• 제목/요약/키워드: He-Ne 레이저

검색결과 156건 처리시간 0.021초

He-Ne 레이저를 이용한 표면전단응력 측정에 관한 연구 (Skin friction measurements using He-Ne laser)

  • 최승호;이열
    • 대한기계학회논문집B
    • /
    • 제21권7호
    • /
    • pp.939-947
    • /
    • 1997
  • An experimental study of the skin friction measurement in a turbulent boundary-layer has been carried out. The skin friction measurements are made using the laser interferometer skin friction (LISF) meter, which optically detects the rate of thinning of an oil applied to the test surface. This technique produces reliable skin friction data over a wide range of flow situations up to 3-dimensional complicated flows with separation, where traditional skin friction measurement techniques are not applicable. The present measured data in a turbulent boundary-layer on a flat plate using the LISF technique shows a good comparison with the result from the previous velocity profile techniques, which proves the validity of the present technique. An extensive error analysis is carried out for the present technique yielding an uncertainty of about .+-.8%, which makes them suitable for CFD code validation purposes. Finally the measurements of the skin friction in a separated region after a surface-mounted obstacle are also presented.

He-Ne 레이저와 CCD 카메라를 이용한 비접촉 3차원 측정 (Noncontact 3-dimensional measurement using He-Ne laser and CCD camera)

  • 김봉채;전병철;김재도
    • 대한기계학회논문집A
    • /
    • 제21권11호
    • /
    • pp.1862-1870
    • /
    • 1997
  • A fast and precise technique to measure 3-dimensional coordinates of an object is proposed. It is essential to take the 3-dimensional measurements of the object in design and inspection. Using this developed system a surface model of a complex shape can be constructed. 3-dimensional world coordinates are projected onto a camera plane by the perspective transformation, which plays an important role in this measurement system. According to the shape of the object two measuring methods are proposed. One is rotation of an object and the other is translation of measuring unit. Measuring speed depending on image processing time is obtained as 200 points per second. Measurement resolution i sexperimented by two parameters among others; the angle between the laser beam plane and the camera, and the distance between the camera and the object. As a result of these experiments, it was found that measurement resolution ranges from 0.3mm to 1.0mm. This constructed surface model could be used in manufacturing tools such as rapid prototyping machine.

광굴절 광기전력 물질에서의 어두운 공간솔리톤 발생 (The generation of dark spatial soliton in photorefractive photovoltaic medium)

  • 전진호;전남희;이원규;노영철;이재형;장준성
    • 한국광학회지
    • /
    • 제12권1호
    • /
    • pp.48-54
    • /
    • 2001
  • 광굴절 광기전력 특성을 갖는 Fe를 도핑한 LiNbO$_3$결정에서의 어두운 공간 솔리톤의 발생과 이의 광도파로 역할에 대해 연구하였다. 파장이 488nm인 cw $Ar^{+}$ 레이저를 이용하여 입사빔의 세기가 10mW/$cm^2$ 이하에서도 어두운 공간솔리톤이 발생됨을 관측하였다. 빔의 세기 변화 방향이 광축에 수직인 경우에는 자기확산 효과를 관측할 수 없었으나 광축에 평행한 경우에는 이 효과를 관측할 수 있었다. 이를 통해 매질에서의 굴절률 변화가 빔의 세기 변화 방향과 광축방향이 평행할 때만 일어남을 확인하였다 파장이 633nm인 He-Ne 레이저를 어두운 공간솔리톤에 통과시킴으로써 빔의 집속효과를 관측하였다. 이를 통해 어두운 공간솔리톤의 광도파로 역할을 확인하였다.

  • PDF

Heterodyne 간섭계를 이용한 공기굴절율의 절대측정 (Absolute Measurement of the Refractive Index of Air Using the Heterodyne Interferometer)

  • 엄태봉;엄천일;정명세;양준묵
    • 한국광학회지
    • /
    • 제7권1호
    • /
    • pp.37-43
    • /
    • 1996
  • 횡자장하에서 Zeeman 안정화된 He-Ne 레이저를 광원으로 한 두 종류의 공기굴절율 측정용 간섭계를 설계.제작하였다. 제작된 간섭계는 레이저 광속이 진공조와 기체조를 2번 혹은 4변 지나도록 설계하여 분해능을 향상시켰으며 그 경로가 진공조를 중심으로 대칭적으로 지나도록 설계하여 열적인 변형 및 기계적인 진동에 강한 특성을 갖도록 하였다. 진공조와 기체조 사이의 광로차를 위상각 검출 방식의 heterodyne 간섭계로 측정하므로써 homodyne 간섭계에서 발생되는 간섭무늬 해석 오차를 최소화시켜 공기굴절율 측정의 정확도를 향상시켰다. 제작된 두 굴절율계를 이용하여 여러 조건에서 공기굴절율을 측정한 결과 평균값에서의 상호 편차는 $2\times10^{-8}$ 이하였으며 Edlen공식을 이용한 굴절율계와의 편차는 $1\times10^{-7}$ 이하였다.

  • PDF

음향광변조기를 이용한 고분해능의 헤테로다인 간섭식 열팽창 측정기술 (High resolution heterodyne interferometric technique with AOM for measuring the thermal expansion)

  • 최병일;이상현;김종철;임동건
    • 한국광학회지
    • /
    • 제13권6호
    • /
    • pp.530-536
    • /
    • 2002
  • 열팽창계수의 정확한 측정은 재료과학이나 공업기술 분야에서 가장 중요한 요구량 중의 하나이다. 음향광변조기(AOM)를 이용한 고분해능 간섭식 열팽창계를 제작하여 성능검사를 하였다. 이 계는 이중광로 헤테로다인 간섭계와 복사열 전기로로 구성되어, 정밀한 변위의 측정과 시료의 신속한 가열 및 냉각이 가능토록 하였다. 또한 레이저의 주파수 안정화를 위하여 2차 맥놀이 주파수를 이용한 3종모드 안정화 He-Ne 레이저를 제작하였으며, 이때의 주파수 안정도는 5$\times$$10^{-9}$이었다. 제작된 계의 길이 측정은 실온에서 1100k온도영역에서 나노미터 정도의 정밀도를 주었다.

집속된 헬륨네온 레이저 광압을 이용한 Mie 입자들의 포획과 이동 (Trap and movement of Mie particles by using the focussed He-Ne laser beam)

  • 송영곤;조재홍;장수
    • 한국광학회지
    • /
    • 제11권3호
    • /
    • pp.141-146
    • /
    • 2000
  • 직경 $3~5{\mu}m$ 크기의 폴리그티렌 라텍스 입자들을 40배 또는 100배의 대물렌즈로 집속하여 조명한 2mW의 저출력 헬륨 네온 광속의 광압으로 포획하고, 이를 자유로이 이동시키면서 영문자 'A' 형태로 배열하였다. 그리고 수${\mu}m$ 크기의 미생물도 성공적으로 포획하고 이동시킬 수 있었다. 이 결과 저출력 헬륨네온 레이저의 광압을 이용하여 미립자나 미생물을 자유자재로 이동시키거나 모을수 있는 광집게로의 가능성을 확인하였다.

  • PDF

저 에너지 레이저 강도가 화상흰쥐의 혈청 면역글로불린의 성분 변화에 미치는 효과 (The Effects of the low power intensity He-Ne IR laser on the change of the Serum Immunoglobulin components in burn rat)

  • 노민희;김재영
    • The Journal of Korean Physical Therapy
    • /
    • 제12권3호
    • /
    • pp.469-474
    • /
    • 2000
  • This studies were to investigate the effects of low power intensity Helium-Neon Infra-Red(He-Ne IR) laser on the changes of the serum immunoglobulin(1g) components in burn rats, The fourty eight Spraque-Dawley adult male rats were assigned to the 8 groups: the experimental groups(4), the burn control groups(2) and the control groups(2) There was made three degree burn by the 250mW IR on the back of each rats, from 3 days after being burned, the experimental laser groups were irradiated low power He-Ne IR laser for 3 minutes and 4.5 minutes every day during the 7days and 21 days. The results were as follows: The concentrations of immunoglobulin G(Ig G) in serum of burn rats on the treated with during the 3minutes laser for 7 days were higher than those of burn and 4.5 minutes laser groups. There were significantly decreased the change of the level of immunoglobulin M(Ig M) in serum of burn rats on the treated with 3 minutes laser for 7 days to the control group, but were significantly increased on the 3minutes and 4.5 minutes laser groups for 21 days to the those of burn and control groups, and the levels of the Ig M on the 3minutes laser group for 21 days were higher than those of 7 days. The concentrations of immunoglobulin E(Ig E) in serun of the burn rats on the experimental and burn groups were significantly lower than those in control group. As above results, The changes of the level of immonoglobulin components in serum have meaningful role in the healing process on the treated with the low pewer intensity of HE-Ne IR laser.

  • PDF

저 에너지 레이저 파장이 화상쥐 혈청면역물질 농도 변화에 미치는 영향 (The Effects of the Low Power Wavelengths of Helium-Neon Infra- Red Laser on the Changes of the Serum Immunoglobulin Concentration in Burn Rats)

  • 노민희;용준환
    • The Journal of Korean Physical Therapy
    • /
    • 제12권3호
    • /
    • pp.287-292
    • /
    • 2000
  • This studies were to investigate the effects of low power wavelengths Helium-Neon Infra-Red(He-Ne 1R) laser on the changes of the serum immunoblobulin(Ig) concentrations in bum rats, The thirty Spraque-Dawley adult male rats were assigned to the 5 groups: the experimental groups(3). the bum control group(1) and the control group(1). There was made three degree burn by the 290 mW IR on the back oreach rats, from 3 days after being burned. the experimental laser groups were irradiated low power wavelengths(292Hz- 1168Hz, 4672Hz) He-Ne IR laser far 5 minutes every day during the 7days. The results were as follows; 1. The concentrations of immunoglobulin G(Ig G) in serum of all experimental groups on the treated with the low power wavelengths of the He-Ne IR laser during the 5 minutes far 7 days were significantly lower than those of bum groups, but those 1168 Hz group were significantly higher than those of the 292 Hz and 4672 Hz groups. 2. There were significantly decreased the change of the level of immunoglobulin M(Ig M) in serum of all experimental groups on the treated with 5 minutes laser fer 7 days to the burn control group. and were significantly increased on treated with more higher wavelengths groups to those of lower groups. 3. The concentrations immunoglobulin E(Ig E) in serum of the 292Hz wavelengths groups were significantly lower than those in bum control group. As above results. the changes of the immunoglobulin in serum levels on the healing process have meaningful effected with the low power wavelengths role on the treated with He-Ne IR laser.

  • PDF

마이켈슨 간섭계형 현미경의 특성 연구 (The study of property on the michelson interferometric microscopy)

  • 김경신;권남익
    • 한국광학회지
    • /
    • 제10권5호
    • /
    • pp.369-372
    • /
    • 1999
  • 마이켈슨 간섭계를 이용한 간섭계형 현미경을 구성하고 특성을 조사하였다. 본 마이켈슨 간섭계형 현미경은 시료 표면의 반사 신호와 거울의 반사 신호가 합쳐져서 일어난 간섭 신호를 이용해서 3차원 영상을 얻는다. He-Ne(λ=633 nm)레이저를 사용한 마이켈슨 간섭계는 반파장 (312.5 nm)의 경로차가 생길 때마다 같은 무늬가 반복해져 나타난다. 본 마이켈슨 간섭계형 현미경은 이러한 간섭 신호를 이용하기 때문에 white-light interferometer 수준의 수직 해상도를 얻을 수 있었다. 구성한 마이켈슨 간섭계형 현미경으로 얻은 영상을 공초점 현미경의 영상과 비교 분석하였다.

  • PDF

광통신 변조기용 미세광학소자의 설계 (Micro lens system design for the optical fiber communication)

  • 홍경희
    • 한국광학회지
    • /
    • 제3권4호
    • /
    • pp.217-221
    • /
    • 1992
  • 광통신에 각종 modulator를 사용할 경우에 대비하여 plano-convex coupling 미세광학소자를 설계하였다. 광섬유에서 회절되는 광을 시준시켜 modulate할 수 있도록 하는 시준렌즈와 modulate된 광을 광섬유에 연결시키는 coupling렌즈를 설계하였다. 광원은 He-Ne 레이저 빔으로하고 렌즈의 초자는 BK-7 크라우ㅌ계 광학유리로 하였다. 곡률반경과, 거리 및 conic costant가 광학계의 광선수차에 미치는 영향을 조사하였다.

  • PDF