• 제목/요약/키워드: Heat insulation plate

검색결과 47건 처리시간 0.025초

Effects of SiC Particle Size and Inorganic Binder on Heat Insulation of Fumed Silica-based Heat Insulation Plates

  • Jo, Hye Youn;Oh, Su Jung;Kim, Mi Na;Lim, Hyung Mi;Lee, Seung-Ho
    • 한국세라믹학회지
    • /
    • 제53권4호
    • /
    • pp.386-392
    • /
    • 2016
  • Heat insulation plates of fumed silica were prepared by mixing fumed silica, SiC powder and chopped glass fiber by a high speed mixer followed by pressing of the mixture powder in a stainless steel mold of $100{\times}100mm$. Composition of the plates, particle size of SiC, and type of inorganic binder were varied for observation of their contribution to heat insulation of the plate. The plate was installed on the upper portion of an electric furnace the inside temperature of which was maintained at $400^{\circ}C$ and $600^{\circ}C$, for investigation of heat transfer through the plate from inside of the electric furnace to outside atmosphere. Surface temperatures were measured in real time using a thermographic camera. The particle size of SiC was varied in the range of $1.3{\sim}17.5{\mu}m$ and the insulation was found to be most excellent when SiC of $2.2{\mu}m$ was incorporated. When the size of SiC was smaller or larger than $2.2{\mu}m$, the heat insulation effect was decreased. Inorganic binders of alkali silicate and phosphate were tested and the phosphate was found to maintain the heat insulation property while increasing mechanical properties.

원전 금속단열재의 구조 건전성 강화를 위한 설계 방안 (Design for Strengthening Structural Integrity of the Reflective Metal Insulation in the Nuclear Power Plant)

  • 이성명;어민훈;김승현;장계환
    • 한국안전학회지
    • /
    • 제30권3호
    • /
    • pp.107-113
    • /
    • 2015
  • The goal of this paper is to investigate structural integrity factors of RMI(reflective metal insulation) to confirm the design requirements in nuclear power plant. Currently, a glass wool insulation is using now, but it will gradually be replaced with the reflective metal insulation maded by stainless steel plates. The main function of an insulation is to minimize a heat loss of vessel and pipes in RCS(reactor coolant system). It has to maintain structural a integrity in nuclear power plant life duration. In this study, the structural integrity analysis was carried out both multi-plate and outer shell plate by using a static analysis and experimental test. First, inner multi-plate has a self support structure for being air space. Because the effect of total static weight in multi-layer plate is low, a plate collapse possibility is not high. Considering optimum thin plate pressing process, it has to pre-check the basic physical properties. Second, the outer segment thickness and stiffener shape are verified by the numerical static analysis, and sample test for both type of panel and cylindrical pipe model.

금속단열재 박판의 설계인자별 단열성능 영향 연구 (Studies on Insulation Effect Related with Thin-Plate Design Factors for Reflective Metal Insulation(RMI) of Nuclear Power Plant)

  • 어민훈;이성명;장계환
    • 설비공학논문집
    • /
    • 제28권9호
    • /
    • pp.350-354
    • /
    • 2016
  • Although fibrous insulations are generally used with resistive insulation type, metallic insulation is proper matter to satisfy low head-loss and equipment life when considering the specific condition, especially for Nuclear power plant. Common insulation is resistance insulation with a low thermal conductivity. but RMI is made of sheet plate with low emissivity and closed air space. Thermal radiation is blocked by stainless steel with low emissivity. Thermal conductivity and thermal convection are blocked by closed air space. This study shows the changes and effects of the heat loss according to shape and method of stacking sheet plates inserted into the insulation and analyzed the most optimized way for thermal insulation performance. The result shows that using sheet plate structure through raised and protruding shape processing was the appropriate model to optimize thermal performance. Additionally, insulating performance of RMI improved by placing the sheet plate in a high temperature region intensively.

소듐냉각 고속로의 커버가스 영역에서 열유동 해석 (ANALYSIS OF HEAT TRANSFER AND FLUID FLOW IN THE COVER GAS REGION OF SODIUM-COOLED FAST REACTOR)

  • 이태호;김성오;한도희
    • 한국전산유체공학회지
    • /
    • 제13권3호
    • /
    • pp.21-27
    • /
    • 2008
  • The reactor head of a sodium-cooled fast reactor KALIMER-600 should be cooled during the reactor operation in order to maintain the integrity of sealing material and to prevent a creep fatigue. Analyzing turbulent natural convection flow in the cover gas region of reactor vessel with the commercial CFD code CFX10.0, the cooling requirement for the reactor head and the performance of the insulation plate were assessed. The results showed that the high temperature region around reactor vessel was caused by the convective heat transfer of Helium gas flow ascending the gap between the insulation plate and the reactor vessel inner wall. The insulation plate was shown to sufficiently block the radiative heat transfer from pool surface to reactor head to a satisfactory degree. More than $32.5m^3$/sec of cooling air flow rate was predicted to maintain the required temperature of reactor head.

단열 진공유리의 제작 및 열전달계수 측정에 관한 실험적 연구 (Experimental Study on Manufacturing of Insulation Vacuum Glazing and Measurement of the Thermal Conductance)

  • 이보화;윤일섭;곽호상;송태호
    • 대한기계학회논문집B
    • /
    • 제30권8호
    • /
    • pp.772-779
    • /
    • 2006
  • Window is a critical component in the design of energy-efficient buildings. To minimize the heat loss, insulation performance of the glazing has to be improved. Manufacturing of vacuum glazing has been motivated by the possibility of making windows of very good thermal insulation properties for such applications. It is made by maintaining vacuum in the gap between two glass panes. Pillars are placed between them to withstand the atmospheric pressure. Edge covers are applied to reduce conduction through the edge. Accurate measurements have been made of the radiative heat transfer, the pillar conduction and the gas conduction using a guarded hot plate apparatus. Vacuum glazing is found to have low thermal conductance roughly below $1W/m^2K$. Among the heat transfer modes of residual gas conduction, conduction through support pillar and the radiative heat transfer between the glass panes, the last one is the most dominant to the overall thermal conductance. Vacuum glazing using very low emittance AI-coated glass has an overall thermal conductance of about $0.7W/m^2K$.

수직으로 설치된 비균질 평판 단열재용 성능시험장치 개발 (Development of Thermal Performance Tester for Non-Homogeneous Insulation Pannels Installed Vertically)

  • 오홍영;송기오;전현익;조선영
    • 설비공학논문집
    • /
    • 제28권4호
    • /
    • pp.153-157
    • /
    • 2016
  • In case of metal insulation, which is produced by stacking stainless steel sheets and air layers in a multi-stack manner at a specific thickness, insulation performance will be evaluated based on thermal transmittance rather than the intrinsic physical properties of each material such as thermal conductivity. However, there is no standard for measuring thermal transmittance targeted for non-homogeneous insulation which is used in relatively high temperature conditions such as a power station. In this study, the thermal conductivity of homogeneous insulation acquired by the standardized guard hot plate method and the thermal conductivity of homogeneous insulation measured by the newly developed performance tester were compared to verify the confidence level of the tester. As a result, thermal conductivity acquired by the newly developed thermal transmittance tester was about 6% higher than the thermal conductivity measured by the existing guard hot plate method under the anticipated service temperature conditions.

SOFC를 위한 고온용 적층단열재 개발 (Development of Multiple Layers Insulation for SOFC)

  • 최종균;황승식;최규홍
    • 한국수소및신에너지학회논문집
    • /
    • 제29권4호
    • /
    • pp.386-392
    • /
    • 2018
  • Fuel cells are known as eco - friendly energy facilities that can use heat energy and electric energy at the same time. Fuel cells are classified according to the temperature and material used, and solid oxide fuel cell (SOFC) is relatively high temperature ($700-800^{\circ}C$). SOFC requires a hot box consisting of a high temperature stack, a reformer, a burner, and the heat exchangers in order to use energy efficiently. The hot box needs to maintain heat insulation performance at high temperature to reduce heat loss. However, Fibrous insulation, which is widely used, needs to be improved because it has a disadvantage that the thermal conductivity is rapidly increased due to the increase of temperature. Therefore, this study was carried out to develop a thermal insulation, which is applied to multiple layers insulation (MLI) technic, that can be used under SOFC operating conditions and prevent a drastic drop in thermal conductivity at high temperature. The developed insulation is consist of a thermally conductive material, a spacer, and a reflective plate. The thermal conductivity of the insulation was measured by in the thermal conductivity measuring device at high temperature range. As a result, it was confirmed that the developed layers insulation have an good thermal conductivity (0.116 W/mK) than fibrous insulation (0.24 W/mK) as a radiation shielding effect at a high temperature of 1,173 K.

판열유속계를 이용한 복사열유속 측정 실험 (Measurement of Radiative Heat Flux Using Plate Thermometer)

  • 박원희;윤경범
    • 대한기계학회논문집B
    • /
    • 제37권1호
    • /
    • pp.95-98
    • /
    • 2013
  • 고온환경의 복사열유속을 측정하기 위하여 판열유속계를 제작하였다. 열유속은 스테인리스스틸로 제작된 판열속계 뒷면에서 측정된 온도를 이용하여 계산되어진다. 스미트-볼터계로 측정된 열유속을 기준값으로 이용하였다. 단열재로의 열손실, 판열유속계 두께방향으로의 전도 및 평판의 위치에 따라 온도가 상이하여 발생하는 열전달 등을 고려하기 위하여 전도상수를 도입하였다. 이 상수는 반발입자군집 최적화법으로 구하였다.

평판형 히트파이프의 표면온도 분포에 관한 실험적 연구 (An Experimental Study of surface temperature distribution in Flat-Plate Heat Pipe)

  • 주상현;이영수;나호상;조성환
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.635-639
    • /
    • 2007
  • In this study, optimal design and test of flat-plate heat pipe were carried out in order to improve both thermal response and surface temperature uniformity of heating plate. Experimental results show that the thermal response of flat-plate heat pipe is faster than that of a conventional heating type ones along with less weight and cost. The surface temperature uniformity is also improved.