지열을 이용한 외기부하저감시스템의 냉각 및 가열효과 예측을 위한 간이추정법에 관한 연구 (A Study on the Simplified Presumption Method for the Prediction of Cooling and Heating Performance in a Fresh Air Load Reduction System by Using Geothermal Energy)

  • 손원득;박경순
    • 설비공학논문집
    • /
    • 제22권9호
    • /
    • pp.628-634
    • /
    • 2010
  • This paper presents a feasibility study of a fresh air load reduction system by using an underground double floor space. The fresh air is introduced into the double slab space and passes through the opening bored into the footing beam. The air is cooled by the heat exchange with the inside surface of the double slab space in summer, and heated in winter. This system not only reduces sensible heat load of the fresh air by heat exchange with earth but also reduces latent heat load of the fresh air by ad/de-sorption of underground double slab concrete. In this paper, we proposed a simplified presumption method for the prediction of cooling and heating performance in the system. In conclusion the proposed method has been verified by comparing with the calculated value of the numerical analysis model by using nonlinear two-dimension hygroscopic question.

Study on Energy Saving Properties by using City- Water as a Heat Source for Dwellings

  • Chung, Yong-Hyun;Mizuno, Minoro;Simoda, Yoshiyuki;Kum, Jong-Soo;Choi, Kwang-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제6권
    • /
    • pp.168-176
    • /
    • 1998
  • A simulation study was conducted to use city-water which is thermally regulated by unused energy as a heat source for urban dwellings. This study utilized multiple heat pump system using the city-water as a heat source and suggested a method of reducing the heat load of hot water supply. The simulation was done to calculate the energy savings at a dwelling for a year. The relation between the controlled temperature of city-water. and electric energy in all seasons was also investigated. Furthermore, it has been found that the controlled water system can lead to considerable energy savings and decrease environmental load such as sensible waste heat which otherwise would form heat islands.

  • PDF

HTS변압기에서 액체질소 표면 상부의 열전달 해석 (Heat Transfer Analysis above L$N_2$ Surface in HTS Transformer)

  • 최연석;장호명
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 학술대회 논문집
    • /
    • pp.174-177
    • /
    • 2003
  • Cooling load from the top plate to L$N_2$ surface, including wall conduction, gas conduction, radiation, and current leads, is investigated in a closed cooling system for HTS transformer. In general methods of load calculation, individual load is estimated separately, but they are actually coupled each other because of natural convection of nitrogen vapor. Using heat transfer analysis, we calculate cooling load with taking into account the effect of natural convection. Cooling load is under- estimated approximately 2 % when the natural convection is ignored. If the operating current is high, there will be a wide difference between actual cooling load and cooling load by individual calculation. Cooling load decreases with increasing number of radiation shield. With production, construction, and cooling load, three radiation shields are proper to 1 MVA HTS transformer.

  • PDF

니켈-티타늄 와이어의 열처리에 따른 부하-변위 특성 변화 (Effects of heat treatment on the load-deflection properties of nickel-titanium wire)

  • 장수호;김광원;임성훈
    • 대한치과교정학회지
    • /
    • 제36권5호
    • /
    • pp.349-359
    • /
    • 2006
  • 니켈-티타늄 합금은 높은 spring-back성질, 초탄성 효과, 형상기억 효과 등의 장점을 가지고 있으나 성형이 어렵다는 단점을 가지고 있다. 본 연구에서는 니켈-티타늄 와이어의 굴곡을 위한 열처리 시에 나타나는 부하-변위 곡선의 변화 및 상전이 온도 변화와 같은 물성 변화 양상을 조사하고자 하였다. 수종의 니켈-티타늄 와이어를 열처리를 시행하지 않은 군, 전기저항 열처리 장치를 이용하여 와이어 단면적에 따라 제조회사에서 권장하는 전류를 기초로 하여 $00.016"\;{\times}\;00.022"$ (5 A, 7 sec), $0.018"\;{\times}\;0.025"$ (6 A, 7 sec) 그리고 $0.0215"\;{\times}\;0.028"$ (7 A, 8 sec) 와이어를 열처리만 시행한 실험군, 열처리를 시행하여 굴곡을 부여한 실험군 그리고 열처리 시간을 1초 증가시켜 굴곡을 부여한 실험군으로 분류하여 3점 굴곡 실험과 시차주사열량측정을 하여 다음과 같은 결과를 얻었다. $0.016"\;{\times}\;0.022"$, $0.018"\;{\times}\;0.025"$ 그리고 $0.0215"\;{\times}\;0.028"$ 니켈-티타늄 와이어에서 굴곡을 부여하지 않고 열처리만 시행한 실험군이 열처리를 시행하지 않은 대조군에 비해 부하-변위 곡선이 상방 이동되어 초탄성 현상에 의한 평탄역(loading and unloading plateau)의 힘이 더 증가되었다. $0.016"\;{\times}\;0.022"$, $0.018"\;{\times}\;0.025"$ 그리고 $0.0215"\;{\times}\;0.028"$ 와이어에서 열처리만 시행한 실험군이 열처리를 시행하지 않은 군보다 더 낮은 austenite finish ($A_f$) 온도를 보였다. $0.018"\;{\times}\;0.025"$$0.0215"0.028"$ 와이어에서 열처리를 시행하여 굴곡을 부여한 실험군은 열처리만 시행한 실험군과 열처리를 시행하지 않은 대조군에 비해 부하-변위 곡선이 상방 이동되었으며, 열처리 시간을 1초 증가시켜 굴곡을 부여한 실험군에서 가장 높은 부하-변위 곡선을 나타냈다. $0.018"\;{\times}\;0.025"$ 그리고 $0.0215"\;{\times}\;0.028"$ 와이어에서 $A_f$ 온도는 열처리 시간을 1초 증가시켜 굴곡을 부여한 실험군에서 가장 낮게 관찰되었고 열처리를 시행하여 굴곡을 부여한 실험군, 열처리만 시행한 실험군 그리고 열처리를 시행하지 않은 대조군 순으로 높게 관찰되었다. 이상의 결과를 종합할 때, 임상에서 니켈-티타늄 합금 와이어에 굴곡을 부여하기 위해 열처리하는 경우 초탄성 특성은 유지될 수 있으나, 부하-변위 곡선의 상방 증가가 나타나므로, 와이어에 의한 교정력이 증가될 수 있음에 유의하여야 한다.

멀티버너 보일러용 열교환기 모듈 특성 시험 - 부하별 특성 결과 - (Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler - Part Load Test Results -)

  • 김종진;최규성;기호충;강새별
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1025-1030
    • /
    • 2008
  • We develop heat exchanger modules for a multi-burner boiler. The heat exchanger module is kind of a heat recovery steam generator (HRSG). This heat recovery system has 4 heat exchanger modules. The 1st module consists of 27 bare tubes due to high temperature exhaust gas and the others consist of 27 finned tubes. The maximum steam pressure of each module is 10 bar and tested steam pressure is 4 bar. In order to test these heat exchanger modules, we make a 0.5t/h flue tube boiler (LNG, $40\;Nm^3/h$). The test results of 100% boiler load show that heat transfer rate of 1st module is 49.7 Mcal/h which is 34% of total heat transfer rate and that of 2nd module is 82.6 Mcal/h which is 57% of total heat transfer rate. The reason of higher the heat transfer rate of 2nd module than that of 1st module is that the 2nd heat exchanger module has finned tubes instead of bare tube. The boiler load 50% results show that only 2 heat exchanger modules are needed to extract the heat from the flue gas to water. From this result, it is very important of optimum design of the first finned tube among all water tubes.

  • PDF

지열원 멀티 열펌프 시스템의 시설원예 적용 난방성능 특성 실증 연구 (Heating Performance of a Ground Source Multi-Heat Pump for a Greenhouse)

  • 강신형;최종민;문제명;권형진
    • 설비공학논문집
    • /
    • 제22권6호
    • /
    • pp.337-344
    • /
    • 2010
  • Good plant-growth conditions can be achieved by means of using greenhouses. One of the main issues in greenhouse cultivation is energy savings through the development of high efficient heating and cooling system. GSHPs are one of the recommended systems to cope with this pending need. The aim of this study is to investigate the heating performance of ground source multi-heat pump system installed in a greenhouse under part load conditions. Daily average heating COP of the heat pump unit was very high by at least 7.4, because of relatively large condenser, evaporator, and mass flow rate through ground loop heat exchanger. However, the system COP, overall heating coefficient of the performance of the system with heat pump unit and GLHX, decreased drastically due to relatively large power consumption of circulating pump under part load condition. It is suggested that the technology to enhance the performance of the ground source multi-heat pump system for a greenhouse under part load conditions should be developed.

축열식 지열원 히트펌프 시스템의 냉방기간 실증운전 결과 및 운영비용 분석 (Empirical Results and Operational Cost Analysis of Geothermal Heat Pump System using Thermal Energy Storage in Cooling Season)

  • 김득원;이동원;허재혁;김민휘
    • 설비공학논문집
    • /
    • 제30권4호
    • /
    • pp.167-174
    • /
    • 2018
  • The geothermal heat pump systems were installed for heating and cooling of public buildings in Jincheon Eco-friendly Energy town. The heat pump system was operated at night to save on operational costs, and the cold heat was stored in thermal energy storage (TES). In this study, the performance of geothermal heat pump systems with the TES during the summer season was analyzed, and the operational costs with and without the TES were compared. The electric chiller model was used to simulate a heat pump applied without the TES system. Electric rates of each system were measured to calculate operational costs. When the TES is used in the air conditioning system, the electric load (30.4 MWh) calculated in the daytime can move to off-peak load time, and the operational cost is reduced by 36~54%.

Low-grade waste heat recovery and repurposing to reduce the load on cooling towers

  • McLean, Shannon H.;Chenier, Jeff;Muinonen, Sari;Laamanen, Corey A.;Scott, John A.
    • Advances in Energy Research
    • /
    • 제7권2호
    • /
    • pp.147-166
    • /
    • 2020
  • Industrial cooling towers are often ageing infrastructure that is expensive to maintain and operate. A novel approach is introduced in which a heat pump circuit is incorporated to reduce the load upon the towers by extracting low-grade energy from the stream sent to the towers and repurposing in on-site processing operations. To demonstrate the concept, a model was constructed, which uses industrial data on cooling towers linked to a smelter's sulphuric acid plant, to allow direct economic and environmental impact comparison between different heat recovery and repurposing scenarios. The model's results showed that implementing a heat pump system would significantly decrease annual operating costs and achieve a payback period of 3 years. In addition, overall CO2 emissions could be reduced by 42% (430,000 kg/year) and a 5% heat load reduction on the cooling towers achieved. The concept is significant as the outcomes introduce a new way for energy intensive industrial sectors, such as mineral processing, to reduce energy consumption and improve long-term sustainable performance.

COMBUSTION STABILITY OF DIESEL-FUELED HCCI

  • Shi, L.;Deng, K.;Cui, Y.
    • International Journal of Automotive Technology
    • /
    • 제8권4호
    • /
    • pp.395-402
    • /
    • 2007
  • Homogeneous Charge Compression Ignition (HCCI) shows great potential for low $NO_x$ emission but is hampered by the problem of no direct method to control the combustion process. Therefore, HCCI combustion becomes unstable easily, especially at lower and higher engine load. This paper presents a method to achieve diesel-fueled HCCI combustion, which involves directly injecting diesel fuel into the cylinder before the piston arrives at top dead center in the exhaust stroke and adjusting the valve overlap duration to trap more high temperature residual gas in the cylinder. The combustion stability of diesel-fueled HCCI combustion and the effects of engine load, speed, and valve overlap on it are the main points of investigation. The results show that: diesel-fueled HCCI combustion has two-stage heat release rate (low temperature and high temperature heat release) and very low $NO_x$ emission, combustion stability of the HCCI engine is worse at lower load because of misfire and at higher load because of knock, the increase in engine speed aids combustion stability at lower load because the heat loss is reduced, and increasing negative valve overlap can increase in-cylinder temperature which aids combustion stability at lower load but harms it at higher load.

근사적 열발생율에 의한 예연소실식 디젤기관의 연소해석 (Combustion Analysis in a Pro-Combustion Chamber Diesel Engine by Approximate Heat Release Rate)

  • 왕우경
    • 수산해양기술연구
    • /
    • 제29권1호
    • /
    • pp.30-38
    • /
    • 1993
  • 예연소실식 디젤기관에 있어서 박용부하운전조건에 따른 연소특성을 규명하기 위해 예언소실의 압력데이터를 single-zone, single-chamber의 열역학적 해석에 적용하여 연소해석을 행한 결과 다음과 같은 결론을 얻었다. 1) 부하가 증가함에 따라 최고압력이 상승하고 그 위치가 크랭크각도상 후진되었다. 2) 착화 지연시간은 부하에 관계없이 거의 일정하고, 부하가 증가할수록 가연 혼합기 형성에 소요되는 흡열량은 겉보기로 감소하였다. 3) 예혼합 연소단계의 열발생 양상은 부하에 관계없이 거의 비슷하고, 예혼합 연소시간은 부하가 증가할수록 짧아졌다. 4) 부하가 증가함에 따라 예혼합 연소량은 다소 증가하나 일정 연공비 이상에서는 거의 일정했다. 5) 예혼합 연소분율은 부하가 증가함에 따라 감소했다.(이 논문의 결론부분임)

  • PDF