• Title/Summary/Keyword: He-Ne 레이저

Search Result 156, Processing Time 0.032 seconds

Effects of the low power He-Ne IR laser on the changes of the chemical components in serum of the peripheral neuropathy in diabetic rats (저에너지 He-Ne IR 레이저가 말초신경병증 당뇨쥐의 혈액화학 성분 변화에 미치는 영향)

  • Rho, Min-Hee;Kim, Jae-Young;Lee, Mi-Ae;Baek, Su-Jeong
    • Journal of Korean Physical Therapy Science
    • /
    • v.8 no.2
    • /
    • pp.1033-1038
    • /
    • 2001
  • This studies were to investigate the effects of low power Helium-Neon Infra-Red(He-Ne IR) laser on the changes of the chemical components in serum of the peripheral neuropathy in diabetic rats. The twenty one Spraque-Dawley adult male rats were assigned to the 3 groups: the control group(N=7), the diabetic group(n=7) and the laser group(n=7). The diabetic group was induced with a single intravenous injecion of 50mg/kg body weight streptozotocin dissolved to 0.01mol/L citrate buffer, pH 4.5. The experimental1asser group was irradiated low power He-Ne IR laser for 5 minutes every day during 21 days to the diabetic group. The results were as follows: 1. ALT was increased the laser treatment group than the diabetic group. but that was not significant. 2. AST was significantly increased the laser treatment group than the control group and the diabetic group. 3. LDH was significantly decreased the diabetic group and laser treatment group. 4. ALP was significantly increased the diabetic group and laser treatment group. 5. CHOL was significantly decreased the laser treatment group than the diabetic group. 6. TRIG was significantly increased the laser treatment group than the diabetic group. 7. CPK was significantly increased the laser treatment group than the control group and the diabetic group.

  • PDF

Measurement of the Thermal Behavior of a Nd:YAG Laser Rod by Analyzing Interference Fringe from a He-Ne Probe Beam (He-Ne 레이저 탐사광의 간섭효과를 이용한 Nd:YAG 레이저봉의 온도측정)

  • 김광석;공홍진;김덕현;김철중
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.204-209
    • /
    • 1990
  • The temperature variation at a laser rod center induced by high repetetion rate pumping was measured by counting the number of inteference frigne shift and found to be consistent with the theoretical value obtained from heat diffusion equation. The spatial homogeneity and energy transfer rate of flashlamp pumping by the single elliptical reflector plated with gold were evaluated by measuring interference fringes oever the cross section of a Nd:YAG laser rod.

  • PDF

I2-Saturated Absorption Spectroscopy for Frequency-Stabilization of He-Ne Laser at 543 nm (543 nm 헬륨네온 레이저의 주파수 안정화를 위한 I2 포화흡수분광)

  • Kim, Kyung-Chan;Eum, Nyeon-Sik;Hong, Joo-Hyun;Seo, Ho-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.859-865
    • /
    • 2010
  • We have designed and assembled a saturated absorption-spectroscopy system of $^{127}I_2$ for the frequency stabilization of the 543 nm He-Ne laser. The frequency of a internal-mirror 543 nm He-Ne laser was swept by utilizing the temperature and PZT change of the laser cavity length. Frequency modulation was applied to the output laser mirror with a PZT modulator for the third harmonic signal. A portion of the hyperfine spectrum originated from the R(12)26-0 and R(106)28-0 transitions of the B-X system of $^{127}I_2$ was observed as the third-derivative signal using a saturated absorption spectroscopy. The signal-to-noise ratio of a typical hyperfine spectrum signal was estimated to be 30:1.

Effect of Intravenous He-Ne Laser Irradiation on Cholesterol Value of Hyperlipidemia Patients (정맥 혈관내 He-Ne 레이저 조사가 고지혈증 환자의 지질 수치에 미치는 영향)

  • Ryu, Hyun-Hee;Son, Ji-Young;Lee, Seoung-Geun;Yun, Jong-Min;Lee, Gi-Sang
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.4
    • /
    • pp.86-92
    • /
    • 2004
  • In order to determine the effect of intravenous He-Ne laser irradiation, values of serum total cholesterol, Triglyceride, LDL-cholesterol and HDL-cholesterol were measured. Twenty three patients with hyperlipidemia who visited Gunpo Oriental Medical Center of Wonkwang University were treated with He-Ne laser irridiation and analyzed by Paired T-test of SPSS program. The following results were obtained : The serum Total cholesterol and LDL-cholesterol of patients treated with He-Ne laser irradiation showed a significant(P<0.05) decrease, and the serum Triglyceride and HDL-cholesterol of patients treated with He-Ne laser irradiation showed no significant(P<0.05) effects.

  • PDF

A High-Resolution Heterodyne Interferometer using Beat Frequency between Two-Axial Modes of a HeNe Laser (2-종 모드 레이저를 이용한 고분해능 헤터로다인 간섭계)

  • 김민석;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1997.10a
    • /
    • pp.214-219
    • /
    • 1997
  • We propose a new scheme of high-resolution heterodyne interferometer that employs the two-axial mode He-Ne laser with an inter-mode beat frequency of 600-1000 MHz. An electronic RF-heterodyne circuit lowers the beat frequency down to 5 MHz, so that the phase change of the interferometer output is precisely measured with a displacement resolution of 0.1 nanometer without significant loss of dynamic bandwidth. A thermal control scheme is adopted to stabilize the cavity length with aims to suppress frequency drifts caused by the phenomena of frequency pulling and polarization anisotropy of the two-axial mode laser to a stability level of 2 parts in $10^9$. The two-axial mode HeNe laser yields a high output power of 2.0 mW, whlch allows us to perform multiple measurements of up to 10 machine axes simultaneously.

  • PDF

Frequency stabilization of HeNe laser for interferometry (간섭계용 헬륨-네온 레이저의 주파수 안정화)

  • 주기남;김승우
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.260-263
    • /
    • 2003
  • Lasers are used as the source of the interferometers in the industrial field. These lasers need 2 requirements. The first is the narrow linewidth of laser for the long coherence length. The second is the stabilized frequency of laser for the precision measurement. Now HeNe lasers are mostly used and the frequency stability is about 10$^{-9}$ . In this paper, we construct the HeNe laser systems of frequency stabilization using typical 2 method, the beat frequency stabilization method and the intensity difference method. So, we get the frequency stabilities of 2.01$\times$10$^{-9}$ (0.1s), 3.4$\times$10$^{-9}$ (0.1s).

  • PDF

The Effect of He-Ne IR Laser Therapy on The Healing of Acute Septic Knee Arthritis in Rat (흰쥐의 화농성 슬관절염 치유에 He-Ne IR레이저 처치의 효과)

  • 김재영;노민희;고진복
    • Biomedical Science Letters
    • /
    • v.6 no.3
    • /
    • pp.223-228
    • /
    • 2000
  • The purpose of this study was to find out the effect of He-Ne, IR laser therapy for 4 and 10 minutes on healing of septic arthritis. Sprague-Bawley rats (212.1$\pm$10 g) were randomly assigned to one control and three arthritis groups. Septic arthritis groups were divided into arthritis control, 4 or 10 minute laser therapy groups. Arthritis was experimentally induced by intraperitoneally administration of staphylococcus aureus in citrate buffer(pH 4.3). These result were obtained as follows: AST, LDH, ALP, CK activities and IgG concentration in 10 minute laser group were signifantly increased compare with those in the arthritis group. AST, LDH and CK activities in 4 minute laser group were significantly decreased compare with those in the arthritis group. We think that laser therapy in 4 minute may effective on the healing of septic arthritis. And we will have to study of the effect of laser therapy on healing mechanism, appropriate time of septic arthritis.

  • PDF

MEASUREMENTS OF FREQUENCY SHIFT DUE TO POLARIZATION ANISOTROPY AND FREQUENCY PULLING EFFECT (레이저반사경의 비등방평과 주파수 당김효과에 의한 발진 주파수 편이 측정)

  • 서호성
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1990.02a
    • /
    • pp.182-184
    • /
    • 1990
  • 633M He-Ne 레이저의 반사경의 비등방성에 의한 발진 주파수 편이 및 레이저 매질의 분산특성 때문에 기인하는 레이저 주파수 당김효과를 측정하였다. 내부 반사경형 레이저 공진기에서 발진하는 종모드사이의 맥놀이 신호를 RF-스펙트럼 분석기로 분석하므로써 90kHz의 주파수 편이량차를 측정하였다.

  • PDF

Development of Retina Photographing System and 16 Channels Image Acquisition System (망막 촬영 장치 및 16 채널 영상 획득 장치 개발)

  • 양근호
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.1
    • /
    • pp.96-101
    • /
    • 2004
  • In order to measure the retina thickness, there are to need the 3-D retina photographing and the high speed signal processing system. In this paper, we introduced the retina photographing system and the 16-channel high speed image data acquisition system. There are able to measure the retina thickness with sensing image the returned laser signal to APD sensor after there were projected the HeNe laser on retina. We developed the laser projection system to sense a reflected image of the retina using APD sensor, the 16-channel high speed A/D converter and PCI master interface card for image transmission into computer.

Measurement of Wire Displacement of WEDM using He-Ne laser (He-Ne 레이저를 이용한 와이어 방전가공기의 와이어 변위 측정)

  • 홍준모;전병철;조용무;유웅재;김재도
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.414-419
    • /
    • 1995
  • The wire displacement of wire electric discharge machine has been measured using He-Ne laser. A measurement system consisted of He-Ne laser, A/D converter, 4 divided photodiode, amplifier, sensor process instrument, and personal computer. The processing parameters were varid with feed rate, wire tension, wire speed and voltage. The laser beam intensity transmitted on a 4 divided photodiode was varied by processing wire electric descharge machine with various process parameters. The 4 divided photodiode and amplifier were used to change the detected beam intensity into voltage. Variation of wire displacement was between 11 and 125 .mu. m. The wire tension was dominant on the variation of wire displacement among many parameters.

  • PDF