• Title/Summary/Keyword: Heat Storage Tank

Search Result 294, Processing Time 0.036 seconds

혹한기 지역에서의 자연순환형 태양열 시스템 동파방지 (Freeze Protection for Passive Solar Water Heating System in Bitter Cold Areas)

  • 권재욱;김종현;홍희기
    • 한국태양에너지학회 논문집
    • /
    • 제31권5호
    • /
    • pp.41-46
    • /
    • 2011
  • In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.

태양열난방장치 설계를 위한 f-chart 개발 (Development of f-chart for the Design of Solar Heating Systems)

  • 송달순;유성연
    • 대한설비공학회지:설비저널
    • /
    • 제15권3호
    • /
    • pp.292-298
    • /
    • 1986
  • The new f-chart capable of estimating long-term thermal performance of solar space and water heating systems was developed. The system comprise a flat plate solar collector, heat exchanger, storage tank filled with water, auxiliary fuel fired heater, and a house structure. The information obtained from many simulations of solar heating systems has been used to develop this f-chart. Actual hourly meteorological data collected in Seoul, Daejeon, Kwangju and Daegu, Korea from 1979 to 1983 have been utilized in these simulations. The new f-equation is as follows: $$f=1.034Y_{-}0.0968X_{-}0.2235Y^2+0.0043X^2+0.0144Y^3$$. The system performance estimates obtained from the developed f-chart are in close agreement with the results of experiment.

  • PDF

5kW급 고분자전해질 연료전지 시스템 실증연구 (Field study of 5kW class PEMFC system)

  • 이수재;최대현;전희권
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.87.1-87.1
    • /
    • 2011
  • The residential Fuel Cell system has high efficiency of 85% with transferring natural gas to electrical power and heat, directly and it is a friendly environmental new technology in that $CO_2$ emission can reduce 40% compared with conventional power generator and boiler. The residential fuel cell system consists of two main parts which have electrical and hot storage units. The electrical unit contains a fuel processor, a stack, an inverter, a control unit and balance of plant(BOP), and the cogeneration unit has heat exchanger, hot water tank, and auxiliaries. 5kW class fuel process was developed and tested from 2009, it was evaluated for long-term durability and reliability test including with improvement in optimal operation logic. Stack development was crried out through improvement of design and evaluation protocol. Development of system controller was successfully accomplished through strenuous efforts and original control logic was optimized in 5kW class PEMFC system. In addition, we have been focused on development of system process and assembly technology, which bring about excellent improvement of reliability of system. The 5kW class PEMFC system was operated under dynamic conditions for 1,000 hours and it showed a good performance of total efficiency and durability.

  • PDF

9% Ni강의 피로균열진전거동에 관한 연구 (A Study on the Fatigue Crack Growth Behavior of 9% Ni Steels)

  • 심규택;김재훈;이관희;안병욱;김영균
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.167-172
    • /
    • 2008
  • This study is to evaluate the fatigue crack growth characteristics for base metals and welded metal of 9% Ni steels. Since this material has very excellent fracture toughness at low temperature, it has been widely used for inner walls of LNG storage tank. These materials to compare fatigue crack growth (FCG) behaviour are treated with heat by the method of quenching and tempering (QT), and quenching, lamellarizing and tempering (QLT). FCG tests using compact temsion (CT) specimen under stress ratio R=0.1, 0.5, and constant load are carried out. K-increasing tests are conducted by the standard test method described in ASTM E 647. To investigate the effect of welded metal on the crack growth rate, the locations of notch tip were chosen at the center of welded metal and heat affected zone (HAZ). Form the results, FCG rate has almost same tendency according to stress ratio, base and welded metal, the locations of welded metal. FCG rate of welded metal is somewhat faster than base metal. Also scanning electron microscope (SEM) is used to observe the striation of the fractured surface after fatigue crack tests.

  • PDF

축열조용 복합 다층 단열재의 단열 성능 연구 (A Study on the Insulation Performance of Composite Multilayer Insulation by Applciation of Heat Storage Tank)

  • 최규홍;황승식;신동훈;박우성;박대웅;손승길;정태용
    • 에너지공학
    • /
    • 제23권3호
    • /
    • pp.82-87
    • /
    • 2014
  • 적층 단열재(multi-layer insulation, MLI)는 초전도 마그넷과 초전도 전력 케이블과 같은 초전도 응용기기의 냉각에 사용되는 저온유지장치(cryostat)에 외부 열침입을 차단하여 단열성능을 향상시키기 위해 사용된다. 적층 단열재는 인공위성에 사용되는 단열재로 적층단열재를 구성하는 자재의 종류와 적층층수 등에 따라 단열 성능이 변화한다. 본 연구에서는 적층 단열재의 원리를 이용한 축열조용 복합 다층 단열재(composite multilayer insulation, CMI)의 구성 재질 종류를 변경하고 적층 방식을 바꿈으로서 단열 성능이 바뀌는 것을 확인하였다. 실험은 KS C 9805의 방법을 이용하였으며, 복합 다층 단열재의 단열 성능 확인을 위해 동일한 조건의 축열조에 스티로폼을 적용하여 비교하였다. 또한, 실험 결과를 분석하기 위한 방법으로 기존 단열재에 대한 등가 두께를 비교하고 type별 CMI의 열전도율을 구해 비교하였다. 그 결과 복합 다층 단열재의 등가 두께는 스티로폼 보다 작아 동일 두께인 경우 스티로폼 보다 단열성능이 더 우수함을 확인할 수 있었다. 또한, 복합 다층 단열재의 구성 소재 및 적층 방식에 따라 전도, 대류 및 복사와 관련된 값들의 변화가 총괄 열전달계수에 영향을 미치는 것을 확인할 수 있었다.

열성층 온수저장시스템의 효율적 이용에 관한 실험적 연구 (Experimental Study on the Effective Use of Thermally Stratified Hot Water Storage System)

  • 박이동
    • 태양에너지
    • /
    • 제13권2_3호
    • /
    • pp.45-52
    • /
    • 1993
  • 현열저장에서 열성층의 이점을 태양열 주택에 적용해보았다. 성층으로 인하여 에너지 입력의 열이용 효율이 증가되는 효과가 논의되었고, 실험과 시뮤레이션을 통하여 설명되었다. 성층을 촉진시키기 위하여 Distributor를 사용하였으며, 본 실험에서 Q=8 liter/min, ${\Delta}T=40^{\circ}C$일 때, 최대 90%의 열이용 효율을 얻을 수 있었다. 한편 성층을 촉진시키기 위하여 Distributor의 적은 구멍에서 나오는 유동(속도와 압력)이 같게 제작할 수만 있다면 그 이상의 열이용효율도 얻을 수 있음이 입증되었다.

  • PDF

페로니켈슬래그를 혼입한 황토투수블럭 물성에 관한 연구 (A Study on the Properties of Hwangto Permeable Block Using Ferro Nickel Slag)

  • 김순호
    • 한국건축시공학회지
    • /
    • 제22권6호
    • /
    • pp.607-618
    • /
    • 2022
  • 본 연구는 황토와 무기질 결합재의 수화반응을 이용하여 빗물저류조용 황토투수블록을 개발한 연구로서 제조과정의 산업부산물인 고로슬래그 미분말과 페로니켈슬래그 순환자원을 골재로 활용하고 황토투수블럭을 제작하여 물성분석을 하였다. 도심지 내 투수성 포장을 확대하고 공극이 막혀 투수기능 상실을 방지하여 우수유출저감용 빗물관리시설에 사용하기 위한 것으로써 도시지역에서 열섬현상과 도심 집중강우에 따른 도로침수 포장체 파손 등이 대한 방안으로 활용이 가능하다.

소형 수소액화기 설계 및 운전에 관한 연구 (Design and Operation of a Small-Scale Hydrogen Liquefier)

  • 백종훈;강상우;강형묵;나다니엘 갈소;김서영;오인환
    • 한국수소및신에너지학회논문집
    • /
    • 제26권2호
    • /
    • pp.105-113
    • /
    • 2015
  • In order to accelerate hydrogen society in current big renewable energy trend, it is very important that hydrogen can be transported and stored as a fuel in efficient and economical fashion. In this perspective, liquid hydrogen can be considered as one of the most prospective storage methods that can bring early arrival of the hydrogen society by its high gravimetric energy density. In this study, a small-scale hydrogen liquefier has been designed and developed to demonstrate direct hydrogen liquefaction technology. Gifford-McMahon (GM) cryocooler was employed to cool warm hydrogen gas to normal boiling point of hydrogen at 20K. Various cryogenic insulation technologies such as double walled vacuum vessels and multi-layer insulation were used to minimize heat leak from ambient. A liquid nitrogen assisted precooler, two ortho-para hydrogen catalytic converters, and highly efficient heat pipe were adapted to achieve the target liquefaction rate of 1L/hr. The liquefier has successfully demonstrated more than 1L/hr of hydrogen liquefaction. The system also has demonstrated its versatile usage as a very efficient 150L liquid hydrogen storage tank.

공기조화, 냉동 분야의 최근 연구 동향 -2004년 및 2005년 학회지 논문에 대한 종합적 고찰- (Recent Progress in Air Conditioning and Refrigeration Research - A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2004 and 2005 -)

  • 최영돈;강용태;김내현;김만회;박경근;박병윤;박진철;홍희기
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.94-131
    • /
    • 2007
  • A review on the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering in 2004 and 2005 has been done. Focus has been put on current status of research in the aspect of heating, cooling, air-conditioning, ventilation, sanitation and building environment. The conclusions are as follows. (1) Most of fundamental studies on fluid flow were related with heat transportation of facilities. Drop formation and rivulet flow on solid surfaces were interesting topics related with condensation augmentation. Research on micro environment considering flow, heat, humidity was also interesting for comfortable living environment. It can be extended considering biological aspects. Development of fans and blowers of high performance and low noise were continuing topics. Well developed CFD and flow visualization(PIV, PTV and LDV methods) technologies were widely applied for developing facilities and their systems. (2) The research trends of the previous two yews are surveyed as groups of natural convection, forced convection, electronic cooling, heat transfer enhancement, frosting and defrosting, thermal properties, etc. New research topics introduced include natural convection heat transfer enhancement using nanofluid, supercritical cooling performance or oil miscibility of $CO_2$, enthalpy heat exchanger for heat recovery, heat transfer enhancement in a plate heat exchanger using fluid resonance. (3) The literature for the last two years($2004{\sim}2005$) is reviewed in the areas of heat pump, ice and water storage, cycle analysis and reused energy including geothermal, solar and unused energy). The research on cycle analysis and experiments for $CO_2$ was extensively carried out to replace the Ozone depleting and global warming refrigerants such as HFC and HCFC refrigerants. From the year of 2005, the Gas Engine Heat Pump(GHP) has been paid attention from the viewpoint of the gas cooling application. The heat pipe was focused on the performance improvement by the parametric analysis and the heat recovery applications. The storage systems were studied on the performance enhancement of the storage tank and cost analysis for heating and cooling applications. In the area of unused energy, the hybrid systems were extensively introduced and the life cycle cost analysis(LCCA) for the unused energy systems was also intensively carried out. (4) Recent studies of various refrigeration and air-conditioning systems have focused on the system performance and efficiency enhancement. Heat transfer characteristics during evaporation and condensation are investigated for several tube shapes and of alternative refrigerants including carbon dioxide. Efficiency of various compressors and expansion devices are also dealt with for better modeling and, in particular, performance improvement. Thermoelectric module and cooling systems are analyzed theoretically and experimentally. (5) According to the review of recent studies on ventilation systems, an appropriate ventilation systems including machenical and natural are required to satisfied the level of IAQ. Also, an recent studies on air-conditioning and absorption refrigeration systems, it has mainly focused on distribution and dehumidification of indoor air to improve the performance were carried out. (6) Based on a review of recent studies on indoor environment and building service systems, it is noticed that research issues have mainly focused on optimal thermal comfort, improvement of indoor air Quality and many innovative systems such as air-barrier type perimeter-less system with UFAC, radiant floor heating and cooling system and etc. New approaches are highlighted for improving indoor environmental condition as well as minimizing energy consumption, various activities of building control and operation strategy and energy performance analysis for economic evaluation.

열교환기 형상이 축소한 IRWST 내부의 풀핵비등에 미치는 복합적인 영향에 대한 실험적 연구 (Experimental Investigation of the Combined Effects of Heat Exchanger Geometries on Nucleate Pool Boiling Heat Transfer in a Scaled IRWST)

  • Kang, Myeong-Gie;Chun, Moon-Hyun
    • Nuclear Engineering and Technology
    • /
    • 제28권1호
    • /
    • pp.1-16
    • /
    • 1996
  • 축소한 격납용기 내부 핵연료재장전수저장탱크의 안쪽에 설치한 열교환기 튜브의 주요 매개변수들이 풀핵비등 열전달에 미치는 복합적인 영향을 극명하기 위해 튜브 외경, 표면 거칠기, 그리고 튜브 설치 방향에 대한 다양한 조합들을 환용하여 열유속 q'quot;와 과열 온도 차이 $\Delta$T 간의 관계에 대한 총 1,966 개의 실험값을 취득하였다. 이 실험 결과들에 의하면, (1) 표면 거칠기 증가는 수평 및 수직 튜브 모두에 대해 열전달을 향상시키고, (2) 기포 생성에 따른 두가지 열전달 기구인 주변 액체 운동증가에 의한 열전달 향상과 기포층 및 기포 군집 형성에 의한 열전달 감소는 50㎾/$m^2$의 열유속을 경계로 낮은 열유속과 높은 열유속 영 역 에서 서로 다르게 관찰되는데, 이것은 튜브 설치 방향과 표면 거칠기의 크기와 관련이 있으며, (3) 튜브 외경 증가는 수평 및 수직 튜브 모두에 대해 열전달을 감소시키는데, 그 영향정도는 수평보다 수직구조에서 더 크다. 수평 및 수직 튜브들에 대해 열유속 q'quot;와 표면 거칠기 ($\varepsilon$) 및 튜브 외경 (D) 사이의 관계를 결정하는 두 가지 실험식을 개발하였다. 그리고, q'quot;만의 함수로된 풀핵비등 열전달계수( $h_{b}$ 에 대한 간단한 실험식도 부가적으로 개발하였다. 실험식도 부가적으로 개발하였다.'quot;만의 함수로된 풀핵비등 열전달계수($h_{b}$ 에 대한 간단한 실험식도 부가적으로 개발하였다.

  • PDF