• 제목/요약/키워드: Heat Management Unit

검색결과 48건 처리시간 0.028초

복합발전기 조합별 증분비 곡선 재설정에 관한 연구 (A Study on the Resetting of Incremental Heat Rate Curve of Combined Cycle Unit by Combination)

  • 홍상범;최준호
    • 전기학회논문지
    • /
    • 제68권1호
    • /
    • pp.8-12
    • /
    • 2019
  • Combined Cycle Unit(CC) generates the primary power from the Gas Turbine(GT) and supplies the remaining heat of the GT to the Steam Turbine(ST) to generate the secondary power from the ST. It plays a major role in terms of energy efficiency and Load Frequency Control(LFC). Incremental Heat Rate(IHR) curves of economic dispatch(ED) of CC is applied differently by GT/ST combination. But It is practically difficult because of performance test by all combinations. This paper suggests a reasonable method for estimating IHR curves for partial combinations(1:1~(N-1):1) using IHR curves when operating with GT alone(1:0) and with all(N:1) combinations of CC.

전자부품의 방열방향에 따른 접촉열전도 특성 (Characterization of a Thermal Interface Material with Heat Spreader)

  • 김정균;;이선규
    • 한국정밀공학회지
    • /
    • 제27권1호
    • /
    • pp.91-98
    • /
    • 2010
  • The increasing of power and processing speed and miniaturization of central processor unit (CPU) used in electronics equipment requires better performing thermal management systems. A typical thermal management package consists of thermal interfaces, heat dissipaters, and external cooling systems. There have been a number of experimental techniques and procedures for estimating thermal conductivity of thin, compressible thermal interface material (TIM). The TIM performance is affected by many factors and thus TIM should be evaluated under specified application conditions. In compact packaging of electronic equipment the chip is interfaced with a thin heat spreader. As the package is made thinner, the coupling between heat flow through TIM and that in the heat spreader becomes stronger. Thus, a TIM characterization system for considering the heat spreader effect is proposed and demonstrated in detail in this paper. The TIM test apparatus developed based on ASTM D-5470 standard for thermal interface resistance measurement of high performance TIM, including the precise measurement of changes in in-situ materials thickness. Thermal impedances are measured and compared for different directions of heat dissipation. The measurement of the TIM under the practical conditions can thus be used as the thermal criteria for the TIM selection.

PEMFC의 열관리가 시스템의 성능에 미치는 영향 (The Effect of Thermal Management on the Performance of a Polymer Electrolyte Membrane Fuel Cell System)

  • 이정호;명노성;김동섭
    • 대한기계학회논문집B
    • /
    • 제35권6호
    • /
    • pp.593-601
    • /
    • 2011
  • 다양한 작동 조건에서 고분자 전해질형 연료전지의 성능 변화를 예측하기 위한 해석 프로그램을 구성하여 열관리가 시스템의 성능에 미치는 영향을 해석하였다. 전체 시스템은 연료전지 스택, 공기공급계, 연료공급계, 열 관리계로 구성 되었으며 각 구성부의 설계점을 고려하여 열역학적 모델링을 적용 하였다. 외기온 변화와 냉각 시스템의 성능 변화에 따라 연료전지 스택의 온도 및 출력 변화가 예상되므로 탈설계 해석을 하여 전체 시스템의 성능 변화를 예측하였다.

LED TV 통합검사유닛의 설계 (Design of LED TV Multi Test Unit)

  • 고훈준
    • 디지털융복합연구
    • /
    • 제10권4호
    • /
    • pp.37-43
    • /
    • 2012
  • LED TV 통합검사유닛은 LED BLU의 구동과 동시에 이상 유무 체크, AGING 작업 등 LED BLU를 테스트하기 위한 검사 장비이다. 기존 검사 유닛은 LCD의 종류와 크기에 따라 생산라인에서 검사 유닛을 교체해야 하는 불편한 점이 있어 본 연구에서는 한 가지 LED TV BLU 모델이 아닌 32 ~ 52인치의 다양한 LED TV BLU 모델을 수용할 수 있는 멀티형(통합형) 검사유닛으로 개발한다. 멀티형으로 개발하기 위해서 멀티 LED TV 통합검사유닛의 출력 전류를 80mA ~ 215mA의 범위로 다양한 출력이 되도록 만들고, LED BLU의 상태를 확인 하는 기능, 디밍(밝기 조절)기능 및 장시간 사용 시 열 발생 완화 기능 등을 구현한다. 또한 펌웨어 프로그램을 개발하고 업그레이드 할 수 있도록 하여 새로운 패널에 대해서도 지원할 수 있도록 개발한다.

시스템 히트펌프의 압축기 주파수 및 전자팽창밸브 개도 변화에 따른 과도성능 특성 (Transient Performance of a System Heat Pump with the Variation of Compressor Speed and EEV Openings)

  • 이상혁;최종민
    • 한국지열·수열에너지학회논문집
    • /
    • 제9권3호
    • /
    • pp.11-18
    • /
    • 2013
  • Small and medium-size buildings employ a multi-distributed individual air-conditioning system utilizing package air conditioners instead of centralized cooling systems, which can allow easier building management and maintenance along with a diversification of facility use. Inverter driven system heat pumps have been developed to achieve not only easy distribution control allowing free combination of indoor units with different models and different capacities, but also wide applications to an intelligent air conditioning. In this study, the transient performance of a system heat pump was analysed with the variation of compressor speed and EEV openings. The superheat was selected as a control parameter of the system, because the variation of it was consistent with each indoor unit capacity.

가스 인젝션을 적용한 전기자동차용 히트펌프의 난방성능 특성에 대한 실험적 연구 (An Experimental Study on the Heating Performance Characteristics of a Vapor Injection Heat Pump for Electric Vehicles)

  • 김동우;정종호;김용찬
    • 설비공학논문집
    • /
    • 제26권7호
    • /
    • pp.308-314
    • /
    • 2014
  • A heat pump has been considered as a thermal management unit for electric vehicles, including the heating and cooling of the cabin. However, the heat pump shows performance degradation at low outdoor temperatures or high compressor speeds. In this study, a R-134a heat pump for an electric vehicle was designed to improve system efficiency, by applying vapor injection with an internal heat exchanger. The heating performance characteristics of the vapor injection heat pump were analyzed at various compressor speeds and outdoor temperatures. The vapor injection heat pump showed 13.3% COP improvement over the non-injection heat pump, when the heating capacity was fixed at 5.2 kW. In addition, the heating capacity of the vapor injection system increased by 9.6%, as compared to the non-injection system.

판형 열교환기 Full-scale 해석을 위한 1차원 유동 네트워크 모델 및 ε-NTU 모델의 수치적 연구 (NUMERICAL STUDY FOR THE FULL-SCALE ANALYSIS OF PLATE-TYPE HEAT EXCHANGER USING ONE-DIMENSIONAL FLOW NETWORK MODEL and ε-NTU METHOD)

  • 김민성;민준기;하만영
    • 한국전산유체공학회지
    • /
    • 제19권1호
    • /
    • pp.47-56
    • /
    • 2014
  • Since a typical plate heat exchanger is made up of a huge number of unitary cells, it may be impossible to predict the aero-thermal performance of the full scale heat exchanger through three-dimensional numerical simulation due to the enormous amount of computing resources and time required. In the present study, a simple flow-network model using the friction factor correlation and a thermal-network model based on the effectiveness-number of transfer units (${\varepsilon}$-NTU) method has been developed. The complicated flow pattern inside the cross-corrugated heat exchanger has been modeled into flow and thermal networks. Using this model, the heat transfer between neighboring streams can be considered, and the pressure drop and the heat transfer rate of full-scale heat exchanger matrix are calculated. In the calculation, the aero-thermal performance of each unitary cell of the heat exchanger matrix was evaluated using correlations of the Fanning friction factor f and the Nusselt number Nu, which were calculated by unitary-cell CFD model.

유기농산물 생산의 특성과 경영소득 분석-충남 홍성군 홍동면 풀무생활협동조합을 중심으로- (An analysis on Production Characteristics and Management Income of Organic Farming in Hong-Dong Myun, Hong-Seong Region, Chung Nam Province)

  • 김호;조완형
    • 한국유기농업학회지
    • /
    • 제4권1호
    • /
    • pp.45-58
    • /
    • 1995
  • This paper studied production characteristics of organic farming products and analyzed management income and production cost of organic farming(rice). In order to analyze these points actually, this study was focused on pruduction activities of a producers' organization, Pulmoo Cooperatives in Hong-Dong Myun, Hong-Seong Region, Chung Nam Province. So the following results were obtained : In 1994, output level and an income rate of rice per unit area(10a) which was produced in organic farming method(O.F.M) was higher than those of general farming method(G.F.M) as about 5%, 7.4%. And management income size of the former was 1.8 times as large as that of the latter. But rice production cost of O.F.M was 1.93 times as much as that of G.F.M, particularily in labor cost and farming equipment cost, light and heat expenses, many other material costs. For the progress of organic farming O.F.M and equipmets should be developed much more, for example, the technics of prevetion against damages by blight and harmful insects and improvement of varieties, natural pesticides, agricultual application of microorganisim, construction of compost heat factory, etc. Since these technics and establishments have taken on the public goods, the development of those should be supported by government.

  • PDF

멀티 코어 프로세서의 온도관리를 위한 방안 연구 및 열-인식 태스크 스케줄링 (Thermal Management for Multi-core Processor and Prototyping Thermal-aware Task Scheduler)

  • 최정환
    • 한국정보과학회논문지:시스템및이론
    • /
    • 제35권7호
    • /
    • pp.354-360
    • /
    • 2008
  • 최신의 마이크로프로세서 설계에서는 전력 관련 문제들이 중요한 고려사항이 되었다. 온-칩(On-chip) 온도 상승은 이와 관련하여 중요한 요소로 부각되었다. 이를 적절하게 처리하지 않을 경우 냉각 비용과 칩 신뢰성에 부정적인 결과를 초래한다. 이 논문에서 우리는 시간적/공간적인 핫 스폿(Hot spot) 완화를 위한 설계들과 열 시간 상수, 작업부하 변동, 마이크로프로세서의 전력 분배 사이의 보편적인 상충관계(Trade off)들을 조사한다. 우리의 방안은 작업부하의 실행위치/순서를 변경하고 동시실행 스레드의 수를 조절하여 시스템의 공간 및 시간적인 열 틈새(Heat slack)에 영향을 줌으로써, 운영체계(OS)와 이미 시스템에 존재하는 하드웨어의 지원만으로 적절한 시간제한내에 작업부하를 조절함으로써 온-칩 온도를 낮출 수 있다.

A hollow definitive obturator fabrication technique for management of partial maxillectomy

  • Patil, Pravinkumar Gajanan;Patil, Smita Pravinkumar
    • The Journal of Advanced Prosthodontics
    • /
    • 제4권4호
    • /
    • pp.248-253
    • /
    • 2012
  • Maxillary obturator prosthesis is the most frequent treatment option for management of partial or total maxillectomy. Heavy weight of the obturators is often a dislocating factor. Hollowing the prosthesis to reduce its weight is the well established fact. The alternate technique to hollow-out the prosthesis has been described in this article which is a variation of previously described processing techniques. A pre-shaped wax-bolus was incorporated inside the flasks during packing of the heat-polymerized acrylic resin to automatically create the hollow space. The processing technique described is a single step flasking procedure to construct a closed-hollow-obturator prosthesis as a single unit. To best understand the technique, this article describes management of a patient who had undergone partial maxillectomy secondary to squamous cell carcinoma rehabilitated with a hollow-obturator prosthesis.