• Title/Summary/Keyword: Hazardous Gas

Search Result 347, Processing Time 0.032 seconds

Research Progress in Membrane and Catalyst for Highly Selective Chemiresistive Gas Sensors (저항변화식 가스센서 선택성 향상을 위한 멤브레인 및 촉매 연구동향)

  • Jang, Ji-Soo
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.1
    • /
    • pp.11-17
    • /
    • 2022
  • Direct exposure to toxic and hazardous gases has always been considered as the most pervasive problem worldwide, leading to a gradual increase in the number of asthma patients due to NOx/SOx gases inhaling and exposure to 50 ppm formaldehyde gases. Therefore, the development of accurate gas sensors is a key issue for resolving these problems. To address such issues, the development of membranes for selective filtering of target molecules as well as nanocatalyst for enhancing the sensing selectivity is highly crucial. In this review, the research progress for porous membrane materials (e.g. MOFs, and graphene) and nanocatalyst technology for the development of selective and accurate gas sensors will be discussed.

Use of hazardous event frequency to evaluate safety integrity level of subsea blowout preventer

  • Chung, Soyeon;Kim, Sunghee;Yang, Youngsoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.3
    • /
    • pp.262-276
    • /
    • 2016
  • Generally, the Safety Integrity Level (SIL) of a subsea Blowout Preventer (BOP) is evaluated by determining the Probability of Failure on Demand (PFD), a low demand mode evaluation indicator. However, some SIL results are above the PFD's effective area despite the subsea BOP's demand rate being within the PFD's effective range. Determining a Hazardous Event Frequency (HEF) that can cover all demand rates could be useful when establishing the effective BOP SIL. This study focused on subsea BOP functions that follow guideline 070 of the Norwegian Oil and Gas. Events that control subsea well kicks are defined. The HEF of each BOP function is analyzed and compared with the PFD by investigating the frequency for each event and the demand rate for the components. In addition, risk control options related to PFD and HEF improvements are compared, and the effectiveness of HEF as a SIL verification for subsea BOP is assessed.

Determination of Volatile Fatty Acids in Aqueous Samples by HS-SPME with In-Fiber Derivatization (Fiber내 유도체화/HS-SPME를 이용한 수용액 시료 중 휘발성 지방산의 분석)

  • Ahn, Yun Gyong;Lee, Jee Yeon;Kim, Jeehyeong;Hong, Jongki
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.458-465
    • /
    • 2003
  • The HS (headspace)-SPME (Solid phase microextraction) as rapid and simple method was performed for the determination of volatile fatty acids (VFAs) from the aqueous samples. In-fiber derivatization of VFAs with 1-Pyrenyldiazomethane (PDAM) was applied to improve their sensitivity of detection. In SPME procedure, typical parameters such as effects of solution pH, and salting out reagent and ultrasonication were investigated to improve the extraction efficiency. Based on the developed method, VFAs in wastewater samples were determined by gas chromatography / mass spectrometry-selected ion monitoring (GC/MS-SIM) mode.

Formation of Pyro-products by the Pyrolysis of Monobromophenols

  • Na, Yun-Cheol;Seo, Jung-Ju;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.9
    • /
    • pp.1276-1280
    • /
    • 2003
  • Thermal behavior of bromphenols was investigated by direct pyrolysis at high temperature. The thermal degradation products formed by the pyrolysis of mono-bromophenols (o-, m-, and p-) were identified by gas chromatography-mass spectrometry. During the pyrolysis reactions, several kinds of dioxins and furans were produced, and the relative ratio of pyro-products was dependent on the substituted position of bromine in phenolic structure due to the effect of symmetry and steric hindrance. The formation of dioxins can be explained by the phenoxy radical addition and Br atom elimination at an ortho-carbon site on phenolic structure. On the other hand, the formation of furans can be explained by the ortho-ortho carbon coupling of phenoxy radicals at unsubstituted sites to form o, o'-dihydroxydiphenyl intermediate via its keto-tautomer, followed by $H_2O$ elimination. The pyrolysis temperature has also a substantial effect on the dimerized products quantities but little effect on the type of pyro-products. Moreover, the formation mechanism of pyro-products was suggested on the basis of products identified.

A Study on the Risk Assessment and Mitigation Plan about Fire Explosion of n-Pentane in EPS Process (EPS공정에서 발생하는 n-Pentane의 화재폭발에 대한 위험성평가 및 위험성 완화 대책에 관한 연구)

  • Seo, Min Su;Kim, Ki Sug;Kim, Bo Min;Kang, Dong Cheon;Kang, Kil Jae;Chon, Young Woo
    • Korean Journal of Hazardous Materials
    • /
    • v.6 no.2
    • /
    • pp.39-46
    • /
    • 2018
  • 최근 전자제품 생산업체에서 EPS를 직접생산하게 되면서 EPS 공정이 증가하고 있다. EPS에는 펜탄이 포함되어 있으며, 펜탄은 하이브리드 혼합물로 구분할 수 있어 높은 화재폭발의 위험성을 가지고 있다. 각 공정별 펜탄의 누출률은 발포기, 사일로실, 저장실 순이나 발포기의 경우 일반적으로 밀폐되어 있으므로 사일로 실이 가장 화재폭발 위험성이 높다고 판단하였다. 사일로실의 누출률 중 70%는 사일로 상단을 통해 누출되며, 사일로 상단을 통해 누출되는 펜탄의 거동을 분석하여 사일로실 위험성 완화대책을 수립하였다. 1. 폭발위험구역 2종으로 관리, 2. 사일로상단 50cm이내 환기설비 설치 또는 Push-Pull 구조의 환기설비설치, 3. 사일로 하단 1.4m이내에 가스감지기 설치, 4. 60%이상의 습도유지

An analysis of Volatile Organic Compounds for the Application of Petroleum-based UVCB Substances to the Occupational Safety and Health Act (석유계 UVCB 물질의 산업안전보건법 규제 적용을 위한 일부 휘발성 유기화합물 분석)

  • Jeong-Hee, Han;Na-Young, Park;Na-Roo, Lee
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.32 no.4
    • /
    • pp.371-380
    • /
    • 2022
  • Objectives: To ensure that employers handling petroleum compounds understand whether petroleum-based UVCB (unknown or variable composition, complex reaction products, or biological materials) substances contain hazardous substances and comply with the Occupational Safety and Health Act, petroleum-based UVCB substances were analyzed and the results from samples were compared with MSDS (Material Safety Data Sheet) contents. Methods: Twenty-one petroleum samples were analyzed using GC-MS (Gas Chromatography-Mass Spectrometry), targeting ten volatile organic compounds regulated by the Occupational Safety and Health Act. Results: The target chemicals were detected in 13 out of 21 samples. All 13 samples were in the naphtha (low boiling point naphthas (gasolines)) group. There were also naphtha group samples containing 2% benzene. Some naphtha samples used as solvents contained about 1% benzene. Conclusions: This study shows that naphtha group petroleum substances contain hazardous chemicals in many cases. In particular, if benzene, n-hexane, and toluene with low occupational exposure limits are contained above the limit concentration. Such information should be delivered in the article on MSDS legal regulations.

A Mobile Application for Navigating the Optimal Escape Route in Accidents and Emergency Situations (모바일 어플리케이션을 이용한 재난상황 발생 시 최적 대피경로 설정)

  • Cho, Sung Hyun;Joo, Ki Don;Kang, Hoon;Park, Kyo Shik;Shin, Dong Il
    • Korean Journal of Hazardous Materials
    • /
    • v.3 no.1
    • /
    • pp.28-36
    • /
    • 2015
  • In early 2011, the Fukushima nuclear power plant had greater damage due to earthquake in Japan, and the awareness of safety has increased. In particular, special response systems should be required to handle disaster situations in plant sites which are likely to occur for large disasters. In this study, a program is designed to set up optimum escape routes, by a smart phone application, when a disaster situation occurs. This program could get information of the cumulative damage from sensors and display the escape route of the smallest damage in real-time on the screen. Utilizing our application in real-time evacuation has advantage in reducing cumulative damage. The optimal evacuation route, focusing on horizontal path, is calculated based on getting the data of fire, detected radioactivity and hazardous gas. Thus, using our application provides information of optimal evacuation to people who even can not hear sensor alarms or do not know geography, without requiring additional costs except fixed sensors or server network deployment cost. As a result, being informed of real-time escape route, the user could behave rapidly with suitable response to individual situation resulting in improved evacuation than simply reacting to existing warning alarms.

Development of a Type 4 Composite Cylinder for Self-contained Breathing Apparatus (공기호흡기용 타입 4 복합재료 용기 개발)

  • Cho, Sung-min;Kim, Da-eun;Seong, Hye-jin;Ko, Young-kyu;Kim, Hong-chul;Lee, Kang-ok;Jo, Min-sik;Lyu, Sung-ki
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.18 no.12
    • /
    • pp.1-6
    • /
    • 2019
  • Aluminum liners used in cylinders are hazardous for human health. In this study, we use a plastic PA liner inside cylinders to solve this problem. Plastic PA liners are widely used in the manufacturing industry in the production of food and beverage containers. We covered the aluminum boss with a plastic liner material and wound the composite fibers over the liner material. To reinforce the dome area, we used low strength / high elongation plastic liner. To predict the performance of the developed product, we conducted structural analyses utilizing the 3D laminated solid element. We verified the soundness of the product by testing the prototype.

Xylene Sensor Using Cr-doped Cr-Co3O4 Nanoparticles Prepared by Flame Spray Pyrolysis (화염 분무 열분해법으로 합성된 Cr-Co3O4 나노입자 자일렌 가스센서)

  • Jeong, Seong-Yong;Jo, Young-Moo;Kang, Yun Chan;Lee, Jong-Heun
    • Journal of Sensor Science and Technology
    • /
    • v.29 no.2
    • /
    • pp.112-117
    • /
    • 2020
  • Xylene is a hazardous volatile organic compound that should be precisely measured to monitor indoor air quality. However, the selective and sensitive detection of ppm-level xylene using oxide-semiconductor gas sensors remains a challenge. In this study, pure and Cr-doped Co3O4 nanoparticles (NPs) were prepared using flame spray pyrolysis, and their gas-sensing characteristics to 5-ppm xylene at 250 ℃ were investigated. The 4 at% Cr-doped Co3O4 NPs exhibited a high gas response to 5-ppm xylene (resistance ratio to gas and air = 39.1) and negligible cross-responses to other representative and ubiquitous indoor pollutants such as ethanol, benzene, formaldehyde, carbon monoxide, and ammonia. In this paper, the enhancement of the gas response and selectivity of Co3O4 NPs to xylene by Cr doping was discussed in relation to the catalytic promotion of the gas-sensing reaction. This sensor can be used to monitor indoor xylene.

A Study on the Barrier of Intrinsic Safety Type (본질안전방폭용 BARRIER에 관한 연구)

  • 오진석
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.938-945
    • /
    • 2004
  • Intrinsic safety is generally considered the safest method of operating electrical instrumention in potentially explosive atmospheres. The method of intrinsic safety limits the energy passing into the hazardus area. The energy limitation is provided by the use of safety barriers which are mounted in the safe area. Because of the energy limitation, regardless of the fault in the hazardous area, sufficient energy cannot be released to ignite the explosive atmosphere. The following industries are known to have hazardous locations: chemical. munitions, petrochemical, auto(paint spray booths), grain, waste water, printing, distillers, pharmaceutical. breweries, cosmetics, and utilities. In this paper, a isolator type barrier for ship(LNG, LPG, etc,) and test equipment confidence are proposed. The test equipments are designed for mechanical electrical life time test and vibration. All of test results satisfy the goal and the studied barrier shows the improved confidence.