• 제목/요약/키워드: Heat absorption rate

검색결과 246건 처리시간 0.023초

직접 접촉식 4단 유동층 열교환기의 압력손실 및 열전달 특성 (The Pressure Drop and Heat Transfer Characteristics of a Direct Contact 4-Stage Fluidized Bed Heat Exchanger)

  • 임동렬;박상일;전광민
    • 대한기계학회논문집
    • /
    • 제16권2호
    • /
    • pp.325-335
    • /
    • 1992
  • In this work, direct contact 4-stage fluidized bed heat exchanger is experimentally studied to develop a new type of heat exchanger which recovers the energy contained in the high temperature waste gas exhausted from the industrial furnaces. A sand is used as a heat transfer medium in this experiment. To determine the optimum operating condition, 11 different perforated plates which have a different free area ratio with different hole diameter are used in the experiment. From the room temperature experiment, the pressure drop which is caused by fluidized bed formation is observed. The high temperature experiment is carried out to seek the optimum operating condition of high heat efficiency at low heat exchanger operation cost. The results of experiment are as following. The pressure drop in the high temperature condition can be predicted from the results of the room temperature experiment. And Nusselt number becomes smaller due to the increased interference between sand particles as Reynolds number increases when the dilute phase fluidized beds are formed in nigh temperature condition. But heat transfer amount through the total sand surface area become larger due to the large resident amount of sand. Considering the heat transfer amount and the heat exchanger operation cost, perforated plates which have either a 30% or 35% of free area ratio with 15mm of hole diameter are best fitted for our goal of this work. The values of .phi. which is a dimensionless number representing the absorption heat amount per unit sand rate are in the range from 0.4 to 0.5, when Reynolds number of waste gas ranges from 25-30 with these perforated plates.

BTMSM/O2 고유량으로 증착된 SiOCH 박막의 2차원 상관관계 분석을 통한 유전특성 연구 (Dielectric Characteristics through 2D-correlation Analysis of SiOCH Thin Film deposited by BTMSM/O2 High Flow Rates)

  • 김민석;황창수;김홍배
    • 한국전기전자재료학회논문지
    • /
    • 제21권6호
    • /
    • pp.544-551
    • /
    • 2008
  • We have studied the dielectric characteristics of low-k interlayer dielectric materials fabricated by PECVD for various precursor's flow rates. BTMSM precursor was introduced with the flow rates from 42 sccm to 60 sccm by 2 sccm step in the constant flow rate of 60 sccm $O_2$. The absorption intensities of Si-O-$CH_x$ bonding group and Si-$CH_x$ bonding group changed synchronously for the variation of precursor flow rate, but the intensity of Si-O-Si(C) responded asynchronously with the $CH_x$ combined bonds. The heat treatment reduced the FTIR absorption intensity of Si-O-$CH_x$ bonding group and Si-$CH_x$ bonding group but increased the intensity of Si-O-Si(C). The nanopore and free space formed by the increasement of caged link mode and cross link mode of Si-O-Si(C) group implied the origin of low-k SiOCH films.

창호일체형 태양열 집열기 (Window Integrated Solar Collectors)

  • 박성배;임성환;박만귀
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.61-65
    • /
    • 2009
  • Window integrated solar collector is to simply install inside of the existing double glass window frame. Double glass window frame is consist of inner glass of Low-E coating and Silver coating, and outer glass of low iron reinforced glass. In order to secure natural lighting in a room, only 50% of window frame is covered with solar collectors. Solar absorption or transmission rate varies seasonally depending on sun angles. Part of inner glass where right behind of the solar plate is covered with silver coating to increase absorption rate of solar plate. The collector is made of a copper serpentine where aluminum fins are soldering. To improve the effect of insulation of inside of the window frame is recommend vacuum. As a result, we are making the 3th sample and will archieve below $F_RU_L=7.5W/m^2^{\circ}C$ that is the account of heat lossed, and above $F_R({\tau}{\alpha})=0.45$.

  • PDF

H2O/LiBr+HO(CH2)3OH계 공냉형 이중효용 흡수식 냉방시스템의 사이클 해석 (Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System Using H2O/LiBr+HO(CH2)3OH)

  • 권오경;문춘근;윤정인
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.272-280
    • /
    • 1999
  • A cycle analysis was achieved to predict the characteristics by comprehensive modeling and simulation of an air-cooled, double-effect absorption system using a new $H_2O/LiBr+HO(CH_2)_3OH$ solution. The simulation results showed that the new working fluid may provide the crystallization limit 8% higher than the conventional $H_2O/LiBr$ solution. With a crystallization margin of 3wt%(weight%), the optimal solution distribution ratio was found in the range of 36 to 40%. Variation of cooling air Inlet temperature has a sensitive effect on the cooling COP and corrosion problem. The simulation of heat exchangers with UA value revealed that the absorber and the evaporator are relatively important for an air-cooled system compared with the condenser and the low temperature generator. The effect of cooling air flow rate, circulation weak solution flow rate and chilled water inlet temperature were also examined. The new working fluid may provide the COP approximately 5% higher than the conventional $H_2O/LiBr$ solution.

삼중효용 LiBr/물 흡수식 냉방기의 사이클 시뮬레이션 (Cycle simulation of a triple effect LiBr/water absorption chiller)

  • 조광운;정시영;정은수
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.79-87
    • /
    • 1998
  • Basic design of a 50USRT(175㎾) triple effect absorption chiller driven by hot gas has been carried out for both parallel and series flow cycles. Parallel flow cycle showed higher COP, however, the temperature in the generator was also higher than that in series flow cycle. Dynamic operation behavior of a parallel flow system at off-design conditions, such as the change in heat transfer medium temperature or the construction change of the system components, has been investigated in detail. It was found that the cooling capacity was seriously decreased by reducing hot gas flow rate and UA-value in the high temperature generator. However, the system COP was improved, because thermal load in the system components was reduced. The COP and the cooling capacity was found to be improved as cooling water temperature decreased or chilled water temperature increased. The optimum ratio of solution distribution could be suggested by considering the COP, the cooling capacity and the highest temperature in the system, which is critical for corrosion.

  • PDF

태양열 보조열원을 이용한 흡수식 시스템의 동적 시뮬레이션에 의한 과도운전 특성 평가 (Dynamic Simulation of Transient Operations of a Solar Power-Assisted Absorption Chiller)

  • 신영기;서정아;우성민
    • 설비공학논문집
    • /
    • 제22권2호
    • /
    • pp.78-85
    • /
    • 2010
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism were modeled. And solar radiation and the solar collector were also modeled along with its control design. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the issues of the excessive circulation flow rate and the mismatch between available solar power and cooling load discourages the use of the single mode, but the dual use of gas and solar power is recommendable in view of controllability and enhanced COP.

병렬식 하이브리드 흡수식 냉온수기 동특성 시뮬레이션 연구 (A Study on Dynamic Simulation of a Hybrid Parallel Absorption Chiller)

  • 신영기;서정아;우성민;김효상
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.630-635
    • /
    • 2008
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism have been modeled. Flow discharge coefficients of the valves and the pumps were optimized for the double-effect mode with solar-heated water circulated. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. And the cases of the double mode with and without the solar energy were compared. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the single mode utilizing the solar energy only is not practical. It is suggested to operate the system in the double mode and the flow rate control system adaptive to variable solar energy input has to be developed.

  • PDF

가야금(伽倻琴) 향판재(響板材)의 개선(改善)에 관(關)한 연구(硏究) (Studies on the Improvements for GAYAKUM Sounding Boards)

  • 홍병화
    • Journal of the Korean Wood Science and Technology
    • /
    • 제18권4호
    • /
    • pp.65-78
    • /
    • 1990
  • For the purpose of Improving the sounding boards for the conventional GAYAKUM, I was making approximately 202 specimens of radial board, 371 specimens of tangential board by cutting along the grain and the part of stem and 31 specimens of the disjointed traditional GAYAKUM made in Paulownia coreana. And it was conducted to measure specific gravity, dynamic Young's modulus, internal friction, resonant frequency, velosity of sound and width of annual ring by the method of the frexural vibration in a free-free bar in the audio frequency range. And it confirmed the juvenile wood by measuring wood fiber length of specimens. It was also conducted to investigate dynamic properties and moisture absorption by various heat-treatment and to test dynamic Young's modulus and internal friction for the disjointed conventional GAYAKUM. The results obtained were summarized as follow: 1. The Juvenile wood is located within about 7 annual rings from the pith in Paulownia coreana. 2. As increased with the specific gravity, the dynamic Young's modulus had more and more increased, but the internal friction had slightly decreased. 3. I think that radial board would be good for sounding board wood. because radial board is higher than tangential board in dynamic Young's mudulus and internal friction is lower than tangential board. 4. The value of mean dynamic Young's modulus on the conventional GAYAKUM, radial board and tangential board of 604 samples is $0.4283\pm0.037(\times10^{11}dyne/cm^2)$, $0.4316\pm(\times10^{11}dyne/cm^2)$ and $0.4234\pm0.112(\times10^{11}dyne/cm^2)$ respectively. The value of the radial board showed little higher than that of conventional GAYAKUM, but It had a similar tendency between conventional GAYAKUM and tangential board. 5. The annual ring width by four aspect is more narrow in north and west than that of others. 6. The values of specific gravity and dynamic Young's modulus in the mature wood showed higher than those of juvenile wood. 7. As the grain angle in the butt wood more increased to bark from pith, the dynamic Young's modulus were low. Then it was not good for sounding board. 8. It appeared that the heat-treatment for sounding board wood had a more effect to do the treatment of hotiron on surface after heat-treatment during 24 hours in $60^{\circ}C$ temperature. 9. As increased with the temperature, the rate of moisture absorption of heat-treatment wood had decreased. In conclusion, I thought that the sounding board wood for GAYAKUM would had the most effect to do the treatment of hotiron on surface after heat-treatment during 24 hours in $60^{\circ}C$ temperature using the radial board of mature wood.

  • PDF

Yb:YCa4O(BO3)3 단결정 성장과 분광 및 열적 특성 연구 (Crystal Growth of Yb:YCa4O(BO3)3 and Investigation of Spectroscopic and Thermal Properties)

  • 김충렬;이현준;유영문
    • 한국세라믹학회지
    • /
    • 제39권8호
    • /
    • pp.795-800
    • /
    • 2002
  • 융액인상법으로 질소분위기 하에서 $Yb^{3+}$ 이온이 20at% 고용된 $Yb:YCa_4O(BO_3)_3$ (Yb:YCOB) 단결정을 이리듐 도가니를 사용하여 성장시켰다. 양질의 단결정을 성장시키기 위한 인상속도와 회전속도는 각각 1.5∼2 mm/h와 10∼20 rpm이었다. 분광물성 측정 결과, 흡수단이 236 nm에 있었으며, 전형적인 $Yb^{3+}$ 이온의 흡수 스펙트럼이 관찰되었다. Yb:YCOB의 열팽창계수는 320∼650 K의 측정범위에서 결정학적 축 a, b 그리고 c에 대해 12.1×$10^{-6}$ /K, 5.9${\times}10^{-6}$/K, 12.9${\times}10^{-6}$이었다. 비열은 330 K에서 0.162 $cal/g{\cdot}K$이었다.

870MW 대향류 보일러에서 최상부층 버너 선택운전에 따른 보일러 효율변화 고찰 (A Study on the boiler efficiency with selecting the uppermost burners in the 870MW opposite wall fired boiler)

  • 우광윤;김수석;박인찬;함영준;이응윤
    • 플랜트 저널
    • /
    • 제13권2호
    • /
    • pp.46-51
    • /
    • 2017
  • 본 연구에서는 정격출력 870MW, 대향류 석탄보일러의 최상부층 버너운전에 따른 보일러 연소상태 변화와 보일러 효율을 측정하였다. 시험방법은 하부와 중간층 버너가 운전중인 상태에서 최상부층 전방버너, 전,후방 버너 동시 운전, 후방 버너 운전으로 구분하여 최상부층 버너 운전에 따른 보일러 효율을 측정하였으며 시험 결과 최상부층 전 후방 버너 동시운전 > 최상부층 전방 버너 > 최상부층 후방 버너 운전의 순으로 보일러 효율이 높게 나타났다. 최상부층 전방과 후방 버너를 동시에 운전할 경우 보일러 노 내 열흡수율 증가 및 대류전열면 좌우 증기온도 편차가 감소되었다. 보일러 열흡수율 개선에 따라 보일러 배기가스손실 감소 및 석탄공급량이 후방버너 운전 대비 8t/h 감소하였으며, 이는 연료비 절감은 물론 온실가스 배출량 감축에도 크게 기여할 것으로 판단된다.

  • PDF