• Title/Summary/Keyword: Head size

Search Result 1,239, Processing Time 0.031 seconds

A Study on the Body Shape for Chinese Adult Women of Development of Apparel Sizing System (중국(中國) 성인(成人) 여성용(女性用) 의류치수규격(衣類値數規格) 성정(設定)을 위(爲)한 체형(體型) 연구(硏究) 제1보(第1報))

  • Wee, Hye-Jung;Sohn, Hee-Soon
    • Journal of Fashion Business
    • /
    • v.9 no.5
    • /
    • pp.15-36
    • /
    • 2005
  • The purpose of this study was to provide for the useful fundamental data by developing an appearl sizing system according to body types for Chinese adult female. Thus, it was to improve of fittness and coverage rate of exporting domestic clothing to China. As a sample, 1360 female women was seleted aged between 19 and 50 who resident in Beijing and Shanghai in China for characterization body types and development of apparel sizing system by classifying them. As for the method of this study was made of 111 items by indirect measures done during Jun. 23 $\sim$ Aug. 7, 2004. Data analysis were processed by SPSS WIN 10.0 Program was used to for technical statistical analysis, ANOVA(t-test and F-test), factor analysis, duncan's multiple test. The results from the study were as follows: As they are getting older, the horizontal size and length categories related to width, thickness, and circumference increased, and the height and vertical size that show the vertical size of body reduced. 1. The women in the Shanghai area had large head width, head thickness and head circumference, the categories related to the height and head, and the women in the Beijing area had larger in terms of width, circumference, length, angle and other categories. 2. Chinese Adult women's constitutional components determined by factor analysis, six components could be identified: factor 1 : constitutional obesty and width size, factor 2 : longistudinal body size, factor 3 : shoulder form and size, factor 4 : longistudinal upper body size, factor 5 : longistudinal under body size, factor 6 : shoulder dropping.

Effects of Rhizome Size and Mulching Materials on Agronomic Characteristics and Yield in Zingiber mioga ROSC. (양하(Zingiber mioga ROSC.) 지하경 크기와 피복재료가 주요형질과 수량에 미치는 영향)

  • 최성규;이종일
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.38 no.2
    • /
    • pp.112-116
    • /
    • 1993
  • The experiment was carried out to investigate the influence of rhizome size and mulching materials on some agronomic characters and flower-head yield of Gingiber mioga ROSCOE. The larger the size of rhizome was, the more the number of leaves developed, and the higher the yield was. The most suitable rhizome size for planting was found to be from I2cm to 15cm. Rice straw and polyethylene film mulching materials increased the soil porosity and reduced change of the soil moisture content. The yield of flower-head was highest in the straw-mulching plot, indicating that straw would be the best mulching material for growth and yield of flower-head in Gingiber mioga ROSCE.

  • PDF

Application of Partial-size Die forming Process to Semiellpisoidal Segment Head of the Pressure Vessel (압력 용기 반타원형 분할 경판의 제작에 있어서 부분 금형 성형 공정의 적용)

  • Kwon I. K.;Youn J. G.;Lee W. J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2005.05a
    • /
    • pp.97-100
    • /
    • 2005
  • The purpose of this study is to apply the partial-size die forming process to actual segment head farming process of semi-ellipsoidal heads and to verify the availability of the suggested forming method. The initial curvature for the preliminary forming process was determined through anticlastic behavior of plate bending and the partial-size die for final forming was designed based on the results of springback analysis using F.EA. From the results of actual forming, it was concluded that die design was appropriate and proposed forming process would be successfully applied to actual forming jobs.

  • PDF

An Experimental Study on Droplet Size according to Discharge Coefficient of Sprinkler Head (스프링클러 헤드의 방수상수에 따른 물방울 크기에 관한 실험적 연구)

  • Hur, Min Noung;Shin, Changsub
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.4
    • /
    • pp.16-21
    • /
    • 2017
  • The sprinkler system is a basic fire extinguishing system that uses water as an extinguishing agent. In order to evaluate the fire extinguishing performance of the sprinkler system, information such as the discharge angle, discharge speed, discharge pressure, flow rate, and water droplet size of the installed head are required. However, there is a lack of research on droplets size compared to other requirements. In this study, to evaluate the extinguishing characteristics of sprinkler system, the droplet size distribution was measured for various types of sprinkler heads actually used. The size of the droplet was measured using laser diffraction method. The 50% cumulative volume distribution ($D_{v50}$) according to discharge coefficient(K factor) was $540{\mu}m{\sim}695{\mu}m$ for K50, $542{\mu}m{\sim}1,192{\mu}m$ for K80, $980{\mu}m{\sim}1,223{\mu}m$ for K115 and $1,188{\mu}m{\sim}1,234{\mu}m$ for K202. Based on the measured results, the vaeiance of the droplet particle distribution and the distribution ($D_{v50}$) according to discharge coefficient(K factor) was $540{\mu}m{\sim}695{\mu}m$ for K50, $542{\mu}m{\sim}1,192{\mu}m$ for K80, $980{\mu}m{\sim}1,223{\mu}m$ for K115 and $1,188{\mu}m{\sim}1,234{\mu}m$ for K202. Based on the measured results, the vaeiance of the droplet particle distribution and the Rosin-Rammler index value are presented. As a result of the fire simulation with FDS, it was confirmed that the performance difference occurs according to the water droplet size distribution even when the same amount of water is used. Therefore, the extinguishing performance of the sprinkler system should be evaluated considering the droplet size distribution according to the sprinkler head type.

Study on the Effect of Particles Injected Into the Head/Disk Interface (헤드-디스크 인터페이스에 주입되는 입자의 영향에 대한 연구)

  • Han Je-Hee;Lee Rae-Jun;Kim Dae-Eun;Kang Tae-Sik;Cho Keung-Youn
    • 정보저장시스템학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.179-183
    • /
    • 2005
  • Particles in the HDD can cause serious damages such as scratches and thermal asperity(TA) at the head/disk interface(HDI). Accordingly, particles cause data loss including physical and electrical damages. To improve the reliability of head-disk interface, understanding the damage characteristics at the HDI due to particle interactions is required. The materials such as $A1_2O_3$, TiC and aluminum were used in this experiment. The size and hardness of particles injected into the HDI are closely relevant to surface damage caused the data loss on the disk and head. In this paper, a variety of scratches were analyzed using scanning electron microscope(SEM) and atomic force microscope(AFM). In order to analyze defects of very small size on the disk, optical surface analyzer(OSA) was also used.

  • PDF

A Study I on the Sizing Accuracy of the Characterized Defects of the Reactor Vessel Head Penetrations (원자로헤드 관통관 결함의 검출 정확성 연구)

  • Chung Tae-hoon;Kim Han-Jong
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2005.05a
    • /
    • pp.216-227
    • /
    • 2005
  • The head penetrations for control rod drive mechanism and instrumentation systems are installed at the reactor pressure vessel head of PWRs. Primary coolant water and the operating conditions of PWR plants can cause cracking of these nickel-based alloy through a process called primary water stress corrosion cracking (PWSCC). Inspection of the head penetrations to ensure the integrity of the head penetrations has been interested since reactor coolant leakages were found at U. S. reactors in 2000 and 2001. The complex geometry of the head penetrations and the very low echo amplitude from the fine, multiple flaws due to the nature of the see made it difficult to detect and size the flaws using conventional pulse-echo UT methods. Time-of-flight-diffraction technique, which utilizes the time difference between the flaw tips while pulse-echo does the flaw response amplitude from the flaw, has been selected for this inspection for it's best performance of the detection and sizing of the head penetration see flaws. This study defines the limits of the detectable and accurately sizable minimum flaw size which can be detected by the General TOFD and the Delta TOFD techniques for circumferentially and axially oriented flaws respectively. These results assures the reliability of the inspection techniques to detect and accurately size for various kind of flaws, and will also be utilized for the future development and qualifications of the TOFD techniques to enhance the detecting sensitivity and sizing accuracy of the flaws of the reactor head penetrations in nuclear power plants.

  • PDF

Optimization of head mass for tonpilz transducer using finite element method (유한요소법을 이용한 tonpilz 트랜스듀서의 head mass 최적화)

  • Seo, Jin-Won;Choi, Kyoon;Lee, Ho-Yong
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.25 no.4
    • /
    • pp.140-144
    • /
    • 2015
  • Effects of the shape, the size and the material of head mass on performances of tonpilz transducer were studied with a finite element method. The shape of head mass was changed with an angle between symmetric axis and side of head mass of transducer from 0 to 60 degree. As a result of the simulations, the bandwidth leached to 86.4 % at 35.5 degree in case of Al head mass. The size of head mass showed a decrease in the power of transducer with little change of bandwidth. For the Ti head mass, the transmitted power showed 100 % increase with a bandwidth of 88.1 % even though the weight of the head mass increased to 167 % of Al. This can be attributed to the mechanical properties like elastic modulus of Ti relative to Al.

Body-type Study for Hood Pattern - Focusing on the Shoulder and Shape of the Head - (후드(Hood) 패턴 설계를 위한 체형연구 -머리 및 어깨의 형태를 중심으로-)

  • Sohn, Hee-Soon;Shin, Jang-Hee
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • v.13 no.1
    • /
    • pp.37-46
    • /
    • 2011
  • To design a beautiful hood fitting an unspecific individual, focusing on body parts such as the head, neck and shoulder requires body size and type information, which applied by physical factors like size, types, and movements, etc. These parts consist of complicated types and structures. Accurate information should be a priority due to great individual differences and low correlation with other body parts. However, there is not a lot of detailed physical information nor design methods for hood design. Therefore, the purpose of this study is to select a study sample "hood" which is a recently emerging fashion item and to expand the necessary physical information for pattern design and draw body size of wearing part on Hood like head, cerbical portion and shoulder. Extract factors to consist on types and after divided into several types, a study comparing each type's physical characteristics was conducted. In order to do that, body measurement data have been collected by statistical treatment and analyzed reference with statistical treatment. The results of the study are predicted to be important data to develop various hood designs for the recent fashion trend. Factor analysis was conducted through main composition analysis about direct measured item on human body and index items. The results of factor analysis, composed factors of body type in this research object were extracted in total of 3 factors. To categorize the head, neck and shoulders of women in their early 20s women and determine their characteristics, variances with factor analysis became operative for Cluster analysis. With these clusters, women in their early 20s were categorized into three types. The results of this study are considered to affect largely for higher physical suitability on unspecified individuals when allowed absence of reference and the fact that body size only limited to item 'head circumstance' in terms of making hat and hood in the case of recent Korea. For the future, an experimental study of hood production should be conducted by using basic data from this study.

  • PDF

Development of Korean Representative Headforms for the Total Inward Leakage Testing on Filtering Facepiece Respirators

  • Ah Lam Lee;Xin Cui;Hayoung Jung;Hee Eun Kim;Eun Jin Jeon;Hyungjin Na;Eunmi Kim;Heecheon You
    • Safety and Health at Work
    • /
    • v.15 no.1
    • /
    • pp.42-52
    • /
    • 2024
  • Background: The lack of headforms that accurately reflect the head characteristics of Koreans and the demographic composition of the Korean population can lead to inadequate FFR testing and reduced effectiveness of FFRs. Method: Direct measurements of 5,110 individuals and 3D measurements of 2,044 individuals, aged between 9 and 69 years, were sampled from the data pool of Size Korea surveys based on the age and gender ratios of the Korean resident demographics. Seven head dimensions were selected based on the ISO 16976-2, availability of Size Korea measurements, and their relevance to the fit performance of FFRs. A principal component analysis (PCA) was performed using the direct measurements to extract the main factors explaining the head characteristics and then the main factors were standardized and remapped to 3D measurements, creating five size categories representing Korean head shapes. Lastly, representative 3D headforms were constructed by averaging five head shapes for each size category. Results: The study identified two main factors explaining Korean head characteristics by the PCA procedure specified in ISO 16976-2 and developed five representative headforms reflecting the anthropometric features of Korean heads: medium, small, large, short & wide, and long & narrow. Conclusion: This study developed representative headforms tailored to the Korean population for conducting total inward leakage (TIL) tests on filtering facepiece respirators (FFRs). The representative headforms can be used for TIL testing by employing robotic headforms to enhance the performance of FFRs for the Korean target population.

Epidemiologic Data, Tumor Size, Histologic Tumor Type and Grade, Pathologic Staging and Follow Up in Cancers of the Ampullary Region and Head of Pancreas in 311 Whipple Resection Specimens of Pakistani Patients

  • Ahmad, Zubair;Ud Din, Nasir;Minhas, Khurram;Moeen, Sarosh;Ahmed, Arsalan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.17
    • /
    • pp.7541-7546
    • /
    • 2015
  • Aim: To report the histologic findings on Whipple resection specimens and thus determine the extent and spread of carcinomas of ampullary region and head of pancreas in our population. Setting: Section of Histopathology, Department of Pathology, Aga Khan University Hospital (AKUH), Karachi, Pakistan. Materials and Methods: A case series of 311 consecutive Whipple resection specimens received between January 1,2003 and December 31, 2014. Specimens processed for histologic sections and representative sections submitted and histologically examined as per established and standard protocols. All relevant tumor parameters including histologic type, histologic grade, pathologic T and N stage and tumor size were assessed. Epidemiologic data were also recorded. All findings were analysed using SPSS 19.0 software. Results: Ampullary (periampullary) carcinomas were much more common than carcinomas of the head of the pancreas, especially in males, with an average age of 53 years. Mean tumor size was 2.5 cms, over 54% were well differentiated. A large majority were pT2 or pT3 and N0. Carcinomas of pancreatic head were also more common in males, mean age was 55 years, mean tumor size was 3.5cms, and over 65% were moderately differentiated. The majority were T2 or T3 and pN1. Prognostically, significant statistical correlation was seen with tumor grade and pathologic T and N stage (p values statistically significant). However, tumor size was not statistically significant. Conclusions: Ampullary carcinomas are more common compared to pancreatic carcinomas. Majority of ampullary carcinomas were well differentiated while majority of pancreatic carcinomas were moderately differentiated. Large majority of both types of cases were pT2 or T3. Histologic tumor grade and pathologic T and N stage are significantly related to prognosis in Pakistani patients with ampullary and pancreatic cancers.