화염으로부터의 복사 열유속의 계측 I (A study on the measurement of Radiative Heat flux form the flame(I) -Design and Calibration of a Heat flux meter-)

  • 정종수;인종수;김승수
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.484-491
    • /
    • 1990
  • A heat-flux meter has been designed and manufactured to measure the heat flux from the flame. A calibration method of the heat-flux meter by a calibration furnace has also been proposed. The k-type (Chromel-Alumel) thermocouple material has been used as the material for the beat-flux meter. The electormotive force (e.m.f.) from the K-type thermocouple is shown to be linearly proportional to the heat flux absorbed. The characteristics of the heat-flux meter become better as the radius of heat absorbing disk becomes larger and its thickness thinner.

서울지역의 수도계량기 동파방지방안 연구 (A Study on Frost Protection Methods for Water Meter in Seoul Area)

  • 김효일;유통희;박태준;오수영;최영준
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.612-617
    • /
    • 2007
  • Water meter frost in winter is a nuisance to the water administration and citizen as well. It causes stop of water supply, possibility of accident due to leakage freezing, and additional official work to change frost water meters. This study was carried out to give some basic information of water meter frost condition, to verify the effect of frost protection devices such as lagging vinyl cover, electric heater, and meter pit using subterranean heat. Nearly half of the number of the water meter frost happens in old apartment house with outer corridor, and temperature of the meter box was measured in that kind of apartment house, comparing with atmosphere temperature. The capability of three kinds of lagging vinyl cover was investigated by measuring the inside temperature of the insulated box. Also the capability of existing meter pits and new meter pits using subterranean heat was compared by measuring the inside temperature of the pits. One of the result is that the inside temperature of meter pits using subterranean heat was higher than that of the existing ones, and deeper pit causes higher inside temperature in case of using subterranean heat.

  • PDF

열전달 질량유량계 개발 (Development of Thermal Mass Flow Meter)

  • 지대성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.118-122
    • /
    • 1999
  • Thermal mass flow meter was developed using principle of convective heat transfer. The advantage of thermal mass flow meter is measuring mass flow directly, therefore, it is not required to use densitometer or temperature/pressure and DP gages. The final accuracy of this thermal mass flow meter is $\pm1.0{\%}$ or better, reproducibility is $\pm0.2{\%}$, and the response time is 600 ms. The thermal mass flow meter was developed from a single point to multi-points (maximum is 9 points), and the number of points is determined according to desired accuracy and size of piping/duct. Since this thermal mass flow meter adopted microprocessor based design, it is intrinsically accurate, self-error detectable, and has self-diagnosis function. The applications of this thermal mass flow meter are for measurement and control of HVAC air flow, other gas flow, and liquid flow.

  • PDF

HFM, LFA와 TCi를 이용한 건축 재료의 열전도율 측정과 상관관계 분석 (Building Materials Thermal Conductivity Measurement and Correlation with Heat Flow Meter, Laser Flash Analysis and C-Therm TCi)

  • 차정훈;서정기;김수민
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.92-97
    • /
    • 2011
  • Nowdays the most critical problem is global warming and the most important reason is the high emition of carbondioxide. 23% of the use of carbondioxide is used in building and decreasing the use of it is very important. One of the biggest factor that can decrease the use of energy is developing the heat conducting ratio of the materials we use in building. Heat conducting ratio is the important factor in the use of reducing energy comsumation. In this research, there are methods about how to measure the heat conducting ratio, and the existing the representing measuring method which is Heat Flow Meter HFM 436, Laser Flash Analysis and find out about the TCi of the new method C-Therm and compare the results.

  • PDF

금속스크랩이 혼합된 상변화물질의 유효열전도율 (Effective thermal conductivity of the phase change material with metal scrap)

  • 김시범;노승탁
    • 대한기계학회논문집
    • /
    • 제10권6호
    • /
    • pp.923-928
    • /
    • 1986
  • 본 논문에서는 열전도율이 큰 금속의 스크랩과 파라핀을 혼합한 축열 매질에 있어서 스크랩의 체적 혼합율에 따르는 열전도율의 변화를 모델링과 실험으로 구해서 축열 계산에 필요한 열전도율 자료를 제시하고자 한다.

Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube

  • Hong Hiki;Kang Chaedong;Peck Jong Hyeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제12권4호
    • /
    • pp.206-213
    • /
    • 2004
  • Cycle test for developed phase change material (PCM) is necessary in order to assess the variation of latent heat, which decreases with time by deterioration. T-history method and measurement using heat-flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different to the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtained rea-sonable values for heat of fusion.

밀폐튜브 내 저온 PCM의 잠열측정법 (Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube)

  • 류경용;박창현;백종현;홍회기
    • 설비공학논문집
    • /
    • 제15권7호
    • /
    • pp.604-610
    • /
    • 2003
  • Cycle test for developed phase change material (PCM) is necessary in order to analyze the variation of latent heat, which decreases with time by deterioration. 7-history method and measurement using heat flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring the heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different from the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtain reason-able values for heat of fusion by both methods.

목질마루바닥재와 벽체용 재료를 이용한 평판열류계법과 MTPS (Modified Transient Plane Source)법의 열전도율 상관관계 분석 (Correlation Analysis of the Thermal Conductivity Heat Flow Meter and MTPS (Modified Transient Plane Source) Method Using Wood Flooring and Wall Materials)

  • 차정훈;서정기;김수민
    • 한국가구학회지
    • /
    • 제22권2호
    • /
    • pp.118-125
    • /
    • 2011
  • These days global warming is the most important problem and the most important factor is high emission of carbon dioxide. The 23% of carbon dioxide emission for building construction must be reduced. Thermal conductivity is the most basic factor that can decrease the energy consumption especially insulation. Therefore, an accurate and continuous thermal conductivity measurement can be a way to save energy. In this paper, there are methods about how to investigate thermal conductivity measurements and comparing two methods which are the Heat Flow Meter 436 and TCi.

  • PDF

이산화탄소가 수소 산소부화 화염의 열전달에 미치는 영향 (Effects of CO2 on Heat Transfer from Oxygen-Enriched Hydrogen Flame)

  • 이창엽;최준원;백승욱
    • 대한기계학회논문집B
    • /
    • 제28권8호
    • /
    • pp.937-944
    • /
    • 2004
  • An experimental study has been conducted to evaluate the effects of $CO_2$ on heat transfer from oxygen-enriched hydrogen flame. Experiments were performed on flames stabilized by a co-flow swirl burner, which was mounted on top of the furnace. Five different oxidizer compositions were prepared by replacing $N_2$ with $CO_2$. In a steady state, the total as well as radiative heat flux from the flame to the wall of furnace have been measured using a heat flux meter. Temperature distribution in furnace also has been measured and compared. By increasing $CO_2$ proportion in the oxidizer, the convection played a more significant role rather than radiation. Overall temperature in the furnace was seen to be decreased, while the total heat flux has increased.

중앙집중난방방식 공동주택의 난방열량 계량 및 요금부과방안 연구 (A Study on the Metering and the Rating Methods of Heat in Apartment Houses with Centralized Heating System)

  • 이태원;김용기
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.27-32
    • /
    • 2009
  • The measuring apparatus such as heat meter is legally obliged to be installed and used for heat rating with heat or flow rate in residential buildings in Korea. There are two kinds of apparatus to measure heat consumed at each households, i.e., heat meter and hot water flowmeter. Contrast to the most of buildings with hot water flowmeter well being used for rating, heat meters have been used only 42.6% in the buildings with central heating system. But there is a critical problem in the course of using hot water flowmeter for heat rating, yielding distorted and unfair result which is different from the real value of heat supplied. Experiments with several parameters were carried out in this study to analyze this phenomenon quantively and alternative methods were proposed for rational heat rating.