• 제목/요약/키워드: Heat Reservoir

검색결과 90건 처리시간 0.02초

가변전열 히이트 파이프의 특성에 관한 연구 (An experimental study on heat transfer characteristics of variable conductance heat pipe)

  • 김주년;이영호;김용모
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제8권1호
    • /
    • pp.4-16
    • /
    • 1984
  • The heat-pipe is characterised by the highly effective thermal conductance. In order to change the thermal conductance, the heat-pipe is connected to a reservior having a space which is filled with non-condensable gas. In normal operation, the vapour of working fluid will tend to pump the non- condensable gas into the reservoir and the gas-vapour interface situates at some point along the condenser section. The thermal conductance is affected by non- condensable gas. It is concluded that the suitable position of interface can be used to control the temperature of condenser section. In this experiment, the evaporating part is connected to the lowest position of heat-pipe. The copper heat-pipe which is filled with Freon-113 or distilled water as working fluid utilized. As results of experimental study, thermal conductance can be increased by the operating pressure which is infulenced by non-condensable gas. A correlative equation between the thermal conductance and the mass of non- condensable gas is also obtained.

  • PDF

숙박업소 건물의 히트펌프 냉난방 시스템 적용을 위한 시뮬레이션 연구 (Study on the Simulation of Heat Pump Heating and Cooling Systems to Resident Building)

  • 최영돈;한성호;조성환;김두성;엄철준
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.65-74
    • /
    • 2008
  • In Korea, air source heat pump system is less efficient than conventional heat source facilities, such as ground source, river water, because the air temperature in winter season is so low that COP of air source heat pump system drops below 3.0. Therefore, the study on the application of heat pump heating and cooling systems is crucial for the efficient popularization of heat pump. In this work, we present the dynamic analysis of energy consumption for the large resident building by heat resistance-capacitance method. The system simulation of water storage air source heat pump is additionally performed by changing of sizes and locations of the hospital building. The computed results show that energy cost of water storage air source heat pump is low, so it is more economical than absorption chiller & heater.

야간 냉각율을 이용한 우포늪의 기온변화 완화효과 평가 (Evaluation of Mitigation Effect of Upo-Swamp on the Air temperature Variation with Nighttime Cooling Rate)

  • 박명희;김해동
    • 한국환경과학회지
    • /
    • 제20권3호
    • /
    • pp.309-319
    • /
    • 2011
  • In this study, we investigated the effects of Upo-swamp upon local thermal environment with nighttime cooling rate. To do this, we set up the AWS(Automatic Weather observation System) over the central part of Upo-swamp on the early October 2007. We conducted the study by comparing the AWS data with another weather data observed by several meteorological observations of the Korea Meteorological Administration located at the vicinity of Upo-swamp for one year. The air temperature of Upo-swamp was higher than that of the surrounding in cold-climate season. But it was opposite in warm-climate season. We confirmed that Upo-swamp roles to mitigate the daily and annual air temperature ranges. And the daily air temperature variation of Upo-swamp lagged behind the land one. This phenomenon represent that the heat reservoir capacity of Upo-swamp is much larger than that of the ground.

고자기장용 자석을 위한 밀폐순환형 냉각장치 (Closed-Loop Cooling System for High Field Mangets)

  • 최연석;김동락;이병섭;양형석
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제8권1호
    • /
    • pp.59-64
    • /
    • 2006
  • A closed-loop cryogenic cooling system for high field magnets is presented. This design is motivated by our recent development of cooling system for 21 tesla Fourier Transform ion Cyclotron Resonance (FT-ICR) superconducting magnets without any replenishment of cryogen. The low temperature superconducting magnets are immersed in a subcooled 1.8 K bath, which is connected hydraulically to the 4.2 K reservoir through a narrow channel. Saturated liquid helium is cooled by Joule-Thomson heat exchanger and flows through the JT valve, isenthalpically dropping its pressure to approximately 1 6 kPa, corresponding saturation temperature of 1.8 K. Helium gas exhausted from pump is now recondensed by two-stage cryocooler located after vapor purify system. The amount of cryogenic Heat loads and required mass flow rate through closed-loop are estimated by a relevant heat transfer analysis, from which dimensions of JT heat exchanger and He II heat exchanger are determined. The detailed design of cryocooler heat exchanger for helium recondensing is performed. The effect of cryogenic loads, especially superfluid heat leak through the gap of weight load relief valve, on the dimensions of cryogenic system is also investigated.

Experimental study for natural gas production from hydrate reservoir by electric heating method

  • Lee Hoseob;Yang Hojoon;Lee Jeonghwan;Sung Wonmo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.695-702
    • /
    • 2003
  • In this study, an experimental apparatus has been designed and set-up to analyse the dissociating phenomena of hydrate in porous rock using electric heating method supplied at downhole. The electric heat injecting experiments have been performed to investigate the heat transfer within the core, the dissociating phenomena of hydrate, and the productivities of dissociated gas and water. These experiments were under constant heat injecting method as well as preheating methods. From the experimental results, it is seen that the hydrates is dissociated along the phase equilibrium curve and dissociation of hydrate is accelerated with heat. The injected heat is consumed for the dissociation and also it is lost together with outflow of the dissociated gas and water. From the investigation of gas producing behavior for various heat injecting methods, as the injected heat is greater, dissociation is accelerated faster at outlet and hence the initial gas production becomes higher. Also, it is shown that the initial gas productivity under the constant heating method is better, however, the energy efficiency is low because of smaller amount of the produced gas comparing to the amount of heat injected. In the experiments of preheating method, it was seen that gas production only initial stage is different with the preheating time, but the producing behaviors of gas production are similar.

  • PDF

낙동강 구미 보의 증기 안개 발생 시의 미기상학적 특성 (Micro-meteorological Characteristics during the Steam Fog over the Gumi Reservoir of Nakdong River)

  • 김해동;조창범;서광수
    • 한국환경과학회지
    • /
    • 제25권3호
    • /
    • pp.405-415
    • /
    • 2016
  • We analyzed the micro-meteorological characteristics during typical steam fog over the Gumi Reservoir of Nakdong river with the field observation data for recent 2 year(1 April 2013~31 March 2015) collected by the national institute of meteorological research, KMA. Steam fog occur when the cold drainage flows over the warm water surface. As the sensible and latent heat from water are provided to the air, the instability of lower atmosphere is increased. The resultant vertical mixing of warm, moist air near water surface and cold air aloft causes the formation of status cloud. The convection strengthened by radiative cooling of the upper part of the stratus causes the fog to propagate downward. Also, the temperature at the lowest atmosphere is increased rapidly and the inversion near surface disappear by these processes when the fog forms. The increase of wind speed is observed because the downward transportation of momentum is caused by vertical mixing.

상온기체 블로우다운 방식을 사용한 유도무기용 유압식 구동장치의 공압부에 대한 모델링 및 시뮬레이션 (Modeling and Simulation of the Pneumatic Part in a Cold Gas Blow-Down Type Hydraulic Actuation System for a Missile)

  • 박희승
    • 드라이브 ㆍ 컨트롤
    • /
    • 제13권3호
    • /
    • pp.1-7
    • /
    • 2016
  • A cold gas blow-down hydraulic actuation system is widely used in missiles that require an actuation system with a fast response time under a limited space with a short operating time and large loads on the actuators. The system consists of a pneumatic part that supplies the regulated high-pressure gas to a reservoir, and a hydraulic part that supplies pressurized hydraulic oil to the actuators by the pressurized gas in the reservoir. This paper proposes a mathematical model to analyze and simulate the pneumatic part of an actuation system that supplies the operating power to the actuators. The mathematical model is based on the ideal gas equation and also considers the models for heat transfer. The model is applied to the pressure vessel and the gas part of the reservoir, and the model for the pneumatic part is established by connecting the two models for the parts. The model is validated through a comparison of the simulation results with the experimental results. The comparison shows that the suggested model could be useful in the design of the pneumatic part of a cold gas blow-down type hydraulic actuation system.

지하수 히트펌프 시스템의 대수층 활용 사레 연구 (Study on the aquifer utilization for a ground water heat pump system)

  • 심병완;이철우
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.32-35
    • /
    • 2006
  • The validation of a groundwater source heat pump system installation site is estimated by bydrogeothermic model ing. The hydraulic characteristics of the aquifer system is evaluated from pumping and recovery tests. In addition, the temperature distribution by the pumping and the injection of groundwater, and water level fluctuations are simulated by numerical modeling. The total cooling and heating load for the building is designed as 120RT(refrigeration ton) and the ground water source heat pump system covers 50RT as a subsidiary system The scenario of heat pump operation is organized as pumping and inject ion of groundwater that is performed for 8 hours per day in cooling mode for 90 days during the summer season The heat transfer by the injected warm water is limited near the inject ion wells in the simulated temperature distribution. The reason is that the given operation time is too short to expect broad thermal diffusion in large volume of the aquifer in the simulation time The simulated groundwater level and temperature distribution can be used as important data to develope an energy effective pumping and injection well system. Also it will be very useful to evaluate the hydraulic capacity of a target groundwater reservoir.

  • PDF

VCHP에서 불응축 가스량이 열전달 성능에 미치는 영향에 관한 실험적 연구 (An Experimental Study on the affect of Non-condensable Gas Quantity on the Heat Transfer Performances in a Variable Conductance Heat Pipe)

  • 박기호;이기우;이욱현;이계중;서정세
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.19-24
    • /
    • 2003
  • This paper is to research the heat transfer characteristic in copper-water variable conductance heat pipes(VCHP) with a non-condensable gas and gas reservoir. The heat transfer characteristics in the VCHP have not yet been studied much researches. VCHP are used in many applications. These applications range from thermal control of components and systems on satellites, to precise temperature calibration duties, conventional electronics temperature control and thermal diodes. The practical use of VCHP is a simple way to control the temperature of satellites. As the quantity of NCG was increased, there was an increase in the saturation vapor temperatures. As the input heat has loaded from 90 W to 110 W, the difference of the evaporator surface is lower than $10^{\circ}C$.

  • PDF

온수의 표면방출에 의한 2차원 비정상 난류 열확산 의 예측 (Prediction of 2-Dimensional Unsteady Thermal Discharge into a Reservoir)

  • 박상우;정명균
    • 대한기계학회논문집
    • /
    • 제7권4호
    • /
    • pp.451-460
    • /
    • 1983
  • Computational four-equation turbulence model is developed and is applied to predict twodimensional unsteady thermal surface discharge into a reservoir. Turbulent stresses and heat fluxes in the momentum and energy equations are determined from transport equations for the turbulent kinetic energy (R), isotropic rate of kinetic energy dissipation (.epsilon.), mean square temperature variance (theta. over bar $^{2}$), and rate of destruction of the temperature variance (.epsilon. $_{\theta}$). Computational results by four-equation model are favorably compared with those obtained by an extended two-equation model. Added advantage of the four-equation model is that it yields quantitative information about the ratio between the velocity time scale and the thermal time scale and more detailed information about turbulent structure. Predicted time scale ratio is within experimental observations by others. Although the mean velocity and temperature fields are similarly predicted by both models, it is found that the four-equation model is preferably candidate for prediction of highly buoyant turbulent flows.