• Title/Summary/Keyword: Header length

Search Result 33, Processing Time 0.023 seconds

Performance Evaluation of Post-installed Anchor according to Sleeve Length and Header Length (슬리브 및 헤드 길이에 따른 후설치 앵커의 인발성능평가)

  • Hur, Moo-Won;Chae, Kyoung-Hun;An, Yeong-Seung;Park, Tae-Won
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.25 no.2
    • /
    • pp.8-15
    • /
    • 2021
  • This study presents post-installed anchors whose heads and extension sleeves are improved. The optimal lengths of the extension sleeves and headers were analytically determined by simulations. As a result of analysis using Finite element method (FEM), 9.0mm and 3.0mm were determined as the optimal lengths of sleeves and headers respectively. In pull-out tests using the improved post-installed anchors, all specimens satisfied the coefficient of variation of 15%. Comparing the pull-out strengths of existing anchors and the improved anchors, it was increased by 1.25 times for anchors embedded with a depth of 50mm, and 1.54 times for 70mm. In the cases of high-strength concrete, the strengths were increased by 1.28 and 1.55 times for 50mm and 70mm respectively. Moreover, as a result of shear tests, the improved anchors perform the greater strength of 1.38 times than the existing anchors.

Analysis of a binary feedback switch algorithm for the ABR service in ATM networks (ATM망에서 ABR 서비스를 위한 이진 피드백 스위치 알고리즘의 성능 해석)

  • 김동호;안유제;안윤영;박홍식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.1
    • /
    • pp.162-172
    • /
    • 1997
  • In this paper, we investigated the performance of a binary feedback switch algorithm for the ABR(Available Bit Rate) service in ATM networks. A binary feedback switch is also called EFCI(Explicit Forward Congestion Indication) switch and can be classificed into input cell processing(IP) scheme according to processing methods for the EFCI bit in data-cell header. We proposed two implementation methods for the binary feedback switch according to EFCI-bit processing schemes, and analyzed the ACR(Allowed Cell Rate) of source and the queue length of switch for each scheme in steady state. In addition, we derived the upper and lower bounds for maximum and minimum queue lengths, respectively, and investigated the impact of ABR parameters on the queue length.

  • PDF

Optimum Design of Thermosyphon Solar Hot Water System (자연 대류형 태양열 온수기 최적 설계에 관한 연구)

  • Kang, Y.H.;Kwak, H.Y.;Lee, D.G.;Kang, M.C.
    • Solar Energy
    • /
    • v.18 no.4
    • /
    • pp.59-66
    • /
    • 1998
  • It was compared with experimental data to verify TRNSYS Model of the thermosyphon hot water system and the various simulations were conducted to optimize the component parameters of the system. To obtain consistent simulation results the system model, which could accurately describ the thermal storage tank temperature stratification and the friction head for mass flow rate, was used. The optimization of collector parameters(collector aspect ratio, riser numbers per header unit length), thermal storage tank parameters(ratio of tank length to tank diameter, heat exchanger type), system parameters(ratio of tank volume to collector area) was simulated by TRNSYS program. The simulation results indicate that the system performance is more effected by collector aspect ratio and the ratio of tank volume to collector area than the othor parameters.

  • PDF

An Investigation of the Major Factors Relating to the Flow Fluctuation at a Natural Gas Metering Facility (천연가스 계량설비에서 발생하는 유량 헌팅 현상 원인 분석)

  • An, Seung-Hee;Her, Jae-Young;Jeong, Jong-Tae;Sin, Chang-Hun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.158-165
    • /
    • 2005
  • KOGAS(Korea Gas Corporation) has about a hundred of local stations to supply natural gas to the city gas companies and the power stations. As some severe flow fluctuation phenomena are observed in several governor stations, the investigation about the reasons and factors which are relating to flow fluctuation has been started. Some field surveys hav been carried out and experimental studies have been performed to find the fluctuation mechanism. As a result, it is found that the flow fluctuation is related with the length of straight pipe in front of the meter, the size of the header pipe and the variation of demand at the city gas company and the power station. Furthermore. it is also proved that both the length of the transmitter cable and the status of the coating of signal transmission cable do not affect flow fluctuation, but the measurement range of the differential pressure transmitter influences flow fluctuation. On the other hand, as the averaging the flow fluctuation is converged to less than 0.1 % in almost all of the cases, it is concluded that the quantity of flow fluctuation do not relates to metering accuracy directly.

  • PDF

Evaluation of the Flux According to Membrane Distillation Module Structure and Operating Conditions Using PVDF Hollow Fiber Membrane (PVDF 중공사 분리막을 이용한 MD 모듈 구조 및 운전 조건에 따른 플럭스 영향 평가)

  • Min, Ji Hee;Lee, Seul ki;Gil, Nam Seok;Park, Min Soo;Kim, Jin Ho
    • Membrane Journal
    • /
    • v.28 no.2
    • /
    • pp.83-89
    • /
    • 2018
  • Hydrophobic porous PVDF hollow fiber membranes for Membrane Distillation (MD) were fabricated by a combination of thermally induced phase separation (TIPS) and stretching. The purpose of this study is to investigate the shape and operating conditions of the module and the effect of piping size on parallel connection. In the optimization experiment of the vacuum membrane distillation module, the flux decreased as the packing density and length of the membrane in the module increased. When the module was connected vertically, it was confirmed that the nearest to the inlet of the vacuum port was the highest flux. In selecting the size of the header pipe of the module, it was confirmed that the maximum flux is shown when the inner diameter area of the hollow fiber membrane and the inner diameter area of the header pipe are the same. Also, it is necessary to find the optimal linear velocity because the higher the linear velocity in the module, the higher the flux, but the pressure acting on the module also increases proportionally.

Implementation and Performance Analysis of Mobile Multimedia Terminal (H.324M) (이동 멀티미디어 터미널 (H.324M) 구현 및 성능 분석)

  • 박상현;윤종성;정진호;고성제
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.24 no.9A
    • /
    • pp.1295-1305
    • /
    • 1999
  • In this paper, we present the implementation and performance analysis of H.324M mobile multimedia terminal which s under standardization. The H.324M is the mobile extension of H.324 which is the standard for low bit rate multimedia terminals operating over GSTN. For H.324M, the multiplexing protocol (H.223) of H.324 is enhanced to protect data from the transmission errors over mobile channels. The multiplexing protocol of H.324M is classified into Levels 0, 1, 2, and 3 depending on the level of error protection. Each Level is analyzed according to different types of the data loss elements. Simulation results show that the loss caused by the corrupted flag and header produces the most serious performance degradation. Levels 1 and 2 which protect the header and flag are effective in reducing the total loss. Furthermore, the optimal flag length and threshold value for Levels 1 and 2 are determined.

  • PDF

An Performance Evaluation of Post-installed Anchor according to the Effective Embedment Length (유효묻힘깊이에 따른 후설치앵커의 인발성능평가)

  • Hur, Moo-Won;Chae, Kyoung-Hun;An, Yeong Seung;Hur, Moo-Won
    • Journal of the Korean Institute of Educational Facilities
    • /
    • v.26 no.4
    • /
    • pp.19-25
    • /
    • 2019
  • Concrete wedge anchor is one of structural components to transfer load of an object attached to a primary structure. Recently, as retrofitting concrete structure is becoming a main issue, mechanical capacity of the anchor should be secured enough. In spite of the structural safety of Cast-in-place anchor, Post-installed anchor is more widely used with ease of placement or change of construction method. However, the post-installed anchors domestically produced have excessive coefficient of variation over 15% of ultimate tensile strength, which yields deteriorated quality in tensile strength. In this research, tensile strength test of anchors, which have improved sleeve and header and produced by a domestic company, was conducted for two variables, concrete strength and effective embedment depth. As a result, enough coefficients of variations were secured in all specimens. Also, in comparison to foreign products, the domestic ones have equal or higher performance.

Lossless Audio Coding using Integer DCT

  • Kang MinHo;Lee Sung Woo;Park Se Hyoung;Shin Jaeho
    • Proceedings of the IEEK Conference
    • /
    • summer
    • /
    • pp.114-117
    • /
    • 2004
  • This paper proposes a novel algorithm for hybrid lossless audio coding, which employs integer discrete cosine transform. The proposed algorithm divides the input signal into frames of a proper length, decorrelates the framed data using the integer DCT and finally entropy-codes the frame data. In particular, the adaptive Golomb-Rice coding method used for the entropy coding selects an optimal option which gives the best compression efficiency. Since the proposed algorithm uses integer operations, it significantly improves the computation speed in comparison with an algorithm using real or floating-point operations. When the coding algorithm is implemented in hardware, the system complexity as well as the power consumption is remarkably reduced. Finally, because each frame is independently coded and is byte-aligned with respect to the frame header, it is convenient to move, search, and edit the coded data.

  • PDF

Implementation of Multiple Access Serial Communications with Improved Transmission Control (전송효율을 개선한 다중접속 직렬통신 구현)

  • Lee, Young-Suk;Han, Kyong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2000.07d
    • /
    • pp.2971-2973
    • /
    • 2000
  • In this paper, we proposed the implementation of multiple access serial communications with improved transmission control. For serial communications. RS232 protocol is used and the transmitting data and is merged to form data channel. Multiple host access is configures by using the common data channel and ground channel. 8bit data transfer with variable frame size is transferred by using the 16bit host ID. Packet is composed of HEADER, receiver ID. variable length data frame, TAIL and CRC informations. Multiple hosts are allowed to transfer packet with the other hosts through the common communication channel. Byte-stuffing is used to differentiate the transfer rate of PC is performed.

  • PDF

Design of the recuperator for the gas turbine/fuel cell hybrid power generating system (가스터빈/연료전지 혼합발전 시스템의 열교환기 설계)

  • Kwak, Jae-Su;Yang, Soo-Seok;Lee, Dae-Sung
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2105-2110
    • /
    • 2004
  • Plate-fin type recuperators for the gas turbine/fuel cell hybrid power generating system were designed using commercial design software, MUSE. Heat transfer efficiency and total pressure drop in the recuperator were calculated to confirm required recuperator performance. Both counter flow and cross flow type plate-fin recuperators were designed. Results show that the counter flow type has higher efficiency and short core length, but the cross flow type is simpler to construct because the cross flow type does not need additional distributors. Two or three headers for the each recuperator core will be designed and tested to evaluate best header design. The designed recuperators and headers which will be designed later will be constructed, tested, and used in gas turbine/fuel cell hybrid power generating system.

  • PDF