• 제목/요약/키워드: Heat Management Unit

검색결과 48건 처리시간 0.023초

데이터 기반 모델에 의한 강제환기식 육계사 내 기온 변화 예측 (Data-Based Model Approach to Predict Internal Air Temperature in a Mechanically-Ventilated Broiler House)

  • 최락영;채영현;이세연;박진선;홍세운
    • 한국농공학회논문집
    • /
    • 제64권5호
    • /
    • pp.27-39
    • /
    • 2022
  • The smart farm is recognized as a solution for future farmers having positive effects on the sustainability of the poultry industry. Intelligent microclimate control can be a key technology for broiler production which is extremely vulnerable to abnormal indoor air temperatures. Furthermore, better control of indoor microclimate can be achieved by accurate prediction of indoor air temperature. This study developed predictive models for internal air temperature in a mechanically-ventilated broiler house based on the data measured during three rearing periods, which were different in seasonal climate and ventilation operation. Three machine learning models and a mechanistic model based on thermal energy balance were used for the prediction. The results indicated that the all models gave good predictions for 1-minute future air temperature showing the coefficient of determination greater than 0.99 and the root-mean-square-error smaller than 0.306℃. However, for 1-hour future air temperature, only the mechanistic model showed good accuracy with the coefficient of determination of 0.934 and the root-mean-square-error of 0.841℃. Since the mechanistic model was based on the mathematical descriptions of the heat transfer processes that occurred in the broiler house, it showed better prediction performances compared to the black-box machine learning models. Therefore, it was proven to be useful for intelligent microclimate control which would be developed in future studies.

표준석탄화력 발전소 해수온도 상승에 따른 복수기 압력 손실 최소화 방안 (A Study on Minimizing of Condenser Pressure Loss according to the Temperature Rise of the Seawater for Korean Standard Coal-fired Power Plants)

  • 안효열;문승재
    • 플랜트 저널
    • /
    • 제11권2호
    • /
    • pp.45-51
    • /
    • 2015
  • 손실비용을 고려하여 발전소 효율에 큰 영향을 미치는 복수기의 운전 관리 방안을 연구하였다. 2013년 S발전소의 해수온도는 복수기 압력과 뚜렷한 상관관계를 보였으며, 해수온도가 변화함에 따라 복수기 압력은 설계 압력 38.1 mmHg 보다 -1.7~+20 mmHg의 차이로 운전되었다. 제작사에서 제시한 열소비율 보정곡선을 통해 복수기 압력 1 mmHg 증가시 1,2호기 0.0201%, 3,4호기 0.0155%의 효율 손실과 1,2호기 12,830 원/h, 3,4호기 9,832 원/h의 시간당 손실비용이 발생함을 알 수 있었다. 또한 계절별 대응운전, 설비 노후화, 예방정비 시점에 따른 손실비용의 차이를 확인하고 월별 관리범위를 설정하였다. 이를 통해 운전 관리범위 준수, 손실비용을 고려한 정비 계획 수립으로 최소 2.5억원/년(1호기, 40일 정비)의 관리적 손실을 줄일 수 있을 것으로 판단된다.

  • PDF

위성에 탑재된 상변화물질 열제어장치 비행모델의 열진공시험 및 이를 통한 열해석 모델 보정 (Thermal Vacuum Test of the Phase Change Material Thermal Control Unit Loaded on the Satellite Flight Model and Thermal Model Correlation with Test Results)

  • 조연;김택영;서정기;장태성;박홍영
    • 한국항공우주학회지
    • /
    • 제50권10호
    • /
    • pp.729-737
    • /
    • 2022
  • 하반기에 발사 예정인 차세대소형위성2호(NEXTSat-2)에 탑재된 고상-액상 상변화물질 열제어장치(Phase Change Material Thermal Control Unit, PCMTCU)의 비행모델에 대한 위성 차원 열진공시험 결과로부터 융해-응고에 따른 작동과정을 분석하였다. 시험결과 PCM의 상변화는 발열부품의 온도 안정화에 기여함을 확인하였다. 시험에서 계측된 온도변화를 이용하여 타당한 정도의 정확도를 갖도록 PCMTCU의 열해석모델에 대한 보정을 수행하였다. 보정된 열해석모델로써 임무궤도의 정상 작동에 따른 PCMTCU의 주기적 온도변화를 예측하였으며, PCM의 액상분율로써 정량적 기여도를 평가하였다. 향후 임무궤도에서의 비행자료를 수신하여 PCMTCU의 우주 환경 검증을 완료할 예정이다.

결빙 방지를 위한 저전력 갑판이동로 개발 (Development of a Low-power Walk-way for Anti-Icing)

  • 배상은;조수길;이운식
    • 한국산업융합학회 논문집
    • /
    • 제22권3호
    • /
    • pp.353-364
    • /
    • 2019
  • The walk-way means a passage installed on the deck of a ship so that a person can safely move under any circumstances. So, the walk-way has to maintain a temperature of $5^{\circ}C$ or more for anti/de-icing even at an ambient temperature of $-62^{\circ}C$, a temperature in polar region. At present, the walk-way with heating cable is used, but the anti/de-icing effect is insufficient due to low heat transfer efficiency. Also, it has a construction problem due to heavy weight. In this study, an walk-way with a CNT surface heating element is proposed for the high anti/de-icing effect and the heating value per unit volume. The international standard survey, conceptual design, and simulation for the structural safety and the heat transfer are performed for the development of the proposed walk-way. To enhance the performance, the case studies based on the simulation analysis are conducted. Finally, the final prototype, applying the optimum material and thickness (3.2t of SS400) based on the case study results, is fabricated and experimented.

PYROPROCESSING TECHNOLOGY DEVELOPMENT AT KAERI

  • Lee, Han-Soo;Park, Geun-Il;Kang, Kweon-Ho;Hur, Jin-Mok;Kim, Jeong-Guk;Ahn, Do-Hee;Cho, Yung-Zun;Kim, Eung-Ho
    • Nuclear Engineering and Technology
    • /
    • 제43권4호
    • /
    • pp.317-328
    • /
    • 2011
  • Pyroprocessing technology was developed in the beginning for metal fuel treatment in the US in the 1960s. The conventional aqueous process, such as PUREX, is not appropriate for treating metal fuel. Pyroprocessing technology has advantages over the aqueous process: less proliferation risk, treatment of spent fuel with relatively high heat and radioactivity, compact equipment, etc. The addition of an oxide reduction process to the pyroprocessing metal fuel treatment enables handling of oxide spent fuel, which draws a potential option for the management of spent fuel from the PWR. In this context, KAERI has been developing pyroprocessing technology to handle the oxide spent fuel since the 1990s. This paper describes the current status of pyroprocessing technology development at KAERI from the head-end process to the waste treatment. A unit process with various scales has been tested to produce the design data associated with the scale up. A performance test of unit processes integration will be conducted at the PRIDE facility, which will be constructed by early 2012. The PRIDE facility incorporates the unit processes all together in a cell with an Ar environment. The purpose of PRIDE is to test the processes for unit process performance, operability by remote equipment, the integrity of the unit processes, process monitoring, Ar environment system operation, and safeguards related activities. The test of PRIDE will be promising for further pyroprocessing technology development.

고분자전해질형 단위 연료전지의 주요 작동 조건이 공기극 플러딩 현상에 미치는 영향 (Effect of Main Operating Conditions on Cathode Flooding Characteristics in a PEM Unit Fuel Cell)

  • 민경덕;김한상
    • 대한기계학회논문집B
    • /
    • 제30권5호
    • /
    • pp.489-495
    • /
    • 2006
  • Proton exchange membrane (PEM) should be sufficiently hydrated with a careful consideration of heat and water management. Water management has been a critical operation issue for better understanding the operation and optimizing the performance of a PEM fuel cell. The flooding on cathode side resulting from excess water can limit the fuel cell performance. In this study, the visual cell was designed and fabricated fur the visualization of liquid water droplet dynamics related to cathode flooding in flow channels. The experiment was carried out to observe the formation, growth and removal of water droplets using CCD imaging system. Effects of operating conditions such as cell temperature, air flow rate and air relative humidity on cathode flooding characteristics were mainly investigated. Based on this study, we can get the basic insight into flooding phenomena and its two-phase flow nature. It is expected that data obtained can be effectively used fur the setup and validation of two-phase PEM fuel cell models considering cathode flooding.

금속 부품 열처리업체의 최대전력절감장치 동작 특성 및 효과 분석 (Performence Characteristics and Analysis Effect of Maximum Power Saving Device in Metal Parts Heat Treatment Company)

  • 장홍순;한영섭;황익환;서상현
    • 조명전기설비학회논문지
    • /
    • 제28권6호
    • /
    • pp.40-44
    • /
    • 2014
  • In this paper, maximum power is the lowering device using the facility's energy use and peak load electricity through analyzing attitude should like to make it reduce its power base rate. Simulator to manage the demand for power, a maximum electric power base power from electronic watt-hour meters by a device's signal, predictive power, the current power by computing the goal of power for less than Maximum peak power and peak shift, so that you can manage, and peak York, which role you want a cut Metal heat treatment result which analyzes the data, demand for electricity company over the years of analyzing the characteristics of each load, and effects and Reducing power consumption device every month identified seven Sequence control to the load system and successful power control is about showing that the defined goals.

Nuclear waste attributes of near-term deployable small modular reactors

  • Taek K. Kim;L. Boing;B. Dixon
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1100-1107
    • /
    • 2024
  • The nuclear waste attributes of near-term deployable SMRs were assessed using established nuclear waste metrics, which are the DU mass, SNF mass, volume, activity, decay heat, radiotoxicity, and decommissioning LLW volumes. Metrics normalized per unit electricity generation were compared to a reference large PWR. Three SMRs, VOYGR, Natrium, and Xe-100, were selected because they represent a range of reactor and fuel technologies and are active designs deployable by the decade's end. The SMR nuclear waste attributes show both some similarities to the PWR and some significant differences caused by reactor-specific design features. The DU mass is equivalent to or slightly higher than the PWR. Back-end waste attributes for SNF disposition vary, but the differences have a limited impact on long-term repository isolation. SMR designs can vary significantly in SNF volume (and thus heat generation density). However, these differences are amenable to design optimization for handling, storage, transportation, and disposal technologies. Nuclear waste attributes from decommissioning vary depending on design and decommissioning technology choices. Given the analysis results in this study and assuming appropriate waste management system and operational optimization, there appear to be no major challenges to managing SMR nuclear wastes compared to the reference PWR.

배관감육 관리를 위한 고정식 및 탈착식 보온재 설치 경제성 분석 (Economic Analysis of Installing Fixed and Removable Insulation for Pipe Wall Thinning Management)

  • 황경모;윤훈
    • Corrosion Science and Technology
    • /
    • 제15권6호
    • /
    • pp.320-325
    • /
    • 2016
  • To perform ultrasonic testing (UT) thickness measurement of the secondary side piping installed in nuclear power plants, the insulation for preventing heat loss should be removed. The type of insulation can be divided into fixed and removable insulation. Fixed and removable insulation have their own strengths and weaknesses. Removable insulation has been installed in the components susceptible to wall thinning caused by FAC and erosion from Shin-Kori unit 1, which commenced its commercial operation in 2011. In this paper, the number of repeated inspections of components and the number of replacements of fixed insulation were estimated and a more economical way was identified based on the manufacturing and installation costs for fixed and removable insulation.

고정익 항공기 저온 시동 성능의 품질 신뢰성 향상에 관한 실증적 연구 (An Empirical Study on the Quality Reliability of the Start-up performance of the Fixed Wing Aircraft at low temperature)

  • 김대운;정수헌
    • 품질경영학회지
    • /
    • 제46권1호
    • /
    • pp.169-188
    • /
    • 2018
  • Purpose: The purpose of this study is to analyze low-temperature starting performance of the light attacker and to search and improve the aircraft system including battery and Battery Charge and Control Unit(BCCU). Methods: In order to improve the starting up performance of the light attacker at low-temp, various deficiency cause were derived and analyzed using Fault Tree Analysis method. As a result, it was confirmed there were drawbacks in the charging and discharging mechanism of the battery. The inactivation of the battery's electrolyte at low-temp and the premature termination of the battery charge were the main cause. After long error and trial, we improved these problems by improving performance of battery and optimizing the charging algorithm of BCCU. Results: It was confirmed that the problems of starting up failures were solved through the combined performance test of the battery and BCCU, the ground test using the aircraft system and the operation test conducted by Korea Airforce operating unit for 3 months in winter. Conclusion: This study showed that the improvement of quality reliability was achieved and thus the start-up performance issue of the light attacker has been resolved at low temperature. And it is expected that the design methodologies of temperature-affected electrical system of aircraft will contribute to the development of the aircraft industry in the future.