• Title/Summary/Keyword: Heat meter

Search Result 202, Processing Time 0.025 seconds

A study on the measurement of Radiative Heat flux form the flame(I) -Design and Calibration of a Heat flux meter- (화염으로부터의 복사 열유속의 계측 I)

  • 정종수;인종수;김승수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.2
    • /
    • pp.484-491
    • /
    • 1990
  • A heat-flux meter has been designed and manufactured to measure the heat flux from the flame. A calibration method of the heat-flux meter by a calibration furnace has also been proposed. The k-type (Chromel-Alumel) thermocouple material has been used as the material for the beat-flux meter. The electormotive force (e.m.f.) from the K-type thermocouple is shown to be linearly proportional to the heat flux absorbed. The characteristics of the heat-flux meter become better as the radius of heat absorbing disk becomes larger and its thickness thinner.

A Study on Frost Protection Methods for Water Meter in Seoul Area (서울지역의 수도계량기 동파방지방안 연구)

  • Kim, H.I.;Ryu, T.H.;Park, T.J.;Oh, S.Y.;Choi, Y.J.
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.612-617
    • /
    • 2007
  • Water meter frost in winter is a nuisance to the water administration and citizen as well. It causes stop of water supply, possibility of accident due to leakage freezing, and additional official work to change frost water meters. This study was carried out to give some basic information of water meter frost condition, to verify the effect of frost protection devices such as lagging vinyl cover, electric heater, and meter pit using subterranean heat. Nearly half of the number of the water meter frost happens in old apartment house with outer corridor, and temperature of the meter box was measured in that kind of apartment house, comparing with atmosphere temperature. The capability of three kinds of lagging vinyl cover was investigated by measuring the inside temperature of the insulated box. Also the capability of existing meter pits and new meter pits using subterranean heat was compared by measuring the inside temperature of the pits. One of the result is that the inside temperature of meter pits using subterranean heat was higher than that of the existing ones, and deeper pit causes higher inside temperature in case of using subterranean heat.

  • PDF

Development of Thermal Mass Flow Meter (열전달 질량유량계 개발)

  • Chi, Daesung
    • 유체기계공업학회:학술대회논문집
    • /
    • 1999.12a
    • /
    • pp.118-122
    • /
    • 1999
  • Thermal mass flow meter was developed using principle of convective heat transfer. The advantage of thermal mass flow meter is measuring mass flow directly, therefore, it is not required to use densitometer or temperature/pressure and DP gages. The final accuracy of this thermal mass flow meter is $\pm1.0{\%}$ or better, reproducibility is $\pm0.2{\%}$, and the response time is 600 ms. The thermal mass flow meter was developed from a single point to multi-points (maximum is 9 points), and the number of points is determined according to desired accuracy and size of piping/duct. Since this thermal mass flow meter adopted microprocessor based design, it is intrinsically accurate, self-error detectable, and has self-diagnosis function. The applications of this thermal mass flow meter are for measurement and control of HVAC air flow, other gas flow, and liquid flow.

  • PDF

Building Materials Thermal Conductivity Measurement and Correlation with Heat Flow Meter, Laser Flash Analysis and C-Therm TCi (HFM, LFA와 TCi를 이용한 건축 재료의 열전도율 측정과 상관관계 분석)

  • Cha, Jung-Hoon;Seo, Jung-Ki;Su-Min, Kim
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.92-97
    • /
    • 2011
  • Nowdays the most critical problem is global warming and the most important reason is the high emition of carbondioxide. 23% of the use of carbondioxide is used in building and decreasing the use of it is very important. One of the biggest factor that can decrease the use of energy is developing the heat conducting ratio of the materials we use in building. Heat conducting ratio is the important factor in the use of reducing energy comsumation. In this research, there are methods about how to measure the heat conducting ratio, and the existing the representing measuring method which is Heat Flow Meter HFM 436, Laser Flash Analysis and find out about the TCi of the new method C-Therm and compare the results.

  • PDF

Effective thermal conductivity of the phase change material with metal scrap (금속스크랩이 혼합된 상변화물질의 유효열전도율)

  • 김시범;노승탁
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.923-928
    • /
    • 1986
  • A set of measurements has been made for the thermal conductivity of the pure paraffin in liquid and solid phases and for the effective thermal conductivity of the paraffin with metal scrap with the aid of the heat flux meter. Ther thermopile-type heat flux meter has been designed by steady state method and the functional relation between the temperature difference of both sides and heat flux has been obtained. The measured values of thermal conductivity are compared with the existing data for the pure paraffin and with the predicated values from the suggested model in which only one empirical constant is contained. The comparison within ten percent of the volume fraction of the metal scrap in the paraffin is satisfactory.

Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube

  • Hong Hiki;Kang Chaedong;Peck Jong Hyeon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.4
    • /
    • pp.206-213
    • /
    • 2004
  • Cycle test for developed phase change material (PCM) is necessary in order to assess the variation of latent heat, which decreases with time by deterioration. T-history method and measurement using heat-flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different to the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtained rea-sonable values for heat of fusion.

Measurement Methods of Latent Heat for PCM with Low Melting Temperature in Closed Tube (밀폐튜브 내 저온 PCM의 잠열측정법)

  • 류경용;박창현;백종현;홍회기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.7
    • /
    • pp.604-610
    • /
    • 2003
  • Cycle test for developed phase change material (PCM) is necessary in order to analyze the variation of latent heat, which decreases with time by deterioration. 7-history method and measurement using heat flux meter are appropriate for the cycle test in a tube filled with PCM because they do not need an extraction of sample in measuring the heat of fusion. In the present study, these methods were applied to a PCM having a melting point below a room temperature, different from the past studies for PCMs melting above a room temperature. As a result of experiment using pure water as specimen, we can obtain reason-able values for heat of fusion by both methods.

Correlation Analysis of the Thermal Conductivity Heat Flow Meter and MTPS (Modified Transient Plane Source) Method Using Wood Flooring and Wall Materials (목질마루바닥재와 벽체용 재료를 이용한 평판열류계법과 MTPS (Modified Transient Plane Source)법의 열전도율 상관관계 분석)

  • Cha, Jung-Hoon;Seo, Jung-Ki;Kim, Su-Min
    • Journal of the Korea Furniture Society
    • /
    • v.22 no.2
    • /
    • pp.118-125
    • /
    • 2011
  • These days global warming is the most important problem and the most important factor is high emission of carbon dioxide. The 23% of carbon dioxide emission for building construction must be reduced. Thermal conductivity is the most basic factor that can decrease the energy consumption especially insulation. Therefore, an accurate and continuous thermal conductivity measurement can be a way to save energy. In this paper, there are methods about how to investigate thermal conductivity measurements and comparing two methods which are the Heat Flow Meter 436 and TCi.

  • PDF

Effects of CO2 on Heat Transfer from Oxygen-Enriched Hydrogen Flame (이산화탄소가 수소 산소부화 화염의 열전달에 미치는 영향)

  • Lee, Chang-Yeop;Choi, Joon-Won;Baek, Seung-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.8 s.227
    • /
    • pp.937-944
    • /
    • 2004
  • An experimental study has been conducted to evaluate the effects of $CO_2$ on heat transfer from oxygen-enriched hydrogen flame. Experiments were performed on flames stabilized by a co-flow swirl burner, which was mounted on top of the furnace. Five different oxidizer compositions were prepared by replacing $N_2$ with $CO_2$. In a steady state, the total as well as radiative heat flux from the flame to the wall of furnace have been measured using a heat flux meter. Temperature distribution in furnace also has been measured and compared. By increasing $CO_2$ proportion in the oxidizer, the convection played a more significant role rather than radiation. Overall temperature in the furnace was seen to be decreased, while the total heat flux has increased.

A Study on the Metering and the Rating Methods of Heat in Apartment Houses with Centralized Heating System (중앙집중난방방식 공동주택의 난방열량 계량 및 요금부과방안 연구)

  • Lee, Tae-Won;Kim, Yong-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.27-32
    • /
    • 2009
  • The measuring apparatus such as heat meter is legally obliged to be installed and used for heat rating with heat or flow rate in residential buildings in Korea. There are two kinds of apparatus to measure heat consumed at each households, i.e., heat meter and hot water flowmeter. Contrast to the most of buildings with hot water flowmeter well being used for rating, heat meters have been used only 42.6% in the buildings with central heating system. But there is a critical problem in the course of using hot water flowmeter for heat rating, yielding distorted and unfair result which is different from the real value of heat supplied. Experiments with several parameters were carried out in this study to analyze this phenomenon quantively and alternative methods were proposed for rational heat rating.

  • PDF