• Title/Summary/Keyword: Heat Loss

Search Result 2,093, Processing Time 0.029 seconds

A Numerical Study of Opposed Nonpremixed Tubular Flames with Radiative Heat Loss (복사열손실이 있는 비예혼합 튜브형 화염에 관한 수치 해석적 연구)

  • Bak, Hyun Su;Yoo, Chun Sang
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.247-250
    • /
    • 2015
  • The characteristics of opposed nonpremixed tubular flames with radiation heat loss are investigated using linear stability analysis and 2-D numerical simulations. Two extinction limits, as the $Damk{\ddot{o}}hler$ number is small or large, are confirmed using finite difference method with a simple continuation method. It is verified that the results of linear stability analysis predict the number of flame cells and the critical Da starting cellular instability or amplification of temperature near both extinction limits with good resolution.

  • PDF

A Study on the Properties of Low-Heat Cement Concrete (저발열시멘트 콘크리트의 기초적 성질에 대한 연구)

  • 문한영;김성수;신화철;강석화
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.57-60
    • /
    • 1997
  • The properties of Low-heat cement are especially in lower heat of hydration than that of other types of cement. In other respect, Low-heat concrete is more advantageous than OPC concrete in chemical resistance, long term age compressive strength, slump loss and resistance to seawater. This paper deals with 28 days age compressive strength and slump loss by elapsed time of mortar and concrete that made with Low-heat cement and 3 types of other cement.

  • PDF

Heat Transfer from each surface for a 3-D Thermally Asymmetric Rectangular Fin

  • Kang, Hyung Suk
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.4 no.2
    • /
    • pp.153-163
    • /
    • 2000
  • The non-dimensional convective heat losses from each surface are investigated as a function of the non-dimensional fin length, width and the ratio of upper surface Biot number to bottom surface Biot number (Bi2/Bi1) using the three-dimensional separation of variables method. Heat loss ratio in view of each surface with the variation of Bi2/Bi1 is presented. The variation of the non-dimensioal temperare profile along the fin center line for a thermally asymmetric conditions is also presented.

  • PDF

Comparison of Insulated Fin Tip and Non-insulated Fin Tip for a Rectangular Fin (사각 핀의 절연된 핀 끝과 비 절연 핀 끝의 비교)

  • Kang, Hyung-Suk
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2414-2419
    • /
    • 2007
  • A rectangular fin with variable fin height, fin length and surrounding temperature is analyzed using a one-dimensional analytical method. Both the heat loss from a rectangular fin with non-insulated fin tip and that with insulated fin tip are presented as a function of the fin height, fin tip length and the convection characteristic number. The relative error in the heat loss of these two cases is also given as a function of the same variables. One of the results shows that the trend of heat loss for both cases with the variation of given variables is similar even though the relative error increases as the shape of the fin becomes shorter and fatter.

  • PDF

A Rectangular Fin Optimization Including Comparison Between 1-D and 2-D Analyses

  • Kang, Hyung-Suk
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.12
    • /
    • pp.2203-2208
    • /
    • 2006
  • Both 1-D and 2-D analytic methods are used for a rectangular fin optimization. Optimum heat loss is taken as 98% of the maximum heat loss. Temperature profile using 2-D analytic method and relative error of temperature along the fin length between 1-D and 2-D analytic methods are presented. Increasing rate of the optimum heat loss with the variation of Biot number and decreasing rate of that with the variation of the fin base length are listed. Optimum fin tip length using 2-D analytic method and relative error of that between 1-D and 2-D analytic methods are presented as a function of Biot numbers ratio.

ANALYSIS OF A REVERSED TRAPEZOIDAL FIN USING A 2-D ANALYTIC METHOD

  • Kang, H.S.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.14 no.3
    • /
    • pp.151-161
    • /
    • 2010
  • A reversed trapezoidal fin is analyzed using a two-dimensional analytical method. Heat loss from the reversed trapezoidal fin is presented as a function of the fin shape factor, fin base thickness and the fin base height. The relationship between the fin tip length and the convection characteristic number as well as that between the fin tip length and the fin base height for equal amounts of heat loss are analyzed. Also the relationship between the fin base thickness and the fin shape factor for equal amount of heat loss is presented. One of the results shows that the heat loss decreases linearly with the increase of the fin shape factor.

Analysis and Optimization based on the Fixed Fin Base Height for a Triangular Fin (삼각 핀의 해석과 고정된 핀 바닥 높이에 기준한 최적화)

  • Kang, Hyung-Suk
    • New & Renewable Energy
    • /
    • v.3 no.1 s.9
    • /
    • pp.13-19
    • /
    • 2007
  • A triangular fin with variable fin base thickness and base height is analyzed and optimized for the fixed fin base height using a two-dimensional analytical method. At the middle of the fin length, the variation of the temperature along the fin height is listed. The influences of the fin length, base thickness and base height on the heat loss and fin efficiency are analyzed, The optimum heat loss, corresponding optimum efficiency and optimum fin length as a function of the fin base thickness are presented. The optimum heat loss and optimum fin tip length as a function of the convection characteristic number are represented.

  • PDF

ANALYSIS OF HEAT LOSS IN A CONSTANT VOLUME MICRO COMBUSTOR (초소형 정적 연소실의 열손실 분석)

  • Na, Han-Bee;Lee, Dae-Hoon;Kwon, Se-Jin
    • 한국연소학회:학술대회논문집
    • /
    • 2002.11a
    • /
    • pp.231-235
    • /
    • 2002
  • A theoretical and experimental study on the combustion process in a constant volume micro combustor is described. Unlike in a macro scale constant volume combustor, the heat loss to the wall plays a major role in flame propagation in a micro micro combustor. In order to analyze the effect of heat loss on combustion phenomena, pressure transition from ignition was measured. A number of cylindrical micro combustors with different diameter and depth were used for experiment to study the effect of length scales and shape factor. The diameter of combustor ranged from 7.5mm to 22.5 mm and the height of cylinder was from 1mm to 4mm. Initial pressure was also varied for the experiment. The diagnostic methods were severely limited due to the size of the apparatus and uncertainties of certain quantities to be measured in a small-scale environment. An analytical method to derive physical quantities that are essential for performance prediction from the pressure measurements is described.

  • PDF

Theoretical Performance Analysis of a Modified Rectangular Fin (변형된 사각 핀의 이론적 성능해석)

  • 강형석;김영준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.683-690
    • /
    • 2004
  • A modified rectangular fin is analyzed by two-dimensional analytic method and finite difference method. Relative error of heat loss from the modified rectangular fin between analytic method and finite difference method is presented. Comparisons of fin effectiveness and heat loss between a modified rectangular fin and a plane rectangular fin are made as a function of the non-dimensional fin length and wing height for different positions of wings by using analytic method. The ratio of the incremental rate of heat loss to that of the area of a modified rectangular fin is shown as a function of the wing height. One of the results shows that performance of a modified fin is more improved as the wing approaches the fin root.

Analysis of Ground Heat Loss in Ondol Heating Systems (온돌 난방에서의 지면을 통한 열손실)

  • Cho, Sung-Hwan;Kim, Kwan-Ho
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.7 no.3
    • /
    • pp.160-166
    • /
    • 1978
  • Heat loss to the ground in ondol heating system is analyzed mathematically using conformal mapping and variable transformations, Both two-and three-dimensional systems are analyzed. Heated house is assumed to be rectangular shape. Mean value of heat loss to the ground can be obtained using Figure 2. Effects of thermal parameters to heat loss are discussed. Numerical examples are also given.

  • PDF