• Title/Summary/Keyword: Hazardous area

Search Result 393, Processing Time 0.033 seconds

Methodology for Near-miss Identification between Earthwork Equipment and Workers using Image Analysis (영상분석기법을 활용한 토공 장비 및 작업자간 아차사고식별 방법론)

  • Lim, Tae-Kyung;Choi, Byoung-Yoon;Lee, Dong-Eun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.4
    • /
    • pp.69-76
    • /
    • 2019
  • This paper presents a method that identifies the unsafe behaviors at the level of near-misses using image analysis. The method establishes potential collision hazardous area in earthmoving operation. It is implemented using a game engine to reproduce the dangerous events that have been accepted as major difficulty in utilizing computer vision technology to support construction safety management. The method keeps realistically track of the ever-changing hazardous area by reflecting the volatile field conditions. The method opens a way to distinguish unsafe conditions and unsafe behaviors that have been overlooked in previous studies, and reflects the causal relationship which causes an accident. The case study demonstrate how to identify the unsafe behavior of a worker exposed to an unsafe area created by dump trucks at the level of near-misses and to determine the hazardous areas.

Investigation of Norovirus Occurrence and Influence of Environmental Factors in Food Service Institutions of ChungCheong Area (충청지역 집단급식소의 노로바이러스 실태조사와 환경요인의 영향)

  • Jung, Woo-Young;Eom, Joon-Ho;Kim, Byeong-Jo;Yun, Min-Ho;Ju, In-Sun;Kim, Chang-Soo;Kim, Mi-Ra;Byun, Jung-A;Park, You-Gyoung;Son, Sang-Hyuck;Lee, Eun-Mi;Jung, Rae-Seok;Na, Mi-Ae;Yuk, Dong-Yeon;Gang, Ji-Yeon;Heo, Ok-Sun
    • Journal of Food Hygiene and Safety
    • /
    • v.25 no.2
    • /
    • pp.153-161
    • /
    • 2010
  • The purpose of this study was to examine the appearance of norovirus in the water for food in food service institutions and the influence of physicochemical and microbial factors of norovirus in order to work out basic data to predict the detection of norovirus. Among 82 samples of water for food in food service institutions, norovirus appeared in 7 samples and the rate of appearance was 8.5%. As for the type of norovirus, one samples contained GI type (genotype GI-6) and six samples contained GII type (genotype GII-2, GII-4, GII-12). In the regression model of prediction of norovirus, the rate of appearance was correlated with $NH_3$-N, total solids and the consumption of $KMnO_4$, out of such variables as $NH_3$-N, total solids, the consumption of $KMnO_4$, depth, chloride and total colony counts, and its contribution rate for effectiveness was 78.60%. In order to examine the influential factor of environment upon the detection of norovirus, Pearson's correlation analysis was carried out. The predictable regression formula for appearance rate of norovirus was expressed as -1.818 + 42.677 [$NH_3$-N] + 0.023 [total solids] + 0.762 [consumption of $KMnO_4$] -0.009 [depth] -0.146 [chloride] + 0.007 [total colony counts] (R = 0.904, $R^2$ = 0.818, adjusted $R^2$ = 0.786, p < 0.05). The most influential factors upon the detection of norovirus were $NH_3$-N, total solids and the consumption of $KMnO_4$. In other words, when the measured values of $NH_3$-N, total solids and the consumption of $KMnO_4$ were higher, the possibility of appearance of norovirus increased.

A study on the status of working environment control and health management of workers in a manufacturing industries (일부 제조업 사업장의 작업환경 및 보건관리 실태)

  • Ham, Jung-O;Hwang, Kyu-Yoon;Ahn, Kyu-Dong;Lee, Byung-Kook;Nam, Tack-Sung
    • Journal of Preventive Medicine and Public Health
    • /
    • v.23 no.3 s.31
    • /
    • pp.275-284
    • /
    • 1990
  • To obtain the useful information for the status of working environment and health management of workers in manufacturing industries, comparision of results on the status of working environmental and health management of workers for 32 manufacturing industries in Chunan area from 1988 to 1989 was carried out. The results were as follows : 1. The rate of over-PEL (Permissible Exposure Limit) to for hazardous factors decreased significantly 23.5% in 1988, 18.3% in 1989 (p<0.05) and, the highest rate of over-PEL was the stone and sand handling industry, the highest rate of over-PEL was the dusty workplace as 38.5% in 1988, 35.2% in 1989. 2. The rate of workers exposed to hazardous factors in 1988 and in 1989 was 22.4% respectively, the rate of workers checked up special health examination was 40.1% in 1988, 75.3% in 1989. In stone and sand handling and medicochemical industries, none of workers exposed to hazardous factors was subjected to special health examination in 1988, but 75% of workers exposed to hazardous factors had checked up in 1989. 3. The 6 industries appointed as part-time factory physician among 17 industries which were supposed to have factory physician according to the Safety and Healthy Act of Korea, 6 out of 24 industries only appointed industrial hygienist, furthermore 4 out of 6 hygienists had another duty in addition to occupational hygiene itself.

  • PDF

Control and Investigation for Hazardous Characteristics of Metalworking Fluids Used in Korea - Control and Hazardous Characteristics of Soluble MWF (우리나라에서 사용하는 광물유(금속가공유)의 유해특성과 관리대책에 관한 연구 -수용성 금속가공유의 유해특성과 관리대책-)

  • Paik, Nam-won;Park, Dong-wook;Yoon, Chung-sik;Kim, Seung-won;Kim, Shin-bum;Kim, Kwi-suk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.8 no.1
    • /
    • pp.67-75
    • /
    • 1998
  • The objectives of this study were both to evaluate the level and correlations of hazardous agents and to suggest measures to control industrial hygiene problems caused by using water-soluble metalworking f1uids(MWF). Geometric mean of formaldehyde(0.039 ppm) was higher than criteria of NIOSH(0.016ppm). Formaldehyde, originally existed in the biocide, is released and used to kill microbes in soluble MWF. Microbe concentrations were above $10^4No./mL$ in 14 MWF tanks among 20 tanks surveyed. Nitrosamines that is formed by reaction of nitrosating group and amines was detected to $18.4-47.1{\mu}g/m^3$. Formaldehyde concentration was low when microbes were abundant(r=-0.67, p=0.011), and high when open tank area was wide(r=0.75. p=0.012). The significant relationship between pH and microbes(r=-0.76. p=0.003) was also observed. The predominant bacteria species in MWF were Pseudomonas spp., Bacillus spp., Comamonas testosteroni, Acinetobacter haemolyticus, Bordertella bronchiseptica in order. Therefore, hazardous agents emitted by using water-soluble MWF seems to be correlated microbial growth. In order to minimize worker's exposure to several hazardous agents by an water-soluble MWF and to increase productivity, microbial growth must be controlled to the lowest level as possible. Administrative control as well as engineering control must comprehensively be applied to control microbe's growth in water-soluble MWF.

  • PDF

Dispersal of Hazardous Substance in a City Environment Based on Weather Conditions and Its Risk Assessment at the Pedestrian Level (기상조건에 따른 도시내 위험물질 확산정보와 보행자환경 위험영향평가)

  • Kim, Eun-Ryoung;Lee, Gwang-Jin;Yi, Chaeyeon
    • Journal of Environmental Impact Assessment
    • /
    • v.26 no.4
    • /
    • pp.242-256
    • /
    • 2017
  • In this paper, dispersion scenarios concerning various meteorological conditions and real urban structures were made to estimate the impacts of hazardous substance leakage accidents and to reduce damages. Based on the scenario of the hazardous substance dispersion, the characteristics of the risk in the pedestrian environment were analyzed in Gangnam, Seoul. The scenarios are composed of 48 cases according to the meteorological conditions of wind direction and wind speed. In order to analyze the dispersion characteristics of the hazardous substances, simulations were conducted using a computational fluid dynamic (CFD) model with hydrogen fluoride releases. The validation for the simulated wind was conducted at a specific period, and all the calculated verification indices were within the valid range. As a result of simulated dispersion field at pedestrian level, it was found that the dispersion pattern was influenced by the flow, which was affected by the artificial obstacles. Also, in the case of the weakest wind speed of the inflow, the dispersion of the hazardous substance appeared in the direction of the windward side at the pedestrian level due to the reverse flow occurred at lower layers. Through this study, it can be seen that the artificial structures forming the city have a major impact on the flow formed in urban areas. The proposed approach can be used to simulate the dispersion of the hazardous substances and to assess the risk to pedestrians in the industrial complexes dealing with actual hazardous substances in the future.

A Study on the Examination of Explosion Hazardous Area Applying Ventilation and Dilution (환기 및 희석을 적용한 폭발위험장소 검토에 관한 연구)

  • kim, Nam Suk;Lim, Jae Geun;Woo, In Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.4
    • /
    • pp.27-31
    • /
    • 2018
  • Classification of explosion hazard areas is very important in terms of cost and safety in the workplace handling flammable materials. This is because the radius of the hazardous area determines whether or not the explosion-proof equipment is installed in the electrical machinery and apparatus. From November 6, 2017, KS C IEC-60079-10-1: 2015 will be issued and applied as a new standard. It is important to understand and apply the difference between the existing standard and the new standard. Leakage coefficients and compression factors were added to the leakage calculation formula, and the formula of evaporation pool leakage, application of leakage ball size, and shape of explosion hazard area were applied. The range of the safety factor K has also been changed. Also, in the radius of the hazardous area, the existing standard applies the number of ventilation to the virtual volume, but the revised standard is calculated by using the leakage characteristic value. In this study, we investigated the differences from existing standards in terms of ventilation and dilution and examined the effect on the radius of the hazard area. Comparisons and analyzes were carried out by applying revised standards to workplaces where existing explosion hazard locations were selected. The results showed that even if the ventilation and dilution were successful, the risk radius was not substantially affected.

Characteristics of Hazardous Volatile Organic Compounds (HVOCs) at Roadside, Tunnel and Residential Area in Seoul, Korea (서울시 도로변, 터널 및 주거지역 대기 중 유해 휘발성 유기화합물의 특성)

  • Lee, Je-Seung;Choi, Yu-Ri;Kim, Hyun-Soo;Eo, Soo-Mi;Kim, Min-Young
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.5
    • /
    • pp.558-568
    • /
    • 2011
  • Hazardous volatile organic compounds (HVOCs) have been increasingly getting concern in urban air chemistry due to photochemical smog as well as its toxicity or potential hazards. In this study, we investigated their concentrations and the properties in tunnel, urban roadside and residential area. As a result, among 36HVOCs measured in this study, BTEX (benzene, toluene, ethylbenzene, xylene) and dichlorodifluoromethane, 1,2,4-trimethylbenzene, trichlorofluoromethane were detected above the concentration of $1{\mu}g/m^3$ in every sampling site and the most abundant compound was toluene. The other compounds were detected at trace level or below the detection limit. In addition, we found that three CFCs (chlorofluorocarbons), such as CFC-12, CFC-11, CFC-113, were persistently detected because of the emission in the past. Toluene to benzene ratio (T/B) at tunnel and roadside were calculated to be 4.3~5.3 and at residential area 15.4, suggesting that the residential area had several emission sources other than car exhaust. The ratio of X/E (m,p-xylene to ethylbenzene) ratio was calculated to be 1.8~2.1 at tunnel, 1.7 at roadside and 1.2 at residential area, which means this ratio reflected well the relative photochemical reactivity between these compounds. Good correlation between m,p-xylene and ethylbenzene ($r^2$ > 0.85) were shown in every study sites. This indicated that correlation between $C_2$-alkylbenzenes were not severely affected by 3-way catalytic converter. In this study, it was demonstrated that the concentration of benzene was very low, compared with national air quality standard (annual average of $5{\mu}g/m^3$). Its concentration were $2.52{\mu}g/m^3$ in roadside and $1.34{\mu}g/m^3$ in residential area. We thought this was the result of persistent policy implementation including the reduction of benzene content in gasoline enforced on January 1, 2009.

Experimental Performance Validation of an Unmanned Surface Vessel System for Wide-Area Sensing and Monitoring of Hazardous and Noxious Substances (HNS 광역 탐지 및 모니터링을 위한 부유식 무인이동체 시스템의 실험적 성능 검증)

  • Jinwook Park;Jinsik Kim;Jinwhan Kim;Yongmyung Kim;Moonjin Lee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.28 no.spc
    • /
    • pp.11-17
    • /
    • 2022
  • In this study, we address the development of a floating platform system based on a unmanned surface vessel for wide-area sensing and monitoring of hazardous and noxious substances (HNSs). For long endurance, a movable floating platform with no mooring lines was used and modified for HNS sensing and monitoring. The floating platform was equipped with various sensors such as optical and thermal imaging cameras, marine radar, and sensors for detecting HNSs in water and air. Additionally, for experiment validation in real outdoor environments, a portable gas-exposure system (PGS) was built and installed on the monitoring system. The software for carrying out the mission was integrated with the Robot Operating System (ROS) framework. The practical feasibility of the developed system was verified through experimental tests conducted in inland water and real-sea environments.

Evaluation of Air Quality with and without Vapor Recovery Systems of Stage II (주유소 Stage II의 유증기회수설비 가동에 따른 대기질 평가)

  • Kim, Jae Hyuck;Jung, Seok Hyeon;Kim, Hyung-Seok;Jang, Tae-Hyuk;Yoo, Kyung Seun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.6
    • /
    • pp.801-810
    • /
    • 2013
  • A field study was conducted to evaluate air quality from gas stations with and without Stage II vapor recovery systems that are currently used to reduce VOCs. The THC and VOCs levels were monitored for the test at three locations (inside office, around refueling area, site boundary) from a total of five gas stations. The results showed a considerable reduction in THC concentration which ranged from 48.7% to 81.8% with and without the operation of the Stage II VRS. Acoording to our comparative analysis, BTEX and other 19 VOCs levels were also significantly reduced with Stage II vapor recovery systems.

Use of hazardous event frequency to evaluate safety integrity level of subsea blowout preventer

  • Chung, Soyeon;Kim, Sunghee;Yang, Youngsoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.3
    • /
    • pp.262-276
    • /
    • 2016
  • Generally, the Safety Integrity Level (SIL) of a subsea Blowout Preventer (BOP) is evaluated by determining the Probability of Failure on Demand (PFD), a low demand mode evaluation indicator. However, some SIL results are above the PFD's effective area despite the subsea BOP's demand rate being within the PFD's effective range. Determining a Hazardous Event Frequency (HEF) that can cover all demand rates could be useful when establishing the effective BOP SIL. This study focused on subsea BOP functions that follow guideline 070 of the Norwegian Oil and Gas. Events that control subsea well kicks are defined. The HEF of each BOP function is analyzed and compared with the PFD by investigating the frequency for each event and the demand rate for the components. In addition, risk control options related to PFD and HEF improvements are compared, and the effectiveness of HEF as a SIL verification for subsea BOP is assessed.