• Title/Summary/Keyword: Heat Absorption Rate

Search Result 246, Processing Time 0.031 seconds

The Pressure Drop and Heat Transfer Characteristics of a Direct Contact 4-Stage Fluidized Bed Heat Exchanger (직접 접촉식 4단 유동층 열교환기의 압력손실 및 열전달 특성)

  • 임동렬;박상일;전광민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.2
    • /
    • pp.325-335
    • /
    • 1992
  • In this work, direct contact 4-stage fluidized bed heat exchanger is experimentally studied to develop a new type of heat exchanger which recovers the energy contained in the high temperature waste gas exhausted from the industrial furnaces. A sand is used as a heat transfer medium in this experiment. To determine the optimum operating condition, 11 different perforated plates which have a different free area ratio with different hole diameter are used in the experiment. From the room temperature experiment, the pressure drop which is caused by fluidized bed formation is observed. The high temperature experiment is carried out to seek the optimum operating condition of high heat efficiency at low heat exchanger operation cost. The results of experiment are as following. The pressure drop in the high temperature condition can be predicted from the results of the room temperature experiment. And Nusselt number becomes smaller due to the increased interference between sand particles as Reynolds number increases when the dilute phase fluidized beds are formed in nigh temperature condition. But heat transfer amount through the total sand surface area become larger due to the large resident amount of sand. Considering the heat transfer amount and the heat exchanger operation cost, perforated plates which have either a 30% or 35% of free area ratio with 15mm of hole diameter are best fitted for our goal of this work. The values of .phi. which is a dimensionless number representing the absorption heat amount per unit sand rate are in the range from 0.4 to 0.5, when Reynolds number of waste gas ranges from 25-30 with these perforated plates.

Dielectric Characteristics through 2D-correlation Analysis of SiOCH Thin Film deposited by BTMSM/O2 High Flow Rates (BTMSM/O2 고유량으로 증착된 SiOCH 박막의 2차원 상관관계 분석을 통한 유전특성 연구)

  • Kim, Min-Seok;Hwang, Chang-Su;Kim, Hong-Bae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.6
    • /
    • pp.544-551
    • /
    • 2008
  • We have studied the dielectric characteristics of low-k interlayer dielectric materials fabricated by PECVD for various precursor's flow rates. BTMSM precursor was introduced with the flow rates from 42 sccm to 60 sccm by 2 sccm step in the constant flow rate of 60 sccm $O_2$. The absorption intensities of Si-O-$CH_x$ bonding group and Si-$CH_x$ bonding group changed synchronously for the variation of precursor flow rate, but the intensity of Si-O-Si(C) responded asynchronously with the $CH_x$ combined bonds. The heat treatment reduced the FTIR absorption intensity of Si-O-$CH_x$ bonding group and Si-$CH_x$ bonding group but increased the intensity of Si-O-Si(C). The nanopore and free space formed by the increasement of caged link mode and cross link mode of Si-O-Si(C) group implied the origin of low-k SiOCH films.

Window Integrated Solar Collectors (창호일체형 태양열 집열기)

  • Park, Seong-Bae;Lim, Seong-Whan;Park, Mann-Kwi
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.61-65
    • /
    • 2009
  • Window integrated solar collector is to simply install inside of the existing double glass window frame. Double glass window frame is consist of inner glass of Low-E coating and Silver coating, and outer glass of low iron reinforced glass. In order to secure natural lighting in a room, only 50% of window frame is covered with solar collectors. Solar absorption or transmission rate varies seasonally depending on sun angles. Part of inner glass where right behind of the solar plate is covered with silver coating to increase absorption rate of solar plate. The collector is made of a copper serpentine where aluminum fins are soldering. To improve the effect of insulation of inside of the window frame is recommend vacuum. As a result, we are making the 3th sample and will archieve below $F_RU_L=7.5W/m^2^{\circ}C$ that is the account of heat lossed, and above $F_R({\tau}{\alpha})=0.45$.

  • PDF

Cycle Analysis of Air-Cooled Double-Effect Absorption Cooling System Using H2O/LiBr+HO(CH2)3OH (H2O/LiBr+HO(CH2)3OH계 공냉형 이중효용 흡수식 냉방시스템의 사이클 해석)

  • Kwon, Oh-Kyung;Moon, Choon-Geun;Yoon, Jung-In
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.272-280
    • /
    • 1999
  • A cycle analysis was achieved to predict the characteristics by comprehensive modeling and simulation of an air-cooled, double-effect absorption system using a new $H_2O/LiBr+HO(CH_2)_3OH$ solution. The simulation results showed that the new working fluid may provide the crystallization limit 8% higher than the conventional $H_2O/LiBr$ solution. With a crystallization margin of 3wt%(weight%), the optimal solution distribution ratio was found in the range of 36 to 40%. Variation of cooling air Inlet temperature has a sensitive effect on the cooling COP and corrosion problem. The simulation of heat exchangers with UA value revealed that the absorber and the evaporator are relatively important for an air-cooled system compared with the condenser and the low temperature generator. The effect of cooling air flow rate, circulation weak solution flow rate and chilled water inlet temperature were also examined. The new working fluid may provide the COP approximately 5% higher than the conventional $H_2O/LiBr$ solution.

Cycle simulation of a triple effect LiBr/water absorption chiller (삼중효용 LiBr/물 흡수식 냉방기의 사이클 시뮬레이션)

  • 조광운;정시영;정은수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.79-87
    • /
    • 1998
  • Basic design of a 50USRT(175㎾) triple effect absorption chiller driven by hot gas has been carried out for both parallel and series flow cycles. Parallel flow cycle showed higher COP, however, the temperature in the generator was also higher than that in series flow cycle. Dynamic operation behavior of a parallel flow system at off-design conditions, such as the change in heat transfer medium temperature or the construction change of the system components, has been investigated in detail. It was found that the cooling capacity was seriously decreased by reducing hot gas flow rate and UA-value in the high temperature generator. However, the system COP was improved, because thermal load in the system components was reduced. The COP and the cooling capacity was found to be improved as cooling water temperature decreased or chilled water temperature increased. The optimum ratio of solution distribution could be suggested by considering the COP, the cooling capacity and the highest temperature in the system, which is critical for corrosion.

  • PDF

Dynamic Simulation of Transient Operations of a Solar Power-Assisted Absorption Chiller (태양열 보조열원을 이용한 흡수식 시스템의 동적 시뮬레이션에 의한 과도운전 특성 평가)

  • Shin, Young-Gy;Seo, Jung-A;Woo, Sung-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.78-85
    • /
    • 2010
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism were modeled. And solar radiation and the solar collector were also modeled along with its control design. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the issues of the excessive circulation flow rate and the mismatch between available solar power and cooling load discourages the use of the single mode, but the dual use of gas and solar power is recommendable in view of controllability and enhanced COP.

A Study on Dynamic Simulation of a Hybrid Parallel Absorption Chiller (병렬식 하이브리드 흡수식 냉온수기 동특성 시뮬레이션 연구)

  • Shin, Young-Gy;Seo, Jung-A;Woo, Sung-Min;Kim, Hyo-Sang
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.630-635
    • /
    • 2008
  • A dynamic model has been developed to investigate the operability of a single and double-effect solar energy assisted parallel type absorption chiller. In the study, main components and fluid transport mechanism have been modeled. Flow discharge coefficients of the valves and the pumps were optimized for the double-effect mode with solar-heated water circulated. The model was run for the single mode with solar energy supply only and the solar/gas driving double effect mode. And the cases of the double mode with and without the solar energy were compared. From the simulation results, it was found that the present configuration of the chiller is not capable of regulating solution flow rates according to variable solar energy input. And the single mode utilizing the solar energy only is not practical. It is suggested to operate the system in the double mode and the flow rate control system adaptive to variable solar energy input has to be developed.

  • PDF

Studies on the Improvements for GAYAKUM Sounding Boards (가야금(伽倻琴) 향판재(響板材)의 개선(改善)에 관(關)한 연구(硏究))

  • Hong, Byung-Wha
    • Journal of the Korean Wood Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.65-78
    • /
    • 1990
  • For the purpose of Improving the sounding boards for the conventional GAYAKUM, I was making approximately 202 specimens of radial board, 371 specimens of tangential board by cutting along the grain and the part of stem and 31 specimens of the disjointed traditional GAYAKUM made in Paulownia coreana. And it was conducted to measure specific gravity, dynamic Young's modulus, internal friction, resonant frequency, velosity of sound and width of annual ring by the method of the frexural vibration in a free-free bar in the audio frequency range. And it confirmed the juvenile wood by measuring wood fiber length of specimens. It was also conducted to investigate dynamic properties and moisture absorption by various heat-treatment and to test dynamic Young's modulus and internal friction for the disjointed conventional GAYAKUM. The results obtained were summarized as follow: 1. The Juvenile wood is located within about 7 annual rings from the pith in Paulownia coreana. 2. As increased with the specific gravity, the dynamic Young's modulus had more and more increased, but the internal friction had slightly decreased. 3. I think that radial board would be good for sounding board wood. because radial board is higher than tangential board in dynamic Young's mudulus and internal friction is lower than tangential board. 4. The value of mean dynamic Young's modulus on the conventional GAYAKUM, radial board and tangential board of 604 samples is $0.4283\pm0.037(\times10^{11}dyne/cm^2)$, $0.4316\pm(\times10^{11}dyne/cm^2)$ and $0.4234\pm0.112(\times10^{11}dyne/cm^2)$ respectively. The value of the radial board showed little higher than that of conventional GAYAKUM, but It had a similar tendency between conventional GAYAKUM and tangential board. 5. The annual ring width by four aspect is more narrow in north and west than that of others. 6. The values of specific gravity and dynamic Young's modulus in the mature wood showed higher than those of juvenile wood. 7. As the grain angle in the butt wood more increased to bark from pith, the dynamic Young's modulus were low. Then it was not good for sounding board. 8. It appeared that the heat-treatment for sounding board wood had a more effect to do the treatment of hotiron on surface after heat-treatment during 24 hours in $60^{\circ}C$ temperature. 9. As increased with the temperature, the rate of moisture absorption of heat-treatment wood had decreased. In conclusion, I thought that the sounding board wood for GAYAKUM would had the most effect to do the treatment of hotiron on surface after heat-treatment during 24 hours in $60^{\circ}C$ temperature using the radial board of mature wood.

  • PDF

Crystal Growth of Yb:YCa4O(BO3)3 and Investigation of Spectroscopic and Thermal Properties (Yb:YCa4O(BO3)3 단결정 성장과 분광 및 열적 특성 연구)

  • Kim, Choong-Ryeul;Lee, Hyeon-Jun;Yu, Young-Moon
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.8
    • /
    • pp.795-800
    • /
    • 2002
  • Yb:$YCa_4O(BO_3)_3$ (Yb:YCOB) single crystal, in which the concentration of $Yb^{3+}$ ion 20 at%, was grown by the Czocharalski method using an iridium crucible under N2 atmosphere. The optimum growth parameters to get a high quality of single crystals were found to be 1.5∼2 mm/h of pulling rate and 10∼20 rpm of rotation rate. According to the results of spectroscopic properties, absorption edge of Yb:YCOB was 236 nm. Two strong absorption line due to $Yb^{3+}$ ions were observed at 900 and 975 nm. Thermal expansion coefficients of Yb:YCOB crystal along a, b and c crystallographic axes from 320 to 650 K were 12.1${\times}10^{-6}$/K, 5.9${\times}10^{-6}$/K, 12.9${\times}10^{-6}$/K, respectively. Specific heat was 0.162 $cal/g{\cdot}K$ at 330 K.

A Study on the boiler efficiency with selecting the uppermost burners in the 870MW opposite wall fired boiler (870MW 대향류 보일러에서 최상부층 버너 선택운전에 따른 보일러 효율변화 고찰)

  • Woo, Gwang-Yoon;Kim, Soo-Seok;Park, In-Chan;Ham, Young-Jun;Lee, Eung-Yoon
    • Plant Journal
    • /
    • v.13 no.2
    • /
    • pp.46-51
    • /
    • 2017
  • In this study, the boiler efficiency and the change of boiler combustion state with the burner operation of the uppermost layer of 870MW opposite fired coal boiler were measured. Test results showed that the boiler efficiency was high in the order of the uppermost layer simultaneous operation of the front and rear burners, the front burner, and the rear burner operation. When the front and rear burners were operated simultaneously, the heat absorption rate of water walls in the boiler furnace was uniform at four side, and the temperature deviation of the left and right steam on the convection front surface decreased. As the heat absorption rate of the boiler improved, the loss of boiler exhaust gas decreased and the coal supply amount decreased by 8 tons/hour compared to the operation of the rear burner. This will contribute not only to the reduction of fuel cost but also to the reduction of greenhouse gas emissions.

  • PDF