• Title/Summary/Keyword: Health image

Search Result 1,880, Processing Time 0.025 seconds

Distortion of Magnetic Resonance Imaging for Different Types of Orthodontic Material (치과 교정 물질에 따른 자기공명영상의 왜곡)

  • Song, Hyun-Og;Lim, Cheong-Hwan;Lee, Sang-Ho;Yang, Oh-Nam;Baek, Chang-Moo;Jung, Hong-Ryang
    • Journal of Digital Convergence
    • /
    • v.12 no.2
    • /
    • pp.439-446
    • /
    • 2014
  • To evaluate the effects of an artifact by metal material for orthodontics in Magnetic Resonance Image (MRI) examination, wires and brackets used in orthodontics were selected and compared. Using a head coil, a $T_2$-weighted image, $T_1$-weighted image and FLAIR image were obtained. With obtained images, the sizes of the artifacts were measured and compared using Image J Program. In the research, the material with the biggest artifact in the wires and brackets for orthodontics was stainless steel wire. In the future, selecting and developing metal for correction should be considered also in other fields along with the purpose of orthodontics.

Evaluation of Unexposed Images after Erasure of Image Plate from CR System (CR 시스템에서 IP 잠상의 소거 후 Unexposed Image의 평가)

  • Lim, Bo-Yeon;Park, Hye-Suk;Kim, Ju-Hye;Park, Kwang-Hyun;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.20 no.4
    • /
    • pp.199-207
    • /
    • 2009
  • It is important to initialize Image Plate (IP) completely for removing residual latent image by sodium lamp for reliability and repeatability of computed radiography (CR) system. The purpose of this study was to evaluate latent images of computed radiography (CR) images respect to delay time after erasure of foregone latent image and its effect, and erasure level. Erasure thoroughness for CR acceptance test from American Association of Physicist in Medicine (AAPM) Report 93 (2006) was also evaluated. Measurements were made on a CR (Agfa CR 25; Agfa, BELGIUM) system. Chest postero-anterior (PA), Hand PA, L-spine lateral radiographs were chosen for evaluation. Chest phantom (3D-torso; CIRS, USA) was used for Chest PA and L-spine lateral radiography. For Hand PA radiography, projections was done without phantom. Except Hand PA radiographs, noise was increased with delay time, and ghost image was appeared on overexposed area. Effect of delay after erasure on latent image was not seen on naked eye, but standard deviation (SD) of pixel value on overexposed area was relatively higher than that of other areas. On Hand PA and Chest PA radiographs, noise were not occurred by adjustment of erasure level. On L-spine lateral images at lower erasure level than standard level, noise including ghost image were occurred because of high tube current. Erasure thoroughness of CR system in our department was to be proved by these evaluation. The results of this study could be used as a baseline for IP initialization and reliability of CR images.

  • PDF

Relationships among Body Image, Self-esteem and Health Promotion Behavior in Mastectomy Patients (유방절제술 환자의 신체상, 자아존중감과 건강증진행위의 관계)

  • Jeong, Kyeong-Sook;Park, Geum-Ja
    • Asian Oncology Nursing
    • /
    • v.7 no.1
    • /
    • pp.36-46
    • /
    • 2007
  • Purpose: This study was designed to fine out the relationships among body image, self-esteem and health promotion behavior in mastectomy patients. Method: Data were obtained by self -reported questionnaires from 218 patients undergone mastectomy from September 1 to October 15, 2005. And data were analyzed using SPSS/PC WIN 12.0 program. For the statistical analysis of the date, frequency and percentage, mean and standard deviation, t-test, ANOVA and Scheffe test and Pearson's correlation coefficients were used. Result: The mean scores of the body image, self-esteem, and health promotion of the subjects were $41{\pm}7.40$ (range of scale : 17 to 68), $22.22{\pm}4.95$ range of scale : 10 to 40), and $130.45{\pm}23.99$ range of scale : 50 to 200), respectively. There were significant differences with the score of body image by the work type (F=4.018, p= .008), a number of child (F=3.069, p= .029), and participation with self help group program (t=68.177, p= .001). There were significant differences with the score of self-esteem by the type of religion (F=4.546, p= .002), work type (F=4.488, p= .004), post operation period (F=2.814, p= .026), and participation with self help group program (t=12.901, p= .001). There were significant differences with the score of the health promotion behavior by the type of religion (F=3.066, p= .018), economic state (F=11.765, p= .001), level of education (F=6.285, p= .001), operation site (F=.368, p=.027), family history (t=6.557, p= .011), and hope of breast reconstruction (t=7.025, p=.009). Relationship between body image and self-esteem showed moderate positive correlation (r=0.631, p= .001). The relationship between body image and health promotion behavior showed slightly positive correlation (r=0.257, p= .001). The relationship between self-esteem and health promotion behavior showed moderate positive correlation (r=0.431, p=.001). Conclusion: For the increasement of the health promotion behavior, it is needed to improve body image and self-esteem in mastectomy patients. And, It is needed to encourage to participate with self help group program in mastectomy patients.

  • PDF

The Relationship among Pain, Body Image and Satisfaction in Hand-injured Workers (수부손상 근로자의 통증, 신체상 및 만족도에 관한 연구)

  • Yoon, Soon-Young;Kim, Min-Suk
    • Korean Journal of Occupational Health Nursing
    • /
    • v.19 no.2
    • /
    • pp.205-216
    • /
    • 2010
  • Purpose: The purpose of this study was to explore relationship among pain, body image and satisfaction in hand-injured workers. Methods: Using a sample of 96 out-patient workers with hand injuries, pain, body image and satisfaction were measured by VAS and Modified Jung Keum-hee's Tennesee Self Concept Scale. Repeated measured ANOVA and a Bonferroni correction for multiple statistical testing during post hoc analyses were conducted to evaluate relationship among pain, body image and satisfaction in hand-injured workers. Result: Functional satisfaction(r=.46, p<.001) and appearance satisfaction(r=.55, p<.001) significantly increased by treatment satisfaction. Functional satisfaction(r=.35, p=.001) and appearance satisfaction(r=.31, p=.002) increased by body image. But treatment satisfaction(r=-.20, p=.049), functional satisfaction (r=-.34, p=.001) and appearance satisfaction (r=-.39, p<.001) significantly decreased by pain. Conclusion: Poor pain management was related to bad body image and treatment satisfaction. Therefore, interventions targeting at pain management are needed for hand-injured workers.

Mediating Effect of Satisfaction in Major on the Relationship between Nursing Students' Self-Efficacy and Nurse's Image (간호대학생의 자기효능감과 간호사이미지의 관계에서 전공만족도의 매개효과)

  • No, Ji-Yeong;Park, Su-Jin;Bae, Do-Yi
    • Journal of East-West Nursing Research
    • /
    • v.18 no.2
    • /
    • pp.88-94
    • /
    • 2012
  • Purpose: The purpose of this study was to examine self-efficacy, satisfaction in major, nurse's image of nursing students, and mediating effect of satisfaction in major on the relationship between self-efficacy and nurse's image. Methods: Data were collected from 4th to the 7th of October in 2011, from 277 nursing students in Gyeongnam area using questionnaire, t-test, ANOVA, and correlation efficient were used for data analysis. Results: There were statistically positive relationships between self-efficacy, satisfaction in major, and nurse's image of nursing students. Satisfaction in major was found to completely mediate the relationship between self-efficacy and nurse's image. Conclusion: Self-efficacy exerted an influence on nurse's image through the mediating effect of satisfaction in major.

Prediction of Bone Aging by Adapting Image J (Image J를 활용한 뼈의 노화도 예측법)

  • Jung, Hong Moon;Won, Do Yeon;Jung, Jae Eun
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.63-67
    • /
    • 2012
  • Calcium density in human bones decreases as people are getting older due to the interior or exterior environmental factors. Bone aging forms osteoporosis. And this can bring out various spine fractures which develops a complications. Thus the prediction of seniliy is one of the important factors in spine diseases. Once spine aged, diverse fractures occur such as compression fracture and micro fracture. Side images of the spine by the digital radiography (DR) were prepared, and pixel arbitrary unit with Image J was measured from one spot in the lumbar bone part. By calculating pixel arbitrary unit of the simple contrast, it was obtained that the value of pixel arbitrary unit decreased as seniliy of bones increased. By simply applying Image J to the seniliy of patient's spine, the seniliy of bones predicts the level of danger with only digital radiography(2D) image. consequently we show that Image J value of pixel arbitrary unit index for predicts the level of precaution of osteoporosis patient.

  • PDF

Evaluation of Image Receptor Characteristics in Computed Radiography System Using Exposure Index in International Electrotechnical Commission (I) (IEC 규정 노출지수를 활용한 디지털 방사선 영상시스템에서의 영상 수용체간 특성평가 (I))

  • Park, Hyemin;Yoon, Yongsu;Roh, Younghoon;Kim, Sungjun;Na, Chanyoung;Han, Taeho;Kim, Jungsu;Jeong, hoiwoun;Kim, Jungmin
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.291-299
    • /
    • 2019
  • The International Electrotechnical Commission (IEC) has regulated the definition and requirements of the exposure index (EI). In this study, we calculated the EI of several image receptors in digital radiography system of two different manufacturers according to the method as per IEC, and evaluated the relationship with incident air kerma. To calculate the EI, w e obtained the characteristics curve of each image receptor by increasing the incident air kerma at RQA 3, 5, 7 and 9, respectively. As a result, there was no significant difference in the EI values between different image receptors of the same manufacturer, but EI values of different manufacturer was different despite the same air kerma was incident. Therefore, understanding the characteristics of the digital radiography systems is important in order to use EI as a tool for measuring and managing the radiation dose.

Nurse's Image:Perceived by Students of Elementary, Middle and High Schools in Taegru, Korea (대구지역 초.중.고등학생의 간호사 이미지에 관한 조사)

  • 허금희;이병숙
    • Health Policy and Management
    • /
    • v.9 no.2
    • /
    • pp.157-173
    • /
    • 1999
  • The purpose of this study was to investigate the image of nurse perceived by students of elementary. middle and high schools in Taegu. Korea. Also the details for establishing the image were analyzed. The subjects of this study were 1.119 students from elementary. middle and high schools in Taegu. Data were collected from July 1. to July 16. 1998 and analyzed with Frequency. X 2-test. t-test. ANOVA. and Stepwise Multiple Regression in SPSS 7.5. The results of this study were as follows; (1) There was a significant difference in the nurse's image among the three groups(F= 168.42. p= .000). and the elementary students had the most positive image among the groups. (2) There was a significant difference in the nurse's image between male andfemale students. and the male students had more positive image(t=3.20. p = .001) than female students. (3) The experiences of hospitalization. books. and mass media affected on establishing the image of nurse, and experienced students had more positive image than those who was not. (4) 22.3% of the nurse's image was explained by the educational years. (5) The students who could distinguish between nurses and nurse aids, who had a nurse in their family, and who had experiences of nurse by TV had more positive image than those who had not. The students who had experiences of family member's hospitalization had more negative image than those who had not.

  • PDF

Validation of Deep-Learning Image Reconstruction for Low-Dose Chest Computed Tomography Scan: Emphasis on Image Quality and Noise

  • Joo Hee Kim;Hyun Jung Yoon;Eunju Lee;Injoong Kim;Yoon Ki Cha;So Hyeon Bak
    • Korean Journal of Radiology
    • /
    • v.22 no.1
    • /
    • pp.131-138
    • /
    • 2021
  • Objective: Iterative reconstruction degrades image quality. Thus, further advances in image reconstruction are necessary to overcome some limitations of this technique in low-dose computed tomography (LDCT) scan of the chest. Deep-learning image reconstruction (DLIR) is a new method used to reduce dose while maintaining image quality. The purposes of this study was to evaluate image quality and noise of LDCT scan images reconstructed with DLIR and compare with those of images reconstructed with the adaptive statistical iterative reconstruction-Veo at a level of 30% (ASiR-V 30%). Materials and Methods: This retrospective study included 58 patients who underwent LDCT scan for lung cancer screening. Datasets were reconstructed with ASiR-V 30% and DLIR at medium and high levels (DLIR-M and DLIR-H, respectively). The objective image signal and noise, which represented mean attenuation value and standard deviation in Hounsfield units for the lungs, mediastinum, liver, and background air, and subjective image contrast, image noise, and conspicuity of structures were evaluated. The differences between CT scan images subjected to ASiR-V 30%, DLIR-M, and DLIR-H were evaluated. Results: Based on the objective analysis, the image signals did not significantly differ among ASiR-V 30%, DLIR-M, and DLIR-H (p = 0.949, 0.737, 0.366, and 0.358 in the lungs, mediastinum, liver, and background air, respectively). However, the noise was significantly lower in DLIR-M and DLIR-H than in ASiR-V 30% (all p < 0.001). DLIR had higher signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) than ASiR-V 30% (p = 0.027, < 0.001, and < 0.001 in the SNR of the lungs, mediastinum, and liver, respectively; all p < 0.001 in the CNR). According to the subjective analysis, DLIR had higher image contrast and lower image noise than ASiR-V 30% (all p < 0.001). DLIR was superior to ASiR-V 30% in identifying the pulmonary arteries and veins, trachea and bronchi, lymph nodes, and pleura and pericardium (all p < 0.001). Conclusion: DLIR significantly reduced the image noise in chest LDCT scan images compared with ASiR-V 30% while maintaining superior image quality.