• 제목/요약/키워드: Heat Insulator

검색결과 155건 처리시간 0.021초

실리콘 박막에서 이온 질량 도핑에 의해 주입된 인의 전기적 활성화에 관한 연구 (A study on the electrical activation of ion mass doped phosphorous on silicon films)

  • 김진호;주승기;최덕균
    • 전자공학회논문지A
    • /
    • 제32A권1호
    • /
    • pp.179-184
    • /
    • 1995
  • Phosphorous was deped in silicon thin films by Ion Mass Doping and Changes in the electrical resistance with respect tko heat treatments were investigated. SOI(Silicon On Insulator) thin films which contain few grain boundaries prepared by ZMR(Zone Melting Recrystallization) of polysilicon films, polysilicon films which have about 1500 $A^{\rarw}$ of grain size prepared by LPCVD at 625.deg. C, and amorphous silicon thin films prepared by LPCVD at low temperature were used as substrates and thermal behavior of phosphorous after RTA(Rapid Thermal Annealing) and furnace annealing was carefully studied. Amorphous thin films showed about 10$^{6}$ .OMEGA./ㅁbefore any heat treatment, while polycrystalline and SOI films about 10$^{3}$.OMEGA./¤. All these films, however, showed about 10.OMEGA./ㅁafter furnace annealing at 700.deg. C for 3hrs and RTA showed about the same trend. Films with grain boundaries showed a certain range of heat treatment which rendered increase of the electrical resistance upon annealing, which could not be observed in amorphous films and segregation of doped phosphorous by diffusion with annealing was thought to be responsible for this abnormal behavior.

  • PDF

SOI소자 제죠를 위한 ZMR공정의 모델링 (Modelling of ZMR process for fabrication of SOI)

  • 왕종회;김도현
    • 한국결정성장학회지
    • /
    • 제5권2호
    • /
    • pp.100-108
    • /
    • 1995
  • SOI구조를 얻기 위한 방법의 한가지인 ZMR공정에 있어서 열전달은 계면의 위치와 모양을 결정하는 중요한 역할을 한다. 본 연구에서는 SOI구조를 얻기 위한 ZMR공정중의 열전달 공정을 모사할 수 있는 의사정상상태 2차원 ZMR모델을 수립하였다. 본 모델은 복사, 전도 그리고 대류 열전달을 포함하며, 고/액 계면의 위치를 결정한다. 모델로부터 구한 수치해는 실리콘 기판의 용융부에서의 유동장, 전체 SOR구조에서의 온도장 그리고 실리콘 박막과 기판에서의 고/액 계면의 위치를 포함한다. 여러 공정 변수들의 변화에 따른 온도장과 계면의 형상과 폭의 변화를 알아보았다.

  • PDF

고체 로켓 추진기관에서 실리카/페놀릭 열반응 해석 연구 (Numerical Analysis for Thermal Response of Silica Phenolic in Solid Rocket Motor)

  • 서상규;함희철;강윤구
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.521-528
    • /
    • 2017
  • 본 논문에서는 고체 로켓 추진기관에서 내열재 및 단열재로 사용되는 실리카/페놀릭 복합재료의 열 반응을 고려한 열전도 수치해석을 수행하였다. 고체 로켓 추진기관의 연소 중 실리카/페놀릭의 삭마와 열분해 과정을 고려한 열전도 해석을 위해 1차원 유한차분법을 이용하여 계산을 수행하였다. 노즐벽에서의 경계조건은 대류열전달계수를 고려하였으며, 이는 적분방정식을 이용하여 계산하였다. 삭마두께 및 숯깊이 해석결과는 목삽입재 평가 모터인 TPEM-10을 이용한 시험결과와 비교분석하였으며, 잘 일치하는 것을 확인할 수 있었다.

  • PDF

유전가열에 의한 FRP의 인발성형 연구 (Study on Pultrusion of FRP by Dielectric Heating)

  • 박효열;강동필;안명상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 하계학술대회 논문집 Vol.5 No.1
    • /
    • pp.445-448
    • /
    • 2004
  • Radio frequency and microwave dielectric heating are well-known electroheating methods, used in industrial applications where non electrically conducting materials are to be heated, dried or otherwise processed. The major reason for considering this technique for any process is based on its unique ability to transfer heat into the volume of an electrically non conducting material such as insulator directly, rather than, via a surface. Conventional heating must first bring heat to the product surface and there after it depends on the physical characteristics and condition of the material as to how effectively this heat is transmitted into the mass. The product would suffer surface damage before the main body is adequately processed. Dielectric heating is applied to enhance conventional heating methods and to drastically shorten the required processing duration. Although the use of dielectric heating has been a well proven technique for several years in some industries, its application in the preheating of FRP has been limited by the insufficient experience. In this paper a method is described for uniform radio frequency heating of preheating of FRP.

  • PDF

열수송관에 연결된 에어벤트에 적용 가능한 부식 방지 방안 (Corrosion Protective Method Applicable to Air Vent Connected with a Heat Transport Pipe)

  • 송민지;최가현;김우철;이수열
    • Corrosion Science and Technology
    • /
    • 제22권2호
    • /
    • pp.115-122
    • /
    • 2023
  • This study aimed to elucidate causes of corrosion of heat transport pipes and air vents installed under a manhole of heat transport facilities and suggest effective anticorrosive measures by applying paints or adhesive tapes. It was found that air vent corrosion was attributed to corrosion under insulation caused by the inflow of water and the enrichment of chloride ions. The infiltrated water caused a hydrolysis of polyurethane foam (PUF) insulation by concentrating chloride ions at the interface between a pipe and the PUF. As insulator deteriorated, more chloride ions were eluted as confirmed by ion chromatograph (IC) analysis. As an effective method to prevent air vent corrosion, different types of paints and adhesive tapes with higher corrosion resistance on chloride ions were applied and environmental resistance tests were performed with those samples. Based on environmental test results of samples exposed to 10% HCl solution, it was revealed that a wax tape was the most adequate from a viewpoint of stability at operating condition, environmental resistance, surface treatment, and field applicability.

임계온도스위치를 이용한 저전력 단독경보형 정온식 감지기 개발 (Development of a Low-Power Standalone Heat Detector Using a Critical-Temperature Switch)

  • 조성우;정순규;손지민;김현탁
    • 한국화재소방학회논문지
    • /
    • 제33권4호
    • /
    • pp.70-76
    • /
    • 2019
  • 본 연구에서는 임계온도스위치를 이용하여 저전력 단독경보형 정온식 감지기를 개발하였다. 임계온도스위치는 70 ℃에서 저항이 급격하게 감소하는 특성을 나타내는 소자로, 금속-절연체 전이 현상을 이용함으로써 온도 측정에 대한 높은 신뢰성을 보장한다. 또한 임계온도스위치의 금속에서 절연체로 변하는 디지털적인 특성을 이용하여 마이크로컨트롤러 사용 없이 화재를 감지함으로써 단독경보형 정온식 감지기의 소비 전력을 최소화하였다. 시험결과 임계온도스위치를 이용한 단독경보형 정온식 감지기는 소방청 고시 단독경보형 정온식 감지기 시험 조건을 만족했으며, 소비 전력을 측정한 결과 기존 제품 대비 70%의 전력만으로 화재를 감지함을 확인하였다.

다겹보온커튼의 조합에 따른 열성능의 비교 분석 (P=Comparative Analysis of Thermal Performance According to Combines of Multi-layer Insulating Curtain)

  • 진병옥;김형권;유영선;이태석;김영화;오성식;문종필;강금춘
    • 한국기계기술학회지
    • /
    • 제20권6호
    • /
    • pp.763-769
    • /
    • 2018
  • In this research, in order to improve the heat retention of greenhouse, comparative analysis of the heat flux of the marketed multi-later insulating curtain was carried out. Experiments is conducted by fabricating a test apparatus for investigating the heat flux characteristics. The multi-later insulating curtain used for the experiment was compared using the P, N, S, U and T company, which are commercially available, and the heat flux due to temperature difference between the experimental apparatus and the outside was compared and analyzed. When the internal temperature of the experimental result is the maximum temperature $60^{\circ}C$, the heat flux of multi-later insulating curtain is T Co.($73.1W/m^2$) > S Co.($119.5W/m^2$) > U Co.($155W/m^2$) > N Co.($163.1W/m^2$) > P Co.($177.7W/m^2$). The heat flux means the quantity of heat passing through the unit time per unit area, and the higher the numerical value, the higher the quantity of heat passing through the multi-layer insulating curtain. This can be determined that high heat fluxes produce low heat resistance. Further, it has been found that the weight of the insulating curtain is largely unrelated to the heat insulating property, and the heat insulating curtain having a thickness containing a high internal air layer is excellent in the heat insulating property. In the future when manufacturing a heat insulating curtain, It is judged that it is desirable to manufacture a combination of heat insulating materials that contain a high internal air layer content and that can maintain the air layer even for long-term use while minimizing the volume.

밑이 트인 단열수조의 온도제어에 관한 연구 (A study on the Temperature Control of Insulated Open-End Water Vessel)

  • 한승훈;배철오;안병원
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제36권8호
    • /
    • pp.1097-1103
    • /
    • 2012
  • 우리나라의 서남해안은 어류의 양식 어가가 많이 있다. 양식 어가의 양식장은 해수를 유입시켜 순환시키는 기본적인 특성에 기인하는 관계로 약간의 부주의 및 잘못된 설계는 양식어의 폐사에 까지 영향을 끼치며, 또한 어종별로 최적의 서식온도가 존재함이 이미 밝혀져 있으며 이러한 환경을 사계절에 무관하게 유지하기는 극히 힘든 일인 동시에 필수적 과제이다. 이 논문에서는 열의 기본 성질과 열전달 메커니즘에 대하여 연구하였고, 이를 바탕으로 일정한 격리된 공간에 열을 축적하기 위해 샌드위치 판넬 단열재를 이용하여 밑이 트인 단열 수조를 설계 및 제작을 하고 모의실험을 하였다. 이를 바탕으로 무한히 많은 물중에서 일정 구획을 단열재로 단열하고, 밑이 트인 단열 수조에 히터를 장치하여 국부적인 부분만 가열하여 일정온도를 유지하는 것이 가능함을 확인하였다. 또한 마이크로프로세서를 통하여 온도를 검출하기 위한 온도제어기를 제작하였으며, 일정한 온도 값을 유지하기 위한 AC 전력 제어기를 제작하여 히터의 발열량 제어가 가능한 시스템을 구현하였다.

수산물 조미통조림 제품의 진공도별 열침투 특성 (Characteristics of Thermal Permeation of Marine Canned Products with Different Vacuum Conditions)

  • 김동수;류재상;양승용;이근우
    • 한국수산과학회지
    • /
    • 제33권5호
    • /
    • pp.399-402
    • /
    • 2000
  • 일반적인 수산물 통조림의 내용물 속에는 물, 기름 및 조미액즙 등 packing medium이 들어있다. 본 연구에서는 새우, 꽁치 및 굴을 원료로 건조 및 조미 후 packing medium이 없는 새로운 형태의 조미통조림을 제조하고 이들 제품의 진공도별 (15, 30, 45 및 60cmHg) 열침투 특성을 조사할 목적으로 본 연구를 수행하였다. 진공도별 제품의 열침투 속도는 진공도가 높을수록 빠르게 나타났으며 동일시간 살균했을 때 진공도가 높을수록 Fo치가 높게 나타났다. 한편 상법으로 제조된 water pack과 본 시험에서 제조한 조미통조림과의 열침투 속도를 비교했을 때 새우와 꽁치 조미통조림의 경우는 진공도 15cmHg 이상에서는 열침투 속도가 water pack 제품보다는 빠르게 나타났고 굴 제품의 경우는 water pack 제품이 30cmHg 이상에서 열침투 속도가 빠르게 나타났다. 따라서 packing medium이 없는 조미 통조림의 경우 진공도 30cmHg 이상이 되면 기존의 water pack 제품보다 열침투 속도가 빠르다는 사실이 관찰되었다.

  • PDF

간척지 설치 온실의 난방부하 특성 분석 (Analysis of Heating Load Characteristics for Greenhouses Constructed in Reclaimed Lands)

  • 남상운;신현호
    • 한국농공학회논문집
    • /
    • 제59권6호
    • /
    • pp.1-8
    • /
    • 2017
  • The purpose of this study was to provide basic data for development of environmental design technology for greenhouses constructed in reclaimed lands. We analyzed the climatic conditions around seven major reclaimed land areas in Korea, which have a plan to install advanced horticultural complexes. The characteristics of heating load through the thermal environment measurement of the greenhouse in Saemangeum were analyzed. The part to be applied to the environmental design of the greenhouses in reclaimed lands were reviewed. The overall heat transfer coefficient of the experimental greenhouse with the aluminum screen and multi-layer thermal curtain averaged $3.79W/m^2^{\circ}C$. It represents a 44 % heat savings rate compared with plastic greenhouses with a single covering, which was significantly lower than that of the common greenhouses with 2-layer thermal curtains. This is because the experimental greenhouse was installed on reclaimed land and wind was stronger than the inland area. Among the total heating load, the transmission heat loss accounted for 96.4~99.9 %, and the infiltration loss and the ground heat exchange were low. Therefore, it is necessary to take countermeasures to minimize the transmission heat loss for greenhouses constructed in reclaimed lands. As the reclaimed land is located on the seaside, the wind is stronger than the inland area, and the fog is frequent. Especially, Saemangeum area has 2.6 times stronger wind speed and 3.4 times longer fog duration than the inland area. In designing the heating systems for greenhouses in reclaimed lands, it is considered that the maximum heating load should be calculated by applying the wind coefficient larger than the inland area. It is reasonable to estimate the operation cost of the heating system by applying the adjustment factor 10 % larger than the average in calculating the seasonal heating load.