• Title/Summary/Keyword: Heat Check

Search Result 197, Processing Time 0.025 seconds

A Literary Review on Needle Retaining Time: Centered on the Chinese Medical Journal (유침(留鍼)시간에 대한 문헌적 고찰: 중국 문헌을 중심으로)

  • Wang, Kai-Hsia;Lee, Eun-Sol;Cho, Hyun-Seok;Kim, Kyung-Ho
    • Journal of Acupuncture Research
    • /
    • v.28 no.5
    • /
    • pp.65-76
    • /
    • 2011
  • Objectives : Study about needle retaining time. Methods : We reviewed the ancient and the present text of China with using the China academic journal(CAJ) of China national knowledge infrastructure(CNKI) Results & Conclusions : 1. Needle retaining time is important in acupuncture, because the therapy effect is influenced by it. 2. The time of needle retaining is up to those conditions like different disease, viscera and bowels(臟腑), meridian and collateral(經絡), obtaining Qi(得氣), seasons, constitution of the patients and acupuncture tools. In ${\ll}$Hwangdineijing(黃帝內經) ${\gg}$, needle retaining time is called by 'Zhiruzhichu(直入直出)', 'Jichu(疾出)', 'Liu(留)', 'Buliu(不留)', 'Jiuliu(久留)' and 'Liu ${\bigcirc}$ hu(留${\bigcirc}$呼)', and the time was shorter than nowadays. 3. The respiration number was counted to check needle retaining time but we can't find out any evidence. Recently in China, 'obtaining Qi(得氣)' and 'Qi arrival(氣至)' is used to check it. 4. Looking into clinical researches, different diseases need different needle retaining time. For example, 20~30min is appropriate time for musculoskeletal system. 60min is for circulatory system, 10~20min is for peripheral facial nerve paralysis. Insomnia and some stubborn diseases need longer time. Cold and heat(寒熱), deficiency and excess(虛實) are always influences the needle retaining as well. 5. It is important to figure out the most effective needle retaining time for different disease with the base of connection between needle retaining time and effect.

Low Temperature Hermetic Packaging using Localized Beating (부분 가열을 이용한 저온 Hermetic 패키징)

  • 심영대;김영일;신규호;좌성훈;문창렬;김용준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.1033-1036
    • /
    • 2002
  • Wafer bonding methods such as fusion and anodic bonding suffer from high temperature treatment, long processing time, and possible damage to the micro-scale sensor or actuators. In the localized bonding process, beating was conducted locally while the whole wafer is maintained at a relatively low temperature. But previous research of localized heating has some problems, such as non-uniform soldering due to non-uniform heating and micro crack formation on the glass capsule by thermal stress effect. To address this non-uniformity problem, a new heater configuration is being proposed. By keeping several points on the heater strip at calculated and constant potential, more uniform heating, hence more reliable wafer bonding could be achieved. The proposed scheme has been successfully demonstrated, and the result shows that it will be very useful in hermetic packaging. Less than 0.2 ㎫ contact Pressure were used for bonding with 150 ㎃ current input for 50${\mu}{\textrm}{m}$ width, 2${\mu}{\textrm}{m}$ height and 8mm $\times$ 8mm, 5mm$\times$5mm, 3mm $\times$ 3mm sized phosphorus-doped poly-silicon micro heater. The temperature can be raised at the bonding region to 80$0^{\circ}C$, and it was enough to achieve a strong and reliable bonding in 3minutes. The IR camera test results show improved uniformity in heat distribution compared with conventional micro heaters. For gross leak check, IPA (Isopropanol Alcohol) was used. Since IPA has better wetability than water, it can easily penetrate small openings, and is more suitable for gross leak check. The pass ratio of bonded dies was 70%, for conventional localized heating, and 85% for newly developed FP scheme. The bonding strength was more than 30㎫ for FP scheme packaging, which shows that FP scheme can be a good candidate for micro scale hermetic packaging.

  • PDF

Study on the Conduction Heat Transfer Characteristics According to the Heating Temperature of Lightweight Panel Wall material (경량칸막이 벽체재료의 수열온도에 따른 전도 열전달 특성 연구)

  • Park, Sang-Min;Lee, Ho-Sung;Choi, Su-Gil;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.46-56
    • /
    • 2018
  • The paper relates to a study on the conduction heat transfer characteristics according to the heating temperature of lightweight panel wall material. Plywoods, marbles, heat resistant glasses, as well as general gypsum board and fire-proof gypsum board, which have been widely used for lightweight panel wall material, were selected as experiment samples, and heating temperatures were set as $100^{\circ}C$, $200^{\circ}C$, $300^{\circ}C$, $400^{\circ}C$, $500^{\circ}C$ and $600^{\circ}C$. Next, each of the heating temperatures were introduced on the bottom part of the wall material for 30 minutes, and analyses were made on the heat transfer characteristics to the backside part on the top part through conduction. As results of the experiment, the maximum backside temperatures were measured up to $190^{\circ}C$ for a general gypsum board, $198^{\circ}C$ for a fire-proof gypsum board, $189^{\circ}C$ for a plywood, $321^{\circ}C$ for a marble, and $418^{\circ}C$ for a heat resistant glass as heating temperatures were introduced maximum of $600^{\circ}C$. In addition, the maximum change rate of conduction heat transfer were measured up to 85 W for a general gypsum board, 95 W for a fire-proof gypsum board, 67 W for a plywood, 1686 W for a marble, and 3196 W for a heat resistant glass as the maximum heating temperatures were introduced up to $600^{\circ}C$. Also, carbonization characteristics of the wallpapers were measured to visually check the danger of conduction heat transfer, and the results showed that smokes were first generated on the attached wallpapers for the heating temperature $600^{\circ}C$, which were 1021 s for a general gypsum board, 978 s for a fire-proof gypsum board, 1395 s for a plywood, 167 s for a marble, and 20 s for a heat resistant glass, and that the first generation of carbonization were 1115 s for a general gypsum board, 1089 s for a fire-proof gypsum board, 1489 s for a plywood, 192 s for a marble, and 36 s for a heat resistant glass.

Study on Judgment of Body Form and Settle Energy Flow before Diagnose the Patients (환자를 살피기 전에 보아야 하는 "입형정기(立形定氣)"에 대한 고찰)

  • Ko, Heung
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.5
    • /
    • pp.509-519
    • /
    • 2013
  • Through the study on judgment of Body form and settle Energy flow(立形定氣) before diagnose the patients, the results are as follows. The observation of the body form is to determine prosperity and deficiency of each internal organ. It is necessary to distinguish Body form loss(形脫) and Body form fullness(形充). Fat man(肥人), Thin man(瘦人), Creamy man(膏人), Muscular man(肉人), Small Fat man(脂人) are discriminated by fat distribution, fat content, and muscle mass. The observation of the body form means the observation of structure disorder, color change, develop part at body, head and face. The observation of the body form that is to determine prosperity and deficiency of each internal organ is from the limited knowledge of the anatomy. The observation of face color is considered by blood perfusion, blood oxygenation and accumulation of carotinoid, bilirubin and change of melanin in the facial skin. The prosperity and the deficiency of energy flow is considered by symptom combined with growth (<40 years) and aging (>40 years). The prosperity of energy flow includes the anger, anxious emotion and the deficiency of energy flow includes the fear, depressive emotion. The breathing type is expiratory exhalation like asthma patients in the prosperity of energy flow. The deficiency of energy flow is weakness to overcome the disease. The prosperity and the deficiency of energy flow are considered by body metabolic ratios (Basal metabolic Rate: BMR, Resting metabolic rate: RMR, Physical activity ratios: PASs). Development of subcutaneous fat is good in the person of prosperous energy flow. The person of prosperous energy flow is hard to overcome to heat weather than cold weather. The person of deficiency of energy flow has tendencies of low blood pressure, insufficiency of blood flow in the peripheral and being shocked. The person of deficiency of energy flow has tendencies of chronic fatigue syndrome or automatic nerve disorder. If the patient who has deficiency of energy flow has severe weight loss should be checked for the presence of disease. The observation of small and large of bone is to check the development and disorder of bone growth and aging. The observation of thickness and weakness of muscle is to check the development of muscle, particularly biceps, gastrocnemius, and rectus abdominal muscle. The observation of thickness and weakness of skin is to check the ability of regulating body temperature by sweating.

Low Temperature Hermetic Packaging by Localized Heating using Forced Potential Scheme Micro Heater (Forced Potential Scheme 미세 가열기를 이용한 부분 가열 저온 Hermetic 패키징)

  • 심영대;신규호;좌성훈;김용준
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.2
    • /
    • pp.1-5
    • /
    • 2003
  • In this project, the efficiency of localized heating for micro systems packaging is developed by using a forced potential scheme microheater. Less than 0.2 Mpa contact pressure was used for bonding with a 200 mA current input for $50{\mu}m$ width, $2{\mu}m$ height and $8mm{\times}8mm$, $5mm{\times}5mm$, $3mm{\times}3mm$ sized phosphorus-doped poly-silicon microheater. The temperature can be raised at the bonding region to $800^{\circ}C$, and it was enough to achieve a strong and reliable bonding in 3 minutes. The IR camera test results show improved uniformity in heat distribution compared with conventional microheaters. For performing the gross leak check, IPA (Isopropanol Alcohol) was used. Since IPA has better wetability than water, it can easily penetrate small openings, and is more suitable for conducting a gross leak check. The pass ratio of bonded dies was 67%, for conventional localized heating, and 85% for our newly developed FP scheme. The bonding strength was more than 25Mpa for FP scheme packaging, which shows that FP scheme can be a good candidate for micro-scale hermetic packaging.

  • PDF

Clinical Study on 1 Case of patient with Urinary Retention (요폐환자(尿閉患者) 1례(例)에 대한 임상적(臨床的) 고찰(考察))

  • Kim, Jae-Hyeng;Cho, Chung-Sik;Kim, Chul-Jung
    • Journal of Haehwa Medicine
    • /
    • v.14 no.1
    • /
    • pp.43-49
    • /
    • 2005
  • One case of patient with urinary retention was reported in this clinical study. After the study, the results were as follows: 1. Anulesis belongs to l$\acute{o}$ng-bi(癃閉) in oriental medicine and the patient of this case belongs to chronic anulesis. 2. The patient of this case was thought as broke out anuresis by vesical nerve palsy of diabetic bladder pathy and sequela of stroke, and ischuria of long lie down 3. The patient of this case changeable process is supposed to urinary frequency, 'bi(閉)', 'l$\acute{o}$ong(癃)', urinary incontinence and urinary frequency. 4. First time of drug treatment is GAMIPHALJENG-SAN(ji$\bar{a}$-w$\grave{e}$i-b$\bar{a}$-h$\bar{e}$ng-s$\check{a}$n) by oral administration that action of alleviate a fever, water utilization and metaphase, convalescence time of drug treatment is PHALMIWANGAMI (b$\bar{a}$-w$\grave{e}$i-w$\acute{a}$n-ji$\bar{a}$-w$\grave{e}$i), YIKLUENG-TANG(yi-ling-t$\bar{a}$ng), CHUKYOO-TANG(s$\grave{u}$-ni$\grave{a}$o-t$\bar{a}$ng) that action of recreation. 5. Accupuncture treatment is s$\bar{a}$n-x$\bar{i}$ng-xuw$\acute{e}$, zw$\acute{u}$-s$\bar{a}$n-li, qi-h$\check{a}$i, gu$\bar{a}$n-yu$\acute{a}$n, zh$\bar{o}$ng-ji by mild supplementing and reducing manipulation of needle and heat accupuncture is qi-h$\check{a}$i, gu$\bar{a}$n-yu$\acute{a}$n, zh$\bar{o}$ng-ji-xu$\acute{e}$. 6. The other treatment is a sitz bath that prevent of urinary tract infection, and relieve of initial acute auresis by using of urethral catheterization.

  • PDF

Failure Analysis and Heat-resistant Evaluation of Electric Fuel Pump for Combat Vehicle (전투차량용 전기식 연료펌프의 고장분석 및 내열성능 평가)

  • Kwak, Daehwan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.11
    • /
    • pp.634-640
    • /
    • 2020
  • Failure analysis and heat-resistant were performed for an electric fuel pump that is installed in the fuel tank to transfer fuel to the engine of combat vehicles. The fuel pump with a DC motor was disassembled and inspected to determine the cause of failure. The failure phenomenon was classified into three categories based on observations of the inside of the housing: burnt winding, quick brush abrasion, and fuel leak into the pump. Based on the inspection results, it was estimated that overheating was the main cause of failure. The thermal test was conducted under the no-load condition in 24 hours, and the thermal sensor was installed on the stator surface and the brush holder to check the possibility of damage to the winding due to overheating. When the ambient temperature of the fuel pump was set to 68 ℃, the stator temperature increased to 135.9 ℃, and the winding of the motor was almost damaged. The test results confirmed the lack of heat resistance of fuel pump windings, and suggested that the type F of insulation class (below 155 ℃) of the windings and varnish should be replaced with type C or higher that can be used above 180 ℃.

Treatment of Vertigo in Hyungsang Medicine (현훈(眩暈)의 형상의학적(形象醫學的) 치료(治療))

  • Kang, Kyung-Hwa;Kang, Duk-Soo;Lee, Yong-Tae
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.20 no.4
    • /
    • pp.793-798
    • /
    • 2006
  • Vertigo is one of the subjective symptoms which appears commonly in so many diseases that it is often neglected. But it needs active medical care because it can be a forewarning of serious illness like cerebral apoplexy. This thesis makes a study of vertigo in view of Hyungsang medicine. The followings are the conclusion drawn in diagnosis and treatment of Vertigo: Excess in the upper and deficiency in the lower part(上實下虛) is a main cause of male vertigo. Deficiency in the upper and excess in the lower part(下虛上實) is a general cause of female vertigo. Vertigo is also caused by the insufficiency of the kidney water(腎水) or reservoir of marrow(髓海). persons of Jung pe(精科) with large check bones , those of Fish type(魚類) with Dig mouth and thick lips ; and those with large heads are mainly attacked by this cause. A fleshy person's vertigo comes from the deficiency of Ki and damp phlegm(氣虛濕症) so it is cured by reinforcing Ki, removing dampness and dispelling phlegm. A slim person's vertigo comes from the deficiency of blood and dryness heat(血虛有火) so it is treated by tonifying the blood, cleaning heat away the heat. In case of womanly shaped male and manly shaped female, the vertigo is due to the phlegm fire. Wind-heat(風熱) can cause vertigo generally 施 the persons of following types : wind type(風人), running animal type(走類),bird type(烏類), and Yangmyung meridian type (陽明形). Vertigo also comes from consumption. The deficiency of Ki can be a cause of vertigo in case of male; persons with pale complexion; and those with pronounced noses. The deficiency of blood can be a reason of vertigo in the persons of Hyul type(血科) and those with pale eyelids and lips. The hypofunction of the splean and stomach brings on the deficiency of Ki and blood, which can give rise to the vertigo for those with large nose and mouth. The old people's vertigo comes from the hypofunction of Ki, blood, Yin and Yang.

Basic Study for performance Improvement of Fire Detectors System at Domestic Apartment Buildings (국내 공동주택 화재감지시스템의 성능개선을 위한 기초연구)

  • Son, Bong-Sae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.1
    • /
    • pp.533-538
    • /
    • 2014
  • This study examines the performance of and searches for improvements to the existing automatic fire detection systems installed at domestic apartment buildings as a basic study for development of intelligent fire detection systems specifically for apartments. Thus, this study aims to find out the problems in performance and maintenance of the existing fire detectors installed at apartment buildings which is the prerequisite process for development of intelligent fire detection system for that specific application. It is also found impossible to check whether or not the detectors installed at each apartment are in an operational state at normal times. This study finds that it is desirable to replace the slow-sensing heat detectors by a smoke and single smoke detectors which can detect a fire at its early stage in an effort to improve the problems of fire detectors installed at apartment buildings presently. Because we need to the independence fire detection system of apartment building.

Code Analysis of Effect of PHTS Pump Sealing Leakage during Station Blackout at PHWR Plants (중수로 원전 교류전원 완전상실 사고 시 일차측 열수송 펌프 밀봉 누설 영향에 대한 코드 분석)

  • YU, Seon Oh;CHO, Min Ki;LEE, Kyung Won;BAEK, Kyung Lok
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.16 no.1
    • /
    • pp.11-21
    • /
    • 2020
  • This study aims to develop and advance the evaluation technology for assessing PHWR safety. For this purpose, the complete loss of AC power or station blackout (SBO) was selected as a target accident scenario and the analysis model to evaluate the plant responses was envisioned into the MARS-KS input model. The model includes the main features of the primary heat transport system with a simplified model for the horizontal fuel channels, the secondary heat transport system including the shell side of steam generators, feedwater and main steam line, and moderator system. A steady state condition was achieved successfully by running the present model to check out the stable convergence of the key parameters. Subsequently, through the SBO transient analyses two cases with and without the coolant leakage via the PHTS pumps were simulated and the behaviors of the major parameters were compared. The sensitivity analysis on the amount of the coolant leakage by varying its flow area was also performed to investigate the effect on the system responses. It is expected that the results of the present study will contribute to upgrading the evaluation technology of the detailed thermal hydraulic analysis on the SBO transient of the operating PHWRs.