DOI QR코드

DOI QR Code

도플러 초음파 신호에서의 태아 심박 검출 개선

Improvement of Fetal Heart Rate Extraction from Doppler Ultrasound Signal

  • 권자영 (연세대학교 의과대학 산부인과학교실) ;
  • 이유빈 (연세대학교 의과대학 산부인과학교실) ;
  • 조주현 (연세대학교 의과대학 산부인과학교실) ;
  • 이유진 (연세대학교 의과대학 산부인과학교실) ;
  • 최영득 (연세대학교 의과대학 비뇨기과학교실) ;
  • 남기창 (연세대학교 의과대학 의학공학교실)
  • Kwon, Ja Young (Department of Obstetrics and Gynecology, Yonsei University College of Medicine) ;
  • Lee, Yu Bin (Department of Obstetrics and Gynecology, Yonsei University College of Medicine) ;
  • Cho, Ju Hyun (Department of Obstetrics and Gynecology, Yonsei University College of Medicine) ;
  • Lee, Yoo Jin (Department of Obstetrics and Gynecology, Yonsei University College of Medicine) ;
  • Choi, Young Deuk (Department of Urology, Yonsei University College of Medicine) ;
  • Nam, Ki Chang (Department of Medical Engineering, Yonsei University College of Medicine)
  • 투고 : 2012.08.27
  • 발행 : 2012.09.25

초록

산전 및 분만 중 연속적인 태아감시는 임상의에게 태아의 안녕 평가하는데 필요하다. 또한 태아의 심장박동은 임신 중 태아의 건강을 평가하는 중요한 파라미터이다. 초음파 도플러는 태아 심박을 비관혈적으로 측정할 수 있는 방법으로 매우 유용하다. 그러나 현재 임상에서 널리 쓰이고 있음에도 불구하고, 태아 심박을 검출하는데 있어서 제한적인 정보만 제공할 뿐만 아니라 검출 오류에 대한 문제가 완전히 해결되지 못하고 있다. 본 연구의 목적은 태아의 초음파 도플러 신호로부터 태아 심박을 검출하는 알고리즘을 간단한 방법으로 개선하고자 한다. 신호 주기를 검출하는데 가장 널리 쓰이는 자기상관함수의 수정된 함수를 제안하고, 신호의 주기를 찾기 위해 설정하는 데이터 분석 구간의 크기와 이동 간격을 가변하도록 하였다. 제안된 방법은 실제 산모에게서 측정된 데이터에 적용하여 태아 심박의 beat-to-beat 검출이 가능함을 확인하였으며, 태아 심전도 신호와도 비교하였다. 제안하는 방법은 간단하면서도 효과가 있으므로 실제 장비에 적용될 수 있을 것으로 기대된다.

Continuous fetal heart beat monitoring has assisted clinicians in assuring fetal well-being during antepartum and intrapartum. Fetal heart rate (FHR) is an important parameter of fetal health during pregnancy. The Doppler ultrasound is one of very useful methods that can non-invasively measure FHR. Although it has been commonly used in clinic, inaccurate heart rate reading has not been completely resolved.. The objective of this study is to improve detection algorithm of FHR from Doppler ultrasound signal with simple method. We modified autocorrelation function to enhance signal periodicity and adopted adaptive window size and shifted for data segment to be analysed. The proposed method was applied to real measured data, and it was verified that beat-to-beat FHR estimation result was comparable with the reference fetal ECG data. This simple and effective method is expected to be implemented in the embedded system.

키워드

참고문헌

  1. M. Peters, J. Crowe, J. F. Pieri, H. Quartero, B. Hayes-Gill, D. James, J. Stinstra and S. Shakespeare, "Monitoring the fetal heart non-invasively: a review of methods", J Perinat Med, Vol. 29, pp. 408-416, 2001.
  2. http://www.fda.gov/MedicalDevices/Safety/Alerts andNotices/ucm181503.htm
  3. 김동준, 강동기, "포노그램을 이용한 태아 심박률 검출 알고리즘의 개발", 전기학회논문지, 제51권, 제4호, pp. 167-174, 2002년 4월
  4. J. Jezewski, D. Roj, J. Wrobel and K. Horoba, "A novel technique for fetal heart rate estimation from Doppler ultrasound signal", Biomedical Engineering OnLine, Vol. 10, no. 92, Oct. 2011
  5. 이응구, 이두수, "태아심음주기 검출을 위한 고해상 피치 검출 알고리듬", 전자공학회 논문지 B편, 제31권, 제2호, 80-87쪽, 1994년 2월
  6. T. Shimamura and H. Kobayshi, " Weighted autocorrelation for pitch extraction of noisy speech", IEEE Trans. Speech and Audio Processing, Vol. 9, no. 7, pp. 727-730, Oct. 2001 https://doi.org/10.1109/89.952490
  7. 남기창, 음성, 성문 및 호흡의 통합 검사 장치 개발, 연세대학교 학위논문, 2004.
  8. 남기창, 권자영, 조희영, 윤보현, 김봉수, 최영득, "도플러 심음에서의 Beat-to-Beat 태아 심박수 검출", 대한전자공학회 하계학술대회, Vol. 5, no. 1, pp. 1478-1481, 2012년 7월