Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.

Human Head Mouse System Based on Facial Gesture Recognition

  • Wei, Li;Lee, Eung-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.12
    • /
    • pp.1591-1600
    • /
    • 2007
  • Camera position information from 2D face image is very important for that make the virtual 3D face model synchronize to the real face at view point, and it is also very important for any other uses such as: human computer interface (face mouth), automatic camera control etc. We present an algorithm to detect human face region and mouth, based on special color features of face and mouth in $YC_bC_r$ color space. The algorithm constructs a mouth feature image based on $C_b\;and\;C_r$ values, and use pattern method to detect the mouth position. And then we use the geometrical relationship between mouth position information and face side boundary information to determine the camera position. Experimental results demonstrate the validity of the proposed algorithm and the Correct Determination Rate is accredited for applying it into practice.

  • PDF

Three-dimensional cone-beam computed tomography based comparison of condylar position and morphology according to the vertical skeletal pattern

  • Park, In-Young;Kim, Ji-Hyun;Park, Yang-Ho
    • The korean journal of orthodontics
    • /
    • v.45 no.2
    • /
    • pp.66-73
    • /
    • 2015
  • Objective: To compare condylar position and morphology among different vertical skeletal patterns. Methods: Diagnostic cone-beam computed tomography images of 60 adult patients (120 temporomandibular joints) who visited the orthodontic clinic of Hallym University Sacred Heart Hospital were reviewed. The subjects were divided into three equal groups according to the mandibular plane angle: hypodivergent, normodivergent, and hyperdivergent groups. Morphology of the condyle and mandibular fossa and condylar position were compared among the groups. Results: The hypodivergent and hyperdivergent groups showed significant differences in superior joint spaces, antero-posterior condyle width, medio-lateral condyle width, condyle head angle, and condylar shapes. Conclusions: Condylar position and morphology vary according to vertical facial morphology. This relationship should be considered for predicting and establishing a proper treatment plan for temporomandibular diseases during orthodontic treatment.

The Image Distortion Analysis of Levin-tube tip by Patient position and Incidence Angle when taking Mobile Chest AP Projection (Mobile Chest AP 검사 시 환자자세와 입사각도에 따른 Levin-tube tip의 영상왜곡 분석)

  • Lee, Jinsoo;Park, Hyonghu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.7
    • /
    • pp.467-471
    • /
    • 2015
  • This study's purpose is improve image quality to keep accurate tube angle in order to recognize distortion degree conditions by patient's position or tube angle and to provide exact clinical informations when taking chest AP projection for patient which have L-tube in stomach. The experimental equipment was ELMO-T6S by SHIMADZU corporation, then we put L-tube which attached 1 mm gap scales ruler on chest phantom surface. The experiment set by 90 kVp, 4 mAs, 120 cm distance. Each phantom position which changed supine, 30degree, 45degree, 60degree on the table exposured direct, ${\pm}5degree$, ${\pm}10degree$, ${\pm}15degree$ to head and feet directions. As a result, L-tube tip's position was changed by patient's position and tube angle. When patient's position is supine, tip's position change was lower than 30degree, 45degree, 60degree. We have to adjust patient's position or tube angle in order to occur image distortion by fault tube angle when confirming correct position L-tube tip through chest x-ray. Also, Radiological technologist try to make accurate evaluation index for satisfied L-tube insertion.

Positional change of the condylar heads after wearing complete denture on dental cone beam CT (치과용 콘빔 CT영상에서 총의치 장착 후 하악과두의 위치변화)

  • Lee, Bong-Ho;Kim, Jae-Duk;Chung, Chae-Heon
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.23-27
    • /
    • 2008
  • Purpose: The aim of this study was to evaluate the change in the position of the mandibular condyle within articular fossa by a CBCT after wearing complete denture (CD). Materials and Methods: CBCT of 34 temporomandibular joints were taken from 9 male and 8 female patients with CB $Mercuray^{TM}$ (Hitachi, Japan) before and after wearing a CD for rehabilitation. Position of mandibular condyle within articular fossa at centric occlusion was evaluated with $Vimplant2.0^{TM}$ (CyberMed, Korea) on the central parasagittal view and curved panoramic coronal view of the condylar head. A statistical evaluation was done with SPSS. Results: The range of anteroposterior positional rate (AP) of condylar head within articular fossa was -16-5 and -10-12 respectively on the right and left sides. Before wearing CD, the AP rate showed discrepancy between right and left sides (p<0.05). After wearing CD, both condyles showed a tendency to decrease in posterior condylar position (right side; p<0.05). The average discrepancy between right and left side in mediolateral positional rate (MD) was 15.5 and 4.5 respectively before and after wearing CD. The improvement was observed in mediolateral relationship of both condylar heads after wearing CD (p< 0.01). Before wearing CD, the average horizontal angle of long axis of condylar head was $79.6{\pm}2.7^{\circ}\;and\;80.1{\pm}5.7^{\circ}$ respectively on the right and left sides. After wearing CD, both condyles were rotated in the same direction in average on axial plane. Conclusion: We observed with CBCT the significant clinical evidence in case of positional change of mandibular condyle after wearing complete denture.

  • PDF

Three-dimensional Head Tracking Using Adaptive Local Binary Pattern in Depth Images

  • Kim, Joongrock;Yoon, Changyong
    • International Journal of Fuzzy Logic and Intelligent Systems
    • /
    • v.16 no.2
    • /
    • pp.131-139
    • /
    • 2016
  • Recognition of human motions has become a main area of computer vision due to its potential human-computer interface (HCI) and surveillance. Among those existing recognition techniques for human motions, head detection and tracking is basis for all human motion recognitions. Various approaches have been tried to detect and trace the position of human head in two-dimensional (2D) images precisely. However, it is still a challenging problem because the human appearance is too changeable by pose, and images are affected by illumination change. To enhance the performance of head detection and tracking, the real-time three-dimensional (3D) data acquisition sensors such as time-of-flight and Kinect depth sensor are recently used. In this paper, we propose an effective feature extraction method, called adaptive local binary pattern (ALBP), for depth image based applications. Contrasting to well-known conventional local binary pattern (LBP), the proposed ALBP cannot only extract shape information without texture in depth images, but also is invariant distance change in range images. We apply the proposed ALBP for head detection and tracking in depth images to show its effectiveness and its usefulness.

Broken Mayfield Head Clamp

  • Lee, Tae-Hoon;Kim, Sang-Jin;Cho, Do-Sang
    • Journal of Korean Neurosurgical Society
    • /
    • v.45 no.5
    • /
    • pp.306-308
    • /
    • 2009
  • The Mayfield head clamp is the most frequently used head clamp system in the field of neurosurgery. In many cases, surgery is performed with complete reliance on the safety of the MHC. However, we experienced an extremely rare case in which the MHC accidentally broke while installing this system for immobilization of the head and neck. This is a case report with a brief review of the literature. The patient was a 58-year-old female who was scheduled to undergo cervical laminoplasty under the diagnosis of degenerative spondylotic cervical stenosis. In an attempt to install an MHC, we fixed three pins in the scalp; however, the arm of the MHC system broke when force was applied from both directions. Fortunately, the patient remained in a stable position and did not sustain an injury to the head or neck. Fixation was performed using another MHC, and the surgery was performed successfully. The patient was discharged after surgery with no specific complications related to the MHC system. The authors experienced an extremely rare case of MHC breakage during application and report the importance of properly managing and maintaining the instruments in order to prevent fatal injury.

Analysis of Per-Position Characteristics Recognized by Tenure Women Managers (근속 여성관리자가 인식하는 직위별 특성 분석)

  • Jeong, Ji-ae
    • Journal of Practical Engineering Education
    • /
    • v.11 no.1
    • /
    • pp.105-115
    • /
    • 2019
  • This study focused on the importance of job position as a role model for female career adaptation. To do this, we used the KWMP data to conduct a Multinomial logit analysis to examine the influence factors of the tenure women managers. As a result, first, section chief position showed a low level of life satisfaction and showed difficulty of beginner's manager. Second, it is predicted that the position of the Deputy Head of Department will establish the identity of work as an intermediate manager. Third, head of department Director showed a high age, target status, possibility of achieving the target, and duration of the next job. Fourth, executive level has the least average experience of discrimination on monthly average wage. It was suggested that it is important to develop individual career by recognizing that the organizational atmosphere and personnel management are lower than those of the other positions. It was found that age, organizational atmosphere and personnel management, goal status, possibility of achieving goals, next job tenure period, monthly average wage, welfare, and life satisfaction factors were the most influential factors in women career adjustment. Finally, implications and limitations were discussed based on the results of this study.

Head Motion Detection and Alarm System during MRI scanning (MRI 영상획득 중의 피험자 움직임 감지 및 알림 시스템)

  • Pae, Chong-Won;Park, Hae-Jeong;Kim, Dae-Jin
    • Investigative Magnetic Resonance Imaging
    • /
    • v.16 no.1
    • /
    • pp.55-66
    • /
    • 2012
  • Purpose : During brain MRI scanning, subject's head motion can adversely affect MRI images. To minimize MR image distortion by head movement, we developed an optical tracking system to detect the 3-D movement of subjects. Materials and Methods: The system consisted of 2 CCD cameras, two infrared illuminators, reflective sphere-type markers, and frame grabber with desktop PC. Using calibration which is the procedure to calculate intrinsic/extrinsic parameters of each camera and triangulation, the system was desiged to detect 3-D coordinates of subject's head movement. We evaluated the accuracy of 3-D position of reflective markers on both test board and the real MRI scans. Results: The stereo system computed the 3-D position of markers accurately for the test board and for the subject with glasses with attached optical reflective marker, required to make regular head motion during MRI scanning. This head motion tracking didn't affect the resulting MR images even in the environment varying magnetic gradient and several RF pulses. Conclusion: This system has an advantage to detect subject's head motion in real-time. Using the developed system, MRI operator is able to determine whether he/she should stop or intervene in MRI acquisition to prevent more image distortions.

Eye Gaze Interface in Wearable System (웨어러블 시스템에서 눈동자의 움직임을 이용한 인터페이스)

  • 권기문;이정준;박강령;김재희
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2124-2127
    • /
    • 2003
  • This paper suggests user interface method with wearable computer by means of detecting gaze under HMD, head mounted display, environment. System is derived as follows; firstly, calibrate a camera in HMD, which determines geometrical relationship between monitor and captured image. Second, detect the center of pupil using ellipse fitting algorithm and represent a gazing position on the computer screen. If user blinks or stares at a certain position for a while, message is sent to wearable computer. Experimental results show ellipse fitting is robust against glint effects, and detecting error was 6.5%, and 4.25% in vertical and horizontal direction, respectively.