• 제목/요약/키워드: Heat Balance

검색결과 657건 처리시간 0.025초

DEVELOPMENT OF HIGH EFFICIENCY COGENERATION SYSTEM USING BIOGAS FOR THE LOWER POLLUTION OF THE ENVIRONMENTAL

  • Park, J.S.;Ishii, K.;Terao, H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.670-675
    • /
    • 2000
  • The purpose of the study is development and investigation about basic performance of the system operation on a dual fueled cogeneration system(CGS), which is operated with biogas and gas oil. As often seen in dual fueled CGS performance, the electric generating efficiency was obtained about 26□. Methane contained in the biogas could not bum completely at lower load, and it was discharged into exhaust gas. Considerable amount of the methane burned in the exhaust pipe, and the heat recovery ratio was 42□ on heat balance. As a result, the total heat efficiency, which is a summation of generating efficiency and heat recovery efficiency reached to about 70□. The supply of biogas into the engine reduces smoke density and NOx concentration in exhaust gas. At lower load, methane burned slowly and large portion of it was discharged without burning. Therefore the measures are desirable that promotes combustion of methane at lower load.

  • PDF

AN ANALYSIS OF MOLDING AND CURING OF SMC BY THE FINITE ELEMENT METHOD

  • Kim, Naksoo-
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1992년도 춘계학술대회 논문집 92
    • /
    • pp.177-200
    • /
    • 1992
  • A thermo-viscoplastic finite element program was developed to analyze the compression molding of SMC process. Deformation of the material was modelled by using the flow-rule. Heat balance during the process was coupled to the deformation. In the cure study, a kinetic model was adopted to describe the cure behavior. The numerical kinetic model was integrated with the thermo-viscoplastic numerical analysis by adding heat generation due to the chemical reaction of the workpiece in the heat transfer analysis. The integrated finite element program can simulate a whole sequential molding process including deformation, heat transfer, and chemical reaction. A practical SMC molding process with T-shaped substructure was simulated. The simulated results showed good agreements with experiments.

  • PDF

An Improved Mechanistic Model to Predict Critical Heat Flux in Subcooled and Low Quality Convective Boiling

  • Kwon, Young-Min;Chang, Soon-Heung
    • Nuclear Engineering and Technology
    • /
    • 제31권2호
    • /
    • pp.236-255
    • /
    • 1999
  • An improved mechanistic model was developed to predict a convective boiling critical heat flux (CHF) in the vertical round tubes with uniform heat fluxes. The CHF formula for subcooled and low quality boiling was derived from the local conservation equations of mass, energy and momentum, together with appropriate constitutive relations. The model is characterized by the momentum balance equation to determine the limiting transverse interchange of mass flux crossing the interface of wall bubbly layer and core by taking account of the convective shear effect due to the frictional drag on the wall-attached bubbles. Comparison between the present model predictions and experimental CHF data from several sources shows good agreement over a wide range of How conditions. The present model shows comparable prediction accuracy with the CHF look-up table of Groeneveld et al. Also the model correctly accounts for the effects of flow variables as well as geometry parameters.

  • PDF

초전도 코일에서 과도 열전달 효과를 고려한 상전도영역 전파속도 해석 (The Analysis of Normal zone Propagation Velocity with Transient Heat transfer Effect in Superconducting Coil)

  • 서용석;이상진;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.653-655
    • /
    • 1992
  • Longitudinal and transverse normal zone propagation in the superconducting coil are analyzed and propagation velocity is derived from the heat balance equations in the propagating boundary region. Transverse velocity is nearly $10^{-2}$ order of longitudinal velocity. Propagation velocity ie linearly proportional to the transport current. Increasing lamp current speeds up longitudinal velocity by 0.279 m/s under the applied field of 2T. Transient heat transfer has a significant effect on normal zone propagation velocity and it decreases longitudinal velocity by 4.2 m/s under the applied field of 2T as being compared to steady-state heat transfer.

  • PDF

공작기계 주축계 열적거동에 관한 연구 (A Study on the Thermal Behaviro of Machine Tool Spindle System)

  • 김종관
    • 한국생산제조학회지
    • /
    • 제8권1호
    • /
    • pp.28-34
    • /
    • 1999
  • According to the development of tool material and the improvement of machinability of cutting material like aluminium alloy, the higher spindle speed is needed. However, the higher speed causes the heat generation of bearings, the deformation of spindle unit parts, and the rotational accuracy of spindle to be worse. Therefore, it is essential to analyze and control the heat generation and the thermal behavior of spindle unit in order to have higher speed and better rotational accuracy. This paper shows the analogy between the analyzation of heat generation and thermal behavior of high speed spindle system by finite element method and the test results of actual temperature rise through running test, and shows the necessity of cooling the spindle and inner ring side of bearings for the thermal balance of high speed spindle system.

  • PDF

규모별 순환유동상 보일러의 열설계 변수 비교 평가 (Comparative Evaluation of Thermal Design Parameters of Different Sizes of Circulating Fluidized Bed Boiler)

  • 김태현;최상민
    • 한국연소학회지
    • /
    • 제16권4호
    • /
    • pp.16-22
    • /
    • 2011
  • The present paper discusses thermal design parameters of different sizes of circulating fluidized bed (CFB) boilers with capacities ranging from 2 MWe pilot scale boiler to a 600 MWe utility boiler. Physical boiler size and shape of furnace were identified and dimensional data have been summarized. By performing thermal design for each of the boilers, heat transfer surface area, furnace shape and size, and allocation of heat transfer surface for water-steam side heat absorption have been recalculated, and presented. Although boilers may have significantly different capacity, the facilities have common design parameters, when they are evaluated as basic thermal design processes. The significance of thermal design procedure is explicitly discussed.

제주시 폐기물환경사업소의 미활용에너지 활용방안 연구 (A Study on Unused Energy Management of Jeju City Waste Environment Center)

  • 김상혁;권기린;박윤철
    • 동력기계공학회지
    • /
    • 제8권1호
    • /
    • pp.48-54
    • /
    • 2004
  • In this study, waste heat of Jeju City Waste Environment Center is investigated and the utilization method is suggested with economical analysis of additional investment that needed for new facility. Energy balance of the typical facilities is considered in this study such as incineration plant and LFG power plant. The payback period of the investment which is used for the LFG power plant waste heat utilization facility is about 2.4 years and the economic profit of the facility during 10 years operation is up to 926 million won.

  • PDF

2종 LiBr - H2O 흡수식 열펌프의 시뮬레이션 (Simulation of the Second Kind LiBr - H2O Absorption Heat Pump)

  • 허준영;최영돈
    • 설비공학논문집
    • /
    • 제1권2호
    • /
    • pp.146-161
    • /
    • 1989
  • The second kind LiBr-$H_2O$ absorption heat pump system was simulated and the performances of it were predicted. The elements of heat pump system, evaporator, absorber and generator were analysed by solving the energy balance equations and concentration equations which describe the reactions between working fluids. The results show that the temperature gain of absorber is affected considerably by the operating conditions of heat pump system, on the other hand, COP is little affected by them.

  • PDF

대향류형 냉각탑에 대한 설계 및 성능해석을 위한 수치해석적 연구 (Numerical study for performance analysis and design of a counterflow type cooling tower)

  • 이상윤;이정희;최영기;유홍선
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.535-549
    • /
    • 1998
  • A numerical study for performance analysis of a counterflow type forced draft tower and natural draft cooling tower has been performed based on the method using the finite volume method with non-orthogonal body fitted and non-staggered grid system. For solving the coupling problem between water and air, air enthalpy balance, moisture fraction balance, water enthalpy balance, and water mass balance equations are solved with Navier-Stoke’s equations simultaneously. For the effect of turbulence, the standard k-$\varepsilon$ turbulent model is implied in this analysis. The predicted result of the present analysis is compared with the experimental data and the commercial software result to validate the present study, The predicted results show good agreement with the experimental data and the commercial software result. To investigate the influence of the cooling tower design parameters such as approach, range and wet bulb temperature, parametric studies are also peformed.

  • PDF

도로기상정보체계 활성화를 위한 노면온도예측 모형 개발 (A Road Surface Temperature Prediction Modeling for Road Weather Information System)

  • 양충헌;박문수;윤덕근
    • 대한교통학회지
    • /
    • 제29권2호
    • /
    • pp.123-131
    • /
    • 2011
  • 본 연구에서는 지표면과 대기사이의 열-에너지 균형원리를 이용한 노면온도예측모형을 개발하였다. 본 연구에서 개발된 노면온도예측모형은 두 가지 모듈로 구성되는데 Canopy 1은 지표면과 대기 간의 열 교환을 묘사하기 위한 것이고, Canopy 2는 열에너지 교환 과정에서 포장체 특성을 반영하기 위한 것이다. 모형 수행에 필요한 다양한 입력변수는 기상청으로부터 수집하였다. 개발된 모형의 성능을 평가하기 위해 청원-상주 간 고속도로 상 문의교 지점에 설치된 접촉식 노면온도측정센서로부터 수집한 노면온도자료와 모형 수행을 통해 나온 결과 값을 비교 하였다. 이러한 비교는 동절기(12월)와 동절기 외 기간(10월)에 걸쳐 수행되었다. 비교 결과, 두 온도의 평균오차 값이 ${\pm}2^{\circ}C$ 범위 내에 있어, 모형의 성능이 매우 우수한 것으로 판단된다. 이러한 연구는 동절기 도로관리에 다양하게 사용될 것으로 사료되고, 특히 도로 기상정보체계 운영에 핵심이 되는 노면온도 예측 알고리즘으로 사용될 수 있는 기초 연구가 될 것이다.