• 제목/요약/키워드: Heat fluxes

검색결과 367건 처리시간 0.025초

ASTER에 의한 청주시주변의 지표면온도 추정 (Estimation of Surface Temperature of the Urban Area in Cheongju Using ASTER Data)

  • 박종화;나상일
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2005년도 학술발표논문집
    • /
    • pp.563-568
    • /
    • 2005
  • Land surface temperature (LST) for large areas can only be derived from surface-leaving radiation measured by satellite sensors. These measurements represent the integrated effect of the surface and are superior to point measurements on the ground, e.g. in Urban Heat Island. ASTER (Advanced Spaceborne Thermal Emission and Reflection Radiometer) is an imaging instrument that is flying on the NASA's Terra satellite launched in December 1999. ASTER acquires 14 spectral bands and can be used to obtain detailed datas of land surface temperature, emissivity, reflectance and elevation. Spatial resolution of 90m of TIR channels of ASTER is useful when we analyze the spatial variations of surface heat fluxes in urban areas. The purpose of this study is to extract the LST using ASTER TIR channels.

  • PDF

비유리식(nonglass) 진공관의 진공도가 집열판의 열적 특성에 미치는 영향 (Effect of Vacuum in a Non-glass Vacuum Tube on the thermal behavior of the Absorber Plate)

  • 오승진;현준호;김남진;이윤준;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제28권3호
    • /
    • pp.67-73
    • /
    • 2008
  • This study has been carried out to investigate the effect of vacuum on the thermal performance of a nonglass evacuated tube. A series of measurements are made indoors to monitor the temperature change of the absorber plate contained in the evacuated tube under different conditions of vacuum and heat fluxes. Those temperatures measured at the thermal equilibrium could be used to assess the heat losses to the ambient in link with the steady operation of non-glass evacuated tubes for solar exploitation.

2상 횡유동을 받는 열교환기 관군의 진동특성 (Vibration Characteristics of Heat Exchanger Tube Bundles in Two-Phase Cross-Flow)

  • 김범식;박태철
    • 소음진동
    • /
    • 제4권2호
    • /
    • pp.199-208
    • /
    • 1994
  • Two-phase cross-flow exists in many shell-tube heat exchangers such as nuclear steam generators, condensers and reboilers. An understanding of damping and of flow-induced vibration excitation mechanisms in necessary to avoid problems due to excessive tube vibration. In this paper, we present the results of experiments on normal-triangular tube bundles of pitch to tube diameter ratio, p/d, 1.22, 1.32 and 1.47. The bundle were subjected to air-water mixtures to simulate realistic mass fluxes and vapour qualities corresponding to void fractions from 5 to 99%. Damping, fluidelastic instability and turbulence- induced excitation are discussed. The behaivior of damping and two vibration mechanisms are different for intermittent flows from for bubbly flows. The effect of pitch to tube diameter ratio and void fraction is dominant on damping and fluidelastic instability.

  • PDF

원통형상에서의 역복사 해석에 관한 연구 (A Study on the Inverse Radiation Analysis in a Cylindrical Enclosure)

  • 김기완;백승욱;유홍선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1516-1521
    • /
    • 2004
  • An inverse boundary analysis of surface radiation in an axisymmetric cylindrical enclosure has been conducted in this study. Net energy exchange method was used to calculate the radiative heat flux on each surface, and a hybrid genetic algorithm was adopted to minimize an objective function, which is expressed by sum of square errors between estimated and measured heat fluxes on the design surface. We have examined the effects of the measurement error as well as the number of measurement points on the estimation accuracy.

  • PDF

복사 난방 패널의 공급유량 및 설계변수가 성능에 미치는 영향 (The Effects of Operating and Design Conditions on the Performance of Radiant Heating Panel)

  • 이태원;김호영
    • 설비공학논문집
    • /
    • 제3권4호
    • /
    • pp.276-285
    • /
    • 1991
  • The transient heat transfer characteristics in the radiant heating panel were predicted by numerical analysis. Thermal behaviors of panel, such as temperature distributions in panel and convective and radiative heat fluxes in panel surface with respect to time were obtained. Heating hours per day, rate of energy supplied and maximum temperature differences at panel surface were also compared for several important parameters. The performance and thermal comfort of heating panel were studied and compared for various operating and design conditions such as pipe pitch, pipe location, pipe diameter and flow rate of hot water for the purpose of producing useful data, which can be used for the test and decision of efficient operating condition of the conventional heating systems or the optimal design of the new panel heating systems.

  • PDF

Hydrogen Permeation of ZnO-SiC Membranes Encapsulated with SiO2

  • Choi, Hyunji;Hwang, Hyeyoun;Jung, Miewon
    • 한국세라믹학회지
    • /
    • 제51권6호
    • /
    • pp.566-569
    • /
    • 2014
  • ZnO and SiC powders were fabricated to make crack-free composite membranes. Parts of some membranes were re-treated with an encapsulation process. These membranes were characterized by XRD, BET, and FE-SEM analyzes. The hydrogen permeation fluxes of the encapsulated and heat-treated membranes after encapsulation were observed using Sievert's type equipment. Values were measured at 1 bar with increasing temperatures. The obtained values of encapsulated and further heat-treated membrane at 298 K were $4.20{\times}10^{-6}$ and $8.64{\times}10^{-5}mol/m^2sPa$, respectively.

병렬 마이크로 채널에서 FC-72의 비등 열전달 특성 (Boiling heat transfer characteristics of FC-72 in parallel micro-channels)

  • 최용석;임태우;유삼상;김환성;최형식
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권9호
    • /
    • pp.1032-1038
    • /
    • 2014
  • 본 연구에서는 병렬 마이크로 채널에서 FC-72의 비등 열전달 특성을 파악하기 위한 실험적 연구를 수행하였다. 병렬 마이크로 채널은 깊이 0.2 mm, 폭 0.45 mm, 길이 60 mm의 15개의 마이크로 채널로 구성되었으며, 실험은 열유속 $16.4kW/m^2$$25.6kW/m^2$의 조건에서 수행되었으며, 이때 질량유속 300, 400 그리고 $500kg/m^2s$의 범위에서 이루어졌다. 실험을 통해 측정된 열전달 계수는 낮은 건도에서는 건도가 증가함에 따라 급격하게 감소하며, 일정 건도 이상에서는 일정하게 유지되었다. 본 연구를 통해 마이크로 채널에서 FC-72의 비등 열전달 메커니즘을 확인하였으며, 실험에서 얻어진 열전달 계수는 열전달 계수를 예측하기 위한 기존의 상관식들과 비교 분석하였다.

탄소나노튜브를 적용한 나노유체의 비등 열전달계수 (Boiling Heat Transfer Coefficients of Nanofluids Using Carbon Nanotubes)

  • 이요한;정동수
    • 한국태양에너지학회 논문집
    • /
    • 제29권5호
    • /
    • pp.35-44
    • /
    • 2009
  • In this study, boiling heat transfer coefficients(HTCs) and critical heat flux(CHF) are measured on a smooth square flat copper heater in a pool of pure water with and without carbon nano tubes(CNTs) dispersed at $60^{\circ}C$. Tested aqueous nanofluids are prepared using multi-walled CNTs whose volume concentrations are 0.0001, 0.001, 0.01, and 0.05%. For dispersion of CNTs, polyvinyl pyrrolidone(PVP) is used in distilled water. Pool boiling HTCs are taken from $10kW/m^2$ to critical heat flux for all nanofluids. Test results show that the pool boiling HTCs of the nanofluids are lower than those of pure water in entire nucleate boiling regime. On the other hand, critical heat flux is enhanced greatly showing up to 200% increase at volume concentration of 0.001% CNTs as compared to that of pure water. This is related to the change of surface characteristics by the deposition of CNTs. This deposition makes a thin CNT layer on the surface and the active nucleation sites of heat transfer surface are decreased due to this layer. The thin layer acts as the thermal resistance and also decreases the bubble generation rate resulting in a decrease in pool boiling HTCs. The same layer, however, maintains the nucleate boiling even at very high heat fluxes and reduces the formation of large vapor canopy at near CHF resulting in a significant increase in CHF.

고온 강재의 담금질 열전달에 관한 연구 제1보 : 과냉과도 비등열전달과 냉각곡선 (A Study on the Heat Transfer of the High Temperature Metals in Quenching 1st Reprot; Subcooled Transient Boiling Heat Transfer and Colling Curves)

  • 윤석훈;홍영표;김경근;김용모
    • 대한기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.1529-1540
    • /
    • 1993
  • 본 연구에서는 금속 열처리를 위한 고온면의 막비등 급냉각에 관한 1차적 연구로서 과냉과도 비등곡선의 정확한 형상과 냉각제의 냉각조건이 강재의 과냉과도 비등열전달에 미치는 영향, $A_1$변태점 부근의 $A_1$냉각속도와 상변태열량광의 관계, 그리고 상변태열이 냉각곡선에 미치는 영향 등을 규명하고자 한다.

복사열을 이용한 샌드위치 패널 심재의 연소특성 분석 (A Combustion Characteristic Analysis of Sandwich Panel Core Using Radiation Heat Flux)

  • 박형주
    • 한국화재소방학회논문지
    • /
    • 제21권4호
    • /
    • pp.25-31
    • /
    • 2007
  • 본 연구에서는 샌드위치 패널 심재에 대한 연소열과 일정한 외부 복사열에 의한 연소특성을 분석하였다. 일정한 외부 복사열원에 노출된 샌드위치 패널 심재의 착화시간, 임계열유속, 착화온도, 시료 표면 온도의 변화를 측정하기 위해 3가지 Type의 시료를 사용하였으며, 연소열을 측정하기 위해 Oxygen bomb calorimeter를, 연소특성을 측정하기 위해 Mass loss calorimeter를 사용하였다. 연소특성을 측정하기 위해 $100\;mm{\times}100\;mm{\times}50\;mm$ 크기의 시료를 사용하였다. 연구결과, 연소열과 착화온도에 있어서 가장 좋은 특성을 갖는 것은 Type B인 반면 임계열유속과 시료 표면온도 변화에 있어서는 Type C에서 가장 좋은 특성을 나타내었다. 모든 연구 데이터를 종합한 결과 Type C가 가장 좋은 화재안정성을 나타낸다는 것을 알 수 있었다. 향후, 샌드위치 패널 심재에 대한 열방출률 특성과 질량감소속도에 대한 실험연구가 필요할 것으로 판단된다.