• Title/Summary/Keyword: Heat distribution

Search Result 2,932, Processing Time 0.031 seconds

Surveillance of Acanthamoeba spp. and Naegleria fowleri in environmental water by using the duplex real-time PCR (Duplex real-time PCR을 이용한 수계 중 가시아메바와 파울러자유아메바 조사)

  • Kim, Min-jeong;Lee, Gyu-Cheol;Kim, Kunwoo;Lee, Hyunji;Kim, Min Young;Seo, Dae Keun;Lee, Jeong Yeob;Cho, Young-Cheol
    • Korean Journal of Microbiology
    • /
    • v.54 no.2
    • /
    • pp.98-104
    • /
    • 2018
  • Naegleria fowleri and Acanthamoeba spp. are free-living amoebas that are widely distributed in natural environments. Although uncommon, infection with these protozoans can cause fatal disease in humans and animals. In this study, in order to select the appropriate method to survey Naegleria fowleri and Acanthamoeba spp. in water samples, four molecular biology techniques and one commercially available kit for real-time PCR were compared. The results indicated that the duplex real-time PCR was the most sensitive, and could be used to simultaneously detect two different free-living amoebas. Using the duplex real-time PCR approach, the two free-living amoebas were surveyed in three local streams in Daejeon, Republic of Korea. The concentrated free-living amoebas were inoculated onto non-nutrient agar plates which had been spread with heat-inactivated Escherichia coli and incubated for 5~7 days. After incubation, gDNA was extracted and used as the template for amplification by duplex real-time PCR. Acanthamoeba spp. and N. fowleri was detected from ten (83.3%) and two (16.6%) of the twelve samples, respectively. As these two free-living amoebas can be fatal, continuous surveillance is needed to track their distribution in the aquatic environment for the drinking water safety.

Evaluation on the External Restraint Stress in Mass Concrete (매스콘크리트의 외부구속응력에 관한 검토)

  • 강석화;정한중;박칠림
    • Magazine of the Korea Concrete Institute
    • /
    • v.8 no.5
    • /
    • pp.111-122
    • /
    • 1996
  • The effects of external restraint on the thermal stresses i n mass concrete are investigated through a series of parametric study. Two major factors affecting the degree of external restraint such as the ratio of length to height of the placed structure (L/H) and the elastic modulus of base structure ($E_r$) are employed as the parameters in a condition which a placing height H is 1.0m. Various conditions of I,/H and E, are analysed by a FEM program and the relationship between these two parameters is examined. The shape of stress distribution due to the external restraint is shown as linearity on the height direction of the section, and is influenced by L/H, $E_r$, and strength development of placed concrete. The external restraint can be devided by two part. One is an axial restraint and the other is a flexural restraint. When the level of external restraint is low, the structure behavior is mainly governed by flexural restraint, otherwise it is dependent on axial restraint. Comparing the calculated stress by the method of the ACI 207 committee with a finite element analysis, the fbrmer overestimates the external restraint stress when the degree of external restraint is weak, and underestimates when it is strong.

Development of 3D printer heating block using clad plate material (클래드 판재를 사용한 3D 프린터 히팅 블록 개발)

  • Won, Dae-Hee
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.4
    • /
    • pp.199-205
    • /
    • 2017
  • In this study, the design analysis and the explosion welding were made into a clad sheet by the convergence method in order to solve the problem of heat transfer to the guide due to the heating of the 3D printer heating block. The shear strength of the clad plate material was tested and the results were analyzed by thermal analysis, thermal conductivity and thermal imaging. The following conclusions were obtained. 3D modeling of the heating block made of copper and titanium clad plate material The thermal analysis showed that the surface temperature of the filament guide area was lower than the heating block surface temperature. The average shear strength of copper and titanium clad plate material was measured and the average value of 195.6MPa was obtained. The thermal conductivity of the heating block made of copper and titanium clad plate material was measured three times and the average value was $62.52W/m{\cdot}K$. The surface temperature of the heating block made of copper and titanium clad plate material was measured by a thermal imaging camera at a maximum of $107.3^{\circ}C$ and $183.2^{\circ}C$ at the filament guide. The temperature distribution was $89^{\circ}C$ lower than that of the existing filament.

Electrochemical Characteristics of Sn Added Li4Ti5O12 as an Anode Material (Sn이 첨가된 Li4Ti5O12 음극활물질의 전기화학적 특성)

  • Jeong, Choong-Hoon;Kim, Sun-Ah;Cho, Byung-Won;Na, Byung-Ki
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.1
    • /
    • pp.16-21
    • /
    • 2011
  • $Li_4Sn_xTi_{5-x}O_{12}$ was manufactured by high energy ball milling (HEBM) and used as an anode material for lithium ion battery. Various amount of $SnO_2$was added to $Li_4Ti_5O_{12}$ and heated at different temperatures. The purpose of this research was to see the effect of $SnO_2$ addition into $Li_4Ti_5O_{12}$. Manufactured samples were analyzed by TGA, XRD, SEM, PSA. Battery cycler was used to test the charge/discharge properties of active materials. Heat treatment temperature of $800^{\circ}C$ was needed to make a stable structure of $Li_4Sn_xTi_{5-x}O_{12}$ and the particle size distribution was $0.2{\sim}0.6\;{\mu}m$. Charge/discharge process was repeated for 50 cycles at room temperature. The initial capacity was 168mAh/g and the voltage plateau was observed at 1.55V(Li/$Li^+$).

Thermo-mechanical Behavior Characteristic Analysis of $B^2it$(Buried Bump Interconnection Technology) in PCB(Printed Circuit Board) (인쇄회로기판 $B^2it$(Buried Bump Interconnection Technology) 구조의 열적-기계적 거동특성 해석)

  • Cho, Seung-Hyun;Chang, Tae-Eun
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.16 no.2
    • /
    • pp.43-50
    • /
    • 2009
  • Although thin PCBs(Printed Circuit Boards) have recently been required for high density interconnection, high electrical performance, and low manufacturing cost, the utilization of thin PCBs is severely limited by warpage and reliability issues. Warpage of the thin PCB leads to failure in solder-joints and chip. The $B^2it$(Buried Bump Interconnection Technology) for PCB has been developed to achieve a competitive manufacturing price. In this study, chip temperature, package warpage, chip stress and solder-joints stress characteristics of the PCB prepared with $B^2it$ process have been calculated using thermo-mechanical coupled analysis by the FEM(Finite Element Method). FEM computation was carried out with the variations in bump shapes and kinds of materials under 1.5W power of chip and constant convection heat transfer. The results show that chip temperature distribution reached more quickly steady-state status with PCB prepared with $B^2it$ process than PCB prepared with conventional via interconnection structure. Although $B^2it$ structures are effective on low package warpage and chip stress, with high strength bump materials arc disadvantage for low stress of solder-joints. Therefore, it is recommended that optimized bump shapes and materials in PCB design should be considered in terms of reliability characteristics in the packaging level.

  • PDF

Study of Benefit Characteristics for Low Impact Development (LID) Facilities demonstrated in Seoul Metropolitan (서울시 저영향개발(LID) 시범 시설에 대한 편익 특성 연구)

  • Lee, Seung Won;Kim, Reeho
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.6
    • /
    • pp.299-308
    • /
    • 2016
  • Seoul metropolitan has established a vision as 'Healthy water-cycle city' to resolve urban water-environmental deterioration. And it established administrative structure to expand Low Impact Development (LID) facilities to recover aggravated water-cycle and water-environment. Therefore, various LID facilities are constructed and operated, however, benefit analytic plans for systematic valuation are insufficient. In this study, to analyze economic, environmental and social benefits of LID facilities, contents for benefit analysis were selected and categorized as water, energy, air quality and climate changes. As a result of quantification and valuation to the beneficial effects, LID facilities showed the total benefit as 1,191~3,292 won/yr. Characteristics of benefit distribution by analysis contents were various reflecting functional characteristics of each LID facility (Water: 30~90%, Energy: 4~44%, Air quality: <1~2%, Climate change: 5~22%). As a result of Triple Bottom Line analysis, economic benefit showed the greatest portion as 75~90%. As further studies, suggested benefit assessment plans for each LID facility should be applied to inter-connected LID systems on complex-scaled area, and synergy effects by various LID systems would be evaluated such as prevention of heat island and flood disasters.

Adsorption Characteristics of Reactive Red 120 by Coal-based Granular Activated Carbon : Isotherm, Kinetic and Thermodynamic Parameters (석탄계 입상활성탄에 의한 Reactive Red 120의 흡착 특성 : 등온선, 동력학 및 열역학 파라미터)

  • Lee, Jong Jib
    • Applied Chemistry for Engineering
    • /
    • v.31 no.2
    • /
    • pp.164-171
    • /
    • 2020
  • Adsorption characteristics of reactive red 120 (RR 120) dye by a coal-based granular activated carbon (CGAC) from an aqueous solution were investigated using the amount of activated carbon, pH, initial concentration, contact time and temperature as adsorption variables. Isotherm equilibrium relationship showed that Langmuir's equation fits better than that of Freundlich's equation. The adsorption mechanism was considered to be superior to the adsorption of monolayer with uniform energy distribution. From the evaluated Langmuir separation coefficients (RL = 0.181~0.644), it was found that this adsorption process belongs to an effective treatment area (RL = 0~1). The adsorption energy determined by Temkin's equation and Dubinin-Radushkevich's equation was E = 15.31~7.12 J/mol and B = 0.223~0.365 kJ/mol, respectively. The adsorption process showed the physical adsorption (E < 20 J/mol and B < 8 kJ/mol). The adsorption kinetics followed the pseudo first order model. The adsorption reaction of RR 120 dye on CGAC was found to increase spontaneously with increasing the temperature because the free energy change decreased with increasing the temperature. The enthalpy change (12.747 kJ/mol) indicated an endothermic reaction. The isosteric heat of adsorption (△Hx = 9.78~24.21 kJ/mol) for the adsorption reaction of RR 120 by CGAC was revealed to be the physical adsorption (△Hx < 80 kJ/mol).

Flow blockage analysis for fuel assembly in a lead-based fast reactor

  • Wang, Chenglong;Wu, Di;Gui, Minyang;Cai, Rong;Zhu, Dahuan;Zhang, Dalin;Tian, Wenxi;Qiu, Suizheng;Su, G.H.
    • Nuclear Engineering and Technology
    • /
    • v.53 no.10
    • /
    • pp.3217-3228
    • /
    • 2021
  • Flow blockage of the fuel assembly in the lead-based fast reactor (LFR) may produce critical local spots, which will result in cladding failure and threaten reactor safety. In this study, the flow blockage characteristics were analyzed with the sub-channel analysis method, and the circumferentially-varied method was employed for considering the non-uniform distribution of circumferential temperature. The developed sub-channel analysis code SACOS-PB was validated by a heat transfer experiment in a blocked 19-rod bundle cooled by lead-bismuth eutectic. The deviations between the predicted coolant temperature and experimental values are within ±5%, including small and large flow blockage scenarios. And the temperature distributions of the fuel rod could be better simulated by the circumferentially-varied method for the small blockage scenario. Based on the validated code, the analysis of blockage characteristics was conducted. It could be seen from the temperature and flow distributions that a large blockage accident is more destructive compared with a small one. The sensitivity analysis shows that the closer the blockage location is to the exit, the more dangerous the accident is. Similarly, a larger blockage length will lead to a more serious case. And a higher exit temperature will be generated resulting from a higher peak coolant temperature of the blocked region. This work could provide a reference for the future design and development of the LFR.

A Review and Analysis of the Thermal Exposure in Large Compartment Fire Experiments

  • Gupta, Vinny;Hidalgo, Juan P.;Lange, David;Cowlard, Adam;Abecassis-Empis, Cecilia;Torero, Jose L.
    • International Journal of High-Rise Buildings
    • /
    • v.10 no.4
    • /
    • pp.345-364
    • /
    • 2021
  • Developments in the understanding of fire behaviour for large open-plan spaces typical of tall buildings have been greatly outpaced by the rate at which these buildings are being constructed and their characteristics changed. Numerous high-profile fire-induced failures have highlighted the inadequacy of existing tools and standards for fire engineering when applied to highly-optimised modern tall buildings. With the continued increase in height and complexity of tall buildings, the risk to the occupants from fire-induced structural collapse increases, thus understanding the performance of complex structural systems under fire exposure is imperative. Therefore, an accurate representation of the design fire for open-plan compartments is required for the purposes of design. This will allow for knowledge-driven, quantifiable factors of safety to be used in the design of highly optimised modern tall buildings. In this paper, we review the state-of-the-art experimental research on large open-plan compartment fires from the past three decades. We have assimilated results collected from 37 large-scale compartment fire experiments of the open-plan type conducted from 1993 to 2019, covering a range of compartment and fuel characteristics. Spatial and temporal distributions of the heat fluxes imposed on compartment ceilings are estimated from the data. The complexity of the compartment fire dynamics is highlighted by the large differences in the data collected, which currently complicates the development of engineering tools based on physical models. Despite the large variability, this analysis shows that the orders of magnitude of the thermal exposure are defined by the ratio of flame spread and burnout front velocities (VS / VBO), which enables the grouping of open-plan compartment fires into three distinct modes of fire spread. Each mode is found to exhibit a characteristic order of magnitude and temporal distribution of thermal exposure. The results show that the magnitude of the thermal exposure for each mode are not consistent with existing performance-based design models, nevertheless, our analysis offers a new pathway for defining thermal exposure from realistic fire scenarios in large open-plan compartments.

Analysis of Environmental Equity of Green Space Services in Seoul - The Case of Jung-gu, Seongdong-gu and Dongdaemun-gu - (서울지역 녹지서비스의 환경형평성 분석 - 중구, 성동구, 동대문구를 사례로 -)

  • Ko, Young Joo;Cho, Ki-Hwan;Kim, Woo-Chan
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.47 no.2
    • /
    • pp.100-116
    • /
    • 2019
  • Urban green spaces, as a means to mitigate social problems and environmental risks, are getting more attention in evaluating urban environment. The inequity of green space distribution is becoming a major issue in urban planning and management. This study investigated the characteristics of green space in 3 districts (Jung-gu, Dongdaemun-gu, Seongdong-gu), that are composed of 46 administrative divisions in central Seoul, to analyze the environmental equity of urban green spaces. The correlations between the amount of green space, including the coverage of street trees, and the socioeconomic status of each administrative division were analyzed. To deduce the effects of plant coverage on the urban temperature regime, the relationship between the normalized difference of vegetation index (NDVI) and land surface temperature (LST) was analyzed. The research revealed that the mean NDVI of an administrative division was negatively correlated with the percentage of basic living recipients and disabled people. The LST of a division with low NDVI was higher due to the lack of green coverage. Such environmental inequities were closely related to residential building type, which was strongly affected by the economic status of residents. The LST of an apartment area was $2.0^{\circ}C$ lower than that of single-family houses and multi-housing areas. This is expected as the average NDVI of the apartment area was more than twice as high as the other environments considered in this study. The inequity can be exacerbated without urban planning which is deliberately designed to reduce it.