• 제목/요약/키워드: Heat Environment

검색결과 2,482건 처리시간 0.028초

가열 전극 통합 채널 공진기의 진공 환경 구동에 의한 열물성 측정의 민감도 향상 (Sensitivity Enhancement for Thermophysical Properties Measurements via the Vacuum Operation of Heater-integrated Fluidic Resonators)

  • 고주희;이정철
    • 센서학회지
    • /
    • 제32권1호
    • /
    • pp.39-43
    • /
    • 2023
  • Microscale thermophysical property measurements of liquids have been developed considering the increasing interest in the thermal management of cooling systems and energy storage/transportation systems. To accurately predict the heat transfer performance, information on the thermal conductivity, heat capacity, and density is required. However, a simultaneous analysis of the thermophysical properties of small-volume liquids has rarely been considered. Recently, we proposed a new methodology to simultaneously analyze the aforementioned three intrinsic properties using heater-integrated fluidic resonators (HFRs) in an atmospheric pressure environment comprising a microchannel, resistive heater/thermometer, and mechanical resonator. Typically, the thermal conductivity and volumetric heat capacity are measured based on a temperature response resulting from heating using a resistive thermometer, and the specific heat capacity can be obtained from the volumetric heat capacity by using a resonance densitometer. In this study, we analyze methods to improve the thermophysical property measurement performance using HFRs, focusing on the effect of the ambience around the sensor. The analytical method is validated using a numerical analysis, whose results agree well with preliminary experimental results. In a vacuum environment, the thermal conductivity measurement performance is enhanced, except for the thermal conductivity range of most gases, and the sensitivity of the specific heat capacity measurement is enhanced owing to an increase in the time constant.

인지온도를 이용한 여름철 폭염 스트레스와 일 사망률 증가와의 관련성 연구: 1991~2005, 서울 (Relationship between Summer Heat Stress (Perceived Temperature) and Daily Excess Mortality in Seoul during 1991~2005)

  • 이대근;변재영;최영진;김규랑
    • 한국대기환경학회지
    • /
    • 제26권3호
    • /
    • pp.253-264
    • /
    • 2010
  • This study investigates the relationship between daily mortality and heat stress in Seoul, using perceived temperatures (PT) derived from a heat budget model. During the summer season, observed PT intensity showed the biggest magnitude of summer heat stress from the middle 10 days of July to the first 10 days of August. The elderly (65 and above) were found to be the most vulnerable to heat stress. The threshold PT, with a significant increase in excess mortality, was $38^{\circ}C$. No time lagged effect was observed with summer heat stress, while a high correlation was observed between anomalies in PT and relative deviation of mortality. A comparison of the heat index and the discomfort index with excess mortality revealed that the discomfort index underestimated excess mortality, whereas the heat index could not appropriately explain the increase in excess mortality correlated with the increase in excess heat. In contrast, PT was found to be the weather element that best represents excess mortality due to heat stress, and is thus expected to serve as a more reliable forecast index of human biometeorology.

설비공학 분야의 최근 연구 동향 : 2010년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2010)

  • 한화택;이대영;김서영;최종민;김수민;권영철;백용규
    • 설비공학논문집
    • /
    • 제23권6호
    • /
    • pp.449-469
    • /
    • 2011
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigerating Engineering during 2010. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) Research trends of thermal and fluid engineering have been surveyed as groups of general thermal and fluid flow, fluid machinery, and new and renewable energy. Various topics were presented in the field of general thermal and fluid flow. Research issues mainly focused on the thermal reliability of axial fan and compressor in the field of fluid machinery. Studies on the design of ground source heat pump systems and solar chemical reactors were executed in the field of new and renewable energy. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics and industrial heat exchangers. Researches on heat transfer characteristics included heat transfer in thermoelectric cooling/power generation systems, combined heat and power systems, carbon nano fluid with PVP, channel filled with metal foam and smoke ventilation in a rescue station of a railroad tunnel. Also the studies on flow boiling of R123/oil mixture in a plain tube bundle and R410A charge amount in an air cooled mini-channel condenser were reported. In the area of industrial heat exchangers, researches on plate heat exchanger, shell and tube heat exchanger, enthalpy exchanger, micro channel PCHE were performed. (3) Refrigeration systems with alternative refrigerants such as hydrocarbons, mixed refrigerants, and CO2 were studied. Performance improvement of refrigeration systems are tried applying various ideas of refrigerant subcooling, dual evaporator with hot gas bypass control and feedforward control. The hybrid solar systems combining the solar collection devices with absorption chillers or compression heat pumps are simulated and studied experimentally as well to improve the understanding and the feasibility for actual applications. (4) Research trend in the field of mechanical building facilities has been found to be mainly focused on field applications rather than performance improvements. Various studies on heating and cooling systems, HVAC facilities, indoor air environments and energy resources were carried to improve the maintenance and management of building service equipments. In the field of heating and cooling systems, papers on a transformer cooling system, a combined heat and power, a slab thermal storage and a heat pump were reported. In the field of HVAC facilities, papers on a cooling load, an ondol and a drying were presented. Also, studies on HVAC systems using unutilized indoor air environments and energy resources such as air curtains, bioviolence, cleanrooms, ventilation, district heating, landfill gas were studied. (5) In the field of architectural environment and energy, studies of various purposes were conducted such as indoor environment, building energy, renewable energy and green building. In particular, renewable energy and building energy-related researches have mainly been studied reflecting the global interest. In addition, many researches which related the domestic green building certification of school building were performed to improve the indoor environment of school.

$25^{\circ}C$환경에서 $18^{\circ}C$환경으로 노출시 보온력이 상이한 의복의 착용이 체온조절 반응에 미치는 영향 (Influences of Wearing Different Thermal Insulated Clothings on Thermoregulatory Responses from $25^{\circ}C$ Environment to 18$^{\circ}C$ Environment)

  • 이종민
    • 한국의류학회지
    • /
    • 제22권7호
    • /
    • pp.826-832
    • /
    • 1998
  • In order to understand the influences of wearing clothings with different thermal insula-tions when men were exposed from $25^{\circ}C$ environment to 18$^{\circ}C$ environment, thermoregulatory responses were measured on 4 healthy female college students. Subjects rested wearing T-shirts, trousers, and socks called LC(total weight 541g) at 25$\pm$1$^{\circ}C$, 50$\pm$5% R.H. and then exposed to the room conditioned in 18$\pm$1$^{\circ}C$, 50$\pm$5$^{\circ}C$ R.H. with LC as it was(LC Type) or with T-shirts, trousers, socks, training wear upper garment, the training wear lower garment called HC (total weight 1368g)(HC Type) for 120 min. The results can be summarized as follows: 1) When subjects were exposed from $25^{\circ}C$ environment to 18$^{\circ}C$ environment, decrease of rectal temperature was significantly smaller in LC Type than in HC Type. 2)Increase of heat production and weight loss had no significant difference between two types of clothing. 3)Internal thermal conductance was higher in HC Type and external thermal conductance was higher in LC Type. Therefore total thermal conductance was higher in LC Type than in HC Type. 4)Decrease of skin temperature was greater in LC Type than in HC Type. 5)Subjects felt colder with LC Type than with HC Type, but did not feel differently in comfort sensation between two types of clothing. It was suggested that less decrease of rectal temperature in LC type inspite of more dry heat loss from body might be ascribed to a shift of blood from the shell area to the core area originating in the vasoconstriction and the lowered internal thermal conductance. In conclu-sion, the importance of the state of internal heat distribution in the homeostasis seemed to be reaffirmed.

  • PDF

고해상도 지표자료를 이용한 도시 열환경 완화효과 가능성에 관한 연구 (Application of High Resolution Land Use Data on the Possibility to Mitigate Urban Thermal Environment)

  • 이귀옥;이현주;이화운
    • 한국환경과학회지
    • /
    • 제18권4호
    • /
    • pp.423-434
    • /
    • 2009
  • In recent years, the urban thermal environment has become worse, such as days on which the temperature goes above $30^{\circ}C$, sultry nights and heat stroke increase, due to the changes in terrestrial cover such as concrete and asphalt and increased anthropogenic heat emission accompanied by artificial structure. The land use type is an important determinant to near-surface air temperature. Due to these reasons we need to understand and improve the urban thermal environment. In this study, the fifth-generation Pennsylvania State University-National Center for Atmospheric Research Mesoscale Model(MMS) was applied to the metropolitan of Daegu area in order to investigate the influence of land cover changes and urban modifications increase of Albedo to the surface energy budget on the simulated near-surface air temperature and wind speed. The single urban category in existing 24-category U.S. Geological survey land cover classification used in MM5 was divided into 6 classes to account for heterogeneity of urban land cover. As a result of the numerical simulation intended for the metropolitan of Daegu assumed the increase of Albedo of roofs, buildings, or roads, the increase of Albedo (Cool scenario)can make decrease radiation effect of surface, so that it caused drops in ambient air temperature from 0.2 to 0.3 on the average during the daylight hours and smaller (or near-zero) decrease during the night. The Sensible heat flux and Wind velocity is decreased. Modeling studies suggest that increased surface albedo in urban area can reduce surface and air temperatures near the ground and affect related meteorological parameters such as winds, surface air temperature and sensible heat flux.

ESG를 위한 반도체 패키지 기술 트렌드 (Technology Trends of Semiconductor Package for ESG )

  • 서민석
    • 마이크로전자및패키징학회지
    • /
    • 제30권3호
    • /
    • pp.35-39
    • /
    • 2023
  • ESG는 많은 기업에게 기업 가치를 향상시키고, 지속 경영이 가능하게 하는 큰 지침이 되고 있다. 그 중에서도 환경(Environment)은 기술적 관점의 접근이 필요하다. 환경 오염을 줄이거나 방지하고, 에너지를 절감하는 것은 기술적인 해법이 필요하기 때문이다. 반도체 패키지 기술은 반도체 패키지의 본연의 역할인 칩의 보호, 전기/기계적 연결, 열 방출 등을 잘 하기 위해 개발 및 발전해 왔는데, 이에 따라 열 방출 효과 향상, 전기적/기계적 특성 향상, 칩을 보호하는 신뢰성 향상, 적층 및 소형화, 그러면서 비용절감을 위한 기술들이 개발되고 발전해 왔다. 그 중에서도 열 방출 기술은 열효율을 높이고, 냉각을 위한 에너지 소모를 작게 하며, 전기적 특성 향상 기술도 저전력 사용과 에너지 소모를 줄이는 효과를 만들어서 환경에도 영향을 주었다. 또한 재사용이나 재료 소모를 줄이는 기술은 환경 오염을 줄이게 되며, 특히 환경에 유해한 물질들에 대해 대체하는 기술들은 환경 개선에 기여하게 된다. 본 논문에서는 이러한 환경 오염 방지 및 개선을 위한 반도체 패키지 기술들의 트렌드를 정리하였다.

Vegetation Canopy의 접지층 환경에 대한 열적 영향 제1부 : 수치실험 (On the Thermal Effect of Vegetation Canopy to the Surface Sublayer Environment Part 1 : Numerical Experiment)

  • 진병화;황수진
    • 한국환경과학회지
    • /
    • 제8권2호
    • /
    • pp.145-150
    • /
    • 1999
  • To estimate the thermal effect of the vegetation canopy on the surface sublayer environment numerically, we used the combined model of Pielke's1) single layer model for vegetation and Deardorff's2) Force restore method(FRM) for soil layer. Application of present combined model to three surface conditions, ie., unsaturated bare soil, saturated bare soil and saturated vegetation canopy, showed followings; The diurnal temperature range of saturated vegetation canopy is only 20K, while saturated bare soil and unsaturated bare soil surface are 30K, 35K, respectively. The maximum temperature of vegetation canopy occurs at noon, about 2 hours earlier than that of the non-vegetation cases. The peak latent heat fluxes of vegetation canopy is simulated as a 600Wm-2 at 1300 LST. They have higher values during afternoon than beforenoon. Furthermore, the energy redistribution ratios to latent heat fluxes also increased in the late afternoon. Therefore, oasis effect driving from the vegetation canopy is reinforced during late afternoon compared with the non-vegetated conditions.

  • PDF

Development of a Human-Clothing-Environment Simulator for Dynamic Heat and Moisture Transfer Properties of Fabrics

  • Kim, Eun Ae;Yoo, Shinjung;Kim, Jeongjin
    • Fibers and Polymers
    • /
    • 제4권4호
    • /
    • pp.215-221
    • /
    • 2003
  • A vertical skin model with two detachable environmental chambers was developed to simulate a Human-Clothing-Environment system and to evaluate heat and moisture transport properties of textile materials under severe conditions and during transient states. The construction of the system was described and data reproducibility and accuracy of the instrument were verified by using PEG treated nonwovens. Also advantages over a traditional static type experiment were demonstrated based on a series of experiments.

Data Analysis of KOMPSAT Thermal Test in Simulated On-orbit Environment

  • Kim, Jeong-Soo;Chang, Young-Keun
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제1권2호
    • /
    • pp.30-42
    • /
    • 2000
  • On-orbit thermal environment test of KOMPSAT was performed in early 1999. An analysis of the test data are addressed in this paper. For the thermal-environmental simulation of spacecraft bus, an artificial heating through the radiator zones and onto some critical heat-dissipating electronic boxes was made by Absorbed-heat Flux Method. Test data obtained in terms of temperature history were reduced into flight heater duty cycles and converted into the total electrical power required for spacecraft thermal control. Verification result of flight heaters dedicated to the bus thermal control is presented. Additionally, an exhaustive heating-control process for maintaining the spacecraft thermally safe and for realistic simulation of the orbital-thermal environment during the test are graphically shown. Qualitative suggestions to post-test model correlation are given in consequency of the analysis.

  • PDF

목질마루바닥재와 벽체용 재료를 이용한 평판열류계법과 MTPS (Modified Transient Plane Source)법의 열전도율 상관관계 분석 (Correlation Analysis of the Thermal Conductivity Heat Flow Meter and MTPS (Modified Transient Plane Source) Method Using Wood Flooring and Wall Materials)

  • 차정훈;서정기;김수민
    • 한국가구학회지
    • /
    • 제22권2호
    • /
    • pp.118-125
    • /
    • 2011
  • These days global warming is the most important problem and the most important factor is high emission of carbon dioxide. The 23% of carbon dioxide emission for building construction must be reduced. Thermal conductivity is the most basic factor that can decrease the energy consumption especially insulation. Therefore, an accurate and continuous thermal conductivity measurement can be a way to save energy. In this paper, there are methods about how to investigate thermal conductivity measurements and comparing two methods which are the Heat Flow Meter 436 and TCi.

  • PDF