• 제목/요약/키워드: Heat distribution

검색결과 2,932건 처리시간 0.029초

유한 요소법을 이용한 $CO_2$아아크 용접부의 용입깊이와 열영향부 크기 예측 (Prediction of Penetration and Heat Affected Zone by Using Finite Element Method in $CO_2$ Arc Welding)

  • 이정익;박일철;박기영;엄기원
    • Journal of Welding and Joining
    • /
    • 제10권4호
    • /
    • pp.222-229
    • /
    • 1992
  • A prediction of penetration and heat affected zone by using Finite Element Method in CO$_{2}$ Arc Welding has been discussed this paper. The temperature distribution of a base metal produced by the CO$_{2}$ arc welding processing is analyzed by using a three dimensional finite element model. The common finite element program ANSYS 4.4A was employed to obtain the numerical results. Temperature dependent material properties, effect of latent heat, and the convective boundary conditions are included in the model. Numerically predicted sizes of the penetration and the heat affected zone are compared with the experimentally observed values. As a result, there was a slight difference between numerical analysis values and experimentally observed values. For in the case of heat affected zone, it was not considered a precise forced convective coefficient value, and in the case of penetration, it was not, considered a arc force.

  • PDF

회전덕트에서 요철 배열 및 회전수 변화에 따른 열전달 특성 (EFFECTS OF RIB ARRANGEMENTS AND ROTATION ON HEAT TRANSFER IN A ROTATING TWO-PASS DUCT)

  • 김경민;김윤영;이동호;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.2211-2218
    • /
    • 2003
  • The present study investigates heat/mass transfer characteristics in a rotating two-pass duct for smooth and ribbed surfaces. The duct has an aspect ratio of 0.5 and a hydraulic diameter of 26.67 mm. 70-angled rib turbulators are attached on the leading and trailing sides of the duct in parallel and cross arrangements. The pitch-to-rib height ratio is 7.5 and the rib height-to-hydraulic diameter ratio is 0.075. The Reynolds number based on the hydraulic diameter is constant at 10,000 and the rotation number ranges from 0.0 to 0.2 Detailed local heat/mass transfer coefficients are measured using a naphthalene sublimation technique. The results show that the secondary flows generated by the $180^{\circ}-turn$, rib turbulators, and duct rotation affect the wall heat/mass transfer distribution significantly, As the duct rotates, the rotaion-induced Coriolis force deflects the main flow and results in differences on the heat/mass transfer distribution between the leading and trailing surfaces. Its effects become more dominant as the rotaion number increases. Discussions are presented describing how the rib configuration and the rotaion speed affect the flow patterns and local heat/mass transfer in the duct.

  • PDF

스케일 층의 생성 및 성장을 고려한 가열로 내 슬랩의 승온 특성 해석에 관한 연구 (A Numerical Study on the Slab Heating Characteristics in a Reheating Furnace with the Formation and Growth of Scale on the Slab Surface)

  • 이동은;장정현;김종민;홍동진;박해두;박윤범;김만영
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.109-112
    • /
    • 2008
  • In this work, a mathematical heat transfer model of a walking-beam type reheating furnace that can predict the formation and growth of the scale layer, which is produced due to oxidative reaction between the furnace oxidizing atmosphere and the steel surface in the reheating furnace, has been developed. The model can also predict the heat flux distribution within the furnace and the temperature distribution in the slab and scale throughout the reheating furnace process by considering the heat exchange between the slab and its surroundings in the furnace, including radiant heat transfer among the slabs, the skids, the hot gases and the furnace wall as well as the gas convection heat transfer in the furnace. Using the model developed in this work, the effects of the scale layer on the heat transfer characteristics and temperature behavior of the slab is investigated. A comparison is also made between the predictions of the present model and the data from an in situ measurement in the furnace, and a reasonable agreement is founded.

  • PDF

SKD11 절단금형치구용 소재의 마모손상에 관한 연구 (A study on wear damage of SKD11 steel material for a cutting mold jig)

  • 남기우;김철수;안석환
    • 동력기계공학회지
    • /
    • 제20권5호
    • /
    • pp.5-13
    • /
    • 2016
  • This study is on wear damage of the material for a molding machine that be used at finally cutting of metal beam made in roll forming process of vehicle bump beam process line. SKD11 steel was used with the material for cutting mold jig. In the cutting mold jig, Ti diffusion heat treatment after vacuum heat treatment was carried out for upgrade of surface hardness and anti-wear. Also, the heat treatments by various methods were performed to compare the wear damage degree against above the existing heat treatment. Wear loss and friction coefficient were obtained from wear test. And, micro Vickers hardness values were compared with damaged parts or not of cutting mold jig. Micro Vickers hardness value appeared higher at the undamaged part by Ti diffusion heat treatment. The micro Vickers hardness well followed a two-parameter Weibull probability distribution.

자동차용 라디에이터 열유동 특성에 관한 수치해석 (Numerical Analysis on the Characteristics of Thermal Flow in an Automobile Radiator)

  • 강창원;김태준;이치우
    • 한국기계가공학회지
    • /
    • 제18권6호
    • /
    • pp.55-61
    • /
    • 2019
  • The purpose of this study was to numerically analyze the heat flow characteristics of an automotive radiator. Heat flow analyses were conducted on the cooling water and outdoor air of the radiator, as well as the temperature distribution of the cooling water after heat transfer. The results of the study revealed that neither heat transfer nor radiator volume was affected by the position of the inlet of cooling water. However, temperature distribution was affected by the position of both the inlet and outlet. In case of heat transfer, three models underwent about 158 kW of heat transfer. The difference in cooling water temperature was about $10^{\circ}C$. In case of pressure drop, the core external air side was reduced to about 1,375 Pa, and the internal cooling water side about 14,570 Pa.

30W급 LED 투광등의 풍속에 따른 히트싱크 온도분포에 관한 실험적 연구 (An Experimental Study on Heatsink Temperature Distribution according to the Wind Speed of a 30W LED Floodlight)

  • 이영호;김대언;정한식;정효민;이중섭
    • 한국기계가공학회지
    • /
    • 제18권5호
    • /
    • pp.96-102
    • /
    • 2019
  • This study investigated the heat dissipation characteristics of a heat-sensitive LED. More than 80% of the power supply is converted into heat energy, which has a fatal impact on the lifetime of the LED. Therefore, the effective heat dissipation characteristics of a heatsink, such as a 30W floodlight, through forced convection were grasped and the heat transfer characteristics were tested. As a result, it was confirmed that the smaller the number of fins, the more the temperature distribution varies according to the wind velocity. In addition, the larger the number of fins, the smaller the temperature difference according to the wind velocity. Therefore, it was found through this experiment that excellent heat dissipation performance was exhibited as the heat dissipation area and wind velocity increased.

한국연안의 표면해수와 대기간의 열교환 (Heat Exchange At The Sea Surface In The Korean Coastal Seas)

  • 봉종헌
    • 한국해양학회지
    • /
    • 제11권2호
    • /
    • pp.43-50
    • /
    • 1976
  • 해양과 대기간의 열교환에 관한 문제는 세계적으로 여러 학자들의 연구에 의해서 강조되어 온 바와 같이 해양학과 기상학에서 매우 중요한 비중을 차지하고 있는 분야 로서 선진제국의 이에 대한 관심과 연구열은 매우 다대하다. 한국근해에서의 해양과 대기간의 열교환에 관하여는 Jacobs(1951), Manabe(1957, 1958), Ninomiya(1964,1968) Wyrtki(1965, 1968), Takahashi(1969), Moriyasu(1952, 1969), Ishida(1970) 및 한( 1970, 1972) 등의 조사보고가 있으나 이들은 대개 한국근해를 중심으로 다루어진 것이 아니거나 시기적으로 또는 지역적으로 국한되어 있는 것이므로 우리나라 근해에서의 전반적인 열교환에 관하여는 보고된 바가 거의 없는 실정이다.

  • PDF

화재열차의 역사 접근 시 PSD가 설치된 역사 제연을 위한 환기장치 운전 비정상상태 해석 (A transient CFD simulation of ventilation system operation for smoke control in a subway station equipped with a Platform Screen Door(PSD) when a train under fire is approaching the station)

  • 신규호;허남건;원찬식
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.269-272
    • /
    • 2006
  • The heat and smoke which generated by subway under fire is one of the most harmful factor in air tighten underground station. To prevent this, Trackway Exhaust System(TES) can be used. The heat released from the train running in the tunnel raises the temperature at the platform and the trackway, and thus proper ventilation system is required for comfortable underground environment. When the fire is occurred, TES is operated as smoke exhaust mode from normal ventilation mode. In the present study, the subway station which is one of the line number 9 in Seoul subway is modeled, and fired situation is simulated with several ventilation mode of ventilation system in trackway. For this simulation whole station is modeled. Non steady state 3D simulation which considered train under fire is entering to the station is performed. Temperature and smoke distribution in platform and trackway are compared. To represent heat by fire, heat flux was given to the fired carriage, also to describe smoke by fire, concentration of CO is represented. As the result of present study, temperature and smoke distribution is different as the method of ventilation in trackway and platform is changed. In over side of trackway, the fan must be operated as exhaust mode for efficient elimination of heat and smoke, and supply mode of fan operation in under side shows better distribution of heat and smoke. The ventilation system which is changed from ventilation mode to exhaust mode can be applied to control heat and smoke under fire.

  • PDF

고층 공동주택의 개구특성에 따른 화재시 열.연기유동에 관한 연구 (Distribution of Heat and Smoke Related to Openings in Hise-Rise Apartment Building Fires)

  • 이지희
    • 한국화재소방학회논문지
    • /
    • 제15권2호
    • /
    • pp.59-79
    • /
    • 2001
  • 본 연구는 우리나라 고층 공동주택의 화재에 대한 안전성을 강조하고, 화재 발생시의 인명피해와 재산 피해를 감소시키기 위해서 개구특성에 따른 화재시 열·연기 유동에 관한 연구를 통하여 계획적 측면의 화재 안전성 방향을 제시하고자 하였다. 열유동해석 프로그램을 구축하고 그것을 이용해서 공동주택의 개실과 단위주호 그리고 단위주도을 대상으로 수치해석과 실험해석을 병행하였다. 그 결과, 고층 공동주택의 개실에서 개구의 개폐유형이 화재의 열 및 연기유동에 영향을 끼치므로 평면계획시 개구유형에 따른 별도의 방화대책을 강화해야 하며, 두 번째, 고층 공동주택의 단위주호에 있어서 평면유형에 따라서, 열과 연기의 전파시간에 차이가 있음을 수치해석을 통해서 그 결과를 유도했으며, 세 번째, 단위주동을 대상으로 했을 때, 개구 개폐유형에 따라 열 및 연기유동의 수치해석과 모형실험을 통해서 화재성상에 차이가 있음을 알 수 있었다.

  • PDF

전력제어 반도체용 히트파이프 냉각기의 열전달 성능 연구 (A Study on Heat Transfer Performances of a Heat Pipe Heat Sink for Power Control Semiconductors)

  • 강환국;김재진;김철주
    • 설비공학논문집
    • /
    • 제13권8호
    • /
    • pp.701-709
    • /
    • 2001
  • In this days, heat pipe heat sink has been widely applied to power controllers for railway substations to remove heat from power semiconductors(diodes or thyristors). The heat pipe heat sink consists of a aluminum heating block for mounting the thyristor, 2~3 heat pipes and large number of aluminum fins. The present study was to get fundamental informations of the structure, design parameters and heat transfer performances of heat pipe heat sink. Series of operational test for a unit with 3 heat pipes were performed and its heat flow circuit was analysed from the experimentally obtained data on wall temperature distribution. Total resistance was ranged 0.02~$0.03^{\circ}C$/W for a power range from 40W to400W. The time to get the steady state was approximately longer than 20 minutes, and overshooting was not occurred during start up operation.

  • PDF