• 제목/요약/키워드: Harmonics evaluation

검색결과 75건 처리시간 0.023초

The Analysis of Spectrum on the Barkhausen Noise of Hysteresis Loops on Neutron Irradiated Material

  • Sim, Cheul-Muu;Chang, Kee-Ok;Park, Kook-Nam;Cho, Man-Soon;Park, Chang-Oong
    • The Journal of the Acoustical Society of Korea
    • /
    • 제18권1E호
    • /
    • pp.7-12
    • /
    • 1999
  • In relation to a non-destructive evaluation of irradiation damages, the changes in the hysteresis loop and Barkhausen noise amplitude and the harmonics frequency due to a neutron irradiation were measured and evaluated. The Mn-Mo-Ni low alloy steel of RPV was irradiated to a neutron fluence of 2.3 ×10/sup 19/ n/㎠ (E ≥1 MeV) at 288℃. The saturation magnetization of neutron irradiated metal did not change. The neutron irradiation caused the coercivity to increase, whereas susceptibility to decrease. The amplitude of Barkhausen noise parameters associated with the domain wall motion were decreased by a neutron irradiation. The spectrum of Barkhausen noise is analysed with an applied frequency of 4 Hz and 8 Hz, sampling time of 50 μ sec and 20 μ sec. The harmonic frequency shows 4 Hz, 8 Hz, 12 Hz and 16 Hz reflected from an unirradiated specimen. On the contrary, the harmonic frequency disappeared on the irradiated specimen. In addition to the amplitude, the harmonic frequency of Barkhausen noise is taken into accounts as a promising tool for monitoring the irradiation induced degradation of the reactor materials such as a SA508 of PWR-RPV steel and a Zr₄ of HANARO-CNH.

  • PDF

환경조건의 변화에 따른 EPDM 애자의 표면 오손정도의 진단기술 (Diagnosis Technique of Surface Contamination Degree for EPDM Insulator according to Variation of Environment Condition)

  • 박재준;최인혁;김정부
    • 한국전기전자재료학회논문지
    • /
    • 제17권10호
    • /
    • pp.1132-1141
    • /
    • 2004
  • The waveforms of the leakage currents for the surface discharge according to the degree of salt contamination and the variation of environmental condition on the EPDM polymer insulators, were shown in this paper. The variation phenomena of fundamental wave, 3rd and 5th harmonic waveforms were also shown from the beginning of the applied voltage and to the flashover voltage. To develop the technique of percentage contamination degree of EPDM polymer insulator according to the variation of environmental condition, the distortion degree of 3rd and 5th harmonic wave to the fundamental wave was utilized through the spectrum analysis for the waveforms of leakage current in the simulation of salt and fog test. The fact that distortion degree % of 3rd and 5th harmonics for fundamental wave is a necessary indicator for the assessment of contamination degree for the polymer insulators, was known.

KGT-74 소형 가스터빈 블레이드의 진동 신뢰성 평가 (Evaluation of Blades Vibration Reliabilities of KGT-74 Small Gas Turbine)

  • 이안성;김영철;이동환;나언주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.297-302
    • /
    • 2003
  • To ensure a safe operation of the prototype KGT-74 ㎾ small gas turbine, vibrational reliabilities of the compressor 1st, 2nd. and 3rd stages and turbine blades have been estimated and reviewed. FE analyses have been tarried out to obtain the natural vibration characteristics of the blades, and impact modal testings have been performed on every each one of the blades to measure their 1st natural frequencies. Then, the Campbell diagram analyses have been carried out to Judge the safety of the blades from resonant failures up to 6k harmonics. Results show that the compressor 1st stage blade is exposed to a potential resonant failure with 3k harmonic around a rated speed of 30,000rpm but that the other compressor 2nd and 3rd stages and turbine blades are safe from resonant failures. Finally. 27,900 rpm Is selected as the safe operation limit for the KGT-74 ㎾ gas turbine relative to the blade vibrations.

  • PDF

Spectrum analysis of acoustic Barkhausen noise on neutron irradiated material

  • Sim Cheul-Muu;Park Seung-Sik;Park Duck-Gum;Lee Chang-Hee
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 2000년도 학술발표대회 논문집 제19권 2호
    • /
    • pp.231-234
    • /
    • 2000
  • In relation to a non-destructive evaluation of irradiation damage of micro-structure of interstitial, void and dislocation, the changes in the hysteresis loop and Barkhausen noise amplitude and the harmonics frequency due to neutron irradiation were measured and evaluated. The Mn-Mo-Ni low alloy steel of reactor pressure vessel was irradiated to a neutron fluence of $2.3\times10^{19}n/cm^2$ $(E\ge1MeV)$ at $288^{\circ}C.$The saturation magnetization of neutron irradiated metal did not change. Neutron irradiation caused the coercivity to increase, whereas susceptibility to decrease. The amplitude of Barkhausen noise parameters associated with the domain wall motion were decreased by neutron irradiation. The spectrum of Barkhausen noise was analyzed with an applied frequency of 4Hz and 8Hz, and a sampling time of 50 $\mu$ sec and 20 $\mu$ sec. The harmonic frequency of Joule effect shows 4Hz, 8Hz, 12Hz and 16Hz reflected from an unirradiated specimen. On the contrary, the harmonic frequency disappeared for the irradiated specimen. Harmonic frequency of induced voltage of sinusoidal magnetic field And Spectrum of Barkhausen noise on material is determined.

  • PDF

이중 푸리에 급수 분광법 역학코어의 정확도와 계산 효율성 평가 (Evaluation of Accuracy and Efficiency of Double Fourier Series (DFS) Spectral Dynamical Core)

  • 김범석;구명서;손석우
    • 대기
    • /
    • 제33권4호
    • /
    • pp.387-398
    • /
    • 2023
  • The double Fourier series (DFS) spectral dynamical core is evaluated for the two idealized test cases in comparison with the spherical harmonics (SPH) spectral dynamical core. A new approach in calculating the meridional expansion coefficients of DFS, which was recently developed to alleviate a computational error but only applied to the 2D spherical shallow water equation, is also tested. In the 3D deformational tracer transport test, the difference is not conspicuous between SPH and DFS simulations, with a slight outperformance of the new DFS approach in terms of undershooting problem. In the baroclinic wave development test, the DFS-simulated wave pattern is quantitatively similar to the SPH-simulated one at high resolutions, but with a substantially lower computational cost. The new DFS approach does not offer a salient advantage compared to the original DFS while computation cost slightly increases. This result suggests that the current DFS spectral method can be a practical and alternative dynamical core for high-resolution global modeling.

인천 국제공항청사 경전철 도입에 따른 고조파 영향 분석 (Hormonic Evaluation of An Imported IAT(Intra Airport Transit) System in Incheon International Airport)

  • 김진오;송학선
    • 조명전기설비학회논문지
    • /
    • 제20권1호
    • /
    • pp.41-47
    • /
    • 2006
  • 최근 전기철도에 고속화 기술이 적용되고 열차 구동장치 및 제어계통에 전력용 반도체 소자가 사용되고 있으며, 전기철도 구동시스템의 주요 구성장치인 인버터와 컨버터의 동작을 제어하는 전력전자 소자의 이용은 고조파를 발생의 원인이 된다. 이러한 고조파는 통신장해 및 전류, 전압의 전력품질 저하 등 여러 가지 문제를 발생시킨다. 따라서 본 논문에서는 인천 국제공항에 설치되고 있는 경전철 전력설계의 전력시스템 평가 및 개발을 통해 상위 계통에 미치는 영향 및 전력시스템에서 발생할 수 있는 장애 요인을 사전에 예측 계산하여 이에 대한 대책을 마련하여 전력품질 향상에 목적이 있다. 인천 국제공항청사 내의 전력시스템의 전력품질 문제 접근에 있어 경전철이 운행될 경우 발생할 수 있는 여러 문제 중 특히 전압강하 및 전압불평형에 영향을 미치는 고조파 발생에 대해 분석하였다. 고조파 분석은 IEEE 519-1992(IEEE 141-1993과 동일) 기준에 의거하여 행하였다. 또한 인천 공항청사의 운행되는 경전철은 동적 전력시스템 해석 프로그램인 PSCAD/EMTDC 모델링하고 이의 시뮬레이션 결과를 이용하여 고조파 분석을 하였다.

전력계통 전력품질 통합진단시스템 개발 (The Development of Integrated Power Quality Diagnosis System for Power System)

  • 곽노홍;전영수;박상호;이일무;박희철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.277-279
    • /
    • 2005
  • Recently, due to the increase of power conversion devices and nonlinear loads with the development of information, communication and control technologies, the instantaneous minute interruption factors such as voltage & current harmonics, surge occurring frequency, instantaneous voltage variation, voltage unbalance, flicker etc. have greatly threatened the power quality, and the deterioration of electric power facilities and the functional error of controllers are increasing. As such an instantaneous minute interruption appears to be small and local, accurate evaluation with measurement is difficult and total analysis system is required through a wide range of power quality effect analysis such as the simultaneous measurement on various power supply phenomena and the analysis on the interrelation with system loads. Most of conventional power quality diagnosis equipments have beer developed and applied, which were able to measure the stability rate of frequency, the stability rate of voltage, the electricity-failure duration etc, However, they were insufficient to analyze the system present situation, understand the cause of the failure occurred by the problem of power quality and analyze out the phenomena. Accordingly, this study will address the development of the system for a wide range of power quality diagnosis over the present level, the system for supporting the determination such as the analysis on risk factors, failure mode and impact, the system for harmonic evaluation based on international standards(IEC 61000 Series) and the total power quality diagnosis network & system with the extension and openness as a local and national-scale broadband power quality diagnosis system.

  • PDF

하모닉 정보를 이용한 SAOC의 보컬 신호 제거 방법에 관한 연구 (A Study on Vocal Removal Scheme of SAOC Using Harmonic Information)

  • 박지훈;장대근;한민수
    • 한국멀티미디어학회논문지
    • /
    • 제16권10호
    • /
    • pp.1171-1179
    • /
    • 2013
  • IAS는 대게 사용자가 자신의 취향에 맞는 음악을 직접 제작 및 편집 가능한 기능을 제공하는 서비스이다. SAOC는 낮은 전송률로 IAS가 가능한 다객체 오디오 코딩 기술이다. 하지만 SAOC 기법은 특정 객체를 제거하는 경우, 특히 보컬 객체를 제거하는 경우 배경음악에 보컬 객체의 하모닉이 남아있는 문제점이 있다. 그래서 본 논문은 하모닉 추출과 제거를 사용한 보컬 객체 제거 기법을 제안한다. 제안 하는 기법은 부호화기에서 추출한 하모닉 정보를 이용하여 복호화기에서 보컬 객체 신호를 다운믹스 신호에서 제거하는 기법이다. 하모닉 정보로써, 기본 주파수, MVF, 하모닉 크기를 사용한다. 성능평가로 객관적, 주관적 실험을 수행하였으며 모든 실험 결과를 통해 SAOC 기법보다 제안하는 기법이 우수함을 확인한다.

가역투자율에 의한 첨단 페라이트강의 잔여수명에 대한 비파괴평가 (Nondestructive Characterization for Remanent Life of Advanced Ferritic Steel by Reversible Permeability)

  • 홍승표;류권상;김정석
    • 비파괴검사학회지
    • /
    • 제33권2호
    • /
    • pp.181-186
    • /
    • 2013
  • 가역투자율을 이용하여 차세대 에너지 설비 재료로 사용되는 첨단 페라이트강의 잔여수명을 비파괴적으로 평가하고자 하였다. 가역투자율 측정법은 가역투자율 값이 자기 히스테리시스 루프의 미분과 동일하다는 이론을 기반으로 하게 된다. 측정 원리는 한 가진진동수로 가변된 락-인 증폭기를 사용하여 탐지코일에 유도된 조화성분들의 진폭 값을 기본으로 한다. 가역투자율의 피크 간격, 비이커스 경도 그리고 인장강도는 시효된 샘플들에서 시효시간이 증가함에 따라서 감소하였다. 가역투자율의 피크 간격과 라손-밀러 파라미터의 관계를 통해 첨단 페라이트강의 잔여수명을 비파괴적으로 예측하는 것이 가능해진다.

개별 전로 전력 계측을 위한 디지털 신호처리 프로세서 기반 전력 관제 시스템의 제작 및 평가 (Fabrication and Evaluation of Digital Signal Processor for Multi-Lane Energy Measurement System)

  • 김근준;강봉순
    • 전기전자학회논문지
    • /
    • 제22권3호
    • /
    • pp.619-623
    • /
    • 2018
  • 사회의 발달로 인하여 전력에 대한 수요가 증가함과 동시에 전력의 품질 관리가 중요한 문제로 부상하였다. 이러한 전력관리를 효율적으로 수행하기 위하여 본 논문에서는 다선로 전력 계측을 위한 DSP 기반 전력 측정 시스템을 제안한다. 종래의 전력 계측 시스템이 하나의 선로의 전력만을 측정 할 수 있었기 때문에, 개별 선로에 대한 전력 품질 측정을 위해서는 선로마다 전력 품질 측정 장치가 필요로 하였으며 이는 비용적인 문제로 인하여 시스템의 실제 구현이 불가능한 구조였다. 본 논문에서 제안하는 시스템은 디지털 신호 처리 알고리즘을 이용하여 최대 12개소의 전력 품질을 실시간 계측 할 수 있는 시스템을 제안하며, 이를 토대로 한 시제품을 한국전기연구원의 공인시험 성적서를 통하여 그 성능을 평가 받았다. 성능 시험결과 정밀 계측의 오차 범위 ${\pm}0.3%$의 우수한 성능임을 평가 받았다.