An Efficient Chloride Ingress Model for Long-Term Lifetime Assessment of Reinforced Concrete Structures Under Realistic Climate and Exposure Conditions

  • Nguyen, Phu Tho;Bastidas-Arteaga, Emilio;Amiri, Ouali;Soueidy, Charbel-Pierre El
    • International Journal of Concrete Structures and Materials
    • /
    • v.11 no.2
    • /
    • pp.199-213
    • /
    • 2017
  • Chloride penetration is among the main causes of corrosion initiation in reinforced concrete (RC) structures producing premature degradations. Weather and exposure conditions directly affect chloride ingress mechanisms and therefore the operational service life and safety of RC structures. Consequently, comprehensive chloride ingress models are useful tools to estimate corrosion initiation risks and minimize maintenance costs for RC structures placed under chloride-contaminated environments. This paper first presents a coupled thermo-hydro-chemical model for predicting chloride penetration into concrete that accounts for realistic weather conditions. This complete numerical model takes into account multiple factors affecting chloride ingress such as diffusion, convection, chloride binding, ionic interaction, and concrete aging. Since the complete model could be computationally expensive for long-term assessment, this study also proposes model simplifications in order to reduce the computational cost. Long-term chloride assessments of complete and reduced models are compared for three locations in France (Brest, Strasbourg and Nice) characterized by different weather and exposure conditions (tidal zone, de-icing salts and salt spray). The comparative study indicates that the reduced model is computationally efficient and accurate for long-term chloride ingress modeling in comparison to the complete one. Given that long-term assessment requires larger climate databases, this research also studies how climate models may affect chloride ingress assessment. The results indicate that the selection of climate models as well as the considered training periods introduce significant errors for mid- and long- term chloride ingress assessment.

A Study on Thermal Analytical Model for a Dry Dual Clutch (건식 듀얼 클러치의 열해석 모델에 대한 연구)

  • Liu, Hao;Lee, J.C.;Noh, Y.J.;Cho, J.H.;Lee, H.R.;Koh, J.E.;Kang, J.W.
    • Journal of Drive and Control
    • /
    • v.12 no.1
    • /
    • pp.1-8
    • /
    • 2015
  • The stability of friction characteristics and thermal management for a dry type dual clutch transmission (DCT) are inferior to those of a wet clutch. Too high temperature resulting from frequent engagement of DCT speeds up degradation or serious wear of the pressure plate or burning of the clutch disk lining. Even though it is significantly important to estimate the temperature of a dry double clutch (DDC) in real-time, few meaningful study of the thermal model of DDC has been known yet. This study presented a thermal analytical model of lumped parameters for a DDC by analyzing its each component firstly. Then a series of experimental test was carried out on the test bench with a patented temperature telemetry system to validate the proposed thermal model. The thermal model, whose optimal parameter values were found by optimization algorithm, was also simulated on the experimental test conditions. The simulation results of DDC temperature show consistency with the experiment, which validates the proposed thermal model of DDC.

Design of Levitation Magnet with Thermal Analysis (열해석을 이용한 자기부상자석의 설계)

  • Bae, Duck-Kweon;Sung, Ho-Kyung;Yoon, Yong-Soo;Bae, Jun-Han;Jho, Jeong-Min;Kim, Dong-Sung
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1185-1186
    • /
    • 2007
  • The UTM-01 developed in 1998 was the first maglev vehicle in Korea for the urban transit maglev (UTM) system. Through the improvement of UTM-01 and development of UTM02, the commercialization of the UTM system is being prepared now. In order to prepare for the commercialization of maglev, it is necessary that an optimal design of the levitation magnet should be provided for the safe operation of the vehicle. The levitation force is formed through the function of magnetic flux density on the top of magnet poles and gap between magnet pole and guide rail. To generate a magnetic field that is high enough to levitate the vehicle, ferromagnetic materials, such as pure iron for magnet pole and SS400 for guide rail, were used. The heat generated by $I^2R$ loss of magnet conductor makes the thermal convection on the surface of magnet including coil and poles. As these two characteristics are nonlinear phenomena, this paper deals with the nonlinear analysis on the magnetic and thermal properties of the U-type levitation magnet by using 3-D finite element method (FEM). Base on the analysis results, a small scale U-type magnet was designed, manufactured, and tested and it was verified that the magnet manufactured was satisfactory to all the design specifications.

  • PDF

Experimental and Numerical Investigation of the Performance of Vertical Thermosyphon for Frozen Ground Stabilization (실험과 수치해석을 통한 동토지반 안정화용 수직형 열사이펀의 성능평가)

  • Lee, Jangguen;Lee, Chulho;Jang, Changkyu;Choi, Changho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.13 no.4
    • /
    • pp.45-56
    • /
    • 2014
  • Frozen ground in cold region consists of an upper active layer and lower permafrost which is permanently frozen land. During the summer season, the air temperature is high enough to make the frozen ground melt, which causes the reduction of soil strength and thaw settlement. These phenomena result in structural instability, so it is necessary to apply frozen ground stability techniques. Thermosyphon is a closed natural two-phase convection device to maintain the ground temperature below $0^{\circ}C$ by extracting heat from the ground and discharges it into the atmosphere. Experimental and numerical investigation has been performed to estimate the effect of the refrigerant filling ratio in thermosyphon using R-134a refrigerant and the thermal conductance of the thermosyphon.

Estimation of Agricultural Produce Drying Using Ultrasonic (초음파를 이용한 농산물의 건조특성 분석)

  • Khmelev, Vladimir N.;Choo, Kwang-Moon
    • Journal of agriculture & life science
    • /
    • v.43 no.6
    • /
    • pp.111-115
    • /
    • 2009
  • This study was conducted to develop the ultrasonic dryer because present drying methods (heat convection, microwave, vacuum, etc.) could not improve the drying consumption energy, decrease of quality and drying ratio by physical limitation. The drying tests were conducted with four levels (No. 1 only non-heated air, No. 2 only ultrasonic, No. 3 only heated air and No. 4 ultrasonic with heated air) and measuring weight of samples after drying carrot and ginseng slices for 30 minutes. The result of test is that the drying ratio was highest in the level of No. 4 ultrasonic with heated air. The sliced carrot's drying ratio was 22.4% (w.b.)/h and sliced ginseng's drying ratio was 3.8% (w.b.)/h. The discoloration and twist of samples was appeared on using only heated air like No. 3.

Development of a 3 kW Grid-tied PV Inverter With GaN HEMT Considering Thermal Considerations (GaN HEMT를 적용한 3kW급 계통연계 태양광 인버터의 방열 설계 및 개발)

  • Han, Seok-Gyu;Noh, Yong-Su;Hyon, Byong-Jo;Park, Joon-Sung;Joo, Dongmyoung
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.5
    • /
    • pp.325-333
    • /
    • 2021
  • A 3 kW grid-tied PV inverter with Gallium nitride high-electron mobility transistor (GaN HEMT) for domestic commercialization was developed using boost converter and full-bridge inverter with LCL filter topology. Recently, many GaN HEMTs are manufactured as surface mount packages because of their lower parasitic inductance characteristic than standard TO (transistor outline) packages. A surface mount packaged GaN HEMT releases heat through either top or bottom cooling method. IGOT60R070D1 is selected as a key power semiconductor because it has a top cooling method and fairly low thermal resistances from junction to ambient. Its characteristics allow the design of a 3 kW inverter without forced convection, thereby providing great advantages in terms of easy maintenance and high reliability. 1EDF5673K is selected as a gate driver because its driving current and negative voltage output characteristics are highly optimized for IGOT60R070D1. An LCL filter with passive damping resistor is applied to attenuate the switching frequency harmonics to the grid-tied operation. The designed LCL filter parameters are validated with PSIM simulation. A prototype of 3 kW PV inverter with GaN HEMT is constructed to verify the performance of the power conversion system. It achieved high power density of 614 W/L and peak power efficiency of 99% for the boost converter and inverter.

Effect of Flight Altitude on Minimal Infrared Signature of Combat Aircraft (고도 변화에 따른 전투기 적외선 신호 최소 조건 분석)

  • Nam, Juyeong;Chang, Injoong;Lee, Yongwoo;Kim, Jihyun;Cho, Hyung Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.33 no.6
    • /
    • pp.375-382
    • /
    • 2020
  • Owing to the rapid development of infrared guided weapon systems, the threat to aircraft survivability is constantly increasing, and research on infrared stealth technologies are being conducted to ensure aircraft survival. In this study, we analyze the minimum infrared signature of an aircraft according to its flight altitude by considering the characteristics of infrared guided missiles, which detect the contrast signature between the aircraft and background. We conducted computational fluid dynamics simulations for the convective coefficient, and heat transfer simulations were performed considering convection, conduction, and radiation for flight conditions. Thus, we obtained the surface temperature distribution of the aircraft and analyzed the aircraft infrared signature based on the flow characteristics around it. Furthermore, the optimum emissivity for the minimum infrared signature was derived, and the effect of the infrared signature was analyzed when this optimum emissivity was applied to the fuselage surface for each flight condition.

Comparative Study of the Effects of Conventional Cooking and Oven Cooking on the Acceptability of the School Lunch Menu (오븐조리 및 전통조리 방법을 활용한 급식 메뉴의 기호도 비교 연구)

  • Ahn, Hee-Jun;Kim, Hee-Sup
    • Journal of the Korean Society of Food Culture
    • /
    • v.24 no.5
    • /
    • pp.533-539
    • /
    • 2009
  • Frying is the most popular cooking style used in food service institutions in Korea because fried dishes are well accepted by students. However, trans fat contents reduction have recently been required in many foods for health reasons Therefore, alternatives to frying such as oven baking or roasting are being used in many institutions. Steam convection ovens provide dry heat as well as steam so that they can be used to make a wide variety of Korean dishes. In this study, a menu acceptance test was conducted over 2 weeks. Pork, chicken, fish and potato dishes cooked by conventional cooking methods were served for 4 successive days, after which the same dishes were prepared using the oven. Overall, 322 junior high school students evaluated the traditionally cooked foods, while 316 evaluated the oven cooked foods. Comparison of the foods prepared using both methods only revealed a significant difference in the acceptability of foods on the fish menu (p<0.05). Specifically, the acceptance of fried fish was higher than that of the oven baked fish. Additionally, overall acceptance of the menu by males was higher than the acceptance by girls. Furthermore, students who had the preference for special ingredients showed a higher menu acceptance for the menu cooked with those ingredients. On average, approximately 25% of the meal was not consumed and left as plate waste. The portion of the fried fish not consumed was smaller than that of the oven cooked fish, but the portion not consumed did not vary based on cooking method for any other foods evaluated. Overall, it is expected that the oven cooking method will be a good substitute for frying or other cooking method for traditional Korean dishes.

Numerical Investigation of Urea Freezing and Melting Characteristics Using Coolant Heater (냉각수 순환 가열 방식을 이용한 요소수의 동결 및 해동 특성에 관한 수치적 연구)

  • Lee, Seung Yeop;Kim, Nam Il;Park, Yun Beom;Kim, Man Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.8
    • /
    • pp.717-724
    • /
    • 2013
  • Urea-SCR technology is known as one of the powerful NOx reduction systems for vehicles as well as stationary applications. For its consistent and reliable operation in vehicle applications, however, the freezing and melting of the urea solution in cold environments have to be resolved. In this study, therefore, a numerical study of three-dimensional unsteady problems was analyzed to understand the urea freezing and heating phenomena and heat transfer characteristics in terms of urea liquid volume fraction, temperature profiles, and phase change behavior in urea solutions with time by using the commercial software Fluent 6.3. As a result, it was found that the freezing phenomenon proceeds with a phase change from the tank wall to the center, whereas the melting phenomenon occurs faster in the upper part of the storage tank by natural convection and in the adjacent part of the coolant pipe than in other parts. Furthermore, approximately 190 s were required to obtain 1L of urea solution using a 4-coiled coolant heater under conditions of $70^{\circ}C$ and 200 L/h.

Effect of Process Gas and Burner Gas Temperature on Reaction and Thermal Deformation Characteristics in a Steam Reformer (증기 개질기의 반응 및 열변형 특성에 미치는 공정가스와 버너가스 온도의 영향)

  • Han, Jun Hee;Kim, Ji Yoon;Lee, Jung Hee;Lee, Seong Hyuk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.126-132
    • /
    • 2016
  • This study numerically investigates the characteristics of chemical reactions and thermal deformation in a steam reformer. These phenomena are significantly affected by the high-temperature burner gas and the process gas conditions. Because the high temperature of the burner gas ranges from 800 to 1000 K, the reformer tubes undergo substantial thermal deformation, eventually resulting in structural failure. Thus, it is necessary to understand the characteristics of the reaction and thermal deformation under the operating conditions to evaluate the reformer tubes for sustainable, stable operation. Extensive numerical simulations were carried out using commercial CFD code (ANSYS FLUENT/MECHANICA Ver. 13.0) while considering three-dimensional turbulent flows and combined heat transfer including conduction, convection, and radiation. Structural analysis considering conjugated heat transfer between solid tubes and fluid flows was conducted using the Fluid-Solid Interaction (FSI) method. The results show that when the injection temperature of the process gas and burner gas decreased, the hydrogen production rate decreased significantly, and thermal deformation decreased by at least 15 to 20%.