• 제목/요약/키워드: Heat Equation

검색결과 1,390건 처리시간 0.027초

분무 증발을 이용한 칩 냉각 향상에 대한 수치적 연구 (NUMERICAL STUDY OF CHIP COOLING ENHANCEMENT WITH EVAPORATING MIST FLOW)

  • 노상은;김동철;손기헌
    • 한국전산유체공학회지
    • /
    • 제18권2호
    • /
    • pp.9-16
    • /
    • 2013
  • The heat transfer enhancement of heat sink with mist flow is studied numerically by solving the conservation equations for mass, momentum and energy in the continuous and dispersed phases. A Lagrangian method is used for tracing dispersed water droplets in the heat sink and an Eulerian species transport model for air and steam mixture. The continuous and dispersed phases are interacted with the drag and evaporation source terms. The computed results show that addition of evaporating mist droplets enhances the cooling performance of heat sink significantly.

혼합냉매를 사용한 열펌프의 성능해석 (II) (Performance Analysis of a Heat Pump Using Refrigerant Mixtures (II))

  • 김민수;김동섭;원성필;노승탁
    • 설비공학논문집
    • /
    • 제2권3호
    • /
    • pp.218-225
    • /
    • 1990
  • Studies on the performance of a heat pump using non-azeotropic refrigerant mixtures are done. In order to estimate the thermodynamic properties for the selected non-azeotropic refrigerant mixtures including R22/R152a, R22/R142b, R22/R114 and R13B1/R152a, Peng-Robinson equation of state is adopted. The pressure-enthalpy diagram and the temperature-entropy diagram are plotted for each refrigerant mixture. Considerations on the capacity modulation for the heat pump system using refrigerant mixtures are taken into. Results show that when the heating load varies, the possibility for the capacity modulation is found in the heat pump system using a compressor with constant volume flow rate. Under a constant heating capacity condition in the heat pump system, the coefficient of performance increases when the refrigerant mixtures are used. The volume flow rate decreases as the mass fraction of lower boiler increases in this case.

  • PDF

Simulation of Neutral Flow around Plasma Actuator

  • Jung Suk-Young;Ahn Chang-Soo;Hong Seung-Kyu
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2006년도 PARALLEL CFD 2006
    • /
    • pp.306-308
    • /
    • 2006
  • Numerical simulations were carried out of the effects of momentum and heat produced by a plasma actuator on neutral flow. Momentum and heat generated during plasma discharge were modeled as a body force and heat source using results of experiments and DSMC of particle. These force and heat model were inserted into a Navier-Stokes equation and the flow around the plasma actuator could be explored by solving fluid dynamics only. Fluid simulation showed that force produced in DSMC generated a jet flow in the vicinity of the plasma actuator and heat accounted for density change.

  • PDF

지중매설관의 특성이 토양 - 공기 열교환기 성능에 미치는 영향 (Effects of Earth-Tube Characteristics on the Soil-Air Heat Exchanger Performances)

  • 김영복
    • Journal of Biosystems Engineering
    • /
    • 제22권4호
    • /
    • pp.459-468
    • /
    • 1997
  • To optimize the design and operation of a soil- air heat exchanger system, the effects of variables characterizing system design and operation on the performance of the system were analyzed by a theoretical model which included the three-dimensional transient heat conduction equation. The solution of the theoretical model was acquired by a computer program that uses Finite Difference Methods and Gauss-Seidel iteration computation, in which the time discretization scheme was an implicit difference appoximation. The computer program was validated first by comparison of the results for different grid sizes. Air outlet temperature, energy gain, and heat exchange efficiency of the system were analyzed based upon the tube diameter, tube length, tube thickness, and tube thermal diffusivity.

  • PDF

저압 콘덴서의 열원 분포 해석 (Analysis of Heat Source Distribution in Low Voltage Condenser)

  • 김종겸;이동주;김일중;박영진
    • 전기학회논문지
    • /
    • 제59권7호
    • /
    • pp.1242-1247
    • /
    • 2010
  • In this study, the heat source distributions at the end side and the center of the electrode are analyzed to estimate the electrical stress due to the harmonics from the nonlinear loads. The governing equation at the analysis area of low voltage condenser are numerically solved using the finite element software package to analyze the effects of heat source distribution due to the 5th and 7th harmonics, which can exist normally in the distribution network and can be applied to the low voltage condenser. Finally, the heat source distribution from the harmonics is compared and analyzed with the heat source distribution from the fundamental component of the applied voltage.

ANALYSIS OF NON-INTEGER ORDER THERMOELASTIC TEMPERATURE DISTRIBUTION AND THERMAL DEFLECTION OF THIN HOLLOW CIRCULAR DISK UNDER THE AXI-SYMMETRIC HEAT SUPPLY

  • KHAVALE, SATISH G.;GAIKWAD, KISHOR R.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제26권1호
    • /
    • pp.67-75
    • /
    • 2022
  • Analysis of non-integer order thermoelastic temperature distribution and it's thermal deflection of thin hollow circular disk under the axi-symmetric heat supply is investigated. Initially, the disk is kept at zero temperature. For t > 0 the parametric surfaces are thermally insulated and axi-symmetric heat supply on the thickness of the disk. The governing heat conduction equation has been solved by integral transform technique, including Mittag-Leffler function. The results have been computed numerically and illustrated graphically with the help of PTC-Mathcad.

상변화를 수반하는 이상류(二相流)가 흐르는 원관 주위에서의 난류 열전달 (Turbulent Convective Heat Transfer over a Circular Tube Carrying Gas-Liquid Two Phase Flow with Phase Change)

  • 유성연;김유;정명균
    • 대한설비공학회지:설비저널
    • /
    • 제16권1호
    • /
    • pp.74-80
    • /
    • 1987
  • Turbulent convective heat transfer phenomenon which occur around the evaporator section of heat pump were analyzed experimentally. For this purpose a special wind tunnel and a heat pump system were designed and fabricated. Evaporator section was installed perpendicular to air flow direction and part of the evaporator was made of a glass tube for visual observation. The velocity distribution, turbulent intensity and temperature distribution were measured by hot wire technique and thermocouples. An experimental correlation for the convective heat transfer coefficient was obtained and the result is somewhat higher than the value calculated from Hilpert equation. The difference in two equations is believed to be due to the boning effect inside the evaporator tube.

  • PDF

Biot수를 고려한 균일두께의 환상휜에서의 과도열전달에 관한 연구 (A Study on the Transient Heat Transfer in Annular Fin with Uniform Thickness Considering Biot Number)

  • 김광수
    • 대한설비공학회지:설비저널
    • /
    • 제14권2호
    • /
    • pp.138-149
    • /
    • 1985
  • The heat diffusion equation for an annular fin is analyzed using Laplace transformations. The fin has a uniform thickness with its edge heat loss and two temperature profiles at the base such as a step change in temperature or heat flux. To obtain the exact solutions for temperature distribution, this paper can detect the eigenvalues which satisfy the roots of transcendental equations in above two cases during inverse Laplace transformations. The exact solutions for temperature and heat flux are obtained with the infinite Series by dimensionless factors. The solutions are developed for small and large values of times. These series solutions converge rapidly for large values of time, but slowly for small.

  • PDF

Study on dryout heat flux of axial stratified debris bed under top-flooding

  • Wenbin Zou;Lili Tong;Xuewu Cao
    • Nuclear Engineering and Technology
    • /
    • 제56권2호
    • /
    • pp.636-643
    • /
    • 2024
  • The coolability of the debris bed with a simulant of solidified corium is experimentally studied, focusing on the effects of the structure of the axial stratified debris bed on the dryout heat flux (DHF). DHF was obtained for the four structures with different particle sizes for the axial stratified debris bed under top flooding. The experimental results show that the dryout position of the axial stratified debris bed is formed at the stratified interface indicated by the temperature rise, and the DHF of the axial stratified bed is much lower than that of the homogeneous bed packed with the upper small particles. To predict the dryout heat flux of the stratified debris beds, by considering the properties of the mixed area, a one-dimensional dryout heat flux model of the porous medium is derived from a water and vapor momentum equation for porous medium, two-phase permeability modifications, interfacial drag, and the correlation between capillary pressure and liquid saturation and verified with the experimental data. The modified model can give reasonable results under different structures.

내부구속에 의한 수화열 균열의 개선된 평가 방법 (An Advanced Assessment Strategy of Thermal Cracks Induced by Hydration Heat and Internal Restraint)

  • 전세진;최명성;김영진
    • 콘크리트학회논문집
    • /
    • 제18권5호
    • /
    • pp.677-685
    • /
    • 2006
  • 수화열 균열 저감 기법 중 내부구속이 지배적인 구조물에서 단면의 내외부 온도차를 관리하는 방식은 그 활용도가 매우 높다. 그러나 현 국내 기준의 내외부 온도차와 온도균열지수 관계식은 균열 발생 가능성을 과대평가하는 경향이 있다. 본 연구에서는 그러한 평가식이 유도된 배경을 단계별로 추적하여 타당성을 검증해 보았으며, 그 결과 재령에 따른 탄성계수의 변동성이 고려되지 않은 단순한 재료모델을 사용한 경우에 해당됨을 밝혔다. 개선된 재료모델로 증분형태 구성방정식인 hypoelastic 모델을 사용한 결과 온도균열지수가 기존 식보다 증가되었으며, 그 증가량은 다양한 조건들에 의존하는 것으로 나타났다. 본 연구의 분석 결과와 해외사례를 참조하여 평가식의 개선된 형태를 고찰하였으며 또한 평가시 필요한 내외부 온도차를 시공 조건들의 영향을 고려하여 용이하게 추정할 수 있는 식도 제안하였다. 추후 해석 및 실험 자료가 축적되면 구조물과 배합의 주요 특징들을 반영하여 평가식을 세분화하는 것도 바람직하다고 생각된다.