• Title/Summary/Keyword: Heat Emission

Search Result 921, Processing Time 0.024 seconds

Thermal Characteristic Evaluation of Functionally Graded Composites for PSZ/Metal

  • Lim, Jae-Kyoo;Song, Jun-Hee
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.298-305
    • /
    • 2000
  • The functionally graded material (FGM) is the new concept for a heat resisting material. FGM consists of ceramics on one side and metal on the other. A composition and microstructure of an intermediate layer change continuously from ceramics to metal at the micron level. This study is carried out to analyze the thermal shock characteristics of functionally graded PSZ/ metal composites. Heat-resistant property was evaluated by gas burner heating test using $C_2H_2/O_2$ combustion flame. The ceramic surface was heated with burner flame and the bottom surface cooled with water flow. Also, the composition profile and the thickness of the graded layer were varied to study the thermo mechanical response. Furthermore, this study carried out the thermal stress analysis to investigate the thermal characteristics by the finite element method. Acoustic emission (AE) monitoring was performed to detect the microfracture process in a thermal shock test.

  • PDF

A Study on the Enviromental Impact of District Heating System (지역난방의 환경개선효과 측정에 관한 연구)

  • Sonn, Yang-Hoon;Park, Joo Heon;Cho, Jun-Hyuk
    • Environmental and Resource Economics Review
    • /
    • v.10 no.3
    • /
    • pp.367-386
    • /
    • 2001
  • In this paper we analyze the environmental advantages of district heating system. We construct three econometric models to analyze the energy consumption and economic cost as well as the emission of the major pollutants like $SO_x$, $NO_x$, DUST, and $CO_2$. As the size of heating supply is larger, the district heating system is evaluated to be better than other heating systems environmentally and costly in the long run. Especially, the district heating reduces $SO_x$ emission significantly when the size of heat production is large. But the advantages of district heating system are very sensitive to the fuel mix and heat source.

  • PDF

A Study on the Infrared Ray Radiator with High Efficiency Emission (고효율 적외선 복사체에 관한 연구)

  • Park, Youn-Joon;SaGong, Geon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.27-30
    • /
    • 2003
  • In order to get the infrared ray radiator with high efficiency emission, the starting raw material $Fe_2O_3$ powder is heat-treated under the oxygen pressure log[$PO_2$] = -13~15 at $800^{\circ}C$ for 2hours. It has shown that the radiation rate was larger than 0.85 at the relatively high temperature($400^{\circ}C$), and decreased slowly with increasing the temperature from 50 to $400^{\circ}C$.

  • PDF

A Study on Friction Welding and AE Evaluation for Cold Die Steel and High Temperature Creep Properties (금형강의 마찰용접과 AE평가 및 고온 크리프 특성에 관한 연구)

  • 황성필;김일석;유인종;이연탁;오세규
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2001.05a
    • /
    • pp.282-288
    • /
    • 2001
  • This paper deals with determining the proper friction welding condition and analyzing various mechanical properties of friction welded joints of the bladepart heat resisting steel(STD11) for cold die punch to the shank part alloy steel(SCM440). And the in-process real-time weld quality evaluation technique by acoustic emission during friction welding of STD11 to SCM440 steels with higher confidence and reliability has been much required even though it might be the first trial approach for developing it. Also, the high temperature properties of STD11-SCM440 weld were considered in this paper.

  • PDF

Effects of Suction Air Humidity on the Combustion and Exhaust Emissions Characteristics in Diesel Engine (디젤기관에 있어서 흡기습도 변화가 연소 특성과 배기배출물 특성에 미치는 영향)

  • 임재근;김동호
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.24 no.4
    • /
    • pp.421-426
    • /
    • 2000
  • A study on the combustion and exhaust emissions characteristics of diesel engine with various suction air humidity is performed experimentally. In this paper, suction air humidity is changed from RH 50% to RH 90%, the experiments are performed at engine speed 1800rpm, and main measured parameters are cylinder pressure, fuel consumption rate, CO, HC, NOx and Soot emissions etc. Increase of suction air humidity from RH 50% to RH 90% does not effect specific fuel consumption, decreases maximum pressure in cylinder, ratio of maximum pressure rise and net heat release, and delays ignition timing. Also, that increases CO and HC emissions, decreases NOx emissions, but does not constant in changing tendency on emission.

  • PDF

A Study on the Effect of Injection Rate on Emission Characteristics in D.I. Diesel Engine by Multi-zone Model (Multi-zone 모델에 의한 디젤엔진에서의 분사율 변화에 따른 배기가스 특성에 관한 연구)

  • ;;;;Liu Shenghua
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.94-103
    • /
    • 1999
  • A model for the prediction of combustion and exhaust emissions of DI diesel engine has been formulated and developed . This model is a quasi-dimensional phenomenological one and is based on multi-zone combustion modelling concept. It takes into consideration, on a zonal basis ,detailed of fuel spray formation, droplet evaporation, air-fuel mixing, spray wall interaction, swirl , heat transfer, self ignition and burning rate . The emission model is considered with chemical equipment , as well as the kinetics of fuel. NO and soot reactions in order to calculate the pollutant concentrations within each zone and the whole of cylinder . The accuracy of prediction versus experimental data and the capability of the model in predicting engine heat release, cylinder pressure and all the major exhaust emissions on zonal and cumulative basis., is demonstrated. Detailed prediction results showing the sensitivity of the model bv various injection rates are presented and discussed.

  • PDF

Structural Characteristics of Multilayer Piezoelectric Transformer According to Designs of Internal Electrode (적층형 압전 변압기의 내부전극에 따른 구조적 특성)

  • 임인호;박종주;정회승;이영희
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.14 no.11
    • /
    • pp.898-903
    • /
    • 2001
  • In this study, we investigated amounts, distributions and sizes of pores of multilayer piezoelectric transformer, and predicted heat emission property and electrical characteristics according to designs of internal electrode. Forming densities of device having MLC, fingered and full filled internal electrode structure were 4.73 g/㎤, 4.80 g/㎤, 4.82 g/㎤ and forming porosities were 17.3737%, 13.1475%, 12.6121%, respectively. And sintered densities of MLC structured, fingered and full filled devices were 7.76 g/㎤, 7.75 g/㎤, 7.84 g/㎤ and sintered porosities were 4.0967%, 2.7132%, 2.5317%, respectively. Therefore, we concluded that fingered and full fi1led internal electrode devices, expecially, fingered internal electrode devices had cost-effective effect and maximum poling effect due to higher sintered density and lower porosity than MLC structured device. Also we can predict that they have an effect on good heat emission and high output properties of multilayer piezoelectric transformer.

  • PDF

Estimation of the Temporal and Spatial Distribution of Anthropogenic Heat in Daegu (대구지역 인공열의 시공간적 분포 추정에 관한 연구)

  • 안지숙;김해동;홍정혜
    • Journal of Environmental Science International
    • /
    • v.11 no.10
    • /
    • pp.1045-1054
    • /
    • 2002
  • Urban atmospheric conditions are usually settled as warmer, drier and dirtier than those of rural counterpart owing to reduction of green space and water space area heat retention in surfaces such as concrete and asphalt, and abundant fuel consumption. The characteristics of urban climate has become generally known as urban heat island. The purpose of this study is to investigate the temporal and spatial distribution of the heat emission from human activity, which is a main factor causing urban heat island. In this study, the anthropogenic heat fluxes emitted from vehicles and constructions are estimated by computational grid mesh which is divided by 1km $\times$ 1km. The anthropogenic heat flux by grid mesh can be applied to a numerical simulation model of the local circulation model. The constructions are classified into 9 energy-consumption types - hospital, hotel, office, department store, commercial store, school, factory, detached house and flat. The vehicles classified into 4 energy-consumption types - car, taxi, truck and bus. The seasonal mean of anthropogenic heat flux around central Daegu exceeded $50 W/m^2$ in winter. The annual mean anthropogenic heat flux exceeded $20 W/m^2$. The values are nearly equivalent to the anthropogenic heat flux in the suburbs of Tokyo, Japan.

An Experimental Study on the Heating Performance of Coolant Heat Source Heat Pump System for Zero Emission Vehicles (무공해 자동차용 수열원 히트펌프 시스템의 난방 성능에 관한 실험적 연구)

  • Lee, Daewoong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.7
    • /
    • pp.57-62
    • /
    • 2014
  • This study presented the feasibility of a coolant heat-source heat pump system as an alternative heating system for electrically driven vehicles. Heat pumps are among the most environmentally friendly and efficient heating technologies in residential buildings. In various countries, electric mobiles devices such as EV, PHEV, and FCEV, have been mainly concerned with heat pumps for new mobile markets. The experiments herein were conducted for various ambient temperatures and coolant temperatures to reflect the winter season. The system, a coolant heat-source heat pump, consisted of an inside heat exchanger, an outside heat exchanger, a motor driven compressor, an electronic expansion valve, and plumbing parts. For the experimental results, the maximum heating capacity and air discharge temperature are up to 6.3 kW and $62^{\circ}C$ respectively at an ambient temperature of $10^{\circ}C$, and coolant at $10^{\circ}C$. However, at $-20^{\circ}C$ ambient temperature and $-10^{\circ}C$ coolant temperature, conditions were insufficient to warm the cabin as the air discharge temperature was $13^{\circ}C$.

Effects of Reburning on Heat Transfer Characteristics and $NO_x$ Reduction (재연소가 열전달 특성과 $NO_x$ 감소에 미치는 영향)

  • Lee, Chang-Yeop;Baek, Seung-Wook
    • Journal of the Korean Society of Combustion
    • /
    • v.10 no.2
    • /
    • pp.18-25
    • /
    • 2005
  • An experimental study has been conducted to evaluate the effects of reburning on $NO_x$ reduction and also to examine heat transfer characteristics from LPG flame. Experiments were performed in flames stabilized by a co-flow swirl burner, which was mounted at the bottom of the furnace. Tests were conducted using LPG gas as main fuel and also as reburn fuel. The effects of reburn fuel fraction and injecting location of reburn fuel are studied. The paper reports data on flue gas emissions, temperature distribution in furnace and various heat fluxes at the wall for a wide range of experimental conditions. In a steady state, the total as well as radiative heat flux from the flame to the wall of furnace has been measured using a heat flux meter. Temperature distribution and emission formation in furnace have been also measured and compared.

  • PDF