• Title/Summary/Keyword: Head Speed

Search Result 882, Processing Time 0.028 seconds

Hybrid ABS based Inter-Cell Scheduling Algorithms for QoS Improvement of Heterogeneous Networks (이기종 네트워크의 QoS 향상을 위한 Hybrid ABS기반 셀 간 스케줄링 알고리즘)

  • Kim, Myung-Dong;Seong, Hyeon-Kyeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.17 no.1
    • /
    • pp.1-9
    • /
    • 2016
  • In this paper, for the improvement of quality of service(QoS) performance of heterogeneous networks, multi-cell scheduling is proposed. In order to implement the proposed algorithm, for the recognition of the impact on the throughput performance of users, macro-pico-cells that form distributed architecture were proposed. In operating heterogeneous networks, considering the centralized structure, a macro-RRH(Remote Radio Head) deployment scenario was proposed. For interference mitigation of the proposed system, by applying the optional sub-frame, through CQI(Channel Quality Indicator) measurement for each sub-frame period, constraint conditions were measured according to system situations. For the simplification, the pattern of the same ABS muting was assumed. In the above two multi-cell environments, the algorithm of high-speed load balancing maintenance was proposed.

The change of ankle of plantar pressure and range of motion joint according to treadmill gradients (트레드밀보행 시 경사도에 따른 족저압과 발목관절의 관절가동범위의 변화)

  • Kim, Tae-Ho;Kim, Byoung-Gon
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.14 no.1
    • /
    • pp.39-47
    • /
    • 2008
  • Purpose : The purpose of this study was to investigate the change of the peak plantar pressure distribution under the foot areas and the range of motion (ROM) of ankle joint according to gradients in treadmill gait. Method : Thirty normal subjects (15 male and 15 female) walked on treadmill at three gradient conditions ($0^{\circ}$, $10^{\circ}$, and $15^{\circ}$) in normal speed. The ankle ROM was measured using the CMS70P that is three dimensional analyzer for excursion of ankle ROM, plantar flexion, and dorsi flexion. The peak plantar pressure distribution under the hallux, 1st metatarsal head (MTH) and heel was measured using the F -Scan system with an in-shoe sensor. Data was collected from 9 steps of left sife foot in at each gradient condition while all subjects walked. Result : As the treadmill gradient increased, the excursion of ankle joint was significantly increased (p<.05). Also, plantar flexion and dorsi flexion was significantly increased according to treadmill gradients (p<.05). The peak plantar pressure under the 1st MTH was significantly increased (p<.05) and the peak plantar pressure under the heel was significantly decreased (p<.05) as the treadmill gradient increased. No significant different in the peak plantar pressure under the hallux was observed. Conclusion : This study suggests that physical therapy for patients who have limited ankle ROM should be considered sufficient range of motion for functional ambulation. And individuals that have painful forefoot syndromes, including metatarsalgia, hallux valgus, and plantar ulceration should be careful in walking to uphill, as there is high plantar pressure under the forefoot.

  • PDF

An Effective Cell Scheduling Algorithm for Input Queueing ATM Switch (입력단 큐잉 방식의 ATM 스위치를 위한 효율적 셀 중재 방식에 관한 연구)

  • 김용웅;원상연;박영근
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.1A
    • /
    • pp.122-131
    • /
    • 2000
  • In this paper, we propose a cell scheduling algorithm for input queueing ATM switch. The input queueing architecture is attractive for building an ultra-high speed ATM (Asynchronous Transfer Mode) switch. We proposea WMUCS (Weighted Matrix Unit Cell Scheduler) based on the MUCS which resolves HOL blocking and outputport contention. The MUCS algorithm selects an optimal set of entries as winning cells from traffic matrix (weightmatrix). Our WMUCS differs from the MUCS in generating weight matrices. This change solves the starvationproblem and it reduces the cell loss variance. The performance of the proposed algorithm is evaluated by thesimulation program written in C++. The simulation results show that the maximum throughput, the average celldelay, and the cell loss rate are significantly improved. We can see that the performance of WMUCS is excellentand the cost-effective implementation of the ATM switch using proposed cell scheduling algorithm.

  • PDF

A STUDY ON THE POLYMERIZATION STRESS OF COMPOSITE RESINS (복합레진의 중합수축력에 관한 연구)

  • Kim, Boo-Rang;Choi, Ho-Young;Min, Byung-Soon;Park, Sang-Jin;Choi, Gi-Woon
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.331-341
    • /
    • 1992
  • The purpose of this study was to measure the polymerization contraction stress of two types of composite resins; chemical cured type(Cliarfil F II, Kuraray, Japan) and photo-cured type(Photo-Clearfil Bright, Kuraray, Japan). The stresses of composite resin by contraction measured with specially designed measuring device(Fig. 1). The stresses caused by shrinkage during hardening of specimens were measured according to the type of composite resins, thickness of specimen(0.65, 1.30 and 1.95mm), and ratio of catalyst to base in case of only chemical cured composite resin(0.5, 1.0 and 1.5). As the composite resin specimen shrank on hardening, the load cell recorded force vs time automatically on pen-recorder(Toa, Japan) with a cross-head speed 60mm/hr at 0~10 voltages up to 2 hours. The experiments were conducted in a room maintained at $23{\pm}2^{\circ}C$ and relative humidity $50{\pm}10%$. The results were as follows. 1. The contraction stress during hardening was higher in photo cured composite resin than in chemical cured composite resin. 2. The contraction stress during hardening was increased with thickness of composite resin specimen. 3. In chemical cured composite resin, the polymerization contraction stress was decreased with ratio of catalyst and base. 4. The contraction stress during polymerization was higher in early time after insertion of photo cured composite resin and chemical cured composite resin.

  • PDF

INFLUENCE OF ARTIFICIAL SALIVA CONTAMINATION ON BONDING OF DENTIN ADHESIVES TO DENTIN (인공타액 오염이 수종 상아질접착제와 상아질간의 결합에 미치는 영향)

  • Ryu, Mee-Ae;Yang, Kyu-Ho;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.17 no.2
    • /
    • pp.383-397
    • /
    • 1992
  • The purpose of this study was to evaluate the influence of artificial saliva contamination on bonding of several dentin adhesives to dentin. Sixty - three human molar teeth extracted within a month were used. Each tooth was sectioned longitudinally in a buccolingual direction to obtain 126 specimens. These specimens were randomly divided into three groups and were treated by Scotchbond 2, Gluma and All bond. Each group was subdivided into three subgroups; normal group not contaminated with artificial saliva, contaminated with artificial saliva and dried group, and contaminated with artificial saliva and washed and dried group. Enamel/dentin bonding agent(Dental Adhesive of Scotchbond 2) was applied and light cured on the treated dentin surfaces. Thereafter P - 50 were cured on them, and specimens were stored in $37^{\circ}C$ artificial saliva for 24 hours before measuring shear bond strength. Shear bond strengths were determined using an universal testing machine with cross head speed 1mm/min and SEM examinations were conducted to evaluate the resin - dentin interface and degree of penetrating resin string into the dentinal tubules. The following results were obtained. 1. Normal groups not contaminated with artificial saliva showed greater shear bond strength than any other group contaminated with artificial saliva(P<0.01). 2. The shear bond strengths showed no significant difference between washed groups with distilled water and not washed groups after contamination with artificial saliva(P>0.05). 3. In normal groups, the shear bond strength of A group was significantly greater than in any other group(P<0.01). 4. In Sand G groups, fractures after shear bond strength tests occured adhesively on resintooth interface in all specimens. But in A groups, fracture of the normal group occured cohesively in dentin and fracture of the contaminated groups occured adhesively and cohesively. 5. On SEM examination, the number of resin strings penetrated into dentinal tubules were the greatest in normal groups, followed by, in descending order, washed groups and not washed groups after contamination with artificial saliva.

  • PDF

Changes of Impact Variables by the Change of Golf Club Length (골프 클럽에 따른 타격자세의 변화)

  • Sung, Rak-Joon
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.4
    • /
    • pp.181-189
    • /
    • 2005
  • To know the proper impact posture and changes for the various clubs, changes of impact variables according to the change of golf club length was investigated. Swing motions of three male low handicappers including a professional were taken using two high-speed video cameras. Four clubs iron 7, iron 5, iron 3 and driver (wood 1) were selected for this experiment. Three dimensional motion analysis techniques were used to get the kinematical variables. Mathcad and Kwon3D motion analysis program were used to analyze the position, distance and angle data in three dimensions. Major findings of this study were as follows. 1. Lateral position of the head remained more right side of the target up to 3.5cm compared to the setup as the length of the club increased. 2. Left shoulder raised up to 5cm and right shoulder lowered up to 2.5cm compared to setup. The shoulder line opened slightly (maximum 11 degrees) to the target line. 3. Forward lean angle of the trunk decreased up to 4 degrees (more erected) compared to setup. 4. Side lean angle of the trunk increased compared to setup and increased up to 16 degrees as the club length increased. 5. The pelvis moved to the target line direction horizontally and opened up to 31 degrees. Right hip moves laterally to the grip position at the setup. 6. Flexion of the left leg maintained almost constantly but the right leg flexed up to 11 degrees compared to setup. 7. Left arm is straightened but the right arm flexed about 20degrees compared to straight. 8. Center of the shoulders were in front of the knees and toes of the feet. 9. Hands moved to the left (8.7cm), forward (5.7cm) and upward (11.6cm) compared to the setup. This is because of the rotation of pelvis and shoulders. 10. Shaft angle to the ground was smaller than the lie angle of the clubs but it increased close to the lie of the clubs at impact.

The Application of Qualitative Evaluation for Golf Swills field Lesson (골프스윙 현장지도를 위한 정성적 평가 적용)

  • Yu, Seung-Won
    • Korean Journal of Applied Biomechanics
    • /
    • v.19 no.2
    • /
    • pp.323-336
    • /
    • 2009
  • The purpose of the current study was to research scientific basis and necessity of supplementary materials for field lesson out of golf swing teaching methods. As the subject of study, skillful tour pro golfers were chosen to reinterpret field lesson results for driver swing from the viewpoint of kinematics. In addition, through precise analysis, this study developed a case to verify the validity and error of field lesson. As a result, field lesson showed a slight difference among qualitative evaluation of kinematical analysis of techniques, subjects of study, and items. Accordingly, there was a little difference between two methods in view of evaluation of errors that 5 subjects of the study have shown. However, there was a significant difference in compensation to prevent causes of error and errors. Based on instructor's experience most errors could be evaluated. Therefore, feedback for error correction based on instructor's experience showed a significant difference from qualitative evaluation of kinematical analysis of techniques. In conclusion, the following are required for correct golf swing lesson; instant feedback through field lesson and qualitative evaluation of kinematical analysis of techniques to determine fundamental causes correctly.

An Analysis on Kinematically Contributing Factors at Impact of Forehand Drive Motion in Squash (스쿼시 포핸드 드라이브 동작의 임팩트시 운동학적 주요요인 분석)

  • Lee, Kyung-Il;Lee, Hee-Kyung
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.1
    • /
    • pp.29-39
    • /
    • 2007
  • This study were obtained elapsed time phase-by-phases, displacement, user angle, velocity and angular velocity to analyse kinematically contributing factors at impact of forehand drive motion, on targeting three male players. The results of the study were presented as follows; In the forehand drive swing, the elapsed time by phases was a total of .52 seconds: .30 seconds from backswing to impact and .22 seconds from impact to follow-through, Considering the mean change in locations of COM of each(part$\rightarrow$body segment) at impact, racket head, left shoulder, right wrist and left hip, the left-right directions(X-axis) were showm to be each $.61{\pm}.03$, $1.19{\pm}.08$, $.66{\pm}.03$, $.94{\pm}.06$, and $.45{\pm}.03m$. The displacement differences of COM of each body segment were shown to be -.57, -.05, -.33, and .16m. For the vertical direction(Z-axis), the center of mass was lowest at impact and highest at E3. For the displacement of the right wrist on the left hip, the right wrist moved to .82m to the lower direction without change in the locations of the hip from E1 from E2. When the left hip moved .02m from E2 to E3, the right wrist moved .7m in the upper direction. In respect to the velocity of each body segment, the hip and the shoulder joint accelerated and then the wrist followed. Then the right wrists of all the subjects and their racket heads showed maximum speed, and an effective swing was observed. At the angle of each part, the angle of the right wrist was the smallest at the backswing and the largest at the moment of the impact. Then it increased gradually in the follow-through section. In respect of angular velocity for subject A, the hip moved and the largest change occurred. Immediately before the impact, the subject made a swing using his right wrist, his hip, and the shoulder joint, showing the maximum value, which was judged to be effective.

A STUDY ON THE RESIN IMPREGNATION AND SHEAR BOND STRENGTH BY VARIOUS DENTIN CONDITIONERS (수종 상아질 표면처리제에 의한 레진 침투 및 전단결합강도에 관한 연구)

  • Lee, Kwang-Won;Lee, Myung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.15 no.1
    • /
    • pp.201-216
    • /
    • 1990
  • A variety of surface pre-treatments have been advocated to prepare the dentin prior to placement of a bonding agent. The purpose of this study was to evaluate the effect of various dentin conditioners upon the degree of resin impregnation to the dentinal tubules and the shear bond strength of a new dentinal bonding agent (Scotchbond 2) used in conjunction with a visible light cured composite (Silux). The healthy eighty human molars extracted due to periodontal or orthodontic reasons were used and randomly divided into five groups. All the grinded dentin surfaces were conditioned with 3% $H_2O_2$, Cavity Cleanser (Columbus/Bayer), Dentin Conditioner (GC Inter. Corp.), Scotchprep (3M Co.) according to the manufacturer's directions. The specimens were then demineralized in 10% HCl for 20 sec. and 24 hrs. in order to observe the resin tags in Hitachi X-450 scanning electron microscope at 25KV. Also, shear strengths were obtained using an Instron Testing Machine with a cross head speed of 1 mm/min. The following results were obtained ; 1. In group treating with Dentin Conditioner and Scotchprep, the resin strings were formed on most of the surfaces and penetrated more than $50{\mu}m$ into the tubules. 2. The inner surface of resin treated with Cavity Cleanser, indicating the resin strings formed partly and penetrated about in depth of $30{\mu}m$. 3. In control and experimental group treated with 3% $H_2O_2$, the resin tags were not formed, if any, penetrated shortly. 4. Shear bond strengths in groups treating with Dentin Conditioner and Scotchprep were statistically significant increase than with 3% $H_2O_2$. (P<0.01). 5. The Scotchprep treatment group was significantly higher in shear strength than groups treated with no conditioning and Cavity Cleanser.(P<0.01) 6. Shear bond strengths evaluated were gradually increase in proportion to the tag length of resin impregnation.

  • PDF

AN EXPERIMENTAL STUDY OF THE EFFECT OF THE VARIOUS ANTISEPTIC STRORAGE SOLUTIONS ON PHYSICAL PROPERTIES OF GUTTA-PERCHA CONE (수종 소독제가 Gutta-percha cone의 물리적 성질에 미치는 영향에 관한 실험적 연구)

  • Lee, Mi-Young;Park, Dong-Soo
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.209-215
    • /
    • 1991
  • The propose of this study was to evaluate the effect of the variuos antiseptic solutions and distilled water on physical properties of endodontic gutta-percha cone. The antiseptic solutions were 70% isoprophyl alcohol, 5% NaOCl and 2.5% NaOCl, as control gutta-percha cones, did not stored antiseptic solution was used. Observation periods were 1, 5, 10, 20, and 30 days. In each group,. the 15 gutta-percha cones used. A tensile strength and elongation rate measurements were performed with Instron (Instron 4501), cross - head speed was set 10 inch / min. The data were statistically analyzed and the results were as followed. 1. The tensile strength of the gutta-percha cones, stored in distilled water, were slightly decreased (p<0.05). Elongation rate was not significantly different 2. The tensile strength of the gutta-percha cones, stored in 70% isopropyl alcohol, were increased (p<0.01) except 1 day group. 3. The tensile strength of the gutta-percha cone, stored in 2.5% NaOCl, were decreased (p<.0.05). Elongation rate significantly decreased (p<0.01). 4. The tensile strength of the gutta-percha cone, stored in 5% NaOCl, were decreased (p<0.05). Elongation rate significantly decreased (p<0.01). These results showed that the changes of physical properties (tensile strength and elongation rate) in gutta-percha cone were developed after a day' when gutta-percha cone were stored at 70% isopropyl alcohol, 2.5% or 5% NaOCl. So, It was concluded that gutta-percha cone must have been used at least within one day, when they were stored at the above antiseptics. I thought that the study of substantial effects on endodontic treatment due to changes of physical properties in gutta-percha cone will be needed.

  • PDF