• Title/Summary/Keyword: Heat and Mass Flux

Search Result 449, Processing Time 0.02 seconds

Condensation Heat Transfer for Pure HFC Refrigerants and a Ternary Refrigerant Mixture Inside a Horizontal Tube (HFC 순수냉매 및 3성분 혼합냉매의 수평관내 응축열전달)

  • Oh, Jong-Taek;Hihara, Eiji
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.2
    • /
    • pp.233-240
    • /
    • 2000
  • An experimental study of condensation heat transfer was performed for pure refrigerants HFC32, HFCI25, and HFC134a, and a ternary refrigerant mixture of HFC32/125/134a (23/25/52wt%). The heat transfer coefficients were measured inside a horizontal smooth tube 5.8 mm I.D. and 8.0 m long. The refrigerant temperature at inlet was 40 $^{\circ}C$, and the mass flux was varied from 150 to 400 $kg/m^2s$. As for the pure refrigerants, the heat transfer coefficient of HFC32/125/l34a decreased as the quality decreased. In addition, the heat transfer coefficient of HFC32/l25/134a was about 20 % lower than HFC 134a at a low mass flux but showed no reduction at a high mass flux. The heat transfer coefficient of ternary refrigerant mixtures was 30% lower on the average than that of the pure refrigerant.

Effect of Diameter and Length on the Absorption Performance in a Vertical Absorber Tube (수직형 흡수기 성능에 미치는 흡수기 전열관의 직경과 길이의 영향)

  • 서정훈;조금남
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1214-1222
    • /
    • 2001
  • The present study investigated the effect of diameter and length on the absorption performance of a vertical falling film type absorber using $LiBr-H_2$O solution of 60 wt%. The parameters were diameter of absorber (17.2, 23.4, 31.1 mm), length of absorber (771, 1150, 1528 mm), and film Reynolds numbers (50, 70, 90, 110, 130, 150). As the diameter of the absorber was increased, the absorption mass flux, Sherwood number, heat flux, and heat transfer coefficient were increased, in which Sherwood number and heat transfer coefficient were increased up to 13% and 30% respectively. As the length of the absorber was increased, the total absorption rate and heat transfer coefficient were increased by 37% and 35% respectively, while the absorption mass flux was decreased.

  • PDF

An Experimental Study on Flow Boiling Heat Transfer within Horizontal Rectangular Channels with Small Heights (미세 수평 사각 유로에서의 비등 열전달에 대한 실험적 연구)

  • Lee, Sang-Yong;Lee, Han-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.9
    • /
    • pp.1209-1218
    • /
    • 2001
  • The present paper proposes a new correlation for the flow boiling heat transfer coefficients in the low flow rate condition (Re(sub)LF$\leq$200) within horizontal rectangular channels with small gaps (heights). The gap between the upper and the lower plates of each channel ranges from 0.4 to 2mm while the channel width being fixed to 20mm. Refrigerant 113 was used as the test fluid. The mass flux ranges from 50 to 200kg/㎡s and the channel walls were uniformly heated with the heat flux range of 3-15kW/㎡. The quality range covers from 0.19 to 0.76 and the flow pattern is considered to be annular. The measured heat transfer coefficients increase with the mass flux and the local quality; however the effect of the heat flux appears to be minor. At the low mass flux condition, which is more likely with the smaller gap size, the heat transfer is primarily controlled by the liquid film thickness. The proposed F factor for the heat transfer coefficient in the range of Re(sub)LF$\leq$200 well represents the experimental data within the deviation of $\pm$20%. The Kandlikars flow boiling correlation covers the higher flow-rate range(Re(sub)LF>200) within the deviation of $\pm$20%.

Study on Characteristics of Flow Boiling Heat Transfer in Multi channels (수평 다채널 관에서의 유동 비등 열전달 특성에 관한 연구)

  • CHOI, Yong-Seok;LIM, Tae-Woo
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.5
    • /
    • pp.1310-1317
    • /
    • 2015
  • Two-phase flow boiling heat transfer in micro-channels was experimently investigated. The test section consisted of 15 rectangular micro-channels with a depth of 0.45mm, width of 0.20mm. The experiments were performed for heat fluxes ranging from 5.6 to 46.1kW/m2 and mass fluxes from 150 to 450kg/m2s using FC-72 as the working fluid. According to the results, at the low heat flux region, heat transfer coefficient strongly depends on the heat flux, while heat transfer coefficient at the high heat flux region was independent on the heat flux. Four correlations were used to predict the heat transfer coefficient. The measured heat transfer coefficient was compared with four correlations. It was found that Kaew-On and Wongwises's correlation well predicted the measured data, within the MAE of 40.3%.

Evaporation Heat Transfer and Pressure Drop in Micro-Fin Tubes Before and After Tube-Expansion (마이크로핀관의 확관 전후 열전달 및 압력강하 변화 특성에 관한 연구)

  • Hwang, Yun-Uk;Kim, Min-Su
    • 연구논문집
    • /
    • s.34
    • /
    • pp.29-38
    • /
    • 2004
  • The objective of this study is to investigate the pressure drop and heat transfer characteristics of the micro-fin tubes before and after the tube-expansion process. Test tubes are single-grooved micro-fin tubes made of copper with an outer diameter of 9.52 mm before the tube-expansion. The direct heating method is applied in order to make the refrigerant evaporated in the micro-fin tubes. The test ranges of the heat flux, mass flux, and the saturation pressure are 5 to 15kW/$m^2$, 100 to 200 kg/$m^2s$ and 540 to 790 kPa, respectively. The effects of the mass flux, heat flux, and the saturation pressure of the refrigerant on the pressure drop and the heat transfer are presented for the refrigerant R22. In the test conditions of this study, the heat transfer coefficient for the micro-fin tube after the tube-expansion is about 16.5% smaller than that before the tube-expansion because the fin height of micro-fin is reduced and the fin shape becomes flatter. The micro-fin tube after the tube-expansion has about 7.7% greater average pressure drop than that before the tube-expansion process.

  • PDF

Heat Transfer Correlation during Gas-Cooling Process of Carbon Dioxide in a Horizontal Tube

  • Kang Byung-Ha;Choi Yi-Cheol;Kim Suk-Hyun
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.1
    • /
    • pp.19-27
    • /
    • 2006
  • The characteristics of heat transfer and pressure drop have been investigated experimentally during gas-cooling process of carbon dioxide. The results of this study are useful information in the design of a heat exchanger of $CO_2$ refrigerator. The test section consists of 6 series of copper tube, 4.15 and 2.18mm ID, respectively. The inlet temperature, the operating pressure, and the mass flux are varied in the range of $80{\sim}120^{\circ}C,\;{7\sim}10MPa,\;and\;400{\sim}1,900kg/m^2s$, respectively. The heat transfer coefficient of $CO_2$ is affected by temperature, inlet pressure, and mass flux of $CO_2$. At the maximum HTC, the temperature of $CO_2$ nearly accords with the psuedocritical temperature. It is found that the pressure drop is substantially affected by mass flux and inlet pressure of $CO_2$ . The results have been compared with those of previous work. The heat transfer correlation at the gas-cooling process has been also suggested which predicts within the error of 20%.

Condensation Heat Transfer and Pressure Drop of R-134a in the Oblong Shell and Plate Heat Exchanger

  • Park Jae-Hong;Kim Young-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.3
    • /
    • pp.158-167
    • /
    • 2004
  • Condensation heat transfer experiments were conducted with a oblong shell and plate heat exchanger without oil in a refrigerant loop using R-134a. An experimental refrigerant loop has been developed to measure the condensation heat transfer coefficient $h_r$ and frictional pressure drop ${\Delta}p_f$ of R-134a in a vertical oblong shell and plate heat exchanger. Four vertical counter flow channels were formed in the oblong shell and plate heat exchanger by four plates having a corrugated sinusoid shape of a $45^{\circ}$ chevron angle. The effects of the refrigerant mass flux, average heat flux, refrigerant saturation temperature and vapor quality were explored in detail. Similar to the case of a plate heat exchanger, even at a very low Reynolds number, the flow in the oblong shell and plate heat exchanger remains turbulent. The results indicate that the condensation heat transfer coefficients and pressure drops increase with the vapor quality. A rise in the refrigerant mass flux causes an increase in the $h_r\;and\;{\Delta}p_f$. Also, a rise in the average heat flux causes an increase in the $h_r$. But the effect of the average heat flux does not show significant effect on the ${\Delta}p_f$. On the other hand, at a higher saturation temperature, both the $h_r\;and\;{\Delta}p_f$. found to be lower. Based on the present data, the empirical correlations are provided in terms of the Nusselt number and friction factor.

Coupled Heat and Mass Transfer during the Absorption of Water Vapor into LiBr-H2O Liquid Solution Flowing down the Outside of the Horizontal Cylinder (수평원관상의 LiBr-수용액에 수증기가 흡수될때의 열 및 물질전달)

  • Lee, K.S.;Seo, S.C.;Kim, Y.I.;Park, D.K.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.2
    • /
    • pp.140-149
    • /
    • 1988
  • The problem of heat and mass transfer accompanying the absorption of water vapor into LiBr-$H_2O$ liquid solution flowing over the outside of the horizontal cylinder was theoretically studied to understand the absorption process occuring in the absorber of the absorption heat pump. Numerical results are presented for various quantities of interest relating to temperature, concentration, heat flux and mass flux. Also, the effects of mass flowrate, initial average velocity, and the radius of the cylinder were investigated.

  • PDF

Pressure Effects o]n Critical Heat Flux under Low Pressure and Low Flow Conditions

  • Kim, Hong-Chae;Park, Jae-Wook;Baek, Won-Pil;Chang, Soon-Heung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.82-87
    • /
    • 1996
  • To find the effects of pressure on critical heat flux (CHF) for the conditions of low pressures (especially up to 10 bar) and low mass flux (~300 kg/$m^2$s), a series of experiments have been accomplished by using uniformly heated Inconel-625 tube. The experimental ranges are as follows: pressure (from 1.2 to 8 bar). mass velocities (from 100 to 250 kg/$m^2$s) and the inlet subcooling ($\Delta$h$_{i}$ = 350 kJ/kg). According to the experimental data, it is found that the CHF is nearly independent of the pressure and increases with mass flux. From the results of the CHF correlation assessment for this experimental data, we could find somewhat different tendency of CHF behavior from every other CHF prediction correlation and table.ation and table.

  • PDF

Numerical study of direct contact membrane distillation process: Effects of operating parameters on TPC and thermal efficiency

  • Zamaniasl, Mohammadmehdi
    • Membrane and Water Treatment
    • /
    • v.10 no.5
    • /
    • pp.387-394
    • /
    • 2019
  • Membrane distillation (MD) is one of the water treatment processes which involves the momentum, heat and mass transfer through channels and membrane. In this study, CFD modeling has been used to simulate the heat and mass transfer in the direct contact membrane distillation (DCMD). Also, the effect of operating parameters on the water flux is investigated. The result shows a good agreement with the experimental result. Results indicated that, while feed temperature is increasing in the feed side, water flux improves in the permeate side. Since higher velocity leads to the higher mixing and turbulence in the feed channel, water flux rises due to this increase in the feed velocity. Moreover, results revealed that temperature polarization coefficient is rising as flow rate (velocity) increases and it is decreasing while the feed temperature increases. Lastly, the thermal efficiency of direct contact membrane distillation is defined, and results confirm that thermal efficiency improves while feed temperature increases. Also, flow rate increment results in enhancement of thermal efficiency.