The Countermeasure about Harmonics of the High Voltage Power Facilities (고압수전설비의 고조파에 관한 대책)

  • Kim, Ju-Chan;Sin, Su-Han;Lee, Chung-Sik;Koh, Hee-Seog
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.353-357
    • /
    • 2004
  • This paper presents the result of survey of case study for harmonics in electrical installations of buildings. Recently, many power electronic equipments(power converter, computers, air conditioners electronic ballasts for fluorescent lamps and so on) are used in office buildings, and harmonic current from them influence the other equipments in a distribution line. Notably, voltage distortion or voltage harmonics may approach or exceed is allowable level in power distribution system. Individual electric power consumers and end-users and responsible for reducing current harmonics while companies or utilities are responsible for reducing voltage harmonics at the point of common coupling in distribution system. As for harmonics, which one of the electric power qualities, it becomes important to obtain harmonic voltage/current distribution of the power system precisely because the use of power electronic apparatus in increasing. To suppress harmonics in electrical ins tallations of buildings, one of many methods suggest that resonance frequencies are controlled by modulating the capacities of high-voltage customer's capacitors.

  • PDF

Design and Implementation of a Multi Level Three-Phase Inverter with Less Switches and Low Output Voltage Distortion

  • Ahmed, Mahrous E.;Mekhilef, Saad
    • Journal of Power Electronics
    • /
    • v.9 no.4
    • /
    • pp.593-603
    • /
    • 2009
  • This paper proposes and describes the design and operational principles of a three-phase three-level nine switch voltage source inverter. The proposed topology consists of three bi-directional switches inserted between the source and the full-bridge power switches of the classical three-phase inverter. As a result, a three-level output voltage waveform and a significant suppression of load harmonics contents are obtained at the inverter output. The harmonics content of the proposed multilevel inverter can be reduced by half compared with two-level inverters. A Fourier analysis of the output waveform is performed and the design is optimized to obtain the minimum total harmonic distortion. The full-bridge power switches of the classical three-phase inverter operate at the line frequency of 50Hz, while the auxiliary circuit switches operate at twice the line frequency. To validate the proposed topology, both simulation and analysis have been performed. In addition, a prototype has been designed, implemented and tested. Selected simulation and experimental results have been provided.

Harmonic Analysis and Output Filter Design of NPC Multi-Level Inverters (NPC 멀티레벨 인버터의 고조파 분석 및 출력 필터 설계)

  • Kim, Yoon-Ho;Bang, Sang-Seok;Kim, Kwang-Seob;Kim, Soo-Hong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.135-141
    • /
    • 2006
  • In this paper, LC output filters are designed to reduce output harmonics and harmonic analysis are peformed. Generally, multilevel inverters are used in high power application and operates with low switching frequency, which, in turn, generates large output harmonics. Output filters we used to reduce output harmonics. The design approach to reduce output harmonics of the 31eve1 multilevel inverter is discussed and DSP(TMS320C31) is used for the digital control of the system. The design example is given. The designed system is verified by simulation and experiment.

Evaluation and Planning of Distribution System Considering Reliability and Harmonics (신뢰도와 고조파를 고려한 배전시스템의 평가 및 계획)

  • Lee Buhm;Kim Yong-ha;Choi Sang-kyu
    • Journal of Energy Engineering
    • /
    • v.14 no.3 s.43
    • /
    • pp.167-172
    • /
    • 2005
  • This paper presents a methodology to support decision making for distribution system planning based on value. To evaluate the reliability value, we employ valued-based distribution reliability assessment. To evaluate the harmonics value, we employ a marginal pricing method, and by using reliability cost, harmonics cost, and construction cost, we can make the most economic decision. By applying the method to the real system, we show this method can get the best result which meet reliability and harmonics level.

Evaluation of Sound Quality of Air-conditioning Noise (에어컨 소음의 Sound Quality 평가)

  • Jeon, Jin-Yong;You, Jin;Kim, Su-Yeon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.5 s.110
    • /
    • pp.551-558
    • /
    • 2006
  • Noise from air-conditioner system installed in the ceiling of a classroom was evaluated to investigate the sound quality of air-conditioning noise. Harmonics of air-conditioning noise were removed and the sound pressure levels of the frequency bands from $250{\sim}630Hz$ were changed to control sound quality. Evaluation for refreshing sensation was conducted using a paired comparison method and the results showed that noise without harmonics were preferred to noise with harmonics. The noises which have larger level increases to the unchanged noise at $250{\sim}630Hz$ were evaluated better in both of the noises with and without harmonics. Results of multiple regression analysis on psychoacoustic parameters and subjective preferences showed sharpness as a major affecting factor in describing the refreshing aspect of air-conditioning sound.

Grid-friendly Control Strategy with Dual Primary-Side Series-Connected Winding Transformers

  • Shang, Jing;Nian, Xiaohong;Chen, Tao;Ma, Zhenyu
    • Journal of Power Electronics
    • /
    • v.16 no.3
    • /
    • pp.960-969
    • /
    • 2016
  • High-power three-level voltage-source converters are widely utilized in high-performance AC drive systems. In several ultra-power instances, the harmonics on the grid side should be reduced through multiple rectifications. A combined harmonic elimination method that includes a dual primary-side series-connected winding transformer and selective harmonic elimination pulse-width modulation is proposed to eliminate low-order current harmonics on the primary and secondary sides of transformers. Through an analysis of the harmonic influence caused by dead time and DC magnetic bias, a synthetic compensation control strategy is presented to minimize the grid-side harmonics in the dual primary side series-connected winding transformer application. Both simulation and experimental results demonstrate that the proposed control strategy can significantly reduce the converter input current harmonics and eliminates the DC magnetic bias in the transformer.

Analysis of Harmonics Waveform Distortion for IDC(Internet Data Center) Power System and effect of multi-Phase (IDC(Internet Data Center) 전원기기 고조파 분석 및 다상화 효과 고찰)

  • 서정석;이상중;이희영;박정규
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.6
    • /
    • pp.109-118
    • /
    • 2002
  • As Information society has expanded in large scale. In order to improve the reliability and Qos(Quality of service), domestic IDC(Internet Data Center) has adopted or will adopt the SLAs(Service Level Agreements). The power quality of internet hosting server unit, power system and UPS is very important for better internet service. Therefore, the higher reliability or power system is imperative for satisfying SLAs. This paper presents the status measurement of domestic IDCs harmonics and illustrates the reduction effect of harmonics through the multi-phase.

Analysis. Design and Control of Two-Level Voltage Source Converters for HVDC Systems

  • Mohan, D. Madhan;Singh, Bhim;Panigrahi, B.K.
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.248-258
    • /
    • 2008
  • The Voltage Source Converter (VSC) is replacing the conventional line commutated current source converters in High Voltage DC (HVDC) transmission systems. The control of a two-level voltage source converter and its design dealt with HVDC systems and various factors such as reactive power, power factor, and harmonics distortion are discussed in detail. Simulation results are given for the two-level converter and designed control is used for bidirectional power flow. The harmonics minimization is taken by extending the 6-pulse VSC to multipulse voltage source converters. The control is also tested and simulated for a 12-pulse voltage source converter to minimize the harmonic distortion in AC currents.

Analysis and simulation of Cascaded H-bridge 7 level inverter for eliminating typical harmonic waveforms (특정 고조파 제거를 위한 Cascaded H-bridge 7레벨 인버터의 특성해석 및 시뮬레이션)

  • Jin, Sun-Ho;Oh, Jin-Suk;Jo, Kwan-Jun;Kwak, Jun-Ho;Lim, Myoung-Kyu;Kim, Jang-Mok
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2005.06a
    • /
    • pp.1022-1028
    • /
    • 2005
  • This paper is presented the analysis results and simulation results of cascaded H-bridge 7 level inverter with various modulation index. Stepped waveform having number of switching was used to eliminate harmonic components. Switching angles according to modulation index are calculated numerically. Therefore, 3 times of switching with 7 level topology and QWS(Quarter Wave Symmetry) could eliminate 5th and 7th harmonics. The harmonic characteristics are compared to those of space vector modulation method which known as common modulation method in industrial field. Stepped waveform method showed higher ability to reduce, especially lower order of harmonics.

  • PDF