계학회논문집B
    • /
    • 제32권4호
    • /
    • pp.283-289
    • /
    • 2008
  • An experimental investigation was conducted to investigate the heat/mass transfer for impingement/effusion cooling system with inclined jet. Jets with inclined angle of 60 are applied to impingement/effusion cooling. At the jet Reynolds number of 10,000, the experiments were carried out for blowing ratios ranging from 0.0 to 1.5. The local heat/mass transfer coefficients on the effusion plate are measured using a naphthalene sublimation method. The result indicates that the inclined jet causes the non-uniform and low heat/mass transfer compared to the vertical jet. At stagnation region, the peak position is shifted from the geometrical center of injection hole due to Coanda effect and its level is higher than that of vertical jet due to increase in turbulence intensity by steep velocity gradient near the stagnation region. Further, the secondary peak region disappears because the interaction between adjacent wall jets weakens. When the initial crossflow occurs, the distorted heat/mass transfer pattern appears. As the blowing ratio (crossflow rate) increases, the heat/mass transfer distributions become similar to those of the vertical jet. This is because the effect of crossflow is dominant compared to that of inclined jet under high blowing ratio $(M{\geq}1.0)$. At low blowing ratio $(M{\leq}0.5)$, averaged Sh value is 10% lower than that of vertical jet, whereas its value at high blowing ratio $(M{\geq}1.0)$ is similar to that of vertical jet.

가스터빈 연소실 냉각을 위한 충돌제트/유출냉각기법에서 사각핀 설치에 따른 열/물질전달 특성 (Heat/Mass Transfer Characteristics in Impingement/Effusion Cooling System with Rectangular Fins for Combustor Liner Cooling)

  • 홍성국;이동호;조형희
    • 한국유체기계학회 논문집
    • /
    • 제8권4호
    • /
    • pp.39-47
    • /
    • 2005
  • The present study has been performed to investigate the influences of rectangular fins on heat transfer in an impingement/effusion cooling system with crossflow. To simulate the impingement/effusion cooling system with initial crossflow, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of the hole diameter. The crossflow passes between the plates, and various rectangular fins are installed on the plates. Reynolds number based on the hole diameter is fixed to 10,000 and the flow rate of crossflow is changed from 0.5 to 1.5 times of that of the impinging jet. A naphthalene sublimation method is used to obtain the heat/mass transfer coefficients on the effusion plate. Also to analyze the flow characteristics, a numerical calculation is performed. When rectangular fins are installed, the flow and heat transfer pattern is changed greatly from the case without fins. In the injection hole region, the jet impinges on effusion plate without deflection and wall jet spreads symmetrically. In the effusion region, the crossflow accelerates due to the decrease of cross-sectional area in the channel. Local heat/mass transfer coefficients are enhanced significantly compared to the case without fins. As the blowing ratio increases, the effect of rectangular fins against the crossflow becomes more significant and then the higher average heat/mass transfer coefficients are obtained than the case without fins. However, the increase of blockage effect gives more pressure loss in the channel.

가스터빈 연소실 냉각을 위한 충돌제트/유출냉각기법에서 사각핀 설치에 따른 열/물질전달 특성 (Heat/Mass Transfer Characteristics in Impingement/Effusion Cooling System with Rectangular Fins for Combustor Liner Cooling)

  • 홍성국;이동호;조형희
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2004년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.289-296
    • /
    • 2004
  • The present study has been performed to investigate the influences of rectangular fins on heat transfer in an impingement/effusion cooling system with crossflow. To simulate the impingement/effusion cooling system with initial crossflow, two perforated plates are placed in parallel and staggered arrangements with a gap distance of 2 times of the hole diameter. The crossflow passes between the plates, and various rectangular fins are installed on the plates. Reynolds number based on the hole diameter is fixed to 10,000 and the flow rate of crossflow is changed from 0.5 to 1.5 times of that of the impinging jet. A naphthalene sublimation method is used to obtain the heat/mass transfer coefficients on the effusion plate. Also to analyze the flow characteristics, a numerical calculation is performed. When rectangular fins are installed, the flow and heat transfer pattern is changed greatly from case without fins. In the injection hole region, the jet impinges on effusion plate without deflection and wall jet spreads symmetrically. In the effusion region, the crossflow accelerates due to the decrease of cross-sectional area in the channel. Local heat/mass transfer coefficients are enhanced significantly compared to case without fins. As the blowing ratio increases, the effect of fins against the crossflow becomes more significant and then the higher average heat/mass transfer coefficients are obtained than the case without fins.

  • PDF

음향여기에 의한 2차원 후방계단과 공동 내의 유동 및 열전달 특성 변화 (Flow and Heat Transfer Characteristics in a Separated Flow over Backward-facing Step and Cavity Controlled by Acoustic Excitation)

  • 조형희;강승구;이동호
    • 대한기계학회논문집B
    • /
    • 제25권9호
    • /
    • pp.1253-1262
    • /
    • 2001
  • Experimental study is conducted to investigate the heat/mass transfer and flow characteristics for the flow over backward-facing step and cavities. A naphthalene sublimation method has been employed to measure the mass transfer coefficients on the duct wall and LDV system has been used to obtain mean velocity profiles and turbulence intensities. Reynolds number based on the step height and free stream velocity is 20,000 and St numbers of acoustic excitations given to separated flow are 0.2 to 0.4. The spectra of streamwise velocity fluctuation show a sharp peak forcing frequency for an acoustically excited flow. The results reveal that the vortex pairing and overall turbulence level are enhanced by the acoustic excitation and a significant decrease in the reattachment length and the increased turbulence intensity are observed with the excitation. A certain acoustic excitation increases considerably the heat/mass transfer coefficient at the reattachment point and in the recirculation region. For the cavities, heat/mass transfer is enhanced by the acoustic excitation due to the elevated turbulence intensity. For the 10H cavity, the flow pattern is significantly changed with the acoustic excitation. However, for the 5H cavity, the acoustic excitation has little effect on the flow pattern in the cavity.

경사진 평판에서의 국소물질전달 특성에 관한 실험적 연구 (An Experimental Study of Local Mass Transfer Characteristics on Inclined Flat Plate)

  • 유성연;조우식;조웅선
    • 대한기계학회논문집B
    • /
    • 제35권12호
    • /
    • pp.1335-1341
    • /
    • 2011
  • 본 연구의 목적은 평행 평판과 경사진 평판의 물질전달 특성을 비교하여 경사각에 따른 유동의 박리와 재부착이 물질전달에 미치는 영향을 규명하는 것이다. 나프탈렌승화법을 사용하여 평판에서의 국소물질전달계수를 측정하였으며, 평판의 경사각은 $10^{\circ}$에서 $-10^{\circ}$까지 $5^{\circ}$간격으로 변화시키고 유동 속도는 2m/s에서 15m/s까지 변화시켰다. 양의 각으로 경사진 평판에서 국소 Sherwood 수는 경계층이 발달하면서 감소하는 경향을 보이고 있는며, 음의 각으로 경사진 평판의 경우는 재순환 와류의 박리점에서 최소값을 나타내고, 박리된 유동의 재부착점에서 최대값을 나타내었다. 평균 Sherwood 수는 음의 각과 양의 각 모두 평행 평판보다 낮았다.

분산염료 염색공정이 PET직물의 UV경화형 방염가공에 미치는 영향 (Effect of Disperse Dyeing on UV-curable Flame-retardant Finish of PET Fabrics)

  • 정용균;장진호
    • 한국염색가공학회지
    • /
    • 제20권2호
    • /
    • pp.66-74
    • /
    • 2008
  • Effect of disperse dyeing on flame retardant finishing of PET fabrics via UV curing using three UV curable phosphorous-containing methacrylates and ammonium polyphosphate(APP) was investigated. The dye fixation and flame retardancy of PET fabrics did not change significantly with excellent durability to five laundering cycles irrespective of the dyeing and finishing sequence. However, the flame retardancy of Pekoflam-treated fabrics was lower than that of the UV treated and decreased substantially when heat treatment was carried out before the dyeing. The dyeability of the flame-retardant PET fabrics was not affected in the case of UV curing of the methacrylates alone. However, UV finishing after the dyeing caused significant decrease in K/S and ${\Delta}E$ due to changed refraction and inherent color of surface coating of the UV curable monomers and APP. Whereas the heat treatment with Pekoflam decreased both color fastness to laundering and sublimation, surprisingly the UV finish of PET fabrics before and after the dyeing increased the color fastness probably resulting from the presence of photopolymerized surface layer on the fabrics.

PET 직물용 심색성 분산염료의 합성과 Black 염색 (Synthesis and Application of Color Depth Black Disperse Dyes for PET Fabric)

  • 김혜진;김재호;김동욱;홍승표;김상진;김희동;김현아;허만우
    • 한국염색가공학회지
    • /
    • 제26권4호
    • /
    • pp.290-296
    • /
    • 2014
  • In order to produce black disperse dye which has high heat resistance and depth color for polyester(PET), an orange disperse dye was designed and synthesized with pyridine based derivatives to get high heat resistance. Disperse blue dye adopts heterocycles structure for high molar extinction coefficient and long wavelength absorption. Synthesized disperse dye is micronized to an particle size of $0.7{\mu}m$. The mixing condition for black color using commercial disperse violet 93 is blue dye 30%, red dye 21%, and orange dye 21%, respectively. Dyed PET fabric with synthesized dye has quiet good color fastness to sublimation(grade 3-4) and has excellent rubbing, washing and light fastness grade 4-5.

석조문화재 해체에 따른 표면 손상부분 보강방안 연구 - 승화성(가역성) 강화처리제 적용실험을 중심으로 - (A Study on the Reinforcement of the Damaged Stone Surface by Dismantling of Stone Cultural Heritages - Focusing on the Experiment of a Sublimation(Reversibility) type Consolidant -)

  • 이태종;오정현;조하진;김사덕
    • 보존과학회지
    • /
    • 제31권4호
    • /
    • pp.351-360
    • /
    • 2015
  • 본 논문은 석조문화재 해체과정에서 발생할 수 있는 표면 손상부분 보강방안 마련을 위해 승화성 강화처리제인 시클로도데칸을 사용한 임시 강화처리제를 연구한 결과이다. 기존 발포성 우레탄 폼을 사용한 보강방법의 단점을 보완하기 위해 시클로도데칸을 용제에 희석하여 표면 및 박리 내부를 보강하여 부재를 해체한 후 $60^{\circ}C$ 내외의 열을 가해 승화시키는 처리방법에 관한 것이다. 이와 같은 방법은 시클로도데칸이 전량 승화되는 뛰어난 가역성과 손상된 표면의 보강과 강화에 필요한 강도를 담보할 수 있다는 장점이 있으나, 용제에 따라 효과가 다를 수 있으므로 본 연구에서는 석유에테르에 희석하는 방법 또는 중탕하여 적용하는 방법에 대한 연구를 진행하였다. 실험결과 현장에서의 작업여건을 고려하여 박리부분 주입 및 충전은 석유에테르 중탕 방법, 표면 도포는 석유에테르에 희석한 시클로도데칸으로 임시 강화처리하는 것이 가장 적합할 것으로 확인되었다.

플레이트 휜 코일형 증발기의 착상에 관한 기초 실험 (Basic Experiment on Frost of Plate Fin Coil Evaporator)

  • 백승문;김창영;한인근;김재돌;윤정인
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1999년도 추계 학술발표회 논문집
    • /
    • pp.211-216
    • /
    • 1999
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. In this report, a prediction taking into account the change of the fin efficiency due to the growth of the frost layer.

  • PDF