• 제목/요약/키워드: Harmonics reduction

검색결과 263건 처리시간 0.033초

Harmonics Reduction in the High-Speed Synchronous Reluctance Motor by Space-Vector PWM Control

  • Oh, Sung-Up;Kim, Min-Tae;Seong, Se-Jin;Paek, Tong-Ki
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 Proceedings ICPE 98 1998 International Conference on Power Electronics
    • /
    • pp.758-762
    • /
    • 1998
  • Many harmonics components are contained within the stator currents of the high-speed synchronous reluctance motor, SynRM, with salient pole rotor. They cause the power factor of SynRM to get worse. In this paper, the mathematical model of SynRM is investigated, and SV_PWM control method is applied to reduce harmonics components in the stator current. Simulation results show the fast response of speed and the reduction of harmonics components at steady state.

  • PDF

배전용 변압기의 실시간 고조파 분석 알고리즘 개발 (The Development of Real-Time Harmonic Analysis Algorithm in Distribution Transformer)

  • 박철우
    • 조명전기설비학회논문지
    • /
    • 제27권3호
    • /
    • pp.43-49
    • /
    • 2013
  • Recently harmonics flowing into power system is increasing as the usage of semiconductor equipments and switching mode power equipments are increasing. Harmonics cause problems such as heat increasing and reduction in capacity of transformers, especially the harmonics flowing into a distribution transformer can lead to the lifetime reduction of transformer. In this paper, we are about to develop a device that can monitor harmonics in real-time as it is affixed to a distribution transformer. Unlike the existing expensive harmonic analysis device, a new harmonic analysis algorithm is proposed in order to implement low-cost equipment. The real-time harmonic analysis algorithm proposed in this paper allows implementation on low performance microcontrollers, thus it can monitor the harmonic in real-time as it is individually affixed to the transformer. Therefore, it would improve the reliability of the transformer and stable power system operation would be possible as it can prevent the transformer accidents in advance.

SHE방식을 적용한 직류전력 회생시스템의 고조파 저감에 관한 연구 (A Study on the SHE-Based Harmonic Reduction of DC Power Regenerating Systems)

  • 정우창;강경우;서영민;홍순찬
    • 전력전자학회논문지
    • /
    • 제9권1호
    • /
    • pp.58-64
    • /
    • 2004
  • 본 논문에서는 직류를 전원으로 하는 지하철에서 직류모선의 잉여전력을 교류모선으로 회생할 수 있는 직류전력 회생시스템의 고조파를 저감시키는 새로운 제어기법을 제안하였다. 직류전력 회생시스템에 수정 a도통(MAC : Modified a-Conduction)방식을 적용하면 출력전압에 12k$\pm$1차의 고조파가 존재한다. 이에 반해 본 논문에서 제안하는 SHE(Selected Harmonic Elimination)에 기반을 둔 방식을 적용하면 11차 고조파와 13차 고조파가 추가로 제거된다. 또한 회생시스템의 출력단에 23차 교류필터를 설치하면 잔존하는 고조파중 최저차 고조파인 23차 고조파도 제거할 수 있다. 본 논문에서 제안한 SHE방식을 적용한 고조파 저감기법을 검증하기 위하여 축소모델을 대상으로 하여 시뮬레이션을 행하였다. 그 결과, 출력전압의 THD가 기존의 MAC방식보다 더 낮으며 제어범위에서의 THD가 0.53∼0.68(%) 범위임을 확인하였다.

태양광 계통연계형 하이브리드 변압기의 해석 및 성능시험 (Analysis and Performance Test of Hybrid Transformer used in the Grid-Connected Photovoltaic Generation System)

  • 김지호;박훈양;손진근
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.333-338
    • /
    • 2014
  • This paper concerns the development of the transformer that can reduce harmonics supplied to the system if the output of photovoltaic inverter in the photovoltaic system is grid-connected, and suggests that problems of harmonics and power factor degradation in the grid-connected photovoltaic system can be improved. In this study, the burden of increasing the investment in new facilities and securing their installation space due to harmonics has been substantially eased through the development of a hybrid transformer possessing unbalanced function and harmonics reduction function using zig-zag coils, and most of all, it is expected that the development of such high efficiency hybrid transformer possessing functions of transformation and reducing harmonics can improve the power quality as well as prevent damages caused by harmonics, leading to suppress unnecessary loss of electric power and thereby contribute to energy savings.

교류 전기철도 전력계통의 고조파 예측량 계산 (Estimation of Harmonics on Power System of AC Electric Railway)

  • 송진호;황유모
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권2호
    • /
    • pp.68-79
    • /
    • 2003
  • We estimated harmonics on power system of AC railway based on quantitatively measured harmonics and investigated the need of facilities for harmonics reduction. In order to analysis harmonics which inflow into power system due to increase in collector voltages and harmonic currents generated from the train when the railway is in operation, the railway system Is sectioned into power supply, railway line, AT, sectioning Post and subsectioning post. For analysis of extension of currents resulting from the railway loads, PWM converter, VVVF inverter and the feeder system are modeled based on the dynamic node technique(DNT). In order to test the usefulness of the DNT for analysis of harmonic effects, the measured harmonic currents and harmonic magnification ratios at the S/K substation are compared with simulation results using DNT modelling, which include the results for two cases with and without filters for suppression of harmonic currents. When 8 cars(4M4T) are in operation, the total sum of harmonic currents resulting from the train at M and T phases, which inflow into the substation along with the railway line, is calculated. Using the harmonics analysis program for railway feeder system with these data, the total harmonic distortion factor(710) at the outgoing point of KEPCO substation is computed. The calculation shows that when the maximum THD at the receiving point of H/K substation was 0.0443% which is much lower than 1.5% which is the allowable value of KEPCO at 154kV as well as IEEE-519 above 132kV This result indicates that any measure for harmonics reduction in Incheon International Airport Railway is not needed.

고속전철 변전소의 고조파 분석과 대책에 관한 연구 (A Study on Harmonic Analysis and Countermeasure at the High Speed Railway Substation)

  • 김재철;박수만;강창원
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.138-143
    • /
    • 2004
  • 본 논문은 고속전철 차량에서부터 변전소까지의 고조파에 대해서 분석하였으며, 수동필터를 이용한 고조파 저감 방법을 제시한다. 고속전철 변전소가 공급하는 열차구간에 있어서 운행 열차의 수에 따라 고조파의 파급 특성을 살펴보았다. 고조파는 변압기 과열과 통신유도장해 등 문제를 일으킬 수 있다. 이러한 고조파에 의한 손상을 줄이기 위하여 본 논문은 고조파 저감방법을 제시하였다. 제안된 방법은 PSCAD/EMTDC 시뮬레이션에 의해 증명되었다.

Buck Converter 방식을 이용한 Universal Motor 구동시의 전원측 고조파 및 EMI 특성 (Source Harmonics and EMI Characteristics of Buck Converter Driving Universal Motor)

  • 김흥성;전윤석;조영준;최규하
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.99-102
    • /
    • 1996
  • In this paper input characteristics of Buck converter to drive small capacity universal motor is analyzed about current harmonics and EMI which is due to a switching effect. And as a strategy for EMI reduction, filter is designed. As a results it is approved that buck converter is adequate method to reduce low order harmonics.

  • PDF

탶변환 방식을 이용한 단상 정류회로의 고조파 저감 (Harmonics Reduction Using Tap Change Method of Single Phase Rectification Circuit)

  • 유철로;이공희;박현철;한우용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1988년도 추계학술대회 논문집 학회본부
    • /
    • pp.403-405
    • /
    • 1988
  • Recently, Power change devices using thyristor and transistor have grown with the rapid development of power electronics. But the devices using these semiconductors generate harmonics from the non-linear load, which gives rise to various obstacles. In this paper, therefore, as 3 taps are connected in input line, we can multiply the pulse in input line, by which harmonics is reduced.

  • PDF

SV PWM을 이용한 고속 릴럭턴스 동기 전동기 구동 (Reluctance Synchronous Motor Driving using SV PWM)

  • 김민태;오성업;성세진;백동기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.204-207
    • /
    • 1998
  • Many Harmonics components is contained within the stator currents of the High-speed Reluctance Synchronous Motor with salient pole rotor. They cause the power factor of RSM to get worse. In this paper, the mathematical model of RSM is investigated. And SV-PWM control method is applied to reduce Harmonics components in the stator currents. Simulation results shows the fast response of speed and the reduction of Harmonics components at steady state

  • PDF

계통 연계형 풍력발전 시스템의 고조파 저감 및 무효전력 보상 (Reduction of Harmonics and Compensation of Reactive Power about Wind Power Generation System Connected to Grid)

  • 김영민;황종선;김종만;박현철;송승호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1093-1096
    • /
    • 2002
  • In this paper, a novel multi voltage inverter system is proposed for reductions of harmonics, which can compensate reactive power. At first, we remove capacitor at input side for reactive power compensation. Secondly, by adding DC voltage to the filter capacitor, it can control power factors as lead-phase according to alterations of loads at power reception. Thirdly, if winding and single phase-bridge inverter(auxiliary circuit) is installed to DC power for reduction of harmonic, waveform of output voltages become to 36-steps. Thus, SVC(static var compensator) systems which can reduce harmonics are designed.

  • PDF