• Title/Summary/Keyword: Heart tube

Search Result 124, Processing Time 0.032 seconds

Results with Total Replacement of the Ascending Aorta and Reimplantation of the Coronary Arteries (대동맥관 폐쇄부전을 동반한 상행대동맥의 외과적 치료)

  • Ahn, Hyuk;Rho, Joon-Ryang
    • Journal of Chest Surgery
    • /
    • v.24 no.4
    • /
    • pp.352-356
    • /
    • 1991
  • From April, 1981, to April, 1990, 20 male and 7 female patients ranging in age from 17 to 63, were operated on for aortic insufficiency with an aneurysm of the ascending aorta. Ten patients were in New York Heart Association functional class II, 7 in class III, and ten in class IV. The surgical treatment in all cases consisted of total replacement of the ascending aorta with composite graft containing a prosthetic aortic valve and reimplantation of the coronary arteries by an intermediate tube graft. In 15 patients an uncomplicated annulo-aortic ectasia existed, and in 12 an aortic dissection; three of the latter group were operated during the acute phase. 17 patients showed typical Marfan syndrome, and 3 patients showed severe ascending aortic aneurysm secondary to the aortic valve disease. The overall operative mortality was 7%[2 deaths]. Those 2 deaths occurred following emergency operation due to associated aortic dissection, but no death during elective operation. All survivors have been followed-up during a period ranging 1 to 108 month[average 34 months]. There was no late mortality. Among the survivors, clinical improvement is readily apparent[2,3 in class I, 2 in class II ]. In conclusion, the treatment of aortic insufficiency associated with an aneurysm of the ascending aorta by insertion of a composite graft and reimplantation of the coronary arteries through an intermediate Dacron tube is a reliable method with low mortality and excellent results.

  • PDF

The Effects of Artificial Dead Space on the Pulmonary Ventilation of Intubated Children with Mechanical Ventilation (기관 삽관후 인공호흡기를 적용한 개심술 환아의 인공기도 체외 용적이 폐환기 상태에 미치는 영향)

  • 유정숙;윤선희;송계희;민열하
    • Journal of Korean Academy of Nursing
    • /
    • v.31 no.1
    • /
    • pp.31-42
    • /
    • 2001
  • This study was done to evaluate the effect reducing artificial dead space on intubated children. Data were collected from July 1st, 1998 to August 31st, 1999. The subjects were selected from a pediatric intensive care unit of 'S' hospital and intubated with 3.5 mm or 4.5 mm endotracheal tube after open heart surgery. They were composed of 34 patients : 17 patients were assigned to the experimental group and the rest of them were placed in the control group. The artificial airway volume was minimized in the experimental group, and the control group maintained the artificial airway volume. ETCO2, PaCO2, SPO2 were measured as indicators of pulmonary ventilation. The tools of this study were GEM-Premier and Space-Lab patient monitors. The data were analyzed using the SPSS/PC+ program. The $\chi$2 -test was used to find general characteristics. The t-test was used to test the homogenety of the pulmonary ventilation status and mechanical ventilation setting before intervention between the two groups. Also, the paired t-test was used to examine the hypothesis. The results can be summerized as : 1. CO2 can be expelled effectively from the body in case artificial dead space was decreased. 2. As the artificial dead space was reduced, the difference between ETCO2 and PaCO2 was decreased, in other words pulmonary ventilation was improved. 3. If the artificial dead space occupied above 15 percent of tidal volume, the effect of CO2 was retention revealed in the body. 4. If the artificial dead space occupied below effect. Based on the results, the following is suggested to be applied practically : 1. A kind of the ventilator circuit acting artificial dead space should be removed from the intubated children with mechanical ventilaion. 2. The endotracheal tube should not be cut because extra-body space of the endotracheal tube did not have an effect on the dead space of the intubated children. Since the researcher could not cover this aspect in the study, they recommend the following. 1. The study should be extended to the other pulmonary disease patients for the effect of improving pulmonary ventilation. 2. Also, further studying with a more narrow interval in the extra-body space of the artificial airway will be able to explain the point of artificial dead space with proper ventilation.

  • PDF

Inhibitory Effect of Chlorine Dioxide Using Reactive Oxygen Species Against Heart Contraction of the Indianmeal Moth, Plodia interpunctella (이산화염소의 활성산소 발생에 따른 화랑곡나방 심장박동 억제 효과)

  • Kim, Chul-young;Kwon, Hyeok;Kim, Wook;Kim, Yonggyun
    • Korean journal of applied entomology
    • /
    • v.56 no.2
    • /
    • pp.147-152
    • /
    • 2017
  • Heart contraction is essential for insect hemolymph circulation, in which various physiological changes need control of the heart contraction. Thus, interruption of heartbeats intimidate insect survival. Chlorine dioxide induces release of reactive oxygen species (ROS), which has been regarded as the main insecticidal agent. This study analyzed the effect of chlorine dioxide on heartbeats of the Indianmeal moth, Plodia interpunctella. The larvae have the dorsal vessel on the medial dorsal region in a form of an extending tube from the first thorax to 10th abdominal segment. Dorsal vessel contraction was noticeable between 3rd and 10th abdominal segments, where five heart chambers were observed. Average heartbeat rate was 118.6 beats per min at $25^{\circ}C$. However, the heartbeats varied with ambient temperature. Injection of chlorine dioxide to hemocoel suppressed the heartbeats in a dose-dependent manner. The suppressive effect of chlorine dioxide also increased with exposure time to gas form of the chemical at 100 ppm. However, vitamin E (an antioxidant against ROS) treatment significantly rescued the larvae treated with chlorine dioxide in the heart contraction activity. These results suggest that chlorine dioxide negatively influences on the heart contraction of P. interpunctella via its production of ROS.

Comparison between Transthoracic Fine Needle Aspiration Cytology and Gun Biopsy of Pulmonary Mass (폐종괴에 대한 경피적 세침흡인세포검사와 자동총부착 침생검의 비교)

  • Nam, Eun-Sook;Kim, Duck-Hwan;Shin, Hyung-Sik
    • The Korean Journal of Cytopathology
    • /
    • v.9 no.1
    • /
    • pp.55-61
    • /
    • 1998
  • To compare the diagnostic yields and complication rates of transthoracic fine needle aspiration cytology(FNAC) and gun biopsy in the diagnosis of pulmonary mass, a retrospective review was performed in 125 cases. Under the fluoroscopic guide, FNAC was performed by 20G Chiba needle in 91 cases, core biopsy was done by 18.5 G vaccum needle attached with automated biopsy gun in 74 cases and both procedures were done together in 37 cases. Overall sensitivity was 88.4% in FNAC and 87.5% in gun biopsy. For malignant pulmonary tumors, correct type correlation with final diagnosis was obtained in 33(76.7%) out of 43 cases by FNAC and 30(75.0%) out of 40 cases by gun biopsy. For benign pulmonary lesions, there were correct type correlation in 14(35.0%) out of 40 cases by FNAC and 14(53.8%) out of 26 cases by gun biopsy. The complication was pneumothorax and hemoptysis. Pneumothorax occured in 11.1% of FNAC, 10.9% of gun biopsy and 10.9% of both technique, among which chest tube drainages were necessary in one patient by gun biopsy and in three patients by both technique. Although no significant difference of diagnositc accuracy and complication rate was found between FNAC and gun biopsy, gun biopsy was more helpful in the diagnosis of pulmonary benign lesions than FNAC.

  • PDF

Airway Management with Reinforced Laryngeal in Mask Airway in a Child with Hypoplastic Left Heart Syndrome (좌심실형성부전증후군 환아의 치과치료를 위한 전신마취 시 강화 후두마스크를 이용한 기도 유지)

  • Kim, Kyung Jin;Shin, Teo-Jeon;Hyun, Hong-Keun;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Kim, Chong-Chul;Seo, Kwang-Suk
    • Journal of The Korean Dental Society of Anesthesiology
    • /
    • v.13 no.4
    • /
    • pp.221-224
    • /
    • 2013
  • Despite the laryngeal mask airway (LMA) has been widely used in anesthesia, its use is rare in the field of dentistry. Placing LMA in the oral cavity may interrupt dental treatment. However, there are some circumstances in which LMA is more advantageous than tracheal intubation for managing the airway. Especially, the reinforced LMA has a flexible tube shaft, rendering it more accessible for dental treatment. We report a case of dental treatment of a 3-year-old patient with hypoplastic left heart syndrome combined with pulmonary hypertension using reinforced LMA for airway management under general anesthesia. We also discuss the considerations of utilizing the reinforced LMA for dental treatment.

Successful Correction of Atypical Coarctation of the Aorta -Report of 4 Cases- (선천성 대동맥 축착증 4례)

  • 권중혁
    • Journal of Chest Surgery
    • /
    • v.12 no.3
    • /
    • pp.174-182
    • /
    • 1979
  • This is a report on four cases of successful surgical correction of coarctation of the aorta [COA] in Department of the Thoracic & Cardiovascular Surgery, Hanyang University Hospital. The first case was a postductal type of coarctation of the aorta associated with Patent ductus arteriosus [PDA], Persistent left superior vena cava [LSVC] and richly developed collateral circulation. Blood pressure was measured to be hypertensive at the arm, but hypotensive at the legs. The coarctation of the aorta was corrected with following procedure: Partial resection of the aortic wall with diaphragmatic structure lust above and below the coarctating line of the aorta, and then the defect of the aortic wall was closed by lateral aortographic suture. PDA was closed by ligation procedure. The second case a preductal type of coarctation of the aorta associated with PDA, LSVC, ventricular septal defect [VSD] and poorly developed collateral circulation. Normal blood pressure was measured at the arm, but hypotension was observed at the legs. Correction of coarctation of the aorta was performed under the establishment of tube bypass because of poor collateral circulation. After resection of coarctating short segment, end to end anastomosis was performed without any tension. PDA was closed by division procedure. Simple suture closure of VSD was performed by open heart surgery two weeks after correction of COA. The third case was a long segment COA without any other anomaly. Blood pressure was measured to be hypertensive at the arm, but hypotensive at the legs. Vascular prosthesis was performed using Teflon graft tube after resecting coarctating long segment [6.5 cm] of the aorta. The fourth case was a long segment COA associated with aortic insufficiency and richly developed collateral circulation. Normal blood pressure was measured at the arm, but hypotension was observed at the legs. Vascular prosthesis was performed using Teflon graft tube after resecting coarctating long segment [6.0 cm] of the aorta. Both blood pressure and peripheral pulse on the arm and the legs returned to normal postoperatively in all patients.

  • PDF

Role of Catecholamines in Ventricular Fibrillation (Catecholamines에 관(關)하여 -제4편(第四編) : 심실전동발생(心室顫動發生)에 있어서의 catecholamines의 의의(意義)-)

  • Lee, Woo-Choo
    • The Korean Journal of Pharmacology
    • /
    • v.19 no.1
    • /
    • pp.15-35
    • /
    • 1983
  • Although it has been well known that ventricular fibrillation is the most important complication during hypothermia, much investigation has failed to show the exact nature of the etiology of ventricular fibrillation. Recently, there has been considerable research on the relationship between sympathetic activity and ventricular fibrillation under hypothermia. Cardiac muscle normally contains a certain amount of norepinephrine and the dramatic effect of this catecholamines on the cardiac muscle is well documented. It is, therefore, conceivable that cardiac catecholamines might exert an influence on the susceptibility of heart muscle to tachycardia, ventricular fibrillation and arrhythmia, under hypothermia. Hypothermia itself is stress enough to increase tonus of sympatheticoadrenal system. The normal heart is supplied by an autonomic innervation and is subjected to action of circulating catecholamines which may be released from the heart. If the reaction of the heart associated with a variable amount of cardiac catecholamines is. permitted to occur in the induction of hypothermia, the action of this agent on the heart has not to be differentiated from the direct effects of cooling. The studies presented in this paper were designed to provide further information about the cardio-physiological effects of reduced body temperature, with special reference to the role of catecholamines in ventricular fibrillation. Healthy cats, weighing about 3 kg, were anesthetized with pentobarbital(30 mg/kg) intraperitoneally. The trachea was intubated and the endotracheal tube was connected to a C.F. Palmer type A.C. respirator. Hypothermia was induced by immersing the cat into a ice water tub and the rate of body temperature lowering was $1^{\circ}C$ per 5 to 8 min. Esophageal temperature and ECG (Lead II) were simultaneously monitored. In some cases the blood pH and serum sodium and potassium were estimated before the experiment. After the experiment the animals were killed and the hearts were excised. The catecholamines content of the cardiac muscle was measured by the method of Shore and Olin (1958). The results obtained are summarized as follows. 1) In control animal the heart rate was slowed as the temperature fell and the average pulse rates of eight animals were read 94/min at $31^{\circ}C$, 70/min at $27^{\circ}C$ and 43/min at $23^{\circ}C$ if esophageal temperature. Ventricular fibrillation was occurred with no exception at a mean temperature of $20.3^{\circ}C(21-l9^{\circ}C)$. The electrocardiogram revealed abnormal P waves in each progressive cooling of the heart. there was, ultimately, a marked delay in the P-R interval, QRS complex and Q-T interval. Inversion of the T waves was characteristic of all animals. The catecholamines content of the heart muscle excised immediately after the occurrence of ventricular fibrillation was about thirty percent lower than that of the pre-hypothermic heart, that is, $1.0\;{\mu}g/g$ wet weight compared to the prehypothermic value of $1.41\;{\mu}g/g$ wet weight. The changes of blood pH, serum sodium and potassium concentration were not remarkable. 2) By the adrenergic receptor blocking agent, DCI(2-3 mg/kg), given intramuscularly thirty minutes before hypothermia, ventricular fibrillation did not occur in one of five animals when their body temperature was reduced even to $16^{\circ}C$. These animals succumbed at that low temperature, and the changes of heart rate and loss of myocardial catecholamines after hypothermia were similar to those of normal animals. The actual effect of DCI preventing the ventricular fibrillation is not predictable. 3) Administration of reserpine(1 mg/kg, i.m.) 24 hours Prior to hypothermia disclosed reduced incidence of ventricular fibrillation, that is, six of the nine animals went into fibrillation at an average temperature of $19.6^{\circ}C$. By reserpine myocardial catecholamines content dropped to $0.045\;{\mu}g/g$ wet weight. 4) Bretylium pretreatment(20 mg/kg, i.m.), which blocks the release of catecholamines, Prevented the ventricular fibrillation under hypothermia in four of the eight cats. The pulse rate, however, was approximately the same as control and in some cases was rather slower. 5) Six cats treated with norepinephrine(2 mg/kg, i.m.) or DOPA(50 mg/kg) and tranylcypromine(10 mg/kg), which tab teen proved to cause significant increase in the catecholamines content of the heart muscle, showed ventricular fibrillation in all animals under hypothermia at average temperature of $21.6^{\circ}C$ and the pulse rate increased remarkably as compared with that of normal. Catecholamines content of cardiac muscle of these animals markedly decreased after hypothermia but higher than control animals. 6) The functional refractory periods of isolated rabbit atria, determined by the paired stimulus technique, was markedly shortened by administration of epinephrine, norepinephrine and isoproterenol. 7) Adrenergic beta-blocking agents, such as pronethalol, propranolol and sotalol(MJ-1999), inhibited completely the shortening of refractory period induced by norepinephrine. 8) Pretreatment with either phenoxftenbamine or phentolamine, an adrenergic alphatlocking agent, did not modify the decrease in refractory period induced by norepinephrine. From the above experiment it is possible to conclude that catecholamines play an important role in producing ventricular fibrillation under hypothermia. The shortening of the refractorf period of cardiac muscle induced by catecholamines mar be considered as a partial factor in producing ventriculr fibrillaton and to be mediated by beta-adrenergic receptor.

  • PDF

Biocompatibility Evaluation of Bent-Type Left Ventricular Assist Device During Long-Term Animal Experiment and Emergent Situation (장기 동물 실험 및 응급상황에서의 곡관형 좌심실보조장치의 생체적합성 평가)

  • Kang, Seong Min;Her, Keun;Choi, Seong Wok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.9
    • /
    • pp.739-745
    • /
    • 2014
  • Although medication is given to heart disease patients, conventional medication alone is not sufficient to treat heart disease. However, it has been reported that left ventricular assist device (LVAD) transplantation is an effective bridge to heart transplantation by assisting cardiac function. This study used long-term animal testing and emergency situations with a bovine model (Holstein) and canine model (Labrador-retriever) to evaluate the biocompatibility of LibraHeart-I (LH-1), which is a bent-tube type of LVAD that was developed in a previous study. In the long-term animal testing with the bovine model, the subjects survived for 49 days with no irregularities observed in their complete blood cell counts or the vital sign tests that were carried out during the test period. In short-term animal testing with the canine model, it was observed that blood did not remain inside the LH-I even without power support from an external drive source. In this study, the biocompatibility of the LH-I that was developed in a previous study was verified by the ejection performance during long-term animal testing and emergency situations.

Dose and Image Evaluation according to Changes in Tube Voltage during Chest X-ray Examination according to Automatic Exposure Control (자동노출제어장치 유·무에 따른 흉부 후·전방향 검사 시 관전압 변화에 따른 선량 및 영상평가)

  • Young-Cheol, Joo;Dong-Hee, Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.871-877
    • /
    • 2022
  • This study was conducted to improve the problems of exposure dose and image reading applied to patients due to the incorrect use of AEC during chest radiography. Images were acquired by dividing the case where AEC was used as the test condition and the case where AEC was not used. As a result of the study, the dose was reduced by 1.17% in 110 kVp without AEC than with AEC, 17.2% decrease at 100 kVp, 30.19% decrease at 90 kVp, and 46.45% decrease at 80 kVp. There was a significant difference in the statistical values according to the tube voltage change in the lung, trachea, and heart SNR average values with AEC and without AEC 110 kVp, but the difference in image quality was insignificant in actual images. When AEC was not applied at the same tube voltage, the dose could be reduced by 17.2% while maintaining the image quality similar to that of with AEC at 100 kVp without AEC. Therefore, rather than relying on AE conditions during chest radiographic examination, it is considered that the conditions should be considered for the examination while lowering the dose by selecting an appropriate tube voltage.

Doses of Coronary Study in 64 Channel Multi-Detector Computed Tomography : Reduced Radiation Dose According to Varity of Examnination Protocols (64 채널 Multi-Detector Computed Tomography를 이용한 관상동맥검사의 선량 : 검사 프로토콜 다변화에 따른 환자선량 감소)

  • Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.32 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • Purpose : To compare radiation dose for coronary CT angiography (CTA) obtained with 6 examination protocols such as a retrospectively ECG gated helical scan, a prospectively ECG gated sequential scan, low kVp technique, and cardiac dose modulation technique. Materials and Methods : Coronary CTA was performed by using 6 current clinical protocols to evaluate effective dose and organ dose in primary beam area with anthropomorphic female phantom and glass dosimetric system in 64 channel multi-detector CT. After acquiring topograms of frontal and lateral projection with 80 kVp and 10 mA, main coronary scan was done with 0.35 sec tube rotation time, 40 mm collimation ($0.625\;mm{\times}64\;ea$), small scan field of view (32 cm diameter), 105 mm scan length. Heart beat rate of phantom was maintained 60 bpm in ECG gating. In constant mAs technique 120 kVp, 600 mA was used, and 100 kVp for low kVp technique. In a retrospectively ECG gated helical CT technique 0.22 pitch was used, peak mA (600 mA) was adopted in range of $40{\sim}80%$ of R-R interval and 120mA(80% reduction) in others with cardiac dose modulation. And 210 mAs was used without cardiac dose modulation. In a prospectively ECG gated sequential CT technique data were acquired at 75% R-R interval (middle diastolic phase in cardiac cycle), and 120 msec additional padding of the tube-on time was used. For effective dose calculation region specific conversion factor of dose length product in thorax was used, which was recommended by EUR 16262. Results : The mean effective dose for conventional coronary CTA without cardiac dose modulation in a retrospectively ECG gated helical scan was 17.8 mSv, and mean organ dose of heart was 103.8 mGy. With low kVp and cardiac dose modulation the mean effective dose showed 54.5% reduction, and heart dose showed 52.3% reduction, compared with that of conventional coronary CTA. And at the sequential scan(SnapShot pulse mode) under prospective ECG gating the mean effective dose was 4.9 mSv, this represents an 72.5% reduction compared with that of conventional coronary CTA. And heart dose was 33.8 mGy, this represents 67.4% reduction. In the sequential scan technique under prospective ECG gating with low kVp the mean effective dose was 3.0 mSv, this represents an 83.2% reduction compared with that of conventional coronary CTA. And heart dose was 17.7 mGy, this represents an 82.9% reduction. Conclusion : In coronary CTA at retrospectively ECG gated helical scan, cardiac dose modulation technique using low kVp reduced dose to 50% above compared with the conventional helical scan. And the prospectively ECG gated sequential scan offers substantially reduced dose compared with the traditional retrospectively ECG gated helical scan.

  • PDF