• Title/Summary/Keyword: Head Vibration

Search Result 334, Processing Time 0.029 seconds

A Numerical Study of New Vehicle Hydraulic Lift Activation by a Magneto-rheological Valve System for Precise Position Control (정밀 위치 제어를 위해 MR 밸브 시스템을 활용한 차량 유압 리프트에 대한 수치해석적 고찰)

  • Lee, TaeHoon;Park, Jhin-Ha;Choi, Seung-Bok;Shin, Cheol-Soo;Choi, Ji-Young
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.1
    • /
    • pp.28-35
    • /
    • 2017
  • Recently, conventional hydraulic car lift systems face the technological limitations due to a lack of height control. The demand for height controllability is required in many tasks such as wheel alignment, and requires compensation for the structural deformation of the lift caused by irregular load distribution. In order to resolve this limitation of the conventional car lift, in this work, a new type of a hydraulic vehicle lift using a magneto-rheological (MR) valve system is proposed and analyzed. Firstly, the dynamic model of vehicle lift is formulated to evaluate control performance; subsequently, an MR valve is designed to obtain the desired pressure drop required in the car lift. Next, a proportional-integral-derivative (PID) controller is formulated to achieve accurate control of the lifting height and then computer simulations are undertaken to show accurate height control performances of the proposed new car lift system.

Chaff-outlet Grain Loss of Head-feed Combine -Changes in chaff-outlet gram loss on the variety, location of chaff-outlet loss control plate and traveling speed- (자탈형(自脱型) 콤바인의 배진손실(排塵損失)에 관(關)한 연구(硏究)(II) -품종(品種), 배진조절판(排塵調節板)의 위치, 작업속도(作業速度)가 배진손실량(排塵損失量)에 미치는 영향-)

  • Chung, C.J.;Choe, J.S.;Choi, Y.S.;Chung, S.I.
    • Journal of Biosystems Engineering
    • /
    • v.15 no.4
    • /
    • pp.310-318
    • /
    • 1990
  • The amount of grain loss incurred during harvesting operation through the chaff-outlet of combine may not be negligible. To minimize this grain loss and optimize condition of combining, it may be necessary that the amout of chaff-outlet loss dependent on varying crop condition is to be estimated as exactly as possible. This study was thus intended to develop the monitor that could indicate the amount of grain lost through the chaff-outlet of combine during haravesting operation, and to find out driving and operating method of combine that could reduce chaff-outlet loss. In the study(1), the frequency distributions of each sound generated by the impact of kernels and chaff, the sound generated by the impact of the mixture of kernels and chaff, and vibration or noise created by the combine engine and other moving parts were investigated experimentally. Based on the results of frequency analyses, the loss monitor was developed which could measure the impact sound of paddy kernels that could be distinguished from those of other threshing products through chaff-outlet, and from vibration or noise created by the combine engine and other moving parts. Also in this study, detecting capability of monitor was tested by comparing the amount of grain lost through chaff-outlet with the amount of grain detected by the loss monitor, and changes in chaff-outlet grain loss on the increase of traveling speed, location of chaff-outlet loss control plate and variety of paddy rice were measured using the loss monitor. The monitor developed in this study efficiently measured the amount of grain lost through the chaff-outlet of combine. It was found that the chaff-outlet grain loss ratio was affected greatly by the variety of paddy rice, the location of chaff-outlet loss control plate and traveling speed of combine.

  • PDF

A Proposal of Output Method of Round Window Stimulation Type Middle Ear Implants using Acoustic Transmission (공기 전도형 출력을 갖는 정원창 자극형 인공중이의 출력방식 제안)

  • Seong, Kiwoong;Lee, KyuYup;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.6
    • /
    • pp.678-684
    • /
    • 2018
  • In order to broaden the indication of middle ear implant, research has been actively conducted on the reverse output method that stimulates the round window. However, it is very difficult to transmit the vibration output effectively because the indivisual anatomical difference of the round window niche is very large and also the visual field is not secured even by a skilled otolaryngologic surgeon. In this paper, we propose a new reverse stimulation method of middle ear implants that transmits energy to the inner ear by using air as a medium. This can compensate for the disadvantages of the conventional method of transmitting vibration energy and minimizes the energy transfer efficiency interference due to the combination of the excitation point and the output device. It was shown that forward and backward transfer characteristics were obtained by cadaveric experiments, and it was shown that it can overcome the acoustical impedance of high round window and transmit energy to inner ear. The receiver, which is the output device of the conventional hearing aids, can generate a constant volume velocity, so it can have a high output at a limited volume, such as a round window niche. So, suggested method can overcome the high acoustical impedance of the round window and deliver acoustic energy to the inner ear.

Reproductive Function of the Body and Tail Undulations of Hynobius leechii (Amphibia: Hynobiidae): A Quantitative Approach

  • Kim, Ja-Kyeong;Lee, Jung-Hyun;Ra, Nam-Yong;Lee, Heon-Ju;Eom, Jun-Ho;Park, Dae-Sik
    • Animal cells and systems
    • /
    • v.13 no.1
    • /
    • pp.71-78
    • /
    • 2009
  • To clarify the reproductive function of vibration signals in Hynobius, which has externally fertilized eggs, we quantitatively analyzed the body and tail undulations of male Korean salamanders (Hynobius leechii) in sixteen mating events. One large and one small male, and one female were used in each mating event. We analyzed behaviors recorded over a total of 3 hrs for each mating event; 2 hrs before and 1 hr after female's oviposition. Males touched females using their snouts or body trunk throughout the entire mating periods, but females touched males increasingly more after approximately 1 hr before oviposition. Males conducted body undulations more than 50 times per 10 minutes at a mean frequency of 0.64 Hz. Large males conducted more body undulations than small males, particularly on the tree twig where females attached their egg sacs. Males responded to other males' body undulation throughout the mating period by orienting their head towards, approaching, and touching the undulating male. Females only responded for about 10-20 min before ovipositing, and most responses were directed to the large male's body undulation. Males conducted tail undulations 3.0 times per 10 min at a mean frequency of 1.7 Hz and most tail undulations occurred after one male bit the other male. These results suggest that body undulations function in both male-female and male-male interactions, while tail undulations mainly functions in male-male competition. Also, male H. leechii appear to actively attract females, while females respond to the males only at times close to oviposition.

Characterization of Acousto-ultrasonic Signals for Stamping Tool Wear (프레스 금형 마모에 대한 음-초음파 신호 특성 분석)

  • Kim, Yong-Yun
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.4
    • /
    • pp.386-392
    • /
    • 2009
  • This paper reports on the research which investigates acoustic signals acquired in progressive compressing, hole blanking, shearing and burr compacting process. The work piece is the head pin of the electric connector, whose raw material is the preformed steel bar. An acoustic sensor was set on the bed of hydraulic press. Because the acquired signals include the dynamic characteristics generated for all the processes, it is required to investigate signal characteristics corresponding to unit process. The corresponding dynamic characteristics to the respective process were first studied by analyzing the signals respectively acquired from compressing, blanking and compacting process. The combined signals were then periodically analyzed from the grinding to the grinding in the sound frequency domain and in the ultrasonic wave. The frequency of around 9 kHz in the sound frequency domain was much correlated to the tool wear. The characteristic frequency in the acoustic emission domain between 100 kHz and 500 kHz was not only clearly observed right after tool grinding but its amplitude was also related to the wear. The frequency amplitudes of 160 kHz and 320 kHz were big enough to be classified by the noise. The noise amplitudes are getting bigger, and their energy was much bigger as coming to the next regrinding. The signal analysis was based on the real time data and its frequency spectrum by Fourier Transform. As a result, the acousto-ultrasonic signals were much related to the tool wear progression.

Acoustical Similarity for Small Cooling Fans Revisited (소형 송풍기 소음의 음향학적 상사성에 관한 연구)

  • 김용철;진성훈;이승배
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.196-201
    • /
    • 1995
  • The broadband and discrete sources of sound in small cooling fans of propeller type and centrifugal type were investigated to understand the turbulent vortex structures from many bladed fans using ANSI test plenum for small air-moving devices (AMDs). The noise measurement method uses the plenum as a test apparatus to determine the acoustic source spectral density function at each operating conditions similar to real engineering applications based on acoustic similarity laws. The characteristics of fans including the head rise vs. volumetric flow rate performance were measured using a performance test facility. The sound power spectrum is decomposed into two non-dimensional functions: an acoustic source spectral distribution function F(St,.phi.) and an acoustic system response function G(He,.phi.) where St, He, and .phi. are the Strouhal number, the Helmholtz number, and the volumetric flow rate coefficient, respectively. The autospectra of radiated noise measurements for the fan operating at several volumetric flow rates,.phi., are analyzed using acoustical similarity. The rotating stall in the small propeller fan with a bell-mouth guided is mainly due to a leading edge separation. It creates a blockage in the passage and the reduction in the flow rate. The sound power levels with respect to the rotational speeds were measured to reveal the mechanisms of stall and/or surge for different loading conditions and geometries, for example, fans installed with a impinging plate. Lee and Meecham (1993) studied the effect of the large-scale motions like impinging normally on a flat plate using Large-Eddy Simulation(LES) and Lighthill's analogy.[ASME Winter Annual Meeting 1993, 93-WA/NCA-22]. The dipole and quadrupole sources in the fans tested are shown closely related to the vortex structures involved using cross-correlations of the hot-wire and microphone signals.

  • PDF

Controller Design of Piezoelectric Milliactuator for Dual Stage System (이중 구동 시스템을 위한 압전 밀리엑추에이터의 제어기 설계)

  • Eo-Jin, Hong;No-Cheol, Park;Hyun-Seok, Yang;Young-Pil, Park
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.12
    • /
    • pp.965-971
    • /
    • 2003
  • To reach high areal density, less track pitch is expected and more servo bandwidth is required. One approach to overcoming the problem is by using dual stage servo system. For this system. we have suggested new milliactuator based on the shear mode of piezoelectric elements to drive the head suspension assembly. In this paper, we introduce milliactuator and controller design method, PQ method. PQ method reduces the controller design problem for DISO (dual-input/single-output) systems to two standard controller design problems for SISO ( single-input/single-output) problems. The first part of PQ method directly addresses the issue of actuator output contribution, and the second part allows the use of traditional loop shaping to achieve the overall system performance. This paper shows how to employ the PQ method to meet aggressive close-loop performance specifications for a disk drive system with a VCM and piezoelectric milliactuator.

Research on the characteristics of noise exposure on worker wearing acoustic devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.808-813
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset Noise exposure measurements of 17 operators were performed in 7 call centers and Head and Torso Simulator method in compliance with the ISO Standard 11904-2 was used for the measurement of noise transmitted from the headset Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of Pearson Correlation Analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

  • PDF

Research on the Characteristics and Measures of Noise Exposure on Worker Wearing Acoustic Devices (음향도구 착용 근로자의 소음노출 실태에 관한 연구)

  • Kim, Kab-Bae;Yoo, Kye-Mook;Lee, In-Seop;Chung, Kwang-Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.7
    • /
    • pp.615-621
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset. Noise exposure measurements of 17 operators were performed in 7 call centers and head and Torso simulator method in compliance with the ISO standard 11904-2 was used for the measurement of noise transmitted from the headset. Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of pearson correlation analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

Application technique on thrust jacking pressure of shield TBM in the sharp curved tunnel alignment by model tests (축소모형실험을 통한 급곡선 터널에서의 Shield TBM 추진 압력 적용 기술에 대한 연구)

  • Kang, Si-on;Kim, Hyeob;Kim, Yong-Min;Kim, Sang-Hwan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.19 no.2
    • /
    • pp.335-353
    • /
    • 2017
  • This paper presents the application technique on thrust jacking pressuring of shield TBM in the sharp curved tunnel alignment by model tests. Recently, the application of shield TBM method as mechanized tunnelling is increasing to prevent the vibration and noise problems, which can be occurred in the NATM in the urban area in Korea. However, it is necessary to plan the sharp curved tunnel alignment in order to avoid the building foundation and underground structures, to develop the shield TBM operation technique in the shape curved tunnel alignment. Therefore, the main operation parameters of shield TBM in the curved tunnel alignment are reviewed and analyzed based on the case study and analytical study. The results show that the operation of shield jacking force system is the most important technique in the shape curved tunnel alignment. The simplified scaled model tests are also carried out in order to examine the ground-shield TBM head behaviour. The earth pressures acting on the head of shield TBM are investigated according to two different shield jacking force systems (uniform and un-uniform pressure) and several articulation angles. The results obtained from the model tests are analysed. These results will be very useful to understand the shield TBM head interaction behaviour due to the shield jacking operation technique in the shape curved tunnel alignment, and to develop the operation technique.