• Title/Summary/Keyword: Head CT

Search Result 553, Processing Time 0.039 seconds

CT in Penetrating Wooden Foreign Bodies of Head and Neck (공기음영으로 오인될 수 있는 두경부 영역의 관통성 나무이물에 대한 컴퓨터 전산화 단층촬영의 의의)

  • 오승철;김찬우;박병훈;강인봉;김선태;장일환;차흥억;이선규
    • Korean Journal of Bronchoesophagology
    • /
    • v.4 no.1
    • /
    • pp.142-147
    • /
    • 1998
  • Retained wooden foreign bodies following penetrating trauma are a difficult diagnostic problem. However, penetrating wooden foreign bodies of head and neck have the potential for misinterpretation or failure to detect such foreign bodies on CT. Given the likelihood that such a miss will result in an abscess or neurovascular injury, we present the method with higher window settings, they had a higher attenuation with a unique striated internal architecture and different Hounsfield numbers readily differentiate air and non-air hypodense material such as fat, or possibly wood. Being aware of the potential appearance of wood, we may also find CT useful in excluding small retained fragments in postoperative patients with persistent symptoms. This article presents two cases in which wooden foreign bodies of head and neck were present with CT evaluation.

  • PDF

Accuracy of F-18 FDG PET/CT in Preoperative Assessment of Cervical Lymph Nodes in Head and Neck Squamous Cell Cancer: Comparison with CT/MRI (두경부 편평상피암 환자에서 수술 전 경부림프절 전이 평가에 대한 F-18 FDG PET/CT의 정확도: CT/MRI와의 비교)

  • Choi, Seung-Jin;Byun, Sung-Su;Park, Sun-Won;Kim, Young-Mo;Hyun, In-Young
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.6
    • /
    • pp.309-315
    • /
    • 2006
  • Purpose: Accurate evaluation of cervical lymph node (LN) metastasis of head and neck squamous cell canter (SCC) is important to treatment planning. We evaluated the diagnostic accuracy of F-18 fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for the detection of cervical LN metastasis of head and neck SCC and performed a retrospective comparison with CT/MRI findings. Materials & Methods: Seventeen patients with pathologically proven head and neck SCC underwent F-18 FDG PET/CT and CT/MRI within 4 week before surgery. We recorded lymph node metastases according to the neck level system of imaging-based nodal classification. F-18 FDG PET/CT images were analyzed visually for assessment of regional tracer uptake in LN. We analyzed the differences in sensitivity and specificity between F-18 FDG PET/CT and CT/MRI using the Chi-square test. Results: Among the 17 patients, a total of 123 LN levels were dissected, 29 of which showed metastatic involvement. The sensitivity and specificity of F-18 FDG PET/CT for detecting cervical LN metastasis on a level-by-level basis were 69% (20/29) and 99% (93/94). The sensitivity and specificity of CT/MRI were 62% (18/29) and 96% (90/94). There was no significant difference in diagnostic accuracy between F-18 FDG PET/CT and CT/MRI. Interestingly, F-18 FDG PET/CT detected double primary tumor (hepatocellular carcinoma) and rib metastasis, respectively. Conclusion: There was not statistically significant difference of diagnostic accuracy between F-18 FDG PET/CT and CT/MRI for the detection of cervical LN metastasis of head and neck SCC. The low sensitivity of F-18 FDG PET/CT was due to limited resolution for small metastatic deposits.

A Study on Characteristic of Image Quality according to CT Table Height in Computed Tomography (컴퓨터단층촬영 검사 시 테이블 높이에 따른 화질 특성에 관한 연구)

  • Ki-Won Kim;Jung-Whan Min;Sang-Sun Lee;Young-Bong Lee;Ki-Jong Lee;Han-Sol Park;Joo-Young Oh
    • Journal of radiological science and technology
    • /
    • v.46 no.4
    • /
    • pp.295-301
    • /
    • 2023
  • In addition to protocol adjustments during CT examinations, the height of the CT table can also affect image quality. Therefore, this study aimed to investigate the change in image quality depending on the height of the table in brain CT, which accounts for a large proportion of CT examinations, by measuring signal to contrast to noise ratio (CNR) and noise power spectrum (NPS) using the head phantom and evaluating them. The head phantom images were acquired using Philips Brilliance iCT 256. When the image was acquired, the table height was adjusted to 815, 865, 915, 965, 1015, and 1030 mm, respectively, and each scan was performed 3 times for each height. The CNR result showed the highest value at 965 mm, which is the height adjacent to the center of the head phantom. NPS showed the lowest NPS at 915 mm, the center of the head phantom in the low frequency region. From these results, it can be seen that the height of the table in CT examination is closely related to the image quality, and it can be seen the characteristics of image quality according to CT table through quantitative evaluation methods such as CNR and NPS.

Clinical Significance of FDG PET-CT Scan at 12 Weeks after Curative Radiation Therapy in Patients with Head and Neck Cancer (두경부암 환자에서 근치적 방사선치료 후 12주 시행한 양전자방출촬영의 임상적 중요성에 대한 연구)

  • Kim, Young-il;Kim, Jun-sang;Kwon, Jeanny;Kim, Sup;Seo, Youngduk;Koo, Bon-seok;Chang, Jae-won;Cho, Moon-June
    • Korean Journal of Head & Neck Oncology
    • /
    • v.37 no.1
    • /
    • pp.17-22
    • /
    • 2021
  • Background/Objectives: To evaluate clinical significance of FDG PET-CT for detection of residual cancer cells after curative radiation therapy or chemoradiotherapy for patients with squamous cell carcinoma (SCC) of Head and Neck Materials & Methods: A retrospective analysis of patients with SCC of Head and neck with curative radiotherapy or chemoradiotherpy between June 2011 and Jan. 2019 was performed. Sixty patients were treated with Intensity-modulated radiotherapy (IMRT). The Metabolic responses were evaluated on the post-treatment FDG PET-CT at 12 weeks after curative radiotherapy completion. Results: Median follow up was 51.5 months (3-102). The overall survival (OS), disease free survival (DFS), local control rate (LCR), and Distant metastasis free survival (DMFS) at 5 years were 80.5%, 80.1%, 87.7% and 89.1%. Metabolic CR was found in 43 (71.7%) and partial metabolic response (PR) was noted in 17 (14.6%). Metabolic CR was significantly correlated with OS, DFS, LCR, and DMFS. On multivariate analysis, Metabolic CR remained significant for DFS and LCR. Conclusion: Metabolic CR on post-radiotherapy FDG PET-CT is highly predictive of increased DFS and LCR in patients with head and neck cancer.

Granuloma Resulting from the Cervical Metallic Plate, Masquerading as Posterior Pharyngeal Wall Cancer (하인두 후벽암으로 오인된 경추 내고정 금속판 삽입 후 발생한 육아종 1예)

  • Kim, Seung-Woo;Kim, Young-Bae;Sah, Dae-Jin
    • Korean Journal of Head & Neck Oncology
    • /
    • v.27 no.2
    • /
    • pp.218-221
    • /
    • 2011
  • The anterior approach to the cervical spine surgery is associated with possible complications such as dysphagia, hoarseness and granuloma formation etc. Because of orthopedic metallic plates, the increasing or focal uptake pattern may be demonstrated in $^{18}F$-FDG PET/CT scan. A 67-year-old-man came to our department, complained of dysphagia during the 4 months. He underwent cervical spine surgery three years ago. The CT and MRI findings mimicked typical posterior pharyngeal wall cancer with cervical metastasis. Furthermore, the SUV in $^{18}F$-FDG PET/CT was 10.3. But he was finally diagnosed as a granuloma resulting from the metallic cervical implants. The clinical correlation and medical history should be taken into account to avoid false-positive findings in PET/CT and to avoid many erroneous diagnostic pathways.

A Study on 3d Reconstruction and Simulated Implantation of Human Femur Using Consecutive CT-Images (연속된 CT-Image를 이용한 고관절 3d 형상의 재구성 및 Simulated Implantation System 구축에 관한 연구)

  • 민경준;김중규;최재봉;최귀원
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.2
    • /
    • pp.155-164
    • /
    • 1999
  • In this paper, the prototype of SIS(Simulated Implantation System) for human femoral head is introduced. SIS is a software which carries on a virtual femoral head replacement surgery including 3d visualization as well as various numeric analyses between a patient's femur and artificial femur through certain stages of the image processing and of the computer graphics. Also, processes required after acquiring consecutive CT-images and projected image of an artificial femur are discussed, and the corresponding results including prototype of SIS are given.

  • PDF

Effective Dose Determination From CT Head & Neck Region (두경부(Head & Neck) CT 검사 시 장기의 유효선량 측정)

  • Yun, Jae-Hyeok;Lee, Kwang-Weon;Cho, Young-Ki;Choi, Ji-Won;Lee, Joon-Il
    • Journal of radiological science and technology
    • /
    • v.34 no.2
    • /
    • pp.105-116
    • /
    • 2011
  • In this study, we present the measurements of effective dose from CT of head & neck region. A series of dose measurements in anthropomorphic Rando phantom was conducted using a radio photoluminescent glass rod dosimeter to evaluate effective doses of organs of head and neck region from the patient. The experiments were performed with respect to four anatomic regions of head & neck: optic nerve, pons, cerebellum, and thyroid gland. The head & neck CT protocol was used in the single scan (Brain, 3D Facial, Temporal, Brain Angiography and 3D Cervical Spine) and the multiple scan (Brain+Brain Angiography, Brain+3D Facial, Brain+Temporal, Brain+3D Cervical spine, Brain+3D Facial+Temporal, Brain+3D Cervical Spine+Brain Angiography). The largest effective dose was measured at optic nerve in Brain CT and Brain Angiography. The largest effective dose was delivered to the thyroid grand in 3D faical CT and 3D cervical spine, and to the pons in Temporal CT. In multiple scans, the higher effective dose was measured in the thyroid grand in Brain+3D Facial, Brain+3D Cervical Spine, Brain+3D Facial+Temporal and Brain+3D Cervical Spine+Brain Angiography. In addition, the largest effective dose was delivered to the cerebellum in Brain CT+Brain Angiography CT and higher effective dose was delivered to the pons in Brain+Temporal CT. The results indicate that in multiple scan of Brain+3D Cervical Spine+Brain Angiography, effective dose was 2.52 mSv. This is significantly higher dose than the limitation of annual effective dose of 1 mSv. The effective dose to the optic nerve was 0.31 mSv in Brain CT, which shows a possibility of surpassing the limitation of 1 mSv by furthre examination. Therefore, special efforts should be made in clinical practice to reduce dose to the patients.

Estimate of Radiation Doses in MDCT Using Patient Weight (MDCT 검사에서 환자 체중을 이용한 선량 평가)

  • Kwon, Seong-Ohk;Dong, Kyung-Rae;Kweon, Dae-Cheol;Goo, Eun-Hoe;Choi, Ji-Won;Chung, Woon-Kwan
    • Progress in Medical Physics
    • /
    • v.21 no.3
    • /
    • pp.246-252
    • /
    • 2010
  • The purpose of this study provides measurements of radiation dose from MDCT of head, chest, abdomen and pelvic examinations. A series of dose quantities that are measured of patient weight to compare the dose received during MDCT examinations. Data collected included: weight together with CT dose descriptors, volume CT dose index (CTDIvol) and dose length product (DLP). The effective dose was also estimated and served as collective dose estimation data. Data from 1,774 adult patients attending for a CT examination of the head (n=520) or chest (n=531) or abdomen (n=724) was obtained from spiral CT units using a same CT protocol. Mean values of CTDIvol was a range of 48.6 mGy for head and 6.9, 10.5 mGy for chest, abdomen examinations, respectively. And mean values of DLP was range of 1,604 $mGy{\cdot}cm$ for head, 250 $mGy{\cdot}cm$ for chest, 575 $mGy{\cdot}cm$ for abdomen examinations, respectively. Mean effective dose values for head, chest, abdominal CT were 3.6, 4.2, and 8.6 mSv, respectively. The degree of CTDIvol and DLP was a positive correlation with weight. And there was a positive correlation for weight versus CTDIvol ($r^2$=0.62), DLP ($r^2$=0.694) in chest. And head was also positive correlation with weight versus CTDIvol ($r^2$=0.691), DLP ($r^2$=0.741). We conclude that CTDIvol and DLP is an important determinant of weight within the CT examinations. The results for this study suggest that CT protocol should be tailored according to patient weight.

Utility of FDG PET-CT Scans on Nodal Staging of Squamous Cell Carcinoma in the Oral Cavity and Oropharynx (구강 및 구인두 편평상피암종의 림프절 전이에 대한 PET-CT 영상의 유용성)

  • Joo, Young-Hoon;Sun, Dong-Il;Park, Jun-Ook;Yoo, Ie-Ryung;Kim, Min-Sik
    • Korean Journal of Head & Neck Oncology
    • /
    • v.26 no.1
    • /
    • pp.14-18
    • /
    • 2010
  • Objectives : We evaluated the use of FDG PET/CT for the identification of cervical nodal metastases of SCC of the oral cavity and oropharynx with histological correlation. Material and Methods : We reviewed 46 medical records, from January 2004 to July 2007, of patients who underwent FDG PET/CT and CT/MRI for SCC of the oral cavity and oropharynx before surgery. We recorded the lymph node metastases according to the neck level affected and the system used for the imaging-based nodal classification. Results : The FDG PET/CT had a sensitivity of 75.6% and a specificity of 96.7% ; it had a higher sensitivity than the CT/MRI for identification of cervical metastases on the side of the neck(26/28 vs. 20/28, p=0.031) and at each of the cervical levels(34/45 vs. 26/45, p=0.008). There was a significant difference in the $SUV_{max}$ between the benign and malignant cervical lymph nodes($3.31{\pm}3.23$ vs. $4.22{\pm}2.57$, p=0.028). The receiver-operating-characteristic (ROC) curve analysis for differentiating the benign from the malignant cervical lymph nodes, showed that the area under the curve(AUC) of the FDG PET/CT was 0.775. The cut-off value for the $SUV_{max}$ was 2.23 based on the ROC curve. There was a significant correlation between the $SUV_{max}$ and the size of the cervical lymph nodes(Spearman r=0.353, p=0.048). Conclusion : FDG PET/CT images were more accurate than the CT/MRI images. In addition, the $SUV_{max}$ cut-off values were important for evaluating cervical the cervical nodes in the patients with SCC of the oral cavity and oropharynx.

Is FDG -PET-CT A Valuable Tool in Prediction of Persistent Disease in Head and Neck Cancer

  • Uzel, Esengul Kocak;Ekmekcioglu, Ozgul;Elicin, Olgun;Halac, Metin;Uzel, Omer Erol
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4847-4851
    • /
    • 2013
  • Objectives: To evaluate accuracy of FDG-PET CT in prediction of persistent disease in head and neck cancer cases and to determine prognostic value of metabolic tumor response. Materials and Methods: Between 2009 and 2011, 46 patients with squamous cell carcinoma of head and neck receiving PET-CT were treated with definitive radiotherapy, with or without chemotherapy. There were 29 nasopharyngeal, 11 hypopharyngeal, 3 oropharyngeal and 3 laryngeal cancer patients, with a median age of 50.5 years (range 16-84), 32 males and 14 females. All patients were evaluated with PET-CT median 3-5 months (2.4-9.4) after completion of radiotherapy. Results: After a median 20 months of follow up, complete metabolic response was observed in 63% of patients. Suspicious residual uptake was present in 10.9% and residual metabolic uptake in 26.0% of patients. The overall sensitivity, specificity, positive predictive value and negative predictive value of FDG-PET-CT for detection of residual disease was 91% and 81%, 64% and 96% respectively. Two year LRC was 95% in complete responders while it was 34% in non-complete responders. Conclusions: FDG PET CT is a valuable tool for assessment of treatment response, especially in patients at high risk of local recurrence, and also as an indicator of prognosis. Definitely more precise criteria are required for assessment of response, there being no clear cut uptake value indicating residual disease. Futhermore, repair processes of normal tissue may consume glucose which appear as increased uptake in control FDG PET CT.