• Title/Summary/Keyword: Head fixation

Search Result 145, Processing Time 0.021 seconds

TWO PART MINI-IMPLANT AS AN EFFICIENT TOOL FOR INTERMAXILLARY FIXATION (분리형 미니 임플란트를 이용한 효과적인 악간고정법의 소개)

  • Lee, Won;Kim, In-Soo;Seo, Woon-Kyung;Heo, Hyun-A;Kim, Seong-Hun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.5
    • /
    • pp.477-482
    • /
    • 2006
  • The new type of orthodontic mini-implant named C-implant can be an effective alternative to conventional one-component mini-implant in the intermaxillary fixation (IMF) cases because of its particular design. The small size, two-part design, efficiency, and low cost of the C-implant make it applicable to various types of IMF cases easily such as fracture reduction and orthognathic surgery. The two part design resists highly to the fracture or deformation during implantation and removal. The long span head allows the patient to easily attach intermaxillary elastics, so that the patient can apply intermaxillary elastics for traction easily. Through this article, we tried to show the possibility of this appliance as a good adjunct for the IMF screw.

A Case Report of Head and Neck Neurofibroma Cured with Transitional Flap (국소피판으로 치료한 $6{\times}7cm$ 크기의 두경부 신경섬유종 1례)

  • Do Jae-Woon;Park Sang-Woo;Jeong Joon-Hun;Kang Tae-Woo
    • Korean Journal of Head & Neck Oncology
    • /
    • v.22 no.1
    • /
    • pp.36-39
    • /
    • 2006
  • The Neurofibroma is a benign neoplasm originating from neural tissue such as Schwann cell, fibroblast and peripheral fibroblast, which rarely converts to malignancy. About 25-45% of neurofibroma are located in head and neck, and the most common sites are lateral cervical region and mouth. Because of its high vascularity and invasion to the adjacent organs, surgical resection may be confronted and limited, moreover large neurofibroma can cause large defect that needs various kinds of flap. The factors related to clinically suspected malignancy are painlessness, abrupt increase in size, firm fixation, and central ulceration, although the malignancy rate of neurofibroma is low. The complete resection was failed several times at local clinic, the patient was transferred to our hospital. We have successfully removed the retroauricular neurofibroma using transposition flap & free skin graft on its large defects.

Reconstruction of Wrist Joint Using Vascularized Free Fibular Head Graft After the Wide Tumor Excision of Distal Radius (원위 요골 악성 종양의 광범위 절제술 후 혈행성 유리 비골 두 이식을 이용한 수근관절 재건술)

  • Song, Seok-Whan;Lee, Yoon-Min
    • Archives of Reconstructive Microsurgery
    • /
    • v.20 no.1
    • /
    • pp.82-88
    • /
    • 2011
  • Vascularized free fibula head transfer is an established method for reconstruction of long bone defects of the upper limb involving the distal radius or the proximal humerus. For the wrist following tumor resection, in cases of resection of the radial articular surface, three reconstructive options are possible: 1. fibular head transfer to replace the radial joint surface, 2. fixation of the fibula to the scaphoid and lunate, 3. complete wrist fusion. The decision on the type of the operation depends on the amount of the resection and the remained normal anatomical structures, and also the necessity of function of the wrist in the future. The authors believe that the vascularized free fibula head graft is a safe and reliable method for reconstructing the upper limb, especially for patients with a defect of the distal radius, and report the operative methods, donor vascular consideration, complications, and functional result after this operation.

  • PDF

Development of Devices for Improving the Reducibility of Patient Positioning on a Breast Board (Breast Board를 이용한 방사선치료에서 환자 위치 재현성 향상 방안에 대한 연구)

  • Huh Soon Nyung;Cho Woong;Park Yang Kyun;Ha Sung Whan
    • Radiation Oncology Journal
    • /
    • v.23 no.2
    • /
    • pp.123-130
    • /
    • 2005
  • Purpose: We wanted to improve the setup reproducibility of breast cancer patients when utilizing a commercially available breast board for radiation therapy. The breast board was modified by using a new head rest and 2 types of board fixation devices. Materials and Methods: A conventional head/neck rest was modified to be positioned in various slots of the breast board, and it was fabricated 1 cm thinner to provide more comfort to a patient when the patient's neck was rotated. This rest improves the uncertainty of the daily setup. Also, the sagging problems at the left and right sides became negligible with the two types of board fixation devices: (1) the stair type, and (2) the arm type. The first device consists of an upper/lower holder with 4 stair-types of grooves and 4 rectangular Inserts. In order to cover the whole range of vertical setup of the breast board, 4 rectangular inserts were needed, and each covered 10 steps. The arm-type fixation device was also fabricated and attached to the breast board, It had two aluminum bars that were fixed by utilizing a lock-type of screw. These devises were evaluated with two volunteers in order to prove the effectiveness of the improved setup accuracy. Results; The developed cranio-caudal fixation device demonstrated that it could reduce the cranio-caudal error by nearly $55\%$ compared to the old device. As for left-and-right inclination, the stair-type and arm-type fixation devices can reduce the relative inclination by nearly $80\%$ and $90\%$, respectively, compared to the breast board without the fixation device. Conclusion: It was verified that the developed devices were effective for positioning the patients and for avoiding inclination of the breast board.

CLINICO-STATISTICAL ANALYSIS OF POSSIBLE FACTORS LEADING TO PROBLEMS IN THE SURGICAL TREATMENT OF UNILATERAL MANDIBLAR CONDYLE FRACTURES (편측 하악 과두골절의 관혈적 치료에 있어서 예후에 영향을 줄 수 있는 인자들에 관한 임상 통계학적 연구)

  • Sung, Hun-Mo;Lee, Dong-Keun;Min, Seung-Ki;Oh, Seung-Hwan;Jang, Kwan-Sik
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.23 no.1
    • /
    • pp.31-39
    • /
    • 2001
  • The purpose of this study is to reveal the factors leading to the problem of unilateral condylar fractures and suggest a treatment guideline of treatment for good prognosis in surgical treatment. The factors can be age, sex, fracture site, degree of displacement, posterior occlusion loss, post-operative alteration of condylar head position, post-operative condylar head resorption, and maxillomandibular fixation period. One hundred and eleven patients with unilateral condylar fractures, who were treated by surgical method from 1990 Feb. to 2000 Feb., were studied. Minimum follow-up period was 6 months. The results were as follows ; 1. In the age group of $41{\sim}60$, females had significantly higher complication rate than males, therefore we must be careful about treatment of female in this age group 2. In level I fractures of the mandibular condyle, because there were abundant complications when the patients were treated with fragment removal, conservative treatment is recommended over the surgical approach. 3. There were no differences in the complication rate, in the level II, III fractures. but were severe complications in the cases of patients treated by Dr.Nam's method or fragment removal. Therefore, open reduction and internal fixation is recommended over Dr.Nam's method or fragment removal. 4. In level IV fractures, open reduction and internal fixation is recommended 5. Although there was a higher complication rate depending on the degree of deviation, there was no correlation between the degree of deviation and development of complications in each level of fracture 6. Because the complication rate was higher in cases of condylar resorption, vertical dimension loss, and alteration of condylar head position, we must make an effort to prevent such complications during treatment

  • PDF

Evaluation of Train Running Safety for Direct Fixation Concrete Track on Light Rapid Transit (경전철 직결식 콘크리트 궤도구조의 열차주행안전성 평가)

  • Choi, Jung-Youl;Kim, Jun-Hyung;Chung, Jee-Seung;Lee, Sun-Gil
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.5
    • /
    • pp.41-46
    • /
    • 2017
  • The coefficient of derailment and the rate of wheel load reduction were used as the index of train running safety that was directly affected the train derailment safety. In aspects of track, the train running safety depends on the complex interaction between wheel and rail, and the track-vehicle conditions (i.e., the curvature, cant, track system, vehicle speed and the operation conditions, etc). In this study, the relationship between the train running safety and the track curvature and vehicle speed for direct fixation concrete tracks currently employed in Korean light rapid transit was assessed by performing field tests using actual vehicles running along the service lines. The measured dynamic wheel load, lateral wheel load and lateral displacement of rail head were measured for same train running on four tested tracks under real conditions, which included curved and tangent tracks placed on the tunnel and bridge, thus increasing the train speed by approximately maximum design speed of each test site. Therefore, the measured dynamic track response was applied to the running safety analysis in order to evaluate the coefficient of derailment, the rate of wheel load reduction and the track gauge widening at each test site, and compare with the corresponding Korean train running safety standard. As the results, the lateral track response of direct fixation concrete track appeared to increase with the decreased track curvature; therefore, it was inferred that the track curvature directly affected the train running safety.

Isocenter Reproducibility with Mask Fixation System in Stereotactic Radiosurgery (정위 마스크 시스템을 사용한 방사선수술시 회전중심점의 재현성)

  • 이동준;손문준;이기택;최찬영;황금철;황충진
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.135-138
    • /
    • 2002
  • Fractionated stereotactic radiosurguy (FSRS) requires precise and reproducible patient set up. For these reasons non-invasive mask fixation methods have been used in Linac based FSRS. In this study, we measured and assessed the isocenter reproducibility using a commercial head mask fixation system based on thermoplastic materials. For the verification and the measurement of isocenter deviation a special acrylic brain phantom was designed. The designed phantom has 22 vertical rods and each rod has different lengths. At the end of the 8 rods, the monochromic film is attached and irradiated due to planned target position. Deviations of isocenter were measured separately for each direction. The mean deviation showed 0.4 mm in longitudinal direction, 0.1 mm in the lateral direction, 0.1 mm in the anterior-posterior direction of the treatment couch. The data demonstrates the high accuracy and reproducibility. This study reinforces previous literature published.

  • PDF

Fracture and dislocation of the four lateral metatarsophalangeal joints - A case report (외측 4개 중족 족지 관절의 골절-탈구 - 증례보고 -)

  • Yim, Soo-Jae
    • Journal of Korean Foot and Ankle Society
    • /
    • v.4 no.1
    • /
    • pp.19-22
    • /
    • 2000
  • Fracture and dislocation of the four lateral metatarsal head and neck at the metatarsophalangeal joint, which may be associated with a hyperextension force, axial load, and additional rotating force, has rarely been reported. The patient was a 32-year-old man who sustained the injury in a motor vehicle accident. Manual reduction was easily performed but maintenance of reduction was difficult, due to the associated fractures of the metatarsal necks. Thus percutaneous internal fixation with Kirshner's wires was required.

  • PDF

Pathogenesis of the Post-Thyroidectomy Dysphonia (갑상선 절제술 후 발성 장애의 병인)

  • Park, Jun Hee;Do, Nam Yong
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.26 no.1
    • /
    • pp.16-20
    • /
    • 2015
  • Post-thyroidectomy dysphonia occurs very frequently. Causes of dysphonia include recurrent laryngeal nerve (RLN) or external branch of superior laryngeal nerve (EBSL) injury, intubation, laryngotracheal fixation and other causes. Patients commonly characterized hoarseness or their voice impairment inability to short or sing and loss of loudness. Although complete recovery can be expected mostly in 3 months without obvious nerve injury, dysphonia lowers patients quality of life. The present review discuss the very kinds of causes of post-thyroidectomy dysphonia.

  • PDF

Bow Hunter's Stroke Caused by a Severe Facet Hypertrophy of C1-2

  • Chough, Chung-Kee;Cheng, Boyle C.;Welch, William C.;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.2
    • /
    • pp.134-136
    • /
    • 2010
  • Bow hunter's stroke is a rare symptomatic vertebrobasilar insufficiency in which vertebral artery (VA) is mechanically occluded during head rotation. Various pathologic conditions have been reported as causes of bow hunter's stroke. However, bow hunter's stroke caused by facet hypertrophy of C1-2 has not been reported. A 71-year-old woman presented with symptoms of vertebrobasilar insufficiency. Spine computed tomography showed massive facet hypertrophy on the left side of C1-2 level. A VA angiogram with her head rotated to the right revealed significant stenosis of left VA. C1-2 posterior fixation and fusion was performed to prevent serious neurologic deficit from vertebrobasilar stroke.