• 제목/요약/키워드: Heat Absorption Rate

검색결과 246건 처리시간 0.025초

Enhancement of Absorption Performance Due to the Wavy Film of the Vertical Absorber Tube

  • Kim Jung-Kuk;Cho Keum-Nam
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권2호
    • /
    • pp.41-48
    • /
    • 2006
  • Absorption performance at the vertical interface between refrigerant vapor and liquid solution of $LiBr-H_{2}O$ solution was enhanced by the waves formed due to the interfacial shear stress. The present study investigated experimentally and analytically the improvements of absorption performance in a falling film by wavy film flow. The dynamic parameter was the film Reynolds numbers ranged from 50 to 150. The energy and diffusion equations were solved simultaneously to find the temperature and concentration profiles at the interface of liquid solution and refrigerant vapor. Absorption characteristics due to heat and mass transfer were analyzed for the falling film of the LiBr aqueous solution contacted by refrigerant vapor in the absorber. Absorption performance showed a peak value at the solution flow rate of $Re_{f}>100$. Absorption performance for the wavy film flow was found to be greater by approximately 10% than that for uniform film flow. Based on numerical and experimental results, the maximum absorption rate was obtained for the wavy flow caused by spring insert. The difference between the measured and the predicted results were ranged from 5.8 to 12%.

INFLUENCE OF SLIP CONDITION ON RADIATIVE MHD FLOW OF A VISCOUS FLUID IN A PARALLEL POROUS PLATE CHANNEL IN PRESENCE OF HEAT ABSORPTION AND CHEMICAL REACTION.

  • VENKATESWARLU, M.;VENKATA LAKSHMI, D.;DARMAIAH, G.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제20권4호
    • /
    • pp.333-354
    • /
    • 2016
  • The present investigation deals, heat and mass transfer characteristics with the effect of slip on the hydromagnetic pulsatile flow through a parallel plate channel filled with saturated porous medium. Based on the pulsatile flow nature, exact solution of the governing equations for the fluid velocity, temperature and concentration are obtained by using two term perturbation technique subject to physically appropriate boundary conditions. The expressions of skin friction, Nusselt number and Sherwood number are also derived. The numerical values of the fluid velocity, temperature and concentration are displayed graphically whereas those of shear stress, rate of heat transfer and rate of mass transfer at the plate are presented in tabular form for various values of pertinent flow parameters. By increasing the slip parameter at the cold wall the velocity increases whereas the effect is totally reversed in the case of shear stress at the cold wall.

작업복 소재 직물의 액상 수분 전달 특성 및 표면특성 연구 (Liquid Moisture Management and Surface Properties of the Fabric in Transient Condition)

  • 유신정
    • 한국의류학회지
    • /
    • 제25권1호
    • /
    • pp.61-70
    • /
    • 2001
  • As important factors determining human sensorial comfort, liquid moisture management and surface properties of heat resistant workwear materials were examined. To figure out liquid moisture management properties of the test materials, absorption capacity, rate of absorption, and evaporation properties were assessed. A modified GATS(Gravimetric Absorbency Testing System) was used to measure the liquid moisture accumulation associated with the wicking of liquid moisture from sweating skin. The GATS procedure measures demand wettability of materials to take up liquid in a direction perpendicular to the fabric surface and it was modified to incorporate a special test cell and cover to assess absorption behavior in the presence of evaporation. Fabric stiffness, smoothness, number and the length of surface fibers, and an estimate of the contact area between the skin and fabric surface were measured to characterize the mechanical and surface properties of the test materials. Also an estimate of the force with which a fabric clings to moist skin was made using as wet-cling index.

  • PDF

수평관 외벽에서 친수성 표면처리가 응축열전달에 미치는 영향 (Effects of Hydrophilic Surface Treatment on Condensation Heat Transfer at the Outside Wall of Horizontal Tube)

  • 황규대;박노성;강병하
    • 설비공학논문집
    • /
    • 제12권6호
    • /
    • pp.533-540
    • /
    • 2000
  • Condensation heat transfer characteristics have been investigated experimentally when a water vapor is condensed on the outside of a horizontal copper tube in a condenser. This problem is of particular interest in the design of a LiBr-water absorption system. Hydrophilic surface modification was performed to increase the wettability on the copper tube. The optimum hydrophilic treatment condition using acethylene and nitrogen as reaction gas is also studied in detail. The results obtained indicate that the optimum reaction gas ratio of acethylene to nitrogen for hydrophilic surface modification was found to be 7 : 3 for the best condensation heat transfer. In the wide ranges of coolant inlet temperatures, and coolant mass flow rates, both the condensation heat transfer rate and the condensation heat transfer coefficient of a hydrophilic copper tube are increased substantially, compared with those of a conventional copper tube used in a condenser. It is also found that the condensation heat transfer enhancement by the hydrophilic surface modification still emains even after a hundred cycles of wet/dry processes.

  • PDF

이성분 나노유체($H_2O$/LiBr+나노입자)를 적용한 유하박막 흡수기의 열 및 물질전달 촉진 실험 (An Experimental Study on Falling Film Heat and Mass Transfer for Binary Nanofluids ($H_2O$/LiBr+Nanoparticles))

  • 김현대;김성수;남상철;정진희;강용태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.130-135
    • /
    • 2008
  • The objectives of this study are to investigate the combined heat and mass transfer enhancement using binary nanofluids as the working fluids in a $H_2O$/LiBr absorber. The result of heat and mass transfer experiment with the additives(Arabicgum, 2E1H) showed that the heat and mass transfer performance of binary nanofluid with 2E1H enhanced significantly in comparison with that without additive. In the case of 0.01wt% $Al_2O_3$ binary nanofluids with 2E1H, the vapor absorption rate increased up to 77% in comparison with that without additive. The heat transfer rate of 0.01wt% $Al_2O_3$ binary nanofluids with 2E1H increased up to 19%. Based on the experimental results, it is recommended that the $Al_2O_3$ binary nanofluid be good with 2E1H to improve the heat and mass transfer performance.

  • PDF

복사효과를 고려한 기체-입자 직접접촉식 열교환기 해석 (Analysis of a gas-particle direct-contact heat exchanger with two-phase radiation effect)

  • 박재현;백승욱;권세진
    • 대한기계학회논문집B
    • /
    • 제22권4호
    • /
    • pp.542-550
    • /
    • 1998
  • A direct contact heat exchanger using particle-suspended gas as a heat transfer medium is analyzed with an extended emphasis on the radiation, i. e., considering the radiation by both gas and particles. While the Runge-Kutta method is used for a numerical analysis of the momentum and energy equations, the finite volume method is utilized to solve the radiative transfer equation. Present study shows a notable effect by the gas radiation in addition to the particle radiation, especially when changing the chamber length as well as the gas and particle mass flow rate. When the gas and particle mass flow rate is raised, the gas temperature in the particle heater still increases as the gas absorption coefficient increases, which is different from the results for the small scale heat exchanger.

Modeling of vibration protection by shape memory alloy parts with an account of latent heat

  • Fedor S. Belyaev;Margarita E. Evard;Aleksandr E. Volkov;Maria S. Starodubova
    • Smart Structures and Systems
    • /
    • 제33권3호
    • /
    • pp.243-251
    • /
    • 2024
  • Modeling of vibrations of a rotating pendulum with working shape memory alloy rod has been performed in the frames of a microstructural model taking into account the latent heat release, absorption and the heat exchange during direct and reverse martensitic transformation. It has been shown that the influence of the latent heat, the rate of preliminary deviation of the pendulum from the equilibrium, the rate of heating and cooling can have a significant impact on the vibrations and damping characteristics of the system.

열복사에 의한 수직연료면의 점화현상 해석 (Ignition of a Vertically Positioned Fuel Plate by Thermal Radiation)

  • 한조영;백승욱
    • 대한기계학회논문집
    • /
    • 제19권9호
    • /
    • pp.2353-2364
    • /
    • 1995
  • The ignition phenomena of a solid fuel plate of polymethyl-methacrylate(PMMA), which is vertically positioned and exposed to a thermal radiation source, is numerically studied here. A two-dimensional transient model includes such various aspects as thermal decomposition of PMMA, gas phase radiation absorption, gas phase chemical reaction and air entrainment by natural convection. Whereas the previous studies considers the problem approximately in a one-dimensional form by neglecting the natural convection, the present model takes account of the two-dimensional effect of radiation and air entrainment. The inert heating of the solid fuel is also taken into consideration. Radiative heat transfer is incorporated by th Discrete Ordinates Method(DOM) with the absorption coefficient evaluated using gas species concentration. The thermal history of the solid fuel plate shows a good agreement compared with experimental results. Despite of induced natural convective flow that induces heat loss from the fuel surface, the locally absorbed radiant energy, which is converted to the internal energy, is found to play an important role in the onset of gas phase ignition. The ignition is considered to occur when the rate of variation of gas phase reaction rate reaches its maximum value. Once the ignition takes place, the flame propagates downward.

저온 폐열 활용을 위한 2중 효용 2단 흡수식 히트펌프 시뮬레이션 (Simulation of a Double Effect Double Stage Absorption Heat Pump for Usage of a Low Temperature Waste Heat)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제16권11호
    • /
    • pp.7736-7744
    • /
    • 2015
  • 막대한 산업용 에너지가 폐열로 버려지는 상황에서 폐열, 특히 저온 폐열의 효과적인 이용은 매우 중요하다. 본 연구에서는 $160^{\circ}C$의 고온 열원과 $17^{\circ}C$ 저온 하수열을 사용하여 $50^{\circ}C$의 온수를 $70^{\circ}C$로 승온시키며 성적계수는 1.6을 만족하는 2중 효용 2단 흡수식 히트펌프 사이클을 고안하였다. 제 1 재생기에서 증발한 냉매 증기는 제 1 응축기에서 응축하면서 제 2 재생기에서 다시 냉매를 발생시킨다. 이 냉매는 제 2 응축기를 거쳐 제 2 증발기에 모아진다. 이 냉매의 일부는 제 1 증발기로 이동하여 저온 열원을 받아들이고 제 1 흡수기를 거쳐 제 2 증발기에 공급된다. 제 2 증발기를 나온 냉매는 제 2 흡수기에서 용액에 흡수된다. 이 때 온수의 온도는 제 2 응축기와 제 2 흡수기에서 승온된다. 시행착오를 통하여 승온 $20^{\circ}C$, 성적계수 1.6을 만족시키는 유량과 열교환기의 UA 값을 도출하였다. 성적계수는 고온수의 온도가 증가할수록, 온수의 온도가 감소하고 유량이 증가할수록, 폐온수의 온도와 유량이 증가할수록, 용액 순환량이 감소할수록 증가한다. 반면 온수의 승온온도는 고온수의 온도가 증가할수록, 온수의 온도가 증가하고 유량이 감소할수록, 폐온수의 온도와 유량이 증가할수록, 용액 순환량이 증가할수록 증가한다. 또한, 열교환기의 UA 값이 증가할수록 성적계수 및 온수 승온 온도도 증가한다.

Study on High Performance and Compact Absorber Using Small Diameter Heat Exchanger Tube

  • Yoon Jung-In;Phan Thanh Tong;Moon Choon-Geun;Kim Eun-Pil;Kim Jae-Dol;Kang Ki-Cheol
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권4호
    • /
    • pp.463-473
    • /
    • 2006
  • The effect of tube diameter on heat and mass transfer characteristics of absorber in absorption chiller/heater using LiBr solution as a working fluid has been investigated by both of numerical and experimental study to develop a high performance and compact absorber. The diameter of the heat exchanger tube inside absorber was changed from 15.88mm to 12.70mm and 9.52mm. In numerical study a model of vapor pressure drop inside tube absorber based on a commercial 20RT absorption chiller/heater was performed. The effect of tube diameter, longitudinal pitch, vapor Reynolds number, longitudinal pitch to diameter ratio on vapor pressure drop across the heat exchanger tube banks inside absorber have been investigated and found that vapor pressure drop decreases as tube diameter increases, longitudinal pitch increases, vapor Reynolds number decreases and longitudinal pitch to diameter ratio increases. In experimental study, a system includes a tube absorber, a generator, solution distribution system and cooling water system was set up. The experimental results shown that the overall heat transfer coefficient, mass transfer coefficient. Nusselt number and Sherwood number increase as solution flow rate increases. In both of study cases, the heat and mass transfer performance increases as tube diameter decreases. Among three different tube diameters the smallest tube diameter 9.52mm has highest heat and mass transfer performance.