• 제목/요약/키워드: Heat Equation

검색결과 1,390건 처리시간 0.021초

용융형 스프링클러 헤드의 응답시간 지수 및 작동시간에 관한 연구 (A Study on Response Time Index and Operating Time for Fusible Link Sprinkler Head)

  • 이병곤;태순호
    • 한국안전학회지
    • /
    • 제6권4호
    • /
    • pp.34-44
    • /
    • 1991
  • In this study, the general solution of heat balance equation including conductive heat loss were suggested and were determined the constants with the results of experiment in hot tunnel in order to derive the general equation for the response time and to investigate the response time index which represent the characteristics of response of sprinkler head in actual fires. Two types of test were considered, the plunge test, in which the air temperature is represented by a step function, and the ramp test, in which the air temperature increases at a constant rate. As a result, simple equations were derived, which can be predicted the response time for the ramp type fire with the rate of temperature rise and gas velocity, for the plunge type fire with temperature and gas velocity. Also other useful data, such as the effective temperature, time constant, response time index and conduction parameter were obtained.

  • PDF

유한 체적법을 이용한 난류 확산 화염에서의 복사 열전달 계산 (The Calculation of Radiative Heat Transfer from Turbulent Diffusion Flames Using the Finite Volume Method)

  • 김승현;허강열
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 1997년도 추계 학술대회논문집
    • /
    • pp.106-112
    • /
    • 1997
  • The effects of radiative heat transfer are investigated in a turbulent combustion flow field with highly non-adiabatic flames. Turbulent combustion is modeled by the $k-{\varepsilon}-g$ model and a one step irreversible reaction scheme for the combustion chemistry. The radiative trasport equation is solved by the finite volume method considering the radiative transfer from $CO_2,\;H_{2}O$ and soot only. Gray gas is assumed to calculate the radiative properties of $CO_2\;and\;H_2O$. A two-equation soot formation model is applied to predict soot volume faction distribution. All equations are solved in a coupled manner and the numerical results are compared with available experimental data.

  • PDF

동차선형 유한요소와 Fractional Step방법을 이용한 열유동장의 해석 (Analysis of Thermal flow Field Uing Equal Order Linear Finite Element and Fractional Step Method)

  • 최형권;유정열
    • 대한기계학회논문집
    • /
    • 제19권10호
    • /
    • pp.2667-2677
    • /
    • 1995
  • A new numerical algorithm using equal order linear finite element and fractional step method has been developed which is capable of analyzing unsteady fluid flow and heat transfer problems. Streamline Upwind Petrov-Galerkin (SUPG) method is used for the weighted residual formulation of the Navier-Stokes equations. It is shown that fractional step method, in which pressure term is splitted from the momentum equation, reduces computer memory and computing time. In addition, since pressure equation is derived without any approximation procedure unlike in the previously developed SIMPLE algorithm based FEM codes, the present numerical algorithm gives more accurate results than them. The present algorithm has been applied preferentially to the well known bench mark problems associated with steady flow and heat transfer, and proves to be more efficient and accurate.

실리콘 태양전지 모듈의 two-mode failure 모델의 연구 (A Study of Two-Mode Failure Model for Crystalline Si Photovoltaic Module)

  • 최기영;오원욱;강병준;김영도;탁성주;김동환
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 추계학술대회 초록집
    • /
    • pp.62.2-62.2
    • /
    • 2011
  • To guarantee 20-25 years to the lifetime of the PV modules without failure, reliability test of the module is very important. Field-aged test of the outdoor environment is required. However, due to time constraints, accelerated testing is required to predict the lifetime of PV modules and find causes of failure. Failure is caused by many complex phenomena. In this study, we experimented two accelerated tests about corrosion and fatigue, respectively. First, temperature cycling test for fatigue were tested and Coffin-Manson equation was analyzed. Second, damp heat test for corrosion were tested and Eyring equation were analyzed. Finally, using two-mode failure model, we suggest a new lifetime model that analyze the phenomenon by combining two kinds of data.

  • PDF

Heat Transfer Characteristics in a Cylindrical Duct Packed with Solid Spheres

  • Lee, Seung-Hyuk;Kang, Kwan-Gu;Kim, Sung-Chan;Ryou, Hong-Sun;Noh, Dong-Soon
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제13권1호
    • /
    • pp.11-21
    • /
    • 2005
  • The present paper investigates the heat transfer characteristics in a cylinder packed with porous medium of solid spheres for various parameters such as mass flow rate, sphere diameter, length of the porous medium, and gas temperatures. Pressures and temperatures at the inlet and outlet regions were measured by using static pressure gages and R-type thermocouples. The modified relationship based on the Ergun equation is suggested for the estimation of pressure drops. In addition, the useful empirical correlation for thermal efficiency is obtained in the current study. Thermal efficiency is expressed in terms of non-dimensional time, sphere diameter, porosity, and pressure drops. It is also found that the pressure drop through the cylinder becomes larger as the gas temperature does higher at the inlet region, whereas it substantially decreases when the inlet flow rate decreases.

열유속이 있는 난류 원관 유동에의 FLUENT의 2방정식 난류모델의 적용성 판단 (Assessment of two-equation turbulent models in FLUENT for a turbulent heated pipe flow)

  • 문치명;백성구;박승오
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2003년도 추계 학술대회논문집
    • /
    • pp.158-163
    • /
    • 2003
  • This paper assesses the two-equation turbulence models available in a commercial code, FLUENT, for heat transfer in a turbulent heated pipe flow. In case of flow under $Re_D=10,000$, Standard $\kappa-\epsilon$ and Realizable $\kappa-\epsilon$ models overpredict the Nusselt number about $20\%$ compared with the experimental correlation, and RNG $\kappa-\epsilon$ model overpredicts about $30\%$ when the two-layer zonal method is employed. When wall function method is adopted, all $\kappa-\epsilon$ models show better predictions. Standard $\kappa-\omega$ and SST $\kappa-\omega$ models have the dependency on the first grid point ($0.3). As Reynolds number becomes high, the predictions of all $\kappa-\epsilon$ and $\kappa-\omega$ models are in a good agreement with the experimental correlation.

  • PDF

A Development of a Transient Hydrogen Generation Model for Metal-Water Interactions

  • Lee, Jin-Yong;Park, Goon-Cherl;Lee, Byung-Chul
    • Nuclear Engineering and Technology
    • /
    • 제32권6호
    • /
    • pp.549-558
    • /
    • 2000
  • A transient model for hydrogen generation in molten metal-water interactions was developed with separate models for two stages of coarse mixing and stratification. The model selves the mechanistic equations (heat and mass transfer correlation, heat conduction equation and the concentration diffusion equation) of each stage with non-zero boundary conditions. Using this model, numerical simulations were performed for single droplet experiments in the Argonne National Laboratory tests and for FITS tests that simulated dynamic fragmentation and stratification. The calculation results of hydrogen generation showed better agreement to the experiment data than those of previous works. It was found from the analyses that the steam concentration to be reached at the reaction front might be the main constraint to the extent of the metal droplet oxidized. Also, the hydrogen generation rate in the coarse mixing stage was the higher than that in the stratification stage. The particle size was the most important factor in the coarse mixing stage to predict the amount of hydrogen generation.

  • PDF

가공된 층상조직의 구상화 속도의 해석 (Analysis of Rate Equation for Spherodization of Cold Rolled Lamellar Pearlite Structure)

  • 위명용
    • 열처리공학회지
    • /
    • 제4권2호
    • /
    • pp.1-8
    • /
    • 1991
  • The spheroidization of cold rolled lamellar pearlite in annealing at the temperatures between 600 and $700^{\circ}C$ has been studied by quantitative micrography. It was foud that the spheroidization proceeded as two stageh. The first stage was the stage of relieving the stored energy by cold work, the second was the stage of reducing the interface energy between ferrite and cementite. The spheroidization rate combining the spheroidization rate of each stages is described by the following equation : $$d(1/S)/dt=k_3{\cdot}D/_{(1/s)}\{{\sigma}V/_{(1/s)}+k_4{\cdot}{\exp}(-bt)\}$$ Where, S is the total area of the interface between ferrite and cementite per unit volume, D is the diffusion coefficient, ${\sigma}$ is the boundary energy, V is the volume fraction of the cementite, and $k_3$, $k_4$, b are constants.

  • PDF

비정상 열전도 방정식의 수치 해석을 이용한 화재 건물의 안전성 평가 (Safety Assessment of Burned Building using Numerical Calculation of Unsteady Heat Conduction Equation)

  • 태순호;이병곤
    • 한국화재소방학회논문지
    • /
    • 제11권2호
    • /
    • pp.19-24
    • /
    • 1997
  • 화재 모델에서 구한 가스 의 온도를 이용하여 비정상 열전도 방정식의 수치해석을 하면 유한 제어 체적을 계산할 수 있으며 가열 온도와 저감율로 열에 의한 압축 및 휨 강도의 저하값을 계산할 수 있다. 또한 이 방법을 이용하여 콘크리트 구조물(기둥, 보등)의 안전성 평가에 잘 적용할수 있었다.할수 있었다.

  • PDF

Thermodynamic Properties of the Modified Yukawa Potential

  • Okorie, U.S.;Ibekwe, E.E.;Ikot, A.N.;Onyeaju, M.C.;Chukwuocha, E.O.
    • Journal of the Korean Physical Society
    • /
    • 제73권9호
    • /
    • pp.1211-1218
    • /
    • 2018
  • Within the framework of the modified factorization method, we solve the $Schr{\ddot{o}}dinger$ equation with the modified Yukawa potential. The energy spectrum is obtained using the Pekeris approximation scheme for the centrifugal term. The thermodynamic properties, including the vibrational partition function, vibrational mean energy, vibrational mean free energy, vibrational specific heat capacity and vibrational entropy, are calculated. As a special case, we compare our result with that work of Dong [Int. J. Quant. Chem. 107, 366 (2007)] and find good agreement.