• Title/Summary/Keyword: HeartBeat

Search Result 173, Processing Time 0.022 seconds

Assesment of Heart Rate Variability by Integral Pulse Frequency Modulation Model (IPFM 모델의 해석을 통한 심박변이도 해석)

  • Park, Sang-Eun;Kim, Jeong-Hwan;Jeung, Gyeo-Wun;Kim, Kyeong-Seop
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.799-804
    • /
    • 2015
  • This study aims at the new analysis of heart beat fluctuations by applying physiological Heart Rate Variability Model with representing the cardiac control system in sympathetic and parasympathetic-coupling oscillator constants, Cs and Cp. To find the effects of coupling constants on the beat-to-beat fluctuations, Integral Pulse Frequency Modulation (IPFM) model is adopted to generate the time series data of ECG R-peaks and represent them by poincaré scattergram plot in the time domain and HRV in the frequency domain, respectively. The actual poincaré plots and HRV spectrum are also analyzed by acquiring the experimental data from the subjects exposed to the emotional-stress invoking environment and the function of the coupling constants are verified in terms of antagonism in sympathetic and parasympathetic activity.

The Relationship and Mechanism Underlying the Effect of Conscious Breathing on the Autonomic Nervous System and Brain Waves (의식적 호흡이 자율신경과 뇌파에 영향을 미치는 기전에 관하여)

  • Kang, Seung Wan
    • Perspectives in Nursing Science
    • /
    • v.14 no.2
    • /
    • pp.64-69
    • /
    • 2017
  • Purpose: Breathing can be controlled either unconsciously or consciously. In Asian countries, various conscious breathing-control techniques have been practiced for many years to promote health and wellbeing. However, the exact mechanism underlying these techniques has not yet been established. The purpose of this study is to explore the physiological mechanism explaining how conscious breathing control could affect the autonomic nervous system, brain activity, and mental changes. Methods: The coupling phenomenon among breathing rhythm, heart rate variability, and brain waves was explored theoretically based on the research hypothesis and a review of the literature. Results: Respiratory sinus arrhythmia is a well-known phenomenon in which heart rate changes to become synchronized with breathing: inhalation increases heart rate and exhalation decreases it. HRV BFB training depends on conscious breathing control. During coherent sinusoidal heart rate changes, brain ${\alpha}$ waves could be enhanced. An increase in ${\alpha}$ waves was also found and the synchronicity between heart beat rhythm and brain wave became strengthened during meditation. Conclusion: In addition to the effect of emotion on breathing patterns, conscious breathing could change heart beat rhythms and brainwaves, and subsequently affect emotional status.

Response of Electrocardiogram of Nile tilapia, Oreochromis niloticus to Light Stimuli (광자극에 대한 역돔의 심전도)

  • Kim, Young-Ki;Yang, Yong-Rhim
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.38 no.3
    • /
    • pp.217-225
    • /
    • 2002
  • The authors examined the response of electrocardiogram(ECG) of Nile tilapia, Oreochromis niloticus [Linnaeus] to light stimuli. The experiments were performed in such a way that three levels of light stimuli(10, 100 and 400 lu$\chi$) were given to fishes with an electrode inserted into their bodies and then their ECGs were recorded continuously for 60 minutes in 16~18$^{\circ}C$. The results which are divided into by day and by night and then analyzed by fishes' conditions are as follows; 1. Nile tilapias reached a stable condition 3 minutes after anesthesia. In stable condition, the heart rate average was 47.6beat/min by day and 45.1beat/min by night. And the action potential average was 1.0.4$mutextrm{V}$ by day and 1.24$mutextrm{V}$ by night. 2. The heart rate average by three levels of light stimuli was, \circled1 In stimulus condition, in case of 10 lu$\chi$ 39.7beat/min by day and 38.2beat/min by night, in case of 100 lu $\chi$8.7beat/min by day and 36.9beat/min by night, and in case of 40.0. lux 36.8 beat/min by day and 35.8beat/min by night. \circled2 In recovery condition, in case of 10 lu$\chi$ 47.1beat/min by day and 46.0beat/min by night, in case of 100 lu$\chi$ 47.2beat/min by day and 45.6 beat/min by night, and in case of 400 lu$\chi$ 48.1beat/min by day and 46.6beat/min by night. 3. The action potential average by three levels of light stimuli was, \circled1 In stimulus condition, in case of 10 lu$\chi$ 1.22$mutextrm{V}$ by day and 0.71$mutextrm{V}$ by night, in case of 100 lu$\chi$ 0..63$mutextrm{V}$ by day and 0.90$mutextrm{V}$ by night, and in case of 400 lu$\chi$ 1.39$mutextrm{V}$ by day and 1.63$mutextrm{V}$ by night \circled2 In recovery condition, in case of 10 lu$\chi$ 1.26$mutextrm{V}$ by day and 1.59$mutextrm{V}$ by night, in case of 100 lu$\chi$ 2.63$mutextrm{V}$ by day and 3.65$mutextrm{V}$ by night, and in case of 400. lu$\chi$ 2.52$mutextrm{V}$ by day and 3.67$mutextrm{V}$ by night.

Response of Electrocardiogram of Mirror Carp, Cyprinus carpio to Light Stimuli (광 자극에 대한 향어의 심전도)

  • 양용림;김영기
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.37 no.2
    • /
    • pp.124-132
    • /
    • 2001
  • The authors examined the response of electrocardiogram (ECG) of Mirror carp, Cyprinus carpio [Linnaeus] to light stimuli. The experiments were performed in such a way that three levels of light stimuli (10, 100, and 400 lux) were given to fishes with an electrode inserted into their bodies and then their ECGs were recorded continuously for 60 minutes. The results which are divided into by day and by night and then analyzed by fishes conditions are as follows : 1. Mirror carps reached a stable condition 5 minutes after anesthesia. In this condition, the average heart rate was 64.9 beat/min by day and 65.3 beat/min by night. And the average action potential was 36.9 nV by day and 32.9 nV by night. 2. The average heart rate by three levels of light stimuli was, 1) In a stimulus condition, in case of 10 lux 68.7 beat/min by day and 46.0 beat/min by night, in case of 100 lux 53.4 beat/min by day and 44.1 beat/min by night, and in case of 400 lux 53.2 beat/min by day and 40.1 beat/min by night. 2) In a recovery condition, in case of 10 lux 67.9 beat/min by day and 57.2 beat/min by night, in case of 100 lux 68.8 beat/min by day and 61.0 beat/min by night, and in case of 400 lux 69.6 beat/min by day and 63.6 beat/min by night. 3. The average action potential by three levels of light stimuli was, 1) In a stimulus condition, in case of 10 lux 59.1 nV by day and 24.0 nV by night, in case of 100 lux 26.8 nV by day and 45.6 nV by night, and in case of 400 lux 71.7 nV by day and 14.4 nV by night. 2) In a recovery condition, in case of 10 lux 38.8 nV by day and 27.3 nV by night, in case of 100 lux 29.0 nV by day and 39.3 nV by night, and in case of 400 lux 66.4 nV by day and 21.4 nV by night.

  • PDF

Improvement of Fetal Heart Rate Extraction from Doppler Ultrasound Signal (도플러 초음파 신호에서의 태아 심박 검출 개선)

  • Kwon, Ja Young;Lee, Yu Bin;Cho, Ju Hyun;Lee, Yoo Jin;Choi, Young Deuk;Nam, Ki Chang
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.9
    • /
    • pp.328-334
    • /
    • 2012
  • Continuous fetal heart beat monitoring has assisted clinicians in assuring fetal well-being during antepartum and intrapartum. Fetal heart rate (FHR) is an important parameter of fetal health during pregnancy. The Doppler ultrasound is one of very useful methods that can non-invasively measure FHR. Although it has been commonly used in clinic, inaccurate heart rate reading has not been completely resolved.. The objective of this study is to improve detection algorithm of FHR from Doppler ultrasound signal with simple method. We modified autocorrelation function to enhance signal periodicity and adopted adaptive window size and shifted for data segment to be analysed. The proposed method was applied to real measured data, and it was verified that beat-to-beat FHR estimation result was comparable with the reference fetal ECG data. This simple and effective method is expected to be implemented in the embedded system.

Design of blood oxygen concentration and heart beat rate measuring system using photo diode (광다이오드를 이용한 산소포화도 및 맥박 측정기 설계)

  • Kim, In-Geon;Nam, Tae-Hun;Chung, Ik-Joo
    • Journal of Industrial Technology
    • /
    • v.33 no.A
    • /
    • pp.49-54
    • /
    • 2013
  • The U-healthcare is increasingly important as there is a growing tendency for elderly people to acquire chronic disease such as heart problems and high blood pressure. In this paper, we implemented an oximeter which can interact and communicate with the smart devices such as smartphones through which users can manage their measuring data. The designed pulse oximeter is capable of detecting hemoglobin saturation levels in the range of 70-100% and the heart beat rate(BPM) in the range of 30-240 BPM.

  • PDF

The Effect of Additives in the Cardioplegic Solution on the Recovery of Myocardium, Compariosn Among Albumin, Mannitol, and Glucose (심마비용액의 삼투압을 유지하기위한 첨가 물질들의 차이가 심근보호에 미치는 영향)

  • Kim, Eun-Gi;Lee, Jong-Guk;Lee, Sang-Heon
    • Journal of Chest Surgery
    • /
    • v.24 no.11
    • /
    • pp.1058-1067
    • /
    • 1991
  • High potassium cardioplegia is a widely accepted procedure to enhance myocardial protection from ischemic injuries associated with open heart surgery. Maintaining optimum osmolarity of the cardioplegic solution is one of the required conditions for an ideal cardioplegic solution Albumin is an frequently added component for maintaining optimum osmolarity of clinically used cardioplegic solutions. But the source of albumin is human blood so that the supply is limited and the cost of manufacturing is relatively high. Recently there are moves to minimized the use of blood product for fear of blood-associated infections or immunological disorders. In this experiment, we substituted mannitol or glucose for albumin added to the cardioplegic solution which has been used at the Wonju Medical College, To determine whether addition of mannitol or glucose instead of albumin in the cardioplegic solution can produce satisfactory myocardial protection during ischemia, three different groups of isolated rat heart perfused by modified Langendorff technique were studied. Wonju Cardioplegic Solution was selected as a standard high potassium[18mEq/L of K+] cardioplegic solution. Three kinds of cardioplegic solution were made by modifying the composition maintaining the same osmolarity[339$\pm$1mOsm/Kg] Isolated rat heart were perfused initially with retrograde nonworking mode and then changed to working mode. After measuring the heart rate, systolic aortic pressure, aortic flow, coronary flow, ischemic arrest by aorta cross clamp and cardioplegia was made maintaining the temperature of water jacket at 10oC. The heart was rewarmed and reperfused after 60min of ischemic arrest with intermittent cardioplegia at the 30min interval. The time to return of heart beat and the time required to get. Regular heart beat were observed after reperfusion. The recovery rate of the functional variables-heart rate, systolic aortic pressure, aortic flow, coronary flow and cardiac output were calculated and compared among the three groups of different cardioplegia-albumin, mannitol, and glucose. The wet weight and dry weight was measured and the water content of the heart as figured out for comparison. The time to return of heart beat was fastest in the albumin group, The functional recovery rates were best in the albumin group also. In the above conditions, albumin was the best additive to the cardioplegic solution compared to the mannitol or glucose.

  • PDF

An experimental study on the myocardial protection effect of the steroid mixed cardioplegic solution (Steroid를 첨가한 Cardioplegic solution의 심근보호효과에 관한 실험적 연구)

  • 유시원
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.565-573
    • /
    • 1984
  • The increasing use of cardioplegic solution for the reduction of ischemic tissue injury requires that all cardioplegic solution be carefully assessed for any protective or damaging properties. This study describes functional assessment of the efficiency of steroid in cardioplegic solution by using a Langendorffs perfusion model. Isolated rat heart were subject to a 2 minute period of coronary infusion with the steroid mixed cold cardioplegic solution immediately before and also at the midpoint of a 60 minutes period of hypothermic [10\ulcorner\ulcorner] ischemic arrest. The result of this study were as follows: 1.Spontaneous heart beat after ischemic arrest occurred 14 second later Langendorffs reperfusion in the steroid mixed Young & GIK group and 16 second later in the control group. [Young & GIK without steroid] A good recovery state of spontaneous heart beat was shown in both groups. 2.The percentage of recoveries of heart rate during the 30 minute after postischemic Langendorffs reperfusion was; at first 5 minute 106.3\ulcorner.7% [P<0.05] in the steroid mixed Young & GIK group. This percentage of recovery of steroid mixed Young & GIK group was significantly greater than the control group during the first 5 minute course. 3.The percentage of recovery of coronary flow during the 30 minute after postischemic Langendorffs reperfusion was; at first 5 minute 101\ulcorner.2% in the steroid mixed Young & GI K group. This percentage of recovery of the steroid mixed Young & GIK group was not significantly than the control group during the first 5 minute.

  • PDF

A Study On the Beat-To-Beat QT Interval Measurement

  • Jung, T.S.;Lee, J.M.;Park, K.S.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.203-204
    • /
    • 1998
  • ECG analysis is main techniques for diagnosing heart disease. In recent, some studies have been performed about detection of QT interval. But, it's difficult to detect QT interval because T wave is evasive. In this paper, we have detected peak point and end point of T wave and calculated QT interval. And the result has been compared with the other algorithm after detection of QT interval.

  • PDF

Design and Implementation of The UCC Realtime Sharing System (다자간 UCC 실시간 공유시스템에 대한 설계와 구현)

  • Son, Sung-Ok;No, Jae-Chun
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06d
    • /
    • pp.236-240
    • /
    • 2008
  • 본 논문은 IEEE 802.11 네트워크 환경에서 다중 노드를 하나의 클라스터링 시스템으로 구축하고, UCC(User Created Contents)와 같은 사용자 멀티미디어 데이터를 모든 노드가 실시간으로 공유할 수 있는 시스템을 제안한다. 이를 위해 본 논문은 응용계층의 새로운 패러다임 모델을 제안 하였고, 이에 따라 Ad Hoc 네트워크기술과 Clustering 기술을 사용하였다. 또한 제안된 기술의 안정된 서비스를 제공하기 위해서 HeartBeat 기술을 활용한 시스템 모델을 제안한다.

  • PDF